• 제목/요약/키워드: Ventilation frequency

검색결과 143건 처리시간 0.033초

소아의 기계적 환기요법 (Mechanical Ventilation of the Children)

  • 박준동
    • Clinical and Experimental Pediatrics
    • /
    • 제48권12호
    • /
    • pp.1310-1316
    • /
    • 2005
  • Mechanical ventilation in children has some differences compared to in neonates or in adults. The indication of mechanical ventilation can be classified into two groups, hypercapnic respiratory failure and hypoxemic respiratory failure. The strategies of mechanical ventilation should be different in these two groups. In hypercapnic respiratory failure, volume target ventilation with constant flow is favorable and pressure target ventilation with constant pressure is preferred in hypoxemic respiratory failure. For oxygenation, fraction of inspired oxygen($FiO_2$) and mean airway pressure(MAP) can be adjusted. MAP is more important than FiO2. Positive end expiratory pressure(PEEP) is the most potent determinant of MAP. The optimal relationship of $FiO_2$ and PEEP is PEEP≒$FiO_2{\times}20$. For ventilation, minute volume of ventilation(MV) product of tidal volume(TV) and ventilation frequency is the most important factor. TV has an maximum value up to 15 mL/kg to avoid the volutrauma, so ventilation frequency is more important. The time constant(TC) in children is usually 0.15-0.2. Adequate inspiratory time is 3TC, and expiratory time should be more than 5TC. In some severe respiratory failure, to get 8TC for one cycle is impossible because of higher frequency. In such case, permissive hypercapnia can be considered. The strategy of mechanical ventilation should be adjusted gradually even in the same patient according to the status of the patient. Mechanical ventilators and ventilation modes are progressing with advances in engineering. But the most important thing in mechanical ventilation is profound understanding about the basic pulmonary mechanics and classic ventilation modes.

미세 후두현미경술시 윤상갑상막천자를 통한 고빈도 제트환기법 (High Frequency Jet Ventilation via Cricothyroid Membrane Puncture under Microlaryngoscopic Surgery)

  • 양훈식;김용주;김춘길
    • 대한기관식도과학회지
    • /
    • 제1권1호
    • /
    • pp.109-115
    • /
    • 1995
  • High frequency Jet ventilation (HFJV) via cricothyroid membrane puncture contols frequency of ventilation as 20-200/min and persuits adequate gas exchange. HFJV was known to have advantages such as improvement of PaO$_2$, lesser barotrauma, stable hemodynamic effects, good operative field and lesser movement of head. The purpose of this study was to clarify the advantages of HFJV in cases of microlaryngeal surgery which operating time was expected even within 30 minutes. Twenty-eight patients were divided two groups : 1)control group : general endotracheal Intubation anesthesia. 2)experimental group : HFJV via cricothyroid membrane puncture with intravenous anesthesia, frequency 40/min, I/E ratio 40%, driving pressure 40 psi. We analyzed blood pressure, arterial blood gas, score of general condition and recovery time after operation. In conclusion, HFJV via cricothyroid membrane puncture had a good score of general condition and rapid recovery of consciousness, although some accumulation of P$CO_2$and elevation of blood pressure.

  • PDF

Theoretical Prediction of Lung Hyperinflation(LHI) Due to Asymmetric Pressure-Flow Characteristics of Human Airways During High Frequency Ventilation (HFV)

  • Cha, Eun-Jong
    • 대한의용생체공학회:의공학회지
    • /
    • 제11권2호
    • /
    • pp.195-202
    • /
    • 1990
  • The hypothesis of asymmetric resistance to explain the phenomenon of lung hyperinflation (LHI) during hlgh frequency ventilation (HFV) was quantitatively studied. LHI was predicted by modeling the ism-volume pressure-flow (IVPF) data from 5 human subjects using the empirical Rohrer's equation. Non-steadiness during HFV was compensated by em- ploying recently proposed volume-frequency diagram. Tidal volume and ventilation frequency were 100 ml and 20 Hz, respectively. Airflow pattern was a symmetric sinusoid. The predic- tion results of mean pressure drop across the airways were averaged for those 5 subjects, and compared with zero by one-sided student's t-test. A marginally significant (P<0.1) increase in mean pressure drop was observed during HFV at low lung volumes (below FRC) , which could increase mean lung volume up to one liter When the lung volume was above FRC, no significant LHI (P >0.25) was resulted. LHI seemed to be inversely related to the lung volume. These results recommend to clinically apply HFV only at lung volumes above FRC.

  • PDF

Respiratory Review of 2013: Critical Care Medicine

  • Choi, Hye Sook
    • Tuberculosis and Respiratory Diseases
    • /
    • 제75권1호
    • /
    • pp.1-8
    • /
    • 2013
  • Several papers on respiratory and critical care published from March 2012 to February 2013 were reviewed. From these, this study selected and summarized ten articles, in which the findings were notable, new, and interesting: effects of high-frequency oscillation ventilation on acute respiratory distress syndrome (ARDS); safety and efficacy of hydroxyethyl starch as a resuscitation fluid; long-term psychological impairments after ARDS; safety and efficacy of dexmedetomidine for sedation; B-type natriuretic peptide-guided fluid management during weaning from mechanical ventilation; adding of daily sedation interruptions to protocolized sedations for mechanical ventilation; unassisted tracheostomy collar of weaning from prolonged mechanical ventilations; and effects of nighttime intensivist staffing on the hospital mortality rates.

CFD analysis of ventilation efficiency around an elevated highway using visitation frequency and purging flow rate

  • Huang, Hong;Kato, Shinsuke;Ooka, Ryozo;Jiang, Taifeng
    • Wind and Structures
    • /
    • 제9권4호
    • /
    • pp.297-313
    • /
    • 2006
  • The concentration of air pollution along roads is higher than the surrounding area because ventilation efficiency has decreased due to the high-density use of space along roads in recent years. In this study, ventilation efficiency around a heavily traffic road covered by an elevated highway and hemmed in along its side by buildings is evaluated using Visitation Frequency (VF, the frequency for pollutant to return to the objective domain) and Purging Flow Rate (PFR, the air flow rate for defining the local domain-averaged concentration). These are analyzed using Computational Fluid Dynamics (CFD) based on the standard $k-{\varepsilon}$ model. The VF and PFR characteristics of four objective domains are analyzed in terms of the changes in wind direction and arrangements of the fencing dividing up and down direction in the road center under the elevated highway. The resulting VFs are more than 1.0 for all cases, which means that pollutants return to the objective domain restricted by the elevated highway and side buildings. The influence of the arrangement of the buildings around the objective domain and the structure in the domain on the VF is substantial. In cases where there are no obstacles under the elevated highway, the local air exchange rate in the domain tends to be improved. Using these indices, the urban ventilation efficiencies between different urban areas can be compared easily.

건강주택 실현을 위한 공동주택 거주자의 환기행태 및 환기기기 관리 특성에 관한 연구 (The Characteristics of Behavior for Ventilation and Maintenance for Ventilation Equipments by Multi-family Housing Residents to Actualize Healthy Housing)

  • 이윤재
    • 한국주거학회논문집
    • /
    • 제21권5호
    • /
    • pp.93-101
    • /
    • 2010
  • The purpose of the study is to investigate the behaviors for ventilation to control indoor air quality and characteristics of the maintenance for ventilation equipments by multi-family housing residents. This study was conducted by the survey in the area of Seoul and Kyungki-do. The results of the study are as follows: the majority of respondents conduct ventilation once a day, below 20 minutes with opening some windows of the inside of the house. The time for ventilation is generally between 9-11 am. and 5-7 pm. Most of the wives are responsible for ventilation activities. In addition, so far building materials and furniture are not seriously considered as the source of indoor air pollution by the respondents. Their satisfaction for indoor air before and after ventilation is perceived as just the level of average. As the mechanical ventilation equipments such as a hood and an exhaust fan, half of the respondents are using them frequently. However, the ventilation equipments are not maintained well. Specially maintenance and checks for exhaust fans are hardly conducted. In conclusion, the frequency of ventilation is very limited and residents show passive attitudes about ventilation and maintenance of ventilation equipments. Therefore, for the actualization of healthy housing, educational programs and guidelines on the way of ventilation targeting the residents should be set up and a certain organization has to check periodically the performance of the ventilation equipments of each house in the multi-family housing complex.

실내주차장의 실내공기질 농도특성 및 환기에 의한 저감효과 (The Effect of Ventilation and Concentration of Indoor Air Quality at Indoor Parking Lots)

  • 박정호
    • 한국산업보건학회지
    • /
    • 제20권4호
    • /
    • pp.241-247
    • /
    • 2010
  • Recently, indoor air quality (IAQ) has been one of the major concerns of people. Indoor parking lots are subject to be exposed to high concentrations of air pollutants emitted from vehicles. This study was performed to investigate indoor air quality (IAQ) at indoor parking lots. Sampling sites were selected 5 indoor parking lots. Target indoor air quality parameters include a number of criteria pollutants such PM$_{10}$, CO, CO$_2$, and HCHO. In addition, a variation of IAQ according to ventilation system operating was measured at C site (underground parking lot). In general, all pollutants were maintained below indoor air quality maintenance standards. The indoor air quality at indoor parking lots was affected by the availability of the ventilation facility and their operation frequency. At the underground parking lot (C site) with ventilation system, TVOC concentration according to ventilation system operating were found to be lower operating (488.2 ${\mu}g/m^3$) than non-operating (1,401.2 ${\mu}g/m^3$).

가솔린 풀 화재에서 인체 호흡량 변화를 고려한 연소가스 농도 측정 결과 분석 (Analysis on the Results of Measured Concentration of the Combustion Gases Considering Respiration Characteristics in Gasoline Pool Fire)

  • 최승일;강정기;유우준
    • 한국화재소방학회논문지
    • /
    • 제33권4호
    • /
    • pp.83-88
    • /
    • 2019
  • 본 연구에서는 가솔린 풀화재 시 호흡량과 호흡주기 변화에 따라서 인체에 흡입되는 연소가스 농도에 관한 기초 연구를 수행하였다. 이를 위해서 ISO 9705 룸코너 시험기의 1/4 크기인 구획공간을 제작하였으며, 호흡유량 (2, 6, 10) LPM 에 대해서 연소가스를 지속적으로 흡입하는 경우(Infinity)와 호흡주기가 2 s와 5 s인 각각의 경우 일산화탄소와 산소 농도를 측정하였다. 그 결과 구획 공간에서 가솔린 풀화재의 이론 발열량이 5.34 kW인 연소조건에서 산소와 이산화탄소의 경우 모두 호흡주기에 비해서 호흡량이 증가함에 따른 농도 편차가 더욱 높은 것을 확인하였다. 또한, 호흡 주기가 증가함에 따라서 산소 농도의 경우 최소값의 변화가 평균값에 비해서 더욱 크게 나타난 반면 일산화탄소 농도의 경우 평균값의 변화가 최대값에 비해서 더욱 크게 나타났다. 이러한 결과는 화재 시 피난자의 호흡 특성에 따라서 실제 흡입되는 유해가스의 농도를 고려하여야 보다 정확한 피난 특성을 예측할 수 있는 것으로 사료된다.

수면시 바닥표면온도에 따른 적정 환기량에 관한 연구 (A Study on the Proper Quantity of Ventilation through Changing Floor Temperature in Sleeping)

  • 김동규;이성;김세환
    • KIEAE Journal
    • /
    • 제10권1호
    • /
    • pp.19-24
    • /
    • 2010
  • Modern people are spending most of time in interior area. Indoor air environmental problem is one of the most effective factors influenceable to human health. Furthermore, saving energy and making ventilation system for pleasant indoor environment are necessary when it is faced shortage of energy over the world. In our country's case, it is already imposed that required quantity of air ventilation in buildings is 0.7 times per hour on "The regulation on building engineering system". As on the rise of the interests about Indoor air environment, Heat and Carbon dioxide emissions from User's metabolism, activity, furniture, and construction materials etc. could be the causes of Indoor air pollution. If these materials stays in Indoor air for so long, it could directly influence the user's health condition with a disease. As of building's sterilization improved that raised more mechanical ventilation. It also leads much energy waste in a period of high price of fossil fuel. Therefore, the way that saves energy and effective control of indoor ventilation is urgently needed. So, this study places the purpose on validating volume of indoor ventilation and user's comfortable degree by comparison CO2 emission rate through changing floor temperature.

기도유지기 마스크 환기마취를 이용한 비관혈적 비골골절 정복술 (Closed Reduction of Nasal Bone Fracture Under the Mask Ventilation Anesthesia Using Oral Airway)

  • 박병찬;남현재;이준호;김용하;허민정;서일숙
    • 대한두개안면성형외과학회지
    • /
    • 제9권2호
    • /
    • pp.77-80
    • /
    • 2008
  • Purpose: The majority of nasal fractures have been treated by closed reduction. And they were manipulated under local anesthesia or general anesthesia. Under the local anesthesia, patients can feel the pain and fear, so general anesthesia through the endotracheal intubation became popularized recently to treat the nasal fracture. But it has still the drawbacks of postanesthetic complication. Therefore, under the mask ventilation anesthesia using oral airway, we tried to manipulate the nasal fracture. Methods: From July 2007 to November 2007, we worked with fifty patients that were manipulated the nasal fracture. Fifty patients were divided into two groups, general anesthesia with the endotracheal intubation group(n=25) and the mask ventilation using oral airway group(n=25). We checked up the anesthesia time, postanesthetic complication, postoperative aesthetic & functional problem of nose in two groups. Results: In total operation time and sore throat frequency among the postoperative anesthetic complications, there was statistically significant difference between the mask ventilation group and the endotracheal intubation group(p<0.05). But there was no difference statistically in nausea frequency(p>0.05). And no patients complained of postoperative nasal complication such as septal deviation, septal perforation, nasal obstruction and hump nose in two groups. Conclusion: Through the mask ventilation using oral airway, we could reach satisfactory results in the anesthetic time and postanesthetic complication.