• Title/Summary/Keyword: Ventilating

Search Result 226, Processing Time 0.028 seconds

Application of Heat Balance Model Design of Ventilating and Cooling Greenhouse (온실의 환기 및 냉방 설계를 위한 열평형 모델의 작용)

  • 남상운
    • Journal of Bio-Environment Control
    • /
    • v.9 no.4
    • /
    • pp.201-206
    • /
    • 2000
  • A certain system to overcome high temperature should be introduced for the stable year-round cultivation in greenhouses. There are efficient methods to overcome high temperature such as ventilation system with shading screen, fan and pad system with screen, and fog system with screen. This study was carried out to find a means to determine the capacity of such system. Heat balance equations for each system were established and verified by experimental results. The calculated ventilation rates from heat balance equations showed a good agreement with the measured ones. The evapotranspiration coefficient was the most important parameter affecting the ventilation requirement among input parameter affecting the ventilation requirement among input parameters except weather data. When the evaportanspiration coefficient increased 1%, the ventilation requirement decreased 1.3%. Therefore the data of evapotranspiration coefficient should be accumulated by various experiments, and then design standards and selection guidelines should be provided. The simulation results for same design conditions shown that air exchanges requirement and evaporating water of fan and pad system were 5.1∼7.7% and 6.8∼9.3% larger than those of fog system, respectively.

  • PDF

Concentration and Properties of Particulate Matters (PM10 and PM2.5) in the Seoul Metropolitan (서울시 지하철 시스템 내의 입자상물질(PM10, PM2.5) 농도 특성)

  • Lee, Tae-Jung;Lim, Hyoji;Kim, Shin-Do;Park, Duck-Shin;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.2
    • /
    • pp.164-172
    • /
    • 2015
  • Seoul subway plays an important part for the public transportation service in Seoul metropolitan area. As the subway system is typically a closed environment, frequent air pollution problems occurred and passengers get malhealth impact. Especially particulate matters (PM) is well known as one of the major pollutants in subway environments. The purpose of this study was to compare the concentrations of $PM_{10}$ and $PM_{2.5}$ in the Seoul subway system and to provide fundamental data in order to management of subway system. $PM_{10}$ and $PM_{2.5}$ samples were collected in the M station platform and tunnel of Subway Line 4 in Seoul metropolitan and in an outdoor location close to it from Apr. 21, 2010~Oct. 27, 2013. The samples collected on teflon filters using $PM_{10}$ and $PM_{2.5}$ mini-volume portable samplers and PM sequential sampler. The PM contributions were $48.6{\mu}g/m^3$ (outdoor), $84.6{\mu}g/m^3$ (platform) and $204.8{\mu}g/m^3$ (tunnel) for $PM_{10}$, and $34.6{\mu}g/m^3$ (outdoor), $49.7{\mu}g/m^3$ (platform) and $83.1{\mu}g/m^3$ (tunnel) for $PM_{2.5}$. The $PM_{10}$ levels inside stations and outdoors are poorly correlated, indicating that $PM_{10}$ levels in the metro system are mainly influenced by internal sources. In this study, we compared PM concentrations before and after operation of ventilation and Electrostatic Precipitator (EP). Despite the increased PM concentration at outdoor, $PM_{10}$ concentration at platform and tunnel showed the 31.2% and 32.3% reduction efficiency after operation the reduction system. The overall results of this study suggest that the installation and operation of the ventilating system and EP should have served as one of the important components for maintaining the air quality in the subway system.

A Study on $CO_2$ and PM10 Changes by Operation of KTX HVAC-Pressurization Equipment in Tunnel Sections (터널구간 운행시 KTX HVAC-여압장치 작동에 따른 $CO_2$와 PM10 변화연구)

  • So, Jin-Sub;Yoo, Seong-Yeon
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.6
    • /
    • pp.723-729
    • /
    • 2007
  • The Ministry of Environment established a guide line in December 2006, "Indoor Air Quality Management guidelines in Public Facilities." As the items of the guideline, $CO_2$ (Carbon dioxide) and PM10 (particulate matter) is shown to Level 1 and 2. Therefore trains and subways are included. There are a lot of tunnels by the lay of mountains on KTX (Korean Train Express) service. HVAC (Heating Ventilating and Air-conditioning)-pressurization equipment on KTX is various functioning flaps blocking outside pressure waves. At that time, the fresh air is blocked by flap operation and the air is circulated by return air. In this study, we measured the time series of $CO_2$ and PM10 concentrations in the KTX passenger cabin during the train service of Gyongbu line (Seoul-Busan) and Honan line (Yongsan-Mokpo) from July 2006. Also, analyzed the air quality by operation of KTX HVAC-pressurization equipment in tunnel passing point. As a result, PM10 concentration was totally lower than the regulation values. However, $CO_2$ was highly correlated with several tunnels, such as Oksan-Otan, Godeung-Hyudae and Gaechak-Iijik tunnel. but, the indoor air quality of KTX train have been proved satisfy the recommendation the Ministry of Environment guidelines.

Evaluation of Washing Efficiency of Collective PM by Electrostatic Precipitator in Subway Station Using Nano Bubble (나노버블을 이용한 지하철용 전기집진기 포집먼지에 대한 세척효율 평가)

  • Lee, Hyung-Don;Lee, Seung-Hwan;Park, Chan-gyu
    • Clean Technology
    • /
    • v.26 no.1
    • /
    • pp.13-21
    • /
    • 2020
  • Air pollutants in a subway are complexly caused by outdoor factors such as ventilating opening and indoor factors such as the movement of passengers on the subway. According to recent research results, most of the air pollutants generated in subway tunnels and stations are caused by indoor variables such as train movement. To control air pollutants such as particulate matter (PM), a prevention facility such as the electrostatic precipitator (EP) or bag filter collector was required in a subway station. In particular, the PM removed by the EP must be kept clean continuously to manage PM effectively. Therefore, a nano-bubbling washing system was developed in this study to clean a contaminated collecting plate in an EP at the main subway tunnel in Seoul. Removal efficiency compared with normal water and nano-bubbling water was likewise studied. As a result, the washing efficiency of collective PM increased in accordance with the increasing of injection pressure, with nano bubbling washing being 130.8% higher than tap water. According to increase in washing times, the maximum washing efficiency was 143.1% higher than tap water, but suitable washing times were less than 3 times. According to the results of the washing efficiency by variation of residence time, it was confirmed that the maximum residence time of nano-bubble water was maintained within 5 minutes.

A Study on the Activity of Health Management in Small Scale Industries (소규모 사업장 보건관리 지도내용 분석)

  • Kim Myung Soon;Lee Myung Sook;Kim Hyun Li;Cho Yoo Hyang
    • Journal of Korean Public Health Nursing
    • /
    • v.12 no.2
    • /
    • pp.12-26
    • /
    • 1998
  • The occupational health problems are the major issue in the modern industrial society. Especially the small scale industries have many hazardous factors and not any occupational health programs in itself. Fortunately. the government-funded subsidiary program was developed and carried out in the past six years in our country. The purposes of this study were to find out the actual condition of the occupational health personnel's accomplishments for the government-funded subsidiary program for small scale industries and to provide basic data for setting up more developed subsidiary occupational health program. Data were collected through 6 kinds of service records review. These service records were written by 3 occupational health personnels were attached to the one subject center of KIHA. were undertaken during March to December, 1997. at 95 small scale industries which were applied the government-funded subsidiary occupational health program. Results were as follows 1. Concerning 95 small scale industries showed characteristics of a typical small scale industry. 2. A doctor visited in industries total 190 times per year, average 19 industries per month, twice per year and industry. A hygienist visited in industries total 378 times per year, average 38 industries per month, four times per year and industry. A nurse visited in industries total 477 times per year. average 47 industries per month, 5 times per year and industry. 3. 3 occupational health personnels accomplished total 3,869 items. A doctor accomplished total 539 items per year, each time 3 items In an industry. A hygienist accomplished total 1.581 items per year, each time 4 items in an industry. A nurse accomplished total 1.749 items per year, each time 4 items in an industry. 4. The major contents of doctor's accomplishment were 'health consultation for suspicious worker with general & occupational disease', 'a check of the workplace & special health education', 'guidance of special medical examination in the second half of year', etc. The major contents of hygienist's accomplishment were 'pretest & guidance of planning for evaluation of working environment'. 'evaluation for ventilating facilities & suporting self inspection', 'guidance of MSDS recording & chemicals management', etc. The major contents of nurse's accamplishment were 'health counseling of general & special medical examination results'. 'health education of preventing occupational disease & health disorder'. 'guidance of subsidiary program planning', 'selecting & guidance of health monitor', etc. It was concluded that the occupaional health personnels implemented the subsidiary program according to the order of health management guide. The current health management guide of subsidiary occupational health program in which the fixed contents, visiting number & periods is not desirable. That guide is left the characteristics of small scale industries out of consideration. It is suggested that occupational health management guide should be developed according to the general & environmental characteristics of each small scale industry, and on the other hand, the more specific guide for each occupational health personnel should be developed.

  • PDF

Effect of Covering Method of Ventilating Non-Woven Fabric and $\textrm{GA}_3$ Treatment on the Growth and Yield of Leaf Lettuce during Low Temperature Season (통기성 부직포의 피복방법 및 $\textrm{GA}_3$ 처리가 저온기에 잎상추의 생육 및 수량에 미치는 영향)

  • 최영환;손병구;강점순;안종길
    • Journal of Bio-Environment Control
    • /
    • v.12 no.2
    • /
    • pp.72-76
    • /
    • 2003
  • This study was conducted to estimate stimulation of plant growth of green and red leafy lettuces (Lactuca sutiva L. cv. Chungchima and Jugchima) at affected by covering method and time with protected film materials containing concentrated PO film and GA$_3$ foliar spray. Plants were covered with ‘Pasraido’ material from October 26 to November 31 (direct 1), from November 5 to November 31 (direct 2), or with a tunnel, or direct 2+ tunnel. Mean air temperature and relative humidity under the covering were higher in direct and tunnel, direct and non-covering, in that order. The fresh weight and dry weight of red and green lettuces increased in direct and tunnel followed by direct 1, direct 2, tunnel and the control. GA$_3$ treatment promoted the growth in all covering methods, but decreased the chlorophyll contents. Fresh weight and dry weight were higher in red lettuce than in green lettuce in the control.

Development on Glass Formulation for Aluminum Metal and Glass Fiber (유리섬유 및 알루미늄 금속 혼합물 유리조성 개발)

  • Cho, Hyun-Je;Kim, Cheon-Woo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.10 no.4
    • /
    • pp.247-254
    • /
    • 2012
  • Vitrification technology has been widely applied as one of effective processing methods for wastes generated in nuclear power plants. The advantage of vitrifying for low- and intermediate-level radioactive wastes has a large volume reduction and good durability for the final products. Recently, a filter using on HVAC(Heating Ventilating & Air Conditioning System) is composed with media (glass fiber) and separator (aluminum film) has been studied the proper treatment technology for meeting the waste disposal requirement. Present paper is a feasibility study for the filter vitrification that developing of the glass compositions for filter melting and melting test for physicochemical characteristic evaluation. The aluminum metal of film type is preparing with 0.5 cm size for proper mixing with glass frit, glass fiber is also preparing with 1 cm size within crucible. The glass compositions should be developed considering molten glass are related with wastes reduction. Glass compositions obtained from developing on glass formulation are mainly composed of $SiO_2$ and $B_2O_3$ for aluminum metal. A variety of factors obtained from the glass formulation and melting test are reviewed, which is feeding rate and glass characteristics of final products such as durability for implementing the wastes disposal requirement.

Effects of Growth Regulators and Culture Environment on ex vitro Rooting and Acclimatization of Apple Rootstock in vitro Propagated (기내배양 사과 대목의 기외 삽목 시 발근과 순화에 미치는 배양조건 및 생장조절물질의 효과)

  • Kwon, Soon-Il;Kim, Jeong-Hee;Kang, In-Kyu;Kim, Mok-Jong
    • Journal of Plant Biotechnology
    • /
    • v.31 no.2
    • /
    • pp.133-138
    • /
    • 2004
  • Growth of M.9 (Malus domestica Bark. cv) and M.26 (Malus domestica Bark. cv) of dwarf apple rootstock, cultured on MS agar medium in a vessel with ventilating stopper (VS) and then in vivo rooting and acclimatization under combined-treatment by some materials with IBA, were investigated. Concentration of $CO_2$ and ethylene in the vessel with VS was lower then in the vessel with non-VS. Change of temperature and humidity in the vessel with VS was repeated by light condition. Stomatal pares of tissue in the vessel with VS were immediately closed after plantlets were exposed to room humidity but those in the vessel with non-VS were opened after 20 minutes exposure to room humidity. Leaf area and chloroplast index of tissue in the vessel with VS was higher then in the vessel with non-VS. In vivo rooting ratio and acclimatization ratio of M.9 and M.26 was highest in 300mg/L IBA+3% sucrose dip-treatment among other combined- treatments.

Effect of Row Covers on the Growth and Yield of Broccoli During Spring Culture (막덮기 재배가 봄재배시 녹색꽃양배추의 생육 및 수량에 미치는 영향)

  • 이정수;이재욱;성기철
    • Journal of Bio-Environment Control
    • /
    • v.11 no.4
    • /
    • pp.175-180
    • /
    • 2002
  • This study was conducted to examine the effect of row covering materials on the growth and yield of broccoli for early production in the open meld. Materials for plastic tunnel were row-covering (ventilating non-woven fabric), perforated film (2.3% pore space) and P.E. film. The types of row covers were tunnel and covering period was one months after transplanting. The row cover and perforated film increased daily air and soil temperature by 3~4$^{\circ}C$ and 2~3$^{\circ}C$, respectively as compared to no covering. Also, relative humidities in those treatments were higher than those in P.E. and no covering. The row covering and perforated film enhanced plant growth. Broccoli grew best and abnormal head appeared the least with row covering treatment. Days taken for head formation, however, did not differ between treatments but the weight of curd was over 400 g in the treatment of row covering and perforated film covering. Marketable yield doubled under row covering as compared to no covering. The first harvest time was earlier by two weeks in row-covering. The results of this experiment indicated that covering row-cover film in spring cultivation was effective fer not only yield increase but also quality evaluation in early production of broccoli.

Computational Analysis on the Noise Characteristics of Ship Large Duct (선박용 대형 덕트의 소음 특성 전산해석 연구)

  • Song, Jee-Hun;Hong, Suk-Yoon;Lee, Yi-Soo;Kwon, Hyun-Wung
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.6
    • /
    • pp.751-758
    • /
    • 2015
  • Noise prediction for HVAC(Heating, Ventilating and Air Conditioning) systems are normally performed by empirical method suggested by NEBB(National Environmental Balancing Bureau, 1994). However, the method is not suitable for large ducts in ships. In this paper, computational analysis methods are used to develop a noise prediction method for the large ducts in ships. To develop regression formula of attenuation of sound pressure level in large ducts, Boundary Element Method(BEM) is used. BEM and Computational Fluid Dynamics(CFD) are applied to the analysis of flow-induced noise in ducts with stiffeners inside. Loud noise above 100 dB can be generated in some cases. Breakout noises of large ducts are also analyzed by using BEM and Finite Element Method(FEM). The acoustic pressure level shows about 10-15dB difference between inside and outside of the duct. Utilizing the results of this study, it is expected that shipyard planners can predict noise of the HVAC system for ships.