Development of Velocity Imaging Method for Motility of Left Ventricle in Gated SPECT (게이트 심근 SPECT에서 좌심실의 운동성 분석을 위한 속도영상화 기법 개발)

  • Jo, Mi-Jung;Lee, Byeong-Il;Choi, Hyun-Ju;Hwang, Hae-Gil;Choi, Heung-Kook
    • Journal of Korea Multimedia Society
    • /
    • v.9 no.7
    • /
    • pp.808-817
    • /
    • 2006
  • Although the generally used the velocity index of doppler effect is a very significant factor in the functional evaluation of the left ventricle, it depends on the subjective evaluation of an inspector. The objective data of the motility can be obtained from the gated myocardial SPECT images by quantitative analysis. However, it is difficult to image visual of the velocity of the motion. The aim of our study is to develop a new method for the imaging velocity using the gated myocardial SPECT images and use it as an evaluation index for analyzing motility. First we visualized left ventricle into 3 dimensions using the coordinates of the points which were obtained through a segmentation of myocardium. Each point was represented by the different colors, according to the velocity of each point. We performed a validation study using 7 normal subjects and 15 myocardial infarction patients. To analyze motility, we used the average of the moved distance and the velocity. In normal cases, the average of the moved distance was 4.3mm and the average of the velocity was 11.9mm. In patient cases, the average of the moved distance was 3.9mm and the average of the velocity was 10.5mm. These results show that the motility of normal subjects is higher than the abnormal subjects. We expect that our proposed method could become a way to improve the accuracy and reproducibility for the functional evaluation of myocardial wall.

  • PDF

Development of X-ray PIV Technique and Its Applications (X-ray PIV 기법의 개발과 적용연구)

  • Lee Sang Joon;Kim Guk Bae;Kim Seok;Kim Yang-Min
    • Journal of the Korean Society of Visualization
    • /
    • v.3 no.1
    • /
    • pp.20-25
    • /
    • 2005
  • An x-ray PIV (Particle Image Velocimetry) technique was developed fur measuring quantitative information on flows inside opaque conduits and/or opaque-fluid flows. To check the performance of the x-ray PIV technique developed, it was applied to a liquid flow in an opaque Teflon tube. To acquire x-ray images suitable for PIV velocity field measurements, the refraction-based edge enhancement mechanism was employed with seeding detectable tracer particles. The amassed velocity field data obtained were in a reasonable agreement with the theoretical prediction. The x-ray PIV technique was also applied to get velocity fields of blood flow and to measure size and velocity of micro-bubbles simultaneously, and to visualize the water refilling process in bamboo leaves. The x-ray PIV was found to be a powerful transmission-type flow imaging technique fur measuring quantitative information of flows inside opaque objects and various opaque-fluid flows.

  • PDF

Mechanical Behavior of the Soleus Aponeuroses during Voluntary Contraction Using Magnetic Resonance Imaging Technique (자기공명 영상기법을 이용한 인체 가자미근 건막의 기계학적 특성 연구)

  • Lee, Hae-Dong
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.1
    • /
    • pp.121-127
    • /
    • 2007
  • Muscle force produced by muscle fibers is transmitted to bones via tendinous structures(aponeuroses and tendon), resulting in joint(s) movement. As force-transmitting elements, mechanical behavior of aponeuroses and tendon are closely related with the function of muscle-tendon complex. The purpose of this study was to determine strain characteristics of aponeuroses for in-vivo human soleus muscle during submaximal voluntary contractions using an advanced medical imaging technique, velocity-encoded phase-contrast magnetic resonance imaging (VE-PC MRI). VE-PC MRI of the soleus muscle-tendon complex was acquired during submaximal isometric plantarflexion contraction-relaxation cycle (n = 7), using 3.0T Trio MRI scanner(Siemens AG, Malvern, MA). From the VE-PC MRI containing the tissue velocity in superior-inferior direction, twenty regions of interest(20 ROI; 10 on the anterior aponeurosis and 10 on the posterior aponeurosis) were tracked. During the isometric plantarflexion contraction-relaxation cycle, velocity and displacement profiles were different between the anterior and posterior aponeuroses, indicating heterogeneous strain behavior along the length of the leg. The anterior aponeurosis elongated while the posterior aponeurosis shortened during the initial phase of the contraction. Moreover, strain behavior of the posterior aponeurosis was different from that of the Achilles tendon. Possible explanation for the observed variations in strain behavior of aponeuroses was investigated with morphological assessment of the soleus muscle and it was found that the intramuscular tendinous structures significantly vary among subjects. In conclusion, the heterogeneous mechanical behavior of the soleus aponeuroses and the Achilles tendon suggests that the complexity of skeletal muscle-tendon complex should be taken into consideration when modeling the complex for better understanding of its functions.

Study of Acoustic Streaming at Resonance by Longitudinal Ultrasonic Vibration Using Particle Imaging Velocimetry (입자 영상 유속계를 이용한 초음파 수직진동에 의해 유도된 공진상태에서의 음향유동에 관한 연구)

  • 노병국;이동렬
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.5
    • /
    • pp.340-352
    • /
    • 2004
  • Acoustic streaming induced by the microscopic longitudinal ultrasonic vibration at 28.5 ㎑ is visualized between the quiescent glass plate and ultrasonic vibrator by particle imaging velocimetry(PIV) using laser. To investigate the augmentation of air flow velocity of acoustic streaming. the velocity variations of air streaming between the stationary plate and ultrasonic vibrator are measured in real-time. It is experimentally investigated that the magnitude of the acoustic streaming dependent upon the gap between the ultrasonic vibrator and stationary p1ate results in the variations of the average velocity fields as a outcome of the bulk air flow caused by the ultrasonic vibration. In addition. maximum acoustic streaming velocity exists at resonant gap. 18mm that is one of the resonant gaps (H=18, 24, 30, 36㎜) at which resonance occurs. The variation of the local maximum turbulent intensity with axial direction appear to reveal the value of 8%∼70% dependent upon the gap between the quiescent glass plate and ultrasonic vibrator. Shearstress is also maximized at the center region of the vibrator and the vorticity is also maximum and minimum in the neighborhood of the center of the vibrator at which the local maximum turbulent intensity and shear stress exist.

Left Atrial Velocity Vector Imaging Can Assess Early Diastolic Dysfunction in Left Ventricular Hypertrophy and Hypertrophic Cardiomyopathy

  • Se-Jung Yoon;Sungha Park;Eui-Young Choi;Hye-Sun Seo;Chi Young Shim;Chul Min Ahn;Sung-Ai Kim;Jong-Won Ha
    • Journal of Cardiovascular Imaging
    • /
    • v.31 no.1
    • /
    • pp.41-48
    • /
    • 2023
  • BACKGROUND: The function of left atrium (LA) is difficult to assess because of its ventricle-dependent, dynamic movement. The aim of this study was to assess LA function using velocity vector imaging (VVI) and compare LA function in patients with hypertrophic cardiomyopathy (HCMP) and left ventricular hypertrophy (LVH) with normal controls. METHODS: Fourteen patients with HCMP (72% male, mean age of 52.6 ± 9.8), 15 hypertensive patients with LVH (88% male, mean age of 54.0 ± 15.3), and 10 age-matched controls (83% male, mean age of 50.0 ± 4.6) were prospectively studied. Echocardiographic images of the LA were analyzed with VVI, and strain rate (SR) was compared among the 3 groups. RESULTS: The e' velocity (7.7 ± 1.1; 5.1 ± 0.8; 4.5 ± 1.3 cm/sec, p = 0.013), E/e' (6.8 ± 1.6; 12.4 ± 3.3; 14.7 ± 4.2, p = 0.035), and late diastolic SR at mid LA (-1.65 ± 0.51; -0.97 ± 0.55; -0.82 ± 0.32, p = 0.002) were significantly different among the groups (normal; LVH; HCMP, respectively). The e' velocity, E/e', and late diastolic SR at mid LA were significantly different between normal and LVH (p = 0.001; 0.022; 0.018), whereas LA size was similar between normal and LVH (p = 0.592). The mean late diastolic peak SR of mid LA was significantly correlated with indices of diastolic function (E/e', e', and LA size). CONCLUSIONS: The SR is a useful tool for detailed evaluation of LA function, especially early dysfunction of LA in groups with normal LA size.

Development of a GUI Crosswell Seismic Tomography Software on Linux (리눅스용 GUI 시추공 탄성파 토모그래피 프로그램 개발)

  • Sheen Dong-Hoon;Ko Kwang Beom;Park Jae-Woo;Ji Jun;Lee Doo-Sung
    • Geophysics and Geophysical Exploration
    • /
    • v.5 no.3
    • /
    • pp.150-156
    • /
    • 2002
  • In this study, a software for crosswell seismic tomography is developed. The software consists of first arrival picking and adjusting module, crosswell traveltime tomography module, and imaging module. This software allows saying the picked first arrival times into the header of seismic data, and using this data directly to the input of crosswell seismic tomography. With an imaging module, velocity structures and ray path can be imaged directly from the output of the tomography module. Because it is developed on the basis of the SU under the Linux and the GUI environment for user, this software can be carried out directly the first arrival picking, inversion and tomogram for crosswell tomography data in the field. Therefore, this software can be improved the applicability of site investigation by tomography method.

Cerebrospinal fluid flow in normal beagle dogs analyzed using magnetic resonance imaging

  • Cho, Hyunju;Kim, Yejin;Hong, Saebyel;Choi, Hojung
    • Journal of Veterinary Science
    • /
    • v.22 no.1
    • /
    • pp.2.1-2.10
    • /
    • 2021
  • Background: Diseases related to cerebrospinal fluid flow, such as hydrocephalus, syringomyelia, and Chiari malformation, are often found in small dogs. Although studies in human medicine have revealed a correlation with cerebrospinal fluid flow in these diseases by magnetic resonance imaging, there is little information and no standard data for normal dogs. Objectives: The purpose of this study was to obtain cerebrospinal fluid flow velocity data from the cerebral aqueduct and subarachnoid space at the foramen magnum in healthy beagle dogs. Methods: Six healthy beagle dogs were used in this experimental study. The dogs underwent phase-contrast and time-spatial labeling inversion pulse magnetic resonance imaging. Flow rate variations in the cerebrospinal fluid were observed using sagittal time-spatial labeling inversion pulse images. The pattern and velocity of cerebrospinal fluid flow were assessed using phase-contrast magnetic resonance imaging within the subarachnoid space at the foramen magnum level and the cerebral aqueduct. Results: In the ventral aspect of the subarachnoid space and cerebral aqueduct, the cerebrospinal fluid was characterized by a bidirectional flow throughout the cardiac cycle. The mean ± SD peak velocities through the ventral and dorsal aspects of the subarachnoid space and the cerebral aqueduct were 1.39 ± 0.13, 0.32 ± 0.12, and 0.76 ± 0.43 cm/s, respectively. Conclusions: Noninvasive visualization of cerebrospinal fluid flow movement with magnetic resonance imaging was feasible, and a reference dataset of cerebrospinal fluid flow peak velocities was obtained through the cervical subarachnoid space and cerebral aqueduct in healthy dogs.

In Vivo Visualization of Flow in Xylem Vessels of a Bamboo Using X-ray Micro-imaging Technique (X-ray 미세영상기법을 이용한 식물 목질부 내부 수액 유동의 계측)

  • Kim, Yang-Min;Lee, Sang-Joon
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1693-1696
    • /
    • 2004
  • Synchrotron X-ray micro-imaging technique was employed to monitor non-invasively the refilling process of water inside the xylem vessels in bamboo leaves. The consecutive phase-contrast X-ray images clearly show both plant anatomy and the transport of water inside the xylem vessels. Traces of water-rise, vapor bubbles and variations of contact angle between the water front and the xylem wall were measured in real time. During the refilling process, air bubbles are removed when the rising water front halts at a vessel end for a while. Subsequently, it starts rising again at a higher velocity than the normal refilling speed. Repeated cavitation seems to deteriorate the refilling ability in xylem vessels. In dark environment, the water refilling process in xylem vessels is facilitated more effectively than in bright illuminated conditions. Finally, X-ray micro-imaging was famed to be a powerful, high resolution, real time imaging tool to investigate the water refilling process in xylem vessels.

  • PDF

Velocity Field Masking Technique for Coastal Engineering Experiments

  • Adibhusana, Made Narayana;Ryu, Yong-Uk
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.154-154
    • /
    • 2021
  • Since the development of Bubble Image Velocimetry (BIV) technique as the complementary technique of Particle Image Velocimetry (PIV), the application of digital imaging technique in the field of hydraulic and coastal engineering increased rapidly. BIV works very well in multi-phase flow (air-water) flows where the PIV technique doesn't. However, the velocity field obtained from BIV technique often resulted in a velocity vector on the outside of the flow (false velocity) since the Field of View (FOV) usually not only cover the air-water flow but also the area outside the flow. In this study, a simple technique of post processing velocity field was developed. This technique works based on the average of the pixel value in the interrogation area. An image of multi-phase flow of wave overtopping was obtained through physical experiment using BIV technique. The velocity calculation was performed based on the similar method in PIV. A velocity masking technique developed in this study then applied to remove the false velocity vector. Result from non-masking, manually removed and auto removed false velocity vector were presented. The masking technique show a similar result as manually removed velocity vector. This method could apply in a large number of velocity field which is could increase the velocity map post-processing time.

  • PDF