• Title/Summary/Keyword: Venetian Blinds

Search Result 16, Processing Time 0.026 seconds

Analyzing Shading Characteristics of Venetian Blinds Using the RADIANCE Program (RADIANCE 프로그램을 이용한 베네치안 블라인드의 차양특성 분석)

  • Song, Kyoo-Dong;Kim, Min-Sung;Kim, Ji-Hyun
    • KIEAE Journal
    • /
    • v.5 no.3
    • /
    • pp.3-9
    • /
    • 2005
  • Venetian blinds are used with windows to improve the uniformity ratio of illuminance and interior daylighting distribution under direct sunlit conditions. The main objective of Venetian blinds shading system is to obstruct direct sunlight and at the same time allow daylight to penetrate into the room. Venetian blinds would have greater effect on the interior daylighting condition under clear sky which has both skylight and sunlight than overcast sky which has only skylight. However, due to the lack of data, design and evaluation tools, it is difficult for architects to choose or install venetian blinds during the building design stages. The purpose of this study was to develop an analysis method for shading and daylighting effects of Venetian blinds using the RADIANCE program. The major variables related to the venetian blinds included blinds's slat angle and the ratio of slat width to window height, the radius slat of curvature and the building azimuth. In this study, a series of parametric physical mock-up model measurements and genblinds command in the RADIANCE simulations. The results of this study will provide building designers with the design data at early design stages.

An Analysis on Building Energy Reduction Effect of Exterior Venetian Blind According to Orientation and Reflectance of Slat (블라인드형 외부차양의 종류 및 반사율에 따른 건물에너지 저감효과 분석)

  • Kim, Jin-Ah;Yoon, Seong-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.2
    • /
    • pp.28-34
    • /
    • 2013
  • It is essential to reduce building energy consumption in office building because government enact policy which encourages building energy certification from 2013. Office building has high cooling energy demand due to large glazed area of facade in these days. Shading devices can be an alternative of reducing high cooling energy demand. So, this study simulated a variety of exterior venetian blinds to know how much building energy be affected by orientation and reflectance of slat. The results of this study are based on Seoul weather data. The following is a summary of this study. 1) As a slat of venetian blinds has the lower reflectance, the more building energy reduced. Reflectance is usually affected by color and material of slat. In case reflectance is 0.2 reduce 4% of building energy than reflectance is 0.8. 2) Horizontal exterior venetian blinds are more effective than vertical exterior venetian blinds in all of orientation. Horizontal shape is average 16% more effective in shading effect than vertical shape. 3) In this case study, the most effective shading device is low reflectance horizontal exterior venetian blinds that result about 18% building energy reduction than no shade model. The results of this research can be used to plan shading devices for energy conservative office building.

An Experimental Study on Comparing Solar Heat Shading Performances in Accordance with the Type of Internal Blinds in the Summer (하절기 내측 블라인드의 유형별 일사차폐성능 비교 실측연구)

  • Park, Eun-Mi;Choi, Dong-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.4
    • /
    • pp.1-9
    • /
    • 2016
  • The purpose of this study was to compare heat shading performance of various blind types in summer. 4 types of blinds were employed and the results are summarized as follows: 1) There were significant differences in indoor thermal environment and heat shading performance between different heat shading devices, and functional blinds demonstrated relatively superior heat shading performance. 2) Indoor long wave radiation influx measures were lowest for the coating roll blind (Blind B), followed by the coating venetian blind (Blind C), the venetian blind (Blind A), the roll blind, and not having any blinds at all. 3) Such examination results carry implications to reduce cooling load and enhance the indoor environment.

Optimized slat angle control algorithm prediction of venetian blind depending on window orientation for energy saving (건물에너지 저감을 위한 향별 슬랫형 블라인드의 최적각도 제어 알고리즘 산출)

  • Kwon, Hyuk-Ju;Lee, Keum-Ho;Lee, Kwang
    • KIEAE Journal
    • /
    • v.17 no.3
    • /
    • pp.99-106
    • /
    • 2017
  • Purpose: Most modern office buildings adopt the curtain wall system in order to provide occupants with the sense of openness and high-technology, which requires large window area. As a result, the amount of solar radiation increases, negatively affecting cooling load during the summer and increasing energy costs. However, the performance of window itself is not sufficiently controllable parameter to control thermal comfort and solar radiation. Therefore, a shading device such as venetian blind is required to control them and thus a variety of studies have been performed thus far. So, the purpose of this study is to improve the performance of blind through the development of blind control algorithm. Method: Among various input variables for the control of venetian blinds, the vertical solar radiation has been selected in this study as the primary input variable and the optimal control algorithm for venetian blinds were developed for each window orientation. Result: The developed optimal control algorithm has a positive effect on building energy savings.

The Summer Cooling and Lighting Energy Performance Evaluation of Small Office Buildings with Venetian Blinds (블라인드를 고려한 여름철 소규모 사무소 건물의 냉방 및 조명에너지 평가)

  • Chung, Yu-Gun
    • KIEAE Journal
    • /
    • v.13 no.1
    • /
    • pp.39-45
    • /
    • 2013
  • The daylighting control system has to be applied to prevent the excessive incident daylight and reduce energy use. As the one of the most useful daylighting control systems, the blind system is simple and easy to install on the window for small office buildings. This study aims to evaluate the summer energy performance of small office buildings by venetian blinds and energy saving strategy of ministry of knowledge economy in korea. For the study, the simulations have been executed on blind installation conditions and lighting control methods. As results, the energy loads cut down 22 to 25(%) by using blind energy. Also, the efficient shows high on EMS system and low on $45^{\circ}$ slat angles. Also, using energy saving strategy can reduce about 13(%) energy load.

An Experimental Study on Indoor Thermal Characteristics in accordance with the Use of Windows and Blinds in Double Skin Facade in Summer (이중외피에서 창문 개폐 및 블라인드 설치에 따른 하절기 실내 열환경 특성 변화 실험 연구)

  • Kim, Dong-Kyun;Yoon, Kap-Chun;Kang, Jae-Sik;Kim, Kang-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.1
    • /
    • pp.59-67
    • /
    • 2011
  • This paper is focused on the effect of indoor temperature rise according to the use of windows and blinds in double skin facade in summer. For the experiment, we set up the mock-up of double skin facede and measuring temperature and solar radiation. Total 7 cases were used for measuring solar transmittance and indoor temperature rise. When the venetian blind was not installed, solar transmittance was 44.5%, and solar transmittance for the case that installed the venetian blind (angle 0) was 22.5%. Cases that opened inner and outdoor windows for ventilation showed lower indoor temperature rise than cases with closed windows. In addition, Case 5 (opened inner and outdoor windows with the venetian blind (angle 0) to reduce solar transmittance) indicated lower indoor temperature rise than Case 3(opened inner and outdoor windows). Consequently, Case 5 which uses inner and outdoor window for ventilation and venetian blind to reduce solar transmittance is the most effective way to reduce indoor temperature rise among all cases tested in this research.

A Study on the Change of Indoor Thermal Environment According to the location of Blinds (블라인드 설치 위치에 따른 실내열환경 변화에 관한 연구)

  • Hwang, Deuk-Soo;Lee, Kyung-Hee
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.5
    • /
    • pp.113-118
    • /
    • 2011
  • In order to prevent incoming solar radiation, it is necessary to study about blinds' blocking out effects of heat that are installed at the balcony at an apartment house. To figure out the heating effects from the windows, a study for indoor thermal environment according to the location of blinds is also needed. In order to find out the changes of indoor thermal environment, we'll compare models of a house building with or without Venetian blinds: one place has an extended living room removing a balcony and another one has a normal balcony. The result is as follows. Without blinds, the place with an extended living room has benefits for saving heat compare to the place with a normal balcony. It's because the warm air heated by the incoming solar radiation moves into the living room through convection current and radiation which causes an increase of the indoor temperature. At an extended living room, the temperature difference from outside and inside, when blinds were installed inside, was $1.9^{\circ}C$ while it was $0.6^{\circ}C$ when the blinds were installed at outside of the balcony. It is evaluated that setting up the blind outside prevents much heat. At the space with a normal balcony, installing blinds at living room windows can save much heat compare to installing blinds at windows at the balcony. The indoor temperature was low when blinds were installed. It can be said that blinds block heat from the incoming solar radiation. Moreover, when blinds are installed, there is a big change of indoor temperature due to the radiation from the blinds' slat and convective activities in between the blinds and windows. This also has to be considered.

Comparing Solar Heat Shading Performances of Internal Blinds in the Summer (내측 블라인드의 하절기 일사열 차폐 성능 비교)

  • Park, Eun-Mi;Choi, Dong-Ho;Park, Min-Yong;Lee, Kyung-Hee
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.6
    • /
    • pp.75-83
    • /
    • 2014
  • Heat loss through windows and doors occupies 20 to 45% of the total heat loss in building. It accounts for a large proportion of the total heat loss in building. In order to suppress the amount of heat flow through the windows and doors were considered actions such as reinforcement of insulation performance of window, adoption of low-e glass, and installation of solar heat shading device. The Purpose of this study is to compare solar heat shading performances of 3 types of internal blinds in the summer. In order to verify the solar heat shading performances of the blinds, a roll blind, blind A(Venetian blind) and blind B(Daylight guiding venetian blind)were installed in the four rooms with the same environmental conditions. As a result of the experiment, the blind B, blind A, roll blind showed an excellent performance in that order. Its because the blind B is made of aluminum materials coated with special paints on surface. It doesn't converted to long wave by short wave light. and it is reflected to short wave to outside.

A Study on the Characteristics of Daylighting Environment in Classroom of an School Building Due to the External Shading Devices (학교 건물에서 외부 차양 장치 유형에 따른 일반교실 내 빛환경 특성에 관한 연구)

  • Lim, Jae-Han;Jung, Jin-Ju;Lee, Ji-Young
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.15 no.2
    • /
    • pp.4-15
    • /
    • 2008
  • The purpose of this study was to evaluate the characteristics of daylighting environment in classroom of an school building due to the external shading devices such as fixed louvers, light shelves and exterior venetian blinds. In this study, we have made a field research with regard to the facade design in classroom of an school building. And we have made a classification of external shading devices considering the design parameters. Finally, through RADIANCE simulation, we have calculated the spatial distribution of illuminance, uniformity ratio of illuminance and daylight factors. The results of this study will provide the building designer with the basic daylighting performance data at early design stages.

The prediction of reduction ranges of daylight illuminance in small office for sky and shading conditions (천공 및 차양조건에 따른 소규모 사무실의 주광 조도 감소범위 예측)

  • Jang, Seo Yeon
    • Land and Housing Review
    • /
    • v.10 no.3
    • /
    • pp.33-41
    • /
    • 2019
  • This study examines the distributions of daylight illuminance in a small office space under clear and cloudy sky conditions. Three shading conditions using Venetian blinds were applied for the analysis of daylight illuminance. Computer simulations using the Lightscacpe were conducted for the daylight conditions applied to the office space. Results indicate that the illuminance differences between clear and cloudy sky for south-facing conditions were greater than those for north-facing conditions. The differences in December and June were the greatest and smallest, respectively. For the north-facing conditions, the daylight illuminance at 10:00, 12:00 and 14:00 in June and September under the cloudy sky was higher than those under the clear sky conditions. For all daylight conditions, the biggest amount of illuminance reduction occurred when the shading device conditions were changed from the no blind to the 45 degree blinds. As the distance from window increased, the shading effect that occurred when the shading device conditions were changed from the horizontal blind to the 45 degree blinds increased.