• Title/Summary/Keyword: Velocity Correlation

Search Result 1,140, Processing Time 0.031 seconds

A study on a development of a measurement technique for diffusion of oil spill in the ocean (디지털 화상처리에 의한 해양유출기름확산 계측기법개발에 관한 연구)

  • 이중우;김기철;강신영;도덕희
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 1998.10a
    • /
    • pp.211-221
    • /
    • 1998
  • A digital image processing technique which is able to get the velocity vector distribution of a surface of the spilled oil in the ocean without contacting the flow itself. This technique is based upon the PIV(Particle Imaging Velocimetry) technique and its system mainly consists of a high sensitive camera, a CCD camera, an image grabber, and a host computer in which an image processing algorithm is adopted for velocity vector acquisition. For the acquisition of the advective velocity vector of floating matters on the ocean, a new multi-frame tracking algorithm is proposed, and for the acquisition of the diffusion velocity vector distribution of the spilt oil onto the water surface, a high sensitive gray-level cross-correlation algorithm is proposed.

  • PDF

Measurement of Flow Field in a Domestic Boiler Circulation Pump by PIV (PIV에 의한 가정용보일러용 순환펌프의 내부 유동장 계측)

  • Im, Y.C.;Kim, J.H.;Choi, M.S.;Lee, Y.H.
    • Journal of Power System Engineering
    • /
    • v.3 no.2
    • /
    • pp.13-19
    • /
    • 1999
  • The purpose of the present experimental study is to apply multi-point simultaneous measurement by PIV(Particle Image Velocimetry) to high-speed flow region within a domestic boiler circulation pump. Two different kinds of flow rate($27{\ell}/min,\;19{\ell}/min$)are selected as experimental condition. A volute casing and Impeller made of transparent Polycarbonate were made for the easy access of the illumination laser via fiber optical line and cylinder lens assembly to the measuring region. A CCD camera is syncronized with AOM to acquire clear original particle images. Optimized cross correlation identification to obtain velocity vectors is implemented by direct calculation of correlation coefficients. The instantaneous and time-mean velocity distribution, velocity profile and kinetic energy are represented quantitatively at the full-scale region for the deeper understanding of the unsteady flow characteristics in a commercial circulation pump.

  • PDF

Development of a High Power SONAR System Measuring Velocity by Using Two Gated Sinusoidal Signals (두 개의 정현 신호를 이용한 속도 측정용 고전력 쏘나 시스템 개발)

  • 장순석;안흥구;이제형
    • Journal of KSNVE
    • /
    • v.9 no.5
    • /
    • pp.1036-1041
    • /
    • 1999
  • This paper aims for the development of the high power sonar system for measuring the velocity of a moving object. The high power sonar system transmits two gated 190 kHz sinusoidal signals with 1.6 [ms] time interval to the moving object. Then the sonar system detects and calculates the changed time delay of the reflected ultrasonic signals in order to derive the velocity of the moving object. The transmission part uses a high power amplifier so that 250 W gated sinusoidal signals can be transmitted to the transmitter. 1M RAM is utilized for transmitting and storing of the ultrasonic signals. The time delay is calculted by the cross-correlation technique between the transmitted signals and the received signals. The measured value from the high power sonar system is compared with directly measured values by photo diodes. The result confirms the adjacency to 0.3% error.

  • PDF

A Study on a Development of a Measurement Technique for Diffusion of Oil Spill in the Ocean (디지털 화상처리에 의한 해양유출기름확산 계측기법개발에 관한 연구)

  • 이중우;강신영;도덕희;김기철
    • Journal of Korean Port Research
    • /
    • v.12 no.2
    • /
    • pp.291-302
    • /
    • 1998
  • A digital image processing technique which is able to be used for getting the velocity vector distribution of a surface of the spilt oil in the ocean without contacting the flow itself. This technique is based upon the PIV(Particle Imaging Velocimetry) technique and its system mainly consists of a high sensitive camera, a CCD camera, an image grabber, and a host computer in which an image processing algorithm is adopted for velocity vector acquisition. For the acquisition of the advective velocity vector of floating matters on the ocean, a new multi-frame tracking algorithm is proposed, and for the acquisition of the diffusion velocity vector distribution of the spilt oil onto the water surface, a high sensitive gray-level cross-correlation algorithm is proposed.

  • PDF

A Numerical Study on the Burning Velocity of LFG Mixing Gas (LFG(Landfill Gas) 혼합가스의 연소속도에 대한 수치해석적 연구)

  • 정익산;오창보;이창언
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1999.11a
    • /
    • pp.171-180
    • /
    • 1999
  • In this study, the burning velocity of LFG and LFG mixing fuels related with flame stabilization have been analyzed numerically using C3 reaction mechanism which consists of 92 species and 621 reaction for using LFG. The results show that the burning velocities of LFG and LFG mixing fuels are obtained as a function of CH$_4$ and LFG percent in stoichiometric conditions. Also, a correlation of the burning velocities LFG and LFG mixing fuels are obtained over a wide range of equivalence ratio. The comparison of burning velocity from correlation with that calculated numerically show good agreements. From these results, the proposed burning velocity correlations for LFG and LFG mixing fuels can be applied for the practice of LFG.

  • PDF

Correlation between Weight Bearing Ratio and Functional Level for Development of Pressure Sensor Biofeedback in Stroke Patient

  • Moon, Young;Kim, Mi-Sun;Choi, Jong-Duk
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.9 no.3
    • /
    • pp.315-324
    • /
    • 2014
  • PURPOSE: This study aimed to determine the correlation of weight bearing ability at the affected side with balance and gait abilities for the development of pressure biofeedback based equipment to stroke patients. METHODS: This study included 35 patients with stroke patient. The tests were conducted to determine the weight bearing ratio while pushing a step forward the affected side, static balance ability using the total length of COP(Center of pressure), sway velocity of COP, COP velocity at the X and Y axis. Functional reaching test (FRT), berg balance scale (BBS) were used to assess the dynamic balance ability and timed up and go test (TUG), 10m walk test (10mWT) were used assess the gait ability respectively. In order to determine the correlation between measured variables, bivariate correlation analysis was conducted. RESULTS: A significant correlation of the weight bearing ratio were shown with COP total length and velocity(r=-.34), Y-axis velocity(r=-.39), FRT(r=.42), BBS(r=.54), TUG (r=-.39), and 10m walking test (r=-.42). CONCLUSION: This study result showed that as patients with stroke had more weight bearing ratio at the affected side, not only their static and dynamic balance abilities increased more but also functional gait ability improved more. These results mean that, to improve stroke patients' static, dynamic balance ability and gait ability, weight bearing training with the affected side foot placed one step forward necessary for gaits are important.

Comparative Study on Relationship between Vibration Level and Vibration Velocity (진동레벨과 진동속도의 상관성에 관한 비교연구)

  • Song, Ha-Lim;Noh, Young-Bae;Kang, Choo-Won
    • Explosives and Blasting
    • /
    • v.29 no.2
    • /
    • pp.43-50
    • /
    • 2011
  • This study measured a vibration level at each distance of construction fields where blasts occur using Lion measuring instrument and used BlastmateIII to measure vibration velocity at the same distance. A total 130 blasts occurred with the weight of a total of 5,180 kg and the number of blast holes per blast was 5, 10 and 20. The weight of 4 kg was used for each hole. Vibrations caused by blast was measured at the distance with the same velocity and level. Measurements were carried 15~102 m away from the blast source. and 273 data on vibration velocity and level were obtained from eight measurements. It analysed data on vibration velocity measured based on existing correlation formulas and compared them to real measurements to analyse interrelationship.

A Study on the Simultaneous Measurement of Droplet Size and Velocity in a Diesel Fuel Spray (디젤 분무(噴霧) 액적(液滴)의 크기와 속도(速度) 동시계측(同時計測)에 관한 연구(硏究))

  • Chang, Y.J.;Jeon, C.H.;Park, H.l.;Kim, H.K.;Kim, S.J.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.2 no.5
    • /
    • pp.11-22
    • /
    • 1994
  • The pupose of this study is to measure droplet size and velocity simultaneously for a transient diesel fuel spray in a quiescent chamber at atmospheric temperature and pressure. Generally, diesel combustion phenomena is mainly governed by characteristics of injection system and fuel spray. Therefore we need to clarify these characteristics for developing more economical diesel systems. In this study, correlation between droplet size and velocity was measured at downstream distance from nozzle. Governing parameters are pump speed and fuel quantity for the detailed nature in this transient diesel fuel spray. It is observed effect to the droplet size and velocity distribution. Velocity(peak, mean, rms), number density and droplet size were investigated simulaneously using PDA in the spray. Various results are presented to illustrate the effects of operation factors and correlation between the droplet diameter and velocity.

  • PDF

Shear wave velocity of sands subject to large strain triaxial loading

  • Teachavorasinskun, Supot;Pongvithayapanu, Pulpong
    • Geomechanics and Engineering
    • /
    • v.11 no.5
    • /
    • pp.713-723
    • /
    • 2016
  • Shear wave velocities of three selected sandy soils subject to drained triaxial compression test were continuously measured using the bender elements. The shear wave velocity during isotropic compression, as widely recognized, increased as confining pressure increased and they were correlated well. However, during drained shearing, the mean effective stress could no further provide a suitable correlation. The shear wave velocity during this stage was almost constant with respect to the mean effective stress. The vertical stress was found to be more favorable at this stage (since confining stress was kept constant). When sample was attained its peak stress, the shear wave velocity reduced and deviated from the previously existed trend line. This was probably caused by the non-uniformity induced by the formation of shear band. Subsequently, void ratios computed based on external measurements could not provide reasonable fitting to the initial stage of post-peak shear wave velocity. At very large strain levels after shear band formation, the digital images revealed that sample may internally re-arrange itself to be in a more uniform loose stage. This final stage void ratio estimated based on the proposed correlation derived during pre-peak state was close to the value of the maximum void ratio.

Uncertainty Analysis of Cross-Correlation Algorithm based on FFT by PIV Standard Images (표준 영상에 의한 FFT 기반 상호상관 PIV 알고리즘의 불확도 해석)

  • Lee, Suk-Jong;Choi, Jung-Geun;Sung, Jae-Young;Hwang, Tae-Gyu;Doh, Deog-Hee
    • Journal of the Korean Society of Visualization
    • /
    • v.3 no.2
    • /
    • pp.71-78
    • /
    • 2005
  • Uncertainty introduced by a cross-correlation algorithm based on FFT has been investigated using PIV standard images. The standard images were generated by the Monte Carlo simulation method. Both bias and random errors from the velocity vector have been analyzed with regard to the particle diameter, displacement, and the number of particles. The uncertainty of velocity is evaluated based upon the IS0/IEC standard. As a result, a total error of $0.26\%$ is included in the PIV cross-correlation algorithm. In addition, the uncertainty budget is presented, where the effect of the above three variables is examined. According to the budget, the variation of the number of particles within the interrogation window mainly contributes to the combined standard uncertainty of the real measured velocity field when excluding the effect of errors by the experiments itself. Finally, the expanded uncertainty is found to be about $12\%$ at the $95\%$ confidence level.

  • PDF