• Title/Summary/Keyword: Venetian blind system

Search Result 15, Processing Time 0.023 seconds

Optimum Control of a Photoelectric Dimming System in a Small Office with a Double Skin Envelope

  • Kim, Soo Young;Yum, Sung Kon
    • Architectural research
    • /
    • v.7 no.2
    • /
    • pp.47-54
    • /
    • 2005
  • A photoelectric dimming control system for a small private office space with a double skin envelope system was analyzed for the purpose of examining optimum control performances under a variety of daylight conditions. Computer simulations were performed for the three different photosensor types positioned at the center of ceiling in the space. They were applied in both a south and north-facing room. Daylight conditions were a fixed horizontal venetian blind on an external envelope and a retractable shading device on an internal envelope under a clear, intermediate and overcast sky at different times of a day and year. Partially-shielded photosensors provided good control performances providing the required electric light output under clear and intermediate sky conditions. Unshielded photosensors failed to provide necessary illuminance levels producing less electric output and fully-shielded photosensors generally provided excessive light output. Reasonable electric lighting energy savings were achieved except under overcast sky conditions where the control system did not contribute to energy savings due to the less daylight through envelopes. The retractable shading device covering 50% of the internal envelope reduced energy savings up to 19.62%, but the workplane illuminance levels were maintained within recommended ranges. The coefficients of determination between workplane illuminance and photosensor illuminance due to daylight ranged from 0.74 to 0.98. Partially-shielded conditions provided best correlations and the north-facing room yielded stronger correlation than the south-facing room.

An Evaluation of Indoor Thermal Environment for Zero-Carbon Green Home according to the Operation Conditions in Summer (제로카본 그린홈의 여름철 운영조건에 따른 실내 열환경 평가)

  • Yu, Jung yeon;Cho, Dong woo;Kim, Kee Han
    • Journal of the Korean Solar Energy Society
    • /
    • v.40 no.2
    • /
    • pp.25-36
    • /
    • 2020
  • The Korean government has a plan to mandate zero-energy buildings in 2020 for public and 2025 for private buildings. In order to design a zero-energy building, insulation and airtightness, which are the most basic elements of passive house technology, are required, and the government has been accomplished this through step-by-step strengthening of related standards. In passive house with high thermal insulation and airtightness performance, the heat introduced into the building through solar radiation can be stored for a long time to keep the inside warm during winter. On the other hand, during summer, heat introduced into the building cannot be easily released to outside, so it is necessary to actively block solar radiation and high temperature outdoor air to prevent an increase of indoor temperature. Therefore, this study aims to derive an appropriate operation condition of passive house to maintain the indoor temperature at an suitable level according to the ventilation methods and solar shading conditions. As a result, under the conditions that the outdoor temperature was 28℃ or less, the ventilation using a heat recovery ventilation system at daytime and natural ventilation at nighttime were selected for the most appropriate operation method. In addition, in the case of solar shading, it was found that blocking solar radiation at daytime using the blind and open the blind at nighttime to ensure natural ventilation were selected for the most appropriate solar shading condition.

Evaluation on the Characteristics of Daylight Distributions of Grating Louver System in a Pair Glass by Computer Simulation (복층유리 격자루버시스템의 주광특성에 관한 시뮬레이션 평가)

  • Park, Byoung-Chul;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.12
    • /
    • pp.1-9
    • /
    • 2009
  • A recent research trend on the Daylight Responsive Dimming Systems, using available daylight for energy savings, is to integrate automated roller shading systems and venetian blind systems which are vertically controlling daylight to indoor based on sun profile angle. Therefore, this paper suggests Grating Louver System into a pair glass as a new shading system, which can control daylight vertically and horizontally. The optimized spacing of louvers, which is to block direct sunlight into a space, was calculated. And then, the system was simulated for analysis and evaluation of characteristics of daylight by Desktop Radiance 2.0.

Analysis on Dimming Control Effect by Algorithm Variation for Direct/Indirect Lighting in a Small Office (알고리듬 변화에 따른 직/간접 조명시스템에 대한 디밍제어 효과분석)

  • Kim, Soo-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.5
    • /
    • pp.36-48
    • /
    • 2008
  • This study examines the influence of control algorithms on dimming performance to determine appropriate control setting when direct/indirect lighting is controlled by a daylight dimming system. Computer simulation were performed for a small office with double skin envelope under various daylight conditions. A retractable fabric shading and Venetian blind were applied for internal and external envelopes under three CIE standard sky conditions. Unshielded and partially-shielded photosensors were used, and three control algorithms were applied for the sensors. In general, dimming level was too excessive due to the direct impact of light from lighting fixture to the photosensor. Providing insufficient lighting output, the unshielded photosensor completely failed to secure required illuminance under any daylight condition. When a partially-shielded photosensor was applied under clear sky, three setting points functioned effectively. Less sensitivity for the partially-shielded photosensor was effective to control the dimming system optimally with reasonable energy saving. However, the daylight dimming control system for direct/indirect lighting does not appear to be energy effective when photosensors without enough shielded area is installed on ceiling where light from fixtures reaches directly.

An Architectural Study on the Improvement of Energy Efficiency of Public Institution - Focused on Public Office Buildings Remodeling of Passive Design Elements - (공공기관 에너지 효율등급 향상을 위한 적용 설계요소에 관한 연구 - 공공청사 리모델링시 패시브 디자인요소를 중심으로 -)

  • Cho, Jung-Chul;Park, Jae-Seung
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.4
    • /
    • pp.114-120
    • /
    • 2012
  • There are lots of buildings which were built before the Legislation on building energy rating system. Remodeling of the buildings would be required for an improvement of the building energy rating system was enforced by the government. In the Passive Building Design, Elements which will be used for the remodeling are Insulation, Window, External venetian blind, Heat exchanger. The Purpose of this study is to indicate a Method for the improvement of Energy saving by an analysis of Construction Cost, Cost Evaluation, Energy performance Efficiency in applied design elements. In this study, the remodeling of existing public buildings to improve energy efficiency rating was applied to extract the elements of design-specific energy performance, efficiency, and the application of the designs that has been analyzed. The results were as follows: applying the design-specific cost-effective investment that represents the economy (investment efficiency/%) surveyed the average insulation(7.0%), triple glazed windows(10.1%), double glazed windows(12.1%), external shading(24.5%), and Heat(77.2%) were analyzed in order to be more efficient. Analysis of the basis of information on the existing public buildings to improve energy efficiency rating for the remodeling depending on driving conditions at a degree of individual difference. The main effect, however, depending on economic investment, design elements, heat exchangers, external awning, double glazed windows, triple glazed windows, insulation, is recommended as review of the order shall be determined.

  • PDF