• Title/Summary/Keyword: Ventilation System

Search Result 1,337, Processing Time 0.034 seconds

VOC/HAPs Emission Characteristics & Adsorption Evaluation for Paint Products in Busan Area (부산지역 페인트제조시설의 VOC/HAPs 배출특성 및 흡착능 평가)

  • Song, Bok-Joo;Lee, Seung-Min;Cho, Gab-Je;Cho, Jeong-Gu;You, Pyung-Jong;Kim, Gi-Gon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.5
    • /
    • pp.316-325
    • /
    • 2012
  • In this study, we suggested adequate control technology by analyzing emission process and main chemical of VOC/HAPs generated from four paint factories in Busan area. And we estimated whether Kapok fiber, which is a natural material, can be commercially used for an absorbent by testing adsorption ability. As a result of this sturdy, above 60% of VOC/HAPs was volatilized and dispersed inside the working place without conducting control system of facilities during manufacturing paints. Concentration profile of VOC/HAPs, which is volatile naturally outside the factories, is surveyed above 70% at Toluene, Ethylbenzene, and Xylene. And a result of evaluation of odor attribution level about the component whose Odor Threshold is known, it is estimated that major cause material of A, B, C factories is Toluene and that of D factory is m/p-Xylene. And that result presented design arguments such as facilities specifications, activated carbon filling volume, and replace cycle of activated carbon as control technology. Also, that result presented emission process improvement such as adsorption of central-controlled ventilation device, installation of inlet flenge, and potable cleaning process. The rate of pollutant adsorption of Kapok fiber, which is natural material, is indicated about 91.9%, 66.7%. That result validated the possibility as replacement of activated carbon.

Study on the Characteristics of Odor Emitted from Swine Facilities (양돈시설에서 발생하는 악취특성에 관한 연구)

  • Kim, Jae Hyuck;Yoo, Kyung Seun;Oh, Je Beom;Jung, Ju Young
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.7
    • /
    • pp.439-444
    • /
    • 2012
  • We studied the characteristics of odor emitted from 40 swine facilities across the country under various conditions like rearing densities, management style, ventilation system and swine manure handling characteristics, based on the olfactory and analytical evaluation. Odor concentrations (D/T) measured from swine facilities were respectively an average 4,055 D/T at liquid manure storage tanks on aeration, an average 913 D/T at slurry manure storage, an average 506 D/T at finishing swine facilities and an average 201 D/T at composting facilities. The higher rearing densities and slurry accumulation volume in finishing swine house, the more odor concentration (D/T) was increased. But The odor concentration (D/T) in finishing swine house did not show significant difference according to application of microbial additives. 9 odor compounds ($NH_3$, $H_2S$, MM, DMS, DMDS, PA, n-BA, n-VA, i-VA) were detected at swine facilities and the main odor compounds were volatile sulfur compounds such as $H_2S$, MM and volatile fatty acids compounds such as n-BA, n-VA, i-VA. 97.5% of swine farms surveyed in this study is located within 300 m of residential area and it is easy to bring odor complaints.

Blood Gas Analysis of Respiratory Depression during Sevoflurane Inhalation Induction for General Anesthesia in the Disabled Patients (장애 환자의 전신 마취를 위한 세보플루란 흡입 유도 시 발생한 호흡 저하의 혈액 가스 분석)

  • Yoon, Taewan;Kim, Seungoh
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.45 no.4
    • /
    • pp.508-513
    • /
    • 2018
  • Tidal volume by sevoflurane in small amounts is stable due to the increase in the breathing rate. But alveolus ventilation decreases due to sevoflurane as the degree of sedation increases; this ultimately causes $PaCO_2$ to rise. The occurrence of suppression of breath increases the risk of severe hypoxia and hypercapnia in deeply sedated patients with disabilities. Sevoflurane inhalation anesthesia has a number of risks and may have unexpected problems with hemodynamic changes depending on the underlying state of the body. This study was conducted to examine the stability of internal acid-base system caused by respiratory depression occurring when patients with disabilities are induced by sevoflurane. Anesthetic induction was carried out by placing a mask on top of the patient's face and through voluntary breathing with 4 vol% of sevoflurane, 4 L/min of nitrous oxide, and 4 L/min of oxygen. After the patient's loss of consciousness and muscle relaxation, IV line was inserted by an expert and intravenous blood gas was analyzed by extracting blood from vein. In a deeply sedated state, the average amount of pH of the entire patients was measured as $7.36{\pm}0.06$. The average amount of $PvCO_2$ of the entire patients was measured as $48.8{\pm}8.50mmHg$. The average amount of $HCO_3{^-}$ of the entire patients was measured as $27.2{\pm}3.0mmol/L$. In conclusion, in dental treatment of patients with disabilities, the internal acid base response to inhalation sedation using sevoflurane is relatively stable.

A study on the management of harmful working environments for Increase of Labor productivity. (노동생산성 향상을 위한 유해작업환경관리에 관한 연구)

  • 조태웅;유익현;박성애
    • Journal of Environmental Health Sciences
    • /
    • v.3 no.1
    • /
    • pp.27-44
    • /
    • 1976
  • This study was carried out to evaluate the harmful factors in working environments and to investigate the labor productivity after improvement of environments, surveying 93 industrial establishments of 10 industries located in Youngdeungpo industrial area in Seoul. The results obtained were as follows: 1) The highest noise level of 125dB(A) was indicated at the rolling process of transport equipment manufacturing industry. 2) The best illumination level was shown in precise machinery industry and the worst was indicated in rubber products, metallic products and transport equipment manufacturing industries. 3) Thermal conditions were above threshold limit value (TLV) at more than two processes of all industries except printing industry. 4) The highest dust concentration was determined in textile and wearing manufacturing industry. 5) Organic solvents were detected at 52 processes in 93 industrial establishments and 33 processes of them showed higher than TLV. The results about harmful chemicals were as follows: a) sulfur dioxide ($SO_2$)was determined higher than TLV on welding process of metallic product manufacturing industry and heat treatment process of transport equipment manufacturing industry. b) Carbon monoxide (CO) concentration was 700ppm at heat treatment process of transport equipment manufacturing industry, indicating 14 times of TLV. c) vinylchloride concentration in the air of PVC raw material mixing process and PVC preparation process of chemical product manufacturing industry was determined higher than TLV. d) Hydrochloride (HCl) concentration in the air of wire expanding process of transport equipment manufacturing industry was determined higher than TLV. 7) Higher values of lead concentration than TLV were determined at lead welding metallic product manufacturing industry and type planting process of process of printing industry, $1.8mg/m^3$ and $0.3mg/m^3$ respectively. 9) 22, 968 of 52, 855 workers (i.e. 43.5%) in 93 industries were exposed to various harmful agents. 10) It was found that the improvement of illumination in electric apparatus manufacturing industry (from 20~40 lux to 420 lux) resulted in an increase in productivity of 6.5% per capita and a decrease in faulty products of 19%. 11) Improvement of environments using local exhaust ventilation system resulted in a decrease of harmful substances lower than TLV and an increase in productivity of 11.4%. 12) Improvement of shovelling tools based on ergonomics resulted in a reduction in energy expenditure of 25.3% and an increase in productivity of 32.2% per capita.

  • PDF

Determination of HONO Concentration and Investigation on Its Formation Mechanism Using a Continuous Measurement System in Indoor Environment of an Apartment (아파트 실내 환경에서 실시간 측정시스템을 활용한 HONO 농도 측정 및 생성기작 연구)

  • Park, Seung-Shik;Hong, Jin-H.;Lee, Jai-H.;Kim, Young-J.;Cho, Sung-Y.;Kim, Seung-J.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.1
    • /
    • pp.16-29
    • /
    • 2008
  • Nitrous acid (HONO) can be produced by heterogenous reactions of nitrogen dioxide on surface materials and direct emission from combustion sources. However, a little is known of indoor HONO levels or the relationship between residential HONO, NO, and $NO_2$ concentrations in occupied houses. Therefore, we measured simultaneously NO, $NO_2$, and HONO concentrations in living room of an apartment using continuous analyzers to study the production of HONO (June $22{\sim}30$, 2006). The 4-min average concentrations of indoor NO, $NO_2$, and HONO were 4.3 (range: $0.4{\sim}214.3$), 10.3 ($2.0{\sim}87.3$), and 1.8 ppb ($0.3{\sim}7.7$), respectively. Peak levels of HONO up to 7.7 ppb and 24-hr averages as high as 1.7 ppb were measured. In agreement with previous studies, indoor HONO concentrations increased during operation of an unvented gas range. Examination of the observed kinetics suggests that the secondary production of indoor HONO, possibly as a result of heterogeneous reactions involving $NO_2$ and $H_2O$ is associated with $[NO_2]^2[H_2O]\;(r^2=0.88)$ rather than with $[NO][NO_2][H_2O]\;(r^2=0.75)$. Three combustion experiments at nighttime were also carried out to investigate the effects of vented combustion on the HONO, NO, and $NO_2$ concentrations. It was found to release HONO for $10{\sim}15$ minutes after NO and $NO_2$ source was turned off, and peak values were finally attained. Compared to unvented combustion, peak $NO_2$ and HONO concentrations were 3.2 and 2.0 times lower at weak vented combustion (air flow: $340\;m^3/hr$) and 4.9 and 2.4 times lower at strong vented combustion (air flow: $540\;m^3/hr$), respectively, emphasizing importance of operating ventilation hood fan during combustion to improve indoor air quality.

Massive pneumoperitoneum following cardiopulmonary resuscitation (심폐소생술 후 발생한 다량의 기복증)

  • Choi, Jeonjwoo;Shin, Sangyol;Hwang, Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3303-3307
    • /
    • 2015
  • The purpose of this study was attemped to investigate the clinical presentation and pathophysiology of 74-year-old female who developed pneumoperitoneum as complications of chest compression from sudden cardiac arrest. Such chest compression is the same one excercised to by-stander and paramedics. A healthy 74 year female had a sudden mental deterioration while working at a restaurant. She was transfered from 119 emergency medical system to the hospital. After the symptom developed, by-stander called 119 who carry out 6 minutes Cardiopulmonary resuscitation(CPR). Defibrillation and CPR was carried out by health provider after the arrival, and the patients spontaneous circulation returned. After Return of spontaneous circulation(ROSC), patients was transferred to the nearst hopspital, but suspicious of myocardial infarction, she was again transferred to a larger scale hospital. At the hospital she took X-rays and Abdominal CT, and the results of suspicious gastro-intestinal perforation near gastro-esophageal junction, surgical repair was recommended. But in operation room, while operation went on, cardiopulmonary arrest appeared again, and she expired. For this reason, prehospital CPR needs more accurate localization of cardiac massage and serious consideration of positive pressure ventilation. Moreover, treatment of pneumoperitoneum after CPR needs more cautious consideration of patients hemodynamic stability.

A Field Survey on the Odor Concentration in Piggery by the Change of the Season (돈사 내에서 계절별 악취 발생 농도 조사 연구)

  • Kam, D.H.;Jeong, J.W.;Choi, H.C.;Song, J.I.;Hong, J.T.;Lee, D.W.;Yoo, Y.H.
    • Journal of Animal Environmental Science
    • /
    • v.13 no.3
    • /
    • pp.187-194
    • /
    • 2007
  • Six pig farms were surveyed to measure the odor concentrations and characteristics of ammonia and sulfide corollary compounds in piggery. They were depended on the scale of piggery, weather conditions such as temperature, humidity, wind speed and direction, scales and types of pig breeding, and manure treatment methods. The highest ammonia concentrations in piggery were measured during the winter, since the tight sealed insulation in piggery made less amount of generated ammonia discharged from piggery. The objective of this study was to measure concentrations of odor in the piggery by season and growing, and to measure concentrations of odor at boundary area. So, we investigated the raising managements, manure managements, and methods of reducing odor according to farm scale. We found that concentration of ammonia gas in the swine fattening piggery in winter was the highest. This result is consistent with the lower ventilation rate to maintain Indoor temperature. In this result, there was no connection between farm scale and ventilating system. Concentration of ammonia gas was 1.64 ppm at one boundary area in the middle scale. $H_2S$, $CH_3SH$, $(CH_3)_2S$, and $(CH_3)_2S_2$ were below the standard of protection odor policy.

  • PDF

Preferences of Stroke Patients for Kitchen Environment in Residential Space (주거공간의 부엌 환경 특성에 대한 뇌졸중 환자의 선호)

  • Baek, Da-Rae;Jung, Yeon-Jin;Kang, Suk-Gu;Kim, Hee-Jung;Lee, Chun-Yeop
    • The Journal of Korean society of community based occupational therapy
    • /
    • v.4 no.2
    • /
    • pp.1-10
    • /
    • 2014
  • Objective : The purpose of this study was to investigate the preferences of kitchen environment for stroke patients. Methods : The subjects of this study were 97 who have experience in rehabilitation therapy at hospitals in Busan. A questionnaire was distributed and collected from February 24th to March 13th, 2014. Descriptive statistics of frequency Study were used to analyze data. Results : First, the subjects demand for improvement that use a chair for work and install non-slip tiles. Second, they preferred the non-slip mat, boilers in heating equipment, drawer storage, L-shaped safety handle, adjustable sink of the height, automatic cutout of gas leak, faucet of touch-sensitive type, ㄷ-shaped kitchen and the ceiling-type hood in ventilation system. Third, they need kitchen items such as the sink self coming down, scissors for slices and knife to avoid hand injury. Conclusion : This study would contribute to kitchen environment for fall prevention and ease in use.

  • PDF

Evaluation of thermal stress of poultry according to stocking densities using mumerical BES model (BES 수치모델을 이용한 사육 밀도별 가금류 고온 스트레스 평가)

  • Kwon, Kyeong-seok;Ha, Tahwan;Choi, Hee-chul;Kim, Jong-bok;Lee, Jun-yeob;Jeon, Jung-hwan;Yang, Ka-young;Kim, Rack-woo;Yeo, Uk-hyeon;Lee, Sang-yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.1
    • /
    • pp.456-463
    • /
    • 2019
  • Micro climatic conditions within the livestock facility are affected by various factors such as ventilation, cooling, heating, insulation and latent and sensible heat generation from animals. In this study, numerical BES method was used to simulate energy flow inside the poultry house. Based on the BES method and THI concept, degree of thermal stress of poultry was evaluated according to the locations in South Korea. Comparison of THI values within the poultry house was also carried out according to the stocking densities to reflect recent animal-welfare issue. Significant decrease in thermal stress of poultry was observed when the stocking density of $30kg/m^2$ was applied in the change of the seasons(p<0.05) however, there was no statistically significant difference in summer season(p>0.05). It meant that installation of proper cooling system is urgently needed. For Iksan city of Jeollabuk-do province, total 252 hours of profit for thermal stress was found according to decrease in the stocking density.

Estimation of GHGs Emission to Improvement of Facility Efficiency in the Food wastewater Treatment Process (식품폐수처리시설의 설비효율 개선에 따른 온실가스 배출량 평가)

  • An, Sang-Hyung;Song, Jang-Heon;Kim, San;Chung, Jin-Do
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.378-384
    • /
    • 2019
  • In the food wastewater treatment facilities, the water quality improvement effect and the greenhouse gas emission amount followed by the change in electricity usage through a change of the aeration tank ventilation system were evaluated. also, the amount of greenhouse gas emission followed by the change in electricity usage through the change of the sludge dewatering, storage, transporting method was also evaluated. The total GHG emission from food wastewater treatment facility improvement were divided into direct emissions from the treatment processes and indirect ones from electricity usage. The water quality improvement effect of wastewater treatment plant was found to be 63.3% for BOD removal rate, 42.0% for COD removal rate, 71.0% for SS removal rate and 39.6% for T-N removal rate. and according to the results of calculating output by applying both direct emissions of greenhouse gas (Scope 1) and the indirect emission (Scope 2) of greenhouse gas followed by changes in power consumption. It was estimated that there was a total of 276.0tCO2eq./yr(7.5%) greenhouse gas reduction effect from 3,668.8tCO2eq./yr before improvement to 3,392.8tCO2eq./yr after improvement. In this result is not due to the effects of water quality improvement of emission source, but because the reduction in electricity use has reduced the amount of greenhouse gas emissions.