• Title/Summary/Keyword: Venous return

Search Result 75, Processing Time 0.019 seconds

Automatic Control System on Cardiac Output Regulation for the Moving Actuator Type Total Artificial Heart (MOVING-ACTUATOR TYPE 인공심장의 심박출 조절에 대한 자동 제어방법)

  • 김원곤
    • Journal of Chest Surgery
    • /
    • v.28 no.6
    • /
    • pp.542-548
    • /
    • 1995
  • The goal of this study is to develop an effective control system for cardiac output regulation based upon the preload and afterload conditions without any transducers and compliance chambers in the moving actuator type total artificial heart. Motor current waveforms during the actuator movement are used as an input to the automatic control algorithm. While the current waveform analysis is performed, the stroke length and velocity of the actuator are gradually increased up to the maximum pump output level. If the diastolic filling rate of either right or left pump begins to exceed the venous return, atrial collapse will occur. Since the diastolic suction acts as a load to the motor, this critical condition can be detected by analyzing the motor current waveforms. Every time this detection criterion is met, the control algorithm decreases the stroke velocity and length of the actuator step by step just below the critical detection level. Then, they start to increase. In this way the maximum pump output under given venous return can be achieved. Additionally the control algorithm provides some degree of afterload sensitivity. If the aortic pressure is detected to exceed 120 mmHg, the stroke length and velocity decrease in the same way as the response to the preload. Left-right pump output balance is maintained by proper adjustment of the asymmetry of the stroke angle. In the mock circulatory test, this control system worked well and there was a considerable range of stroke volume difference with adjustment of the asymmetry value. Two ovine experiments were performed. It was confirmed that the required cardiac output regulation according to the venous return could be achieved with adequate detection of diastolic function, at least in the in vivo short-term survival cases[2-3 days . We conclude that this control algorithm is a promising method to regulate cardiac output in the moving actuator type total artificial heart.

  • PDF

Total Anomalous Pulmonary Venous Return: Report of 3 Cases (총폐정맥환류이상:3례 수술 보고)

  • Ahn, Hyuk;Hong, Jang-Soo;Rho, Joon-Ryang;Lee, Yung-Kyoon
    • Journal of Chest Surgery
    • /
    • v.14 no.1
    • /
    • pp.40-48
    • /
    • 1981
  • Total anomalous venous return defines a group of congenital heart disease which have in common the entire pulmonary venous drainage returning directly or indirectly to the right atrium instead of to the left atrium. Despite of recent advance in treatment, this severe malformation in its various anatomical forms has a high surgical mortality during early infancy. Because of the high mortality in the untreated infant and the surgical risk in the first year of life, the timing of the operation remains important for optimal result. Three cases of T APV R, two supracardiac types and one mixed type, were treated with extracorporeal circulation during last three years in the Dept. of Thoracic and Cardiovascular Surgery, Seoul National University Hospital. The first one was 10 months old male with supracardiac type which drained through left innominate vein, and he was operated with profound hypothermia and total circulatory arrest but failed. The second case was 7 years old male with supracardiac type drained through left innominate vein, and he was well post operatively, and followed periodically for 12 months. The third case was 24 years old female with mixed type drainage (left upper pulmonary vein drained through left innominate vein, and the others through coronary sinus) was successfully corrected, and she was followed for 4 month without problem. All cases were diagnosed with cardiac catheterization and angiocardiogram, and also with echocardiogram in last two cases. In first two cases of supracardiac type, total circulatory arrest was used in brief period during anastomosis between common pulmonary venous trunk and left atrium. In the last case of mixed type, usual cardiopulmonary bypass with moderate hypothermia was used and total circulatory arrest was not needed.

  • PDF

Analysis of 174 Consecutive Free Flaps (유리피판 이식술 174예의 분석)

  • Tark, Kwan Chul;Roh, Tai Suk
    • Archives of Reconstructive Microsurgery
    • /
    • v.9 no.1
    • /
    • pp.15-22
    • /
    • 2000
  • One hundred & seventy four consecutive free-flap transfers were reviewed to analyze distribution of the type of reconstructions, kinds of donor flaps as well incidence of complications. The role of emergent exploration and the effect of preoperative wound conditions in flap survival were evaluated. Free flap transfer for head and neck reconstruction was most common as 93 cases, followed by for upper extremity of 30 cases, for lower extremity 30 cases, 18 penile reconstructions and for trunk & breast 3 cases. Nine flaps exhibited signs of ciruclatory insufficiency between 5 hours and 7 days. Three were managed conservatively with ultimate partial necrosis of the flaps. Eight flaps required return to the operating room. On exploration, early arterial occlusion was revealed in 1 flap, late arterial occlusion in 2 flaps, early venous occlusion in 1 flap, late venous thrombosis in 2 flaps, prolonged venous spasm in 1 and hematoma in 1 flap. The average time from the first abnormal examination to exploration was 2.6 hours. There were no false-positive explorations. Four free flaps failed in spite of the correction of the cause of circulatory compromise. The remaining 4 flaps were salvaged following the correction the casuse. Recipient vessel problems such as irradiation and infection were the most common cause of circulatory crisis. Among the eight flaps requiring return to the operating room, single vein was anastomosed in three flaps and two veins in the remaining five. In the totally failed four flaps only single vein was anastomosed in three cases. The results of this study demonstrate the efficacy of clinical monitoring and the role of early exploration. Precautious selection of recipient vessels and two vein anastomosis are recommended for safe and better prognosis.

  • PDF

Partial Anomalous Pulmonary Venous Drainage Associated with Septal Defect in Dextrocardia (우심증에서 부분 폐정맥 이상환류를 동반한 심방중격결손 -1례 보고-)

  • Chang, M.;Chang, B.C.;Cho, B.K.;Hong, S.N.
    • Journal of Chest Surgery
    • /
    • v.12 no.1
    • /
    • pp.30-32
    • /
    • 1979
  • Partial anomalous pulmonary drainage is frequently accompanied by an atrial septal defect. The anomaly is entirely compatible with life and the clinical findings are dependent primarily on the proportion of the pulmonary venous return to the right atrium. The anomaly is frequently missed even with complete diagnostic study. In this report we are presenting a case of anomalous pulmonary venous drainage combined with atrial septal defect and dextrocardia and the treatment of this condition.

  • PDF

Malignant Schwannoma in Neurofibroma with or without Neurofibromatosis - 3 Cases Report - (신경섬유종 (Neurofibroma) 환자에서 발생한 악성 Schwannoma -3예 보고-)

  • Kim, H.;Lee, D.Y.;Cho, B.K.;Hong, S.N.;Kim, S.K.;Cho, N.H.
    • Journal of Chest Surgery
    • /
    • v.21 no.6
    • /
    • pp.1103-1110
    • /
    • 1988
  • We experienced 1 year old female patient with partial anomalous pulmonary venous return of the right lung into the inferior vena cava with atrial septal defect. Total anomalous venous drainage from the right lung is an uncommon form of congenital defect, and it may or may not be associated with an atrial septal defect. One patient having this venous anomaly is presented with a detailed description of the surgical reconstruction used. The postoperative result has been satisfactory.

  • PDF

Outcomes of the Warden Procedure for Anomalous Pulmonary Venous Return to the Superior Vena Cava: A 17-Year Experience

  • Lim, Su Chan;Kwak, Jae Gun;Cho, Sungkyu;Min, Jooncheol;Lee, Sangjun;Kwon, Hye Won;Kim, Woong-Han
    • Journal of Chest Surgery
    • /
    • v.55 no.3
    • /
    • pp.206-213
    • /
    • 2022
  • Background: Surgical repair of partial anomalous pulmonary venous return (PAPVR) to the superior vena cava (SVC) using the Warden procedure has favorable outcomes. However, there remain some concerns after the Warden procedure, such as sinoatrial nodal dysfunction and systemic or pulmonary venous stenosis. We investigated the outcomes of the Warden procedure for repair of PAPVR to the SVC. Methods: This retrospective study included 22 consecutive patients who underwent the Warden procedure for PAPVR between 2002 and 2018. The median age and body weight at operation were 27.5 months (interquartile range [IQR], 5.0-56.8 months) and 13.2 kg (IQR, 6.5-16.0 kg), respectively. The median follow-up duration was 6.2 years (IQR, 3.5-11.6 years). Results: There were no cases of early or late mortality. No patients had postoperative heart rhythm problems, except 1 patient who showed transient sinoatrial nodal dysfunction in the immediate postoperative period. Procedure-related complications requiring reintervention occurred in 5 patients, including 3 of 4 SVC stenosis cases and 2 pulmonary venous stenosis cases during follow-up. The rate of freedom from reintervention related to the Warden procedure was 75.9% at 10 years. Conclusion: In cases requiring extension or creation of an atrial septal defect to achieve a sufficient venous pathway, or interposition of an entire circumferential conduit between the SVC and right atrium due to the shortness of the SVC in the Warden procedure, stenotic complications of the venous pathway occurred. Careful observation of changes in the pressure gradient or anatomical stenosis is required in such patients.

Surgical Repair of Inferior Sinus Venosus Defect - A Report Four Cases- (하정맥동형 심방중격결손의 외과적처지 -4례 보고-)

  • 최형호;김천석;윤향석;최종범;최순호
    • Journal of Chest Surgery
    • /
    • v.31 no.2
    • /
    • pp.168-172
    • /
    • 1998
  • Inferior sinus venosus defect is a rare lesion in which there is a large interatrial communication adjacent to the atrial connection of the inferior caval vein. The defect is located posteriorly and inferiorly, outside the confines of the true atrial septum, and partial anomalous pulmonary venous connections are the rule. We underwent surgical repair in four patients with inferior sinus venosus defect and partial anomalous pulmonary venous return. There were three males and one female with an age range from four months to 25 years. A cross- sectional echocardiogram and cardiac catheterization had been performed preoperatively in all patients, but the correct diagnosis had been made in only one case. Surgical repair was indicated due to congestive heart failure, and one patient of 4-month-old needed urgent operation. The repair was accomplished by suturing a untreated autologous pericardial patch to the right of the pulmonary veins, so that the defect was closed and all the pulmonary venous blood was directed to the left atrium. The preoperative knowledge of the unusual anatomy allows the surgeon to repair the anomaly without difficulties. For the patients in whom interatrial communication and anomalous pulmonary venous return are suggested, surgeon has to pay careful attention to the anatomical landmarks to avoid incorrect placement of the patch.

  • PDF

Extracorporeal Membrane Oxygenation in a 1,360-g Premature Neonate after Repairing Total Anomalous Pulmonary Venous Return

  • Rhee, Youn Ju;Han, Sung Joon;Chong, Yoo Young;Kang, Min-Woong;Kang, Shin Kwang;Yu, Jae-Hyeon
    • Journal of Chest Surgery
    • /
    • v.49 no.5
    • /
    • pp.379-382
    • /
    • 2016
  • With advancements in complex repairs in neonates with complicated congenital heart diseases, extracorporeal membrane oxygenation (ECMO) has been increasingly used as cardiac support. ECMO has also been increasingly used for low birth weight (LBW) or very low birth weight (VLBW) neonates. However, since prematurity and LBW are risk factors for ECMO, the appropriate indications for neonates with LBW, especially VLBW, are under dispute. We report a case of ECMO performed in a 1,360-g premature infant with VLBW due to cardiopulmonary bypass weaning failure after repairing infracardiac total anomalous pulmonary venous return.

Effects of Hypovolemic Hypotension on Cardiopulmonary Functions and Acid-Base Balance (출혈성 쇼크가 심폐기능 및 산.염기평형에 미치는 영향)

  • Sou, Won-Young;Lee, Sung-Haing
    • Journal of Chest Surgery
    • /
    • v.6 no.2
    • /
    • pp.131-142
    • /
    • 1973
  • Studies of cardiopulmonary function and acid-base balance were performed on 29 dogs during control period, during oligemic hypotension and following return of blood to the animals. Intravenous morphine and local anesthesia were used. Fifteen of the 29 animals survived the complete experiment. The 14 animals that failed to survive the experimental period died between 15 to 90 minutes after the onset of bleeding. The results were as follows. 1. The heart rate increased after the onset of bleeding and failed to return to control level following reinfusion. Stroke volume decreased markedly after bleeding and failed to recover after return of blood from the reservoir. Cardiac output also decreased during oligemic hypotension and was maintained at this level after re-infusion. Total peripheral resistance decreased significantly immediately after bleeding, however it increased soon over the pre-bleeding level. Central venous pressure decreased after the onset of bleeding and remained at lower level for the rest of the experimental period. Arterial blood pressure, clown to 40-45 mmHg by acute hemorrhage, was elevated near to control level. Left ventricular work decreased tremendously during oligemic hypotension and failed to return to control level with the re-infusion of blood. Hematocrit value showed no significant decrease after bleeding and increased after re-infusion. Hemoglobin decreased after the onset of bleeding and recovered to control value after re-infusion. 2. The respiratory rate fell rapidly after bleeding from 124 to 29 and remained at this lower level for the remainder of the experiment. The tidal volume increased after bleeding and was maintained at this level for the remainder of the experiment. The respiratory minute volume showed no significant changes throughout the experimental period. Oxygen consumption fell lightly in all animals during oligemic hypotension and returned to normal levels following re-infusion. Arterial oxygen content and arterial oxygen saturation decreased following bleeding and the values returned to normal levels after the return of blood from the reservoir The arterio-venous oxygen difference increased after the onset of bleeding. It failed to return to normal values following re-infusion. Arterial $Pco_2$ decreased in all animals after the beginning of the bleeding. Partial pressure of $Co_2$ continued to fall until re-infusion, after which the values returned toward normal. Animals became acidotic. The pH fell to lower level following bleeding. Lactic acid and lactate: pyruvate ratio also increased during same period. Arterial pH and lactic acid failed to return to control value and lactate: pyruvate ratio increased more after re-infusion. Sodium bicarbonate decreased after bleeding and returned to control value following re-infusion.

  • PDF

Effect of Deep Breathing Exercise and Ankle Exercise on Blood Flow Velocity in the Femoral Vein (심호흡 운동과 발목관절 운동이 대퇴정맥의 혈류속도에 미치는 영향)

  • Jung, Do-Young;Kim, Young;Kwon, Oh-Yun
    • Physical Therapy Korea
    • /
    • v.9 no.2
    • /
    • pp.107-113
    • /
    • 2002
  • This study was conducted to determine the effects of deep breathing exercise and ankle exercise on blood flow velocity in the femoral vein. Sixteen healthy male students were recruited from Yonsei University, at Wonju. The blood flow velocities in the femoral vein were measured under three different conditions: resting, deep breathing, and ankle exercise. All subjects were given a 5-minute relaxing time in supine position prior to the study. Using a doppler ultrasound with a 8 MHz probe, the peak blood flow velocities were collected in a twenty-second-period at each condition. The subjects took a rest in between trials for the blood flow to return to its resting levels. The result showed a significant difference in peak blood flow velocities under those three conditions (p<.001). The peak blood flow velocity was highest in ankle exercise condition. The peak blood velocity was significantly higher in deep breathing condition compared with the resting condition. As a result, it is revealed that not only the muscular contractions but also the deep breathing exercises induced facilitating effects of venous return. Either of the exercise methods can be recommended to prevent blood stasis in patients with risk of deep vein thrombosis after cardiac or lower extremity surgery.

  • PDF