• 제목/요약/키워드: Vent control

검색결과 84건 처리시간 0.022초

LNG Vent Mast의 풍하중/지진하중 해석에 관한 연구 (A Study of Wind/Earthquake Load Analysis for LNG Vent Mast)

  • 김태욱;조수길;박상현;오재원;이정희;배상은;김형우
    • 한국산업융합학회 논문집
    • /
    • 제23권2_2호
    • /
    • pp.343-349
    • /
    • 2020
  • As global warming accelerates due to global climate change, the International Maritime Organization(IMO) has set up Emission Control Area(ECA) and encourages the use of Liquefied Natural Gas(LNG). For this reason, as the demand for LNG increases, the demand and research of related equipment also increases. In this study, one of them, the vent mast for the discharge of LNG was studied. In general, vent mast receives various loads such as wind load, earthquake load and dead load during operation. Accordingly, consideration of these loads is essential for structural design and safety evaluation of the vent mast. In this study, the structural safety of the vent mast is evaluated by performing finite element analysis. As a result, the structural safety evaluation results were analyzed based on the database of materials of the vent mast, and the stress level was analyzed to provide a design guide.

파이프 비닐온실용 권취식 창개폐기의 개발 (Development of roll - up ventilation system for pipe- constructed plastic film greenhouse)

  • 이기명;박규식;김유일;김태홍
    • 생물환경조절학회지
    • /
    • 제4권2호
    • /
    • pp.232-239
    • /
    • 1995
  • This study was carried out to get required torque data needed to design and develop a roll-up ventilation system in a pipe-constructed plastic film green-house. The results obtained from this study are as follows : 1. The required torques of a roll-up ventilation system in greenhouse are the functions of its length. The torques should multiplied by the conversion coefficients (2.0 in ceiling vent, 1.8 in side vent) in case of application. 2. In constructing pipe-constructed plastic film greenhouse, a shaft pipe is the largest essential element in roll - up shaft weight constitution which have an effect on the required torques. Therefore, the pipe should be light using nonferrous materials like aluminum alloy. 3. A planetary reduction ventilator of differential ring gear type is suitable for a roll-up ventilation system, because it can make high efficient reduction just using the first step shift.

  • PDF

연동형 비닐하우스의 환기창 형태 조사 및 자연환기 효과 분석 (Field Survey and Analysis of Natural Ventilation Characteristics of Multi-span Greenhouse with Different Roof Vent)

  • 박민정;최덕규;손진관;윤성욱;김희태;이승기;강동현
    • 생물환경조절학회지
    • /
    • 제29권1호
    • /
    • pp.36-42
    • /
    • 2020
  • 본 연구에서는 국내에 가장 많이 보급되어 있는 1-2W 모델 연동온실에 대한 온실 규격 및 환기창 형태 실태 조사를 수행하고, 이를 바탕으로 연동온실의 천창 형태에 따른 유동 특성을 분석하기 위해 수치해석을 수행하여 자연환기효과를 분석하고자 하였다. 온실 실태조사 대상농가의 환기창면적 비율은 평균10%로 자연환기를 위한 시설면적 대비 환기창 면적 설계가 부족한 것으로 나타나 환기창 개선이 필요할 것으로 판단된다. 연동 온실의 천창 형태별 자연환기를 해석 및 분석한 결과, 온실 내 작물위치의 온도 분포 및 내외부 온도차는 몽골식 천창 온실에서 가장 낮고 외몽골식 천창 온실에서 가장 높게 나타났으나 추후 풍하중에 의한 구조적인 안전성을 평가해야할 것으로 판단된다.

동승석 최고 충돌성능 달성을 위한 액티브 벤트 에어백 기술 개발 (A Development of Active Vent Airbag for the Passenger New NCAP)

  • 유재행;신효섭;김태인;배한일;이성우
    • 자동차안전학회지
    • /
    • 제5권1호
    • /
    • pp.31-36
    • /
    • 2013
  • For the robust passenger NCAP 5star and the stable neck injury performance, a new concept of passenger airbag has been required strongly. Especially, the deployment stability and the vent hole control technology of the passenger airbag should be improved. According to these requirements, the deployment stability technique has been studied and the 'Active Vent' technology has been developed. As a result, these technologies have led to achieve the robust NCAP rating and are applied to the production vehicles.

국내외 물류창고의 자연배연기준 비교에 관한 연구 (A Study on the Comparison of Natural Ventilation Standards for Domestic and Foreign Logistics Warehouses)

  • 김윤성;최윤주;허예림;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 봄 학술논문 발표대회
    • /
    • pp.67-68
    • /
    • 2022
  • Foreign countries stipulate that ventilation and smoke control facilities are installed in logistics warehouses. On the other hand, in Korea, the design guidelines and standards of ventilation and smoke control facilities for logistics warehouses are not clear even in the situation where the number of human casualties caused by smoke has increased until recently. Accordingly, the smoke descent time according to the vent was calculated. As a result, when there was no vent, the smoke descent time was 369s. On the other hand, when the vent was installed, smoke did not fall because the amount of smoke was greater than the amount of smoke generated.

  • PDF

CFD 검증을 위한 풍동 및 PIV를 이용한 자연환기식 온실 내부 공기유동 분석 (Analysis on Internal Airflow of a Naturally Ventilated Greenhouse using Wind Tunnel and PIV for CFD Validation)

  • 하정수;이인복;권경석;하태환
    • 생물환경조절학회지
    • /
    • 제23권4호
    • /
    • pp.391-400
    • /
    • 2014
  • The number of large scale greenhouses has recently been increasing to cope with mass consumption of agricultural product. Korean government announced a new development plan for constructing greenhouse complex in reclaimed lands for the purpose of improvement in exports and activation of domestic market of agricultural product. Wind environment in the reclaimed land is totally different from that of inland area, and it can give a strong influence on ventilation performance of naturally ventilated greenhouse facilities. In this study, internal airflow analysis of naturally ventilated greenhouse built on a reclaimed land was conducted using wind tunnel and PIV for validation research. Later, the PIV measured results will be used to improve the accuracy of 3 dimensional CFD simulation in the future. Wind profile at a reclaimed land was produced using ESDU program and it was applied to the wind tunnel. The calculated error was only 5% and 0.96 of correlation coefficient, implying that the computed profiles were designed properly. From the measured results, when external wind speed changed from $1m{\cdot}s^{-1}$ to $1.5m{\cdot}s^{-1}$, air velocities inside the greenhouse which PIV measured were also increased proportionately in case of both side vent open and side-roof vent open. Considering reduced ratio of air velocity inside the greenhouse, it was measured a minimum of 40% in case of side vent and 30% in case of side-roof vent compared with external wind speed from each vent type. From the quantitative and qualitative PIV analysis, the PIV measured results indicated that there were well ventilated and stagnant areas in the greenhouse according to external wind condition as well as ventilation design.

영상정보를 이용한 가스벤트자동교환 장치 (A study on the development of Gas-Vent Automatic Exchange Machine with Vision System)

  • 권장우;홍준의;윤동업;길경석;이동훈;노태정
    • 한국정보통신학회논문지
    • /
    • 제11권6호
    • /
    • pp.1141-1149
    • /
    • 2007
  • 본 논문에서는 신발금형의 가스벤트 착탈 작업을 효율적으로 진행하기 위해 이미지 프로세싱을 통한 가스벤트 착탈위치 탐색과 정밀 제어로 착탈 작업을 수행하는 교환 장치의 두 가지 기술을 다루고 있다. 이 두가지 방법을 적용하기 위한 핵심적인 이슈는 신발 금형의 가스벤트 교환 위치의 중심을 어떻게 하면 정확하게 찾아내는가이다. 이러한 자동 교환 장치의 사용은 가스벤트 착탈 시간을 줄이며 아울러 노동력의 절감 제품의 생산에 드는 비용을 최소화하는 등의 여러 가지 이점을 가져다 준다. 이 장치를 사용하여 실험을 통해 검증한 결과 가스벤트 교환 장치의 사용이 더 안정적이고 효율적이며 착탈 시간을 줄여 공정시간을 단축하는 것을 증명할 수 있었다.

전산유동해석을 이용한 ORIFICE 방출 계수 예측 (PREDICTION OF THE ORIFICE DISCHARGE COEFFICIENT USING COMPUTATIONAL FLUIDS DYNAMICS)

  • 옥호남;김인선
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2006년도 추계 학술대회논문집
    • /
    • pp.147-150
    • /
    • 2006
  • Vent ports are installed on the walls of closed compartments of a launch vehicle to control the pressure drop in the compartments. The ports can be modelled as an orifice, and the accurate prediction of the discharge coefficient of an orifice is essential for the design of vent ports. Experimental methods have been used to determine the discharge coefficients for various shapes of orifices, and extensive databases are available. Wind tunnel tests have been also done to evaluate the effect of interaction between venting outflow and freestream for limited conditions. The goal of the present research is to predict the discharge coefficient of an orifice using CFD and evaluate the accuracy of the method, especially for the orifices exposed to the external flow.

  • PDF

환기창 자동제어용 제어 알고리즘 개발 (Development of a Control Algorithm for Automatic Ventilation)

  • 박규식;이기명
    • 생물환경조절학회지
    • /
    • 제6권4호
    • /
    • pp.242-249
    • /
    • 1997
  • 현대화 온실이 농가에 보급 된지 5년째를 맞고 있지만 환경조절을 위한 자동화 설비의 이용현황은 외국으로부터 수입된 일부 유리온실을 제외하고는 당초 목적한 성능과 기술에 이르지 못하고 있어 그 이용율이 아주 저조하다. 이것은 농민의 자동화 장치 이용기술 부족 때문이기도 하지만 자동화 장치의 하드웨어 및 소프트웨어가 농민에 의한 수동스위치 조작보다 제어 성능이 따르지 못한 것이 주된 이유라고 생각된다. 이에 본 연구는 지금까지 외국기술에 의존하거나 이용율이 낮은 원예시설의 환경조절자동제어 시스템을 국내 기술에 의해 생산 보급할 수 있도록 성능이 우수하고 적응성이 높은 시스템 개발을 위하여 수행한 연구결과를 요약하면 다음과 같다. 1. 온실의 고온관리를 위한 온실내외의 온도차를 함수로하여 창개례순서, 1회 개폐폭, 제어주기 둥을 결정하는 알고리즘을 개발하여, 제어프로그램을 작성하였으며 시스템을 운전하여 본 결과 제어성능이 우수하였다. 2. 파이프비닐온실에는 시스템의 설치 및 A/S의 편리성 등을 감안하여 각 환경요인별로 개별제어 할 수 있도록 시스템화하는 것이 바람직하다고 판단되었다. 3. 시스템의 실용화를 위하여 제어항목 중 관수, 탄산가스 농도, 커덴개폐는 타이머를 이용한 시퀀스제어로 하였다. 4. DSP칩을 이용하여 고온제어를 위한 창개폐제어 시스템을 실용화할 수 있도록 개발하였다. 5. 온실의 자동제어시스템과 연결되어 있는 전화를 통하여 관리자가 부재 중 온실의 과고온, 정전, 고장 둥 비상발생시 관리자에게 무선호출을 할 수 있는 경보시스템을 개발하였다.

  • PDF

지붕 환기팬이 설치된 단동 플라스틱 온실에서 개선된 측창형태가 하우스 내 온도 및 참외 수량에 미치는 영향 (Effects of an Improved Side Vent on Yield of Oriental Melon and Temperature in Single-span Plastic Greenhouse with Roof Ventilation Fans)

  • 유인호;조명환;류희룡;신영안
    • 생물환경조절학회지
    • /
    • 제26권4호
    • /
    • pp.283-290
    • /
    • 2017
  • 본 연구에서는 저온기에 참외재배 단동 플라스틱 온실에서 지붕 환기팬을 이용하여 환기할 때 작물에 스트레스를 적게 주면서 바깥 공기를 하우스 내부로 균일하게 유입할 수 있는 방법으로 하우스 전체길이에 대해 측창안쪽부분에 비닐을 부착하는 방법을 개발하였다. 지면으로부터 측창이 최대한 열렸을 때 높이의 10cm 아래까지 비닐을 설치하였다. 측창 개선에 의한 온실 환경 개선 및 참외 수량증대 효과를 검증하기 위하여 개선 측창형태와 관행의 측창형태를 비교하였다. 2017년 2월 25일 까지는 두 시험구 모두 환기를 하지 않았는데, 2월 중순 하우스 내 기온이 $40^{\circ}C$를 넘어섰다. 따라서 2월 중순부터는 하우스 환기를 시작해야 할 것으로 판단된다. 대조구에서의 기온이 4월 하순부터 $30^{\circ}C$를 넘어섰다. 그러므로 측창 안쪽에 부착한 비닐을 4월 하순, 늦어도 5월 상순에는 제거해야 할 것으로 판단된다. 4월 중순에 처리구에서의 지온은 생육 적온 범위인 $20^{\circ}C$를 넘어선데 비해 대조구에서는 여전히 $20^{\circ}C$보다 낮게 나타났다. 4월 하순이 되어서야 대조구의 지온도 $20^{\circ}C$를 넘어서는 것으로 나타났다. 전기사용량은 처리구 47.2kWh, 대조구 48.3kWh로 처리 간에 큰 차이를 보이지 않았다. 처리구에서의 참외 상품수량은 5,094kg으로 대조구 4,113kg에 비해 23.9% 많았다. 상품과율은 처리구 73.5%, 대조구 73.9%로 차이가 없었다.