• Title/Summary/Keyword: Velocity Correlation

Search Result 1,145, Processing Time 0.031 seconds

Stable Channel Design for Physical Disturbance Reduction and Analysis of Habitat Suitability (물리적 교란 저감을 위한 안정하도의 설계와 서식적합도 분석)

  • Lee, Woong Hee;Moon, Hyong Geun;Choi, Heung Sik
    • Ecology and Resilient Infrastructure
    • /
    • v.4 no.3
    • /
    • pp.169-179
    • /
    • 2017
  • This study analyzed the aspect of bed change according to the stable channel design on the Wonju River to quantitatively evaluate habitat suitability (HS). According to the result of evaluating stable channel of object section in the Wonju River, 17 sections among total 20 sections were stable and 3 sections were unstable. Physical disturbance improvement evaluation (PDIE) was the range average showed good disturbance condition with a range average of 112.17 points. Habitat suitability index of Zacco Koreanus, the most dominant species of the Wonju River, was used for analysis of physical habitat for fish. According to the physical habitat analysis result, HS was 0.16 and weighted usable area (WUA) was $347.68m^2$. The methods of improving/introducing/removing structures and dredging stream channel were used for stable channel design of unstable channel, and analyzed PDIE according to the aspect of bed change and changes in habitat suitability. Stable channel design was possible in 19 sections in times of structures improvement/introduction/removal, and PDIE was 117.53 points, HS was 0.14 points, and WUA was $313.37m^2$. Stable channel design was possible in all 20 sections when dredging the stream channel. PDIE was 116.50 points, HS was 0.16, and WUA was $332.14m^2$. Therefore, this study obtained channel design measures that can improve physical soundness and stability of the Wonju River, and it was analyzed that it will have no impact on changes of physical disturbance and physical habitat. Furthermore, this study analyzed velocity and depth of each section and appearance frequency of riffle and pool to analyze correlation between physical disturbance and physical habitat. According to the analysis result, it was identified that the analysis of riffle and pool showed similar result as the evaluation result of physical habitat.

Phenotype-genotype correlations and the efficacy of growth hormone treatment in Korean children with Prader-Willi syndrome (프래더 윌리 증후군의 유전학적 발병 기전에 따른 표현형 및 성장 호르몬 치료 효과에 관한 연구)

  • Bae, Keun Wook;Ko, Jung Min;Yoo, Han Wook
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.3
    • /
    • pp.315-322
    • /
    • 2008
  • Purpose : Prader-Willi syndrome (PWS) is a complex genetic disorder, caused by the deletion of the paternally derived 15q11-13 region or the maternal uniparental disomy of chromosome 15 (mUPD(15)). In this study, we compared phenotypic differences between those patients whose disease was caused by microdeletion and those caused by mUPD(15). In addition, a comparison of the efficacy of growth hormone (GH) therapy between these two PWS genotypes was analyzed. Methods : Fifty-three patients were diagnosed as having PWS based on molecular and cytogenetic analyses and clinical features. Data that included maternal age, birth weight, a feeding problem in the neonatal period, cryptorchidism, developmental delay or mental retardation, short stature, hypopigmentation, changes in height, weight, and body mass indexes (BMI) before and after GH treatment were obtained by a retrospective review of medical records. The data from the patients with microdeletion were compared with those from the patients with mUPD(15). Results : Of the 53 patients with genetically confirmed PWS, 39 cases had microdeletion and 14 mUPD(15). Maternal ages were significantly higher in the mUPD(15) group, and hypopigmentation and a feeding problem in the neonatal period were more frequent in the microdeletion group. Growth hormone was administered to 20 patients [14 with microdeletion, 6 with mUPD(15)]. There were no differences between the two groups in height velocity, weight and height SDS, and BMI after GH therapy. Conclusion : Phenotype and genotype correlations were observed in Korean PWS patients, such as more advanced maternal ages in the mUPD(15) group and more feeding problems and hypopigmentations in the microdeletion group. Further long-term prospective studies are needed to correlate other aspects of the phenotypes.

Respiratory air flow transducer calibration technique for forced vital capacity test (노력성 폐활량검사시 호흡기류센서의 보정기법)

  • Cha, Eun-Jong;Lee, In-Kwang;Jang, Jong-Chan;Kim, Seong-Sik;Lee, Su-Ok;Jung, Jae-Kwan;Park, Kyung-Soon;Kim, Kyung-Ah
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.5
    • /
    • pp.1082-1090
    • /
    • 2009
  • Peak expiratory flow rate(PEF) is a very important diagnostic parameter obtained from the forced vital capacity(FVC) test. The expiratory flow rate increases during the short initial time period and may cause measurement error in PEF particularly due to non-ideal dynamic characteristic of the transducer. The present study evaluated the initial rise slope($S_r$) on the flow rate signal to compensate the transducer output data. The 26 standard signals recommended by the American Thoracic Society(ATS) were generated and flown through the velocity-type respiratory air flow transducer with simultaneously acquiring the transducer output signal. Most PEF and the corresponding output($N_{PEF}$) were well fitted into a quadratic equation with a high enough correlation coefficient of 0.9997. But only two(ATS#2 and 26) signals resulted significant deviation of $N_{PEF}$ with relative errors>10%. The relationship between the relative error in $N_{PEF}$ and $S_r$ was found to be linear, based on which $N_{PEF}$ data were compensated. As a result, the 99% confidence interval of PEF error was turned out to be approximately 2.5%, which was less than a quarter of the upper limit of 10% recommended by ATS. Therefore, the present compensation technique was proved to be very accurate, complying the international standards of ATS, which would be useful to calibrate respiratory air flow transducers.

Analysis of Fluidization in a Fluidized Bed External Heat Exchanger using Barracuda Simulation (바라쿠다 시뮬레이션을 이용한 유동층 외부 열교환기의 유동해석)

  • Lee, Jongmin;Kim, Dongwon;Park, Kyoungil;Lee, Gyuhwa
    • Korean Chemical Engineering Research
    • /
    • v.58 no.4
    • /
    • pp.642-650
    • /
    • 2020
  • In general, the circulation path of the fluidized particles in a CFB (Circulating Fluidized Bed) boiler is such that the particles entrained from a combustor are collected by a cyclone and recirculated to the combustor via a sealpot which is one of non-mechanical valves. However, when a fluidized bed heat exchanger (FBHE) is installed to additionally absorb heat from the fluidized particles, some particles in the sealpot pass through the FBHE and then flow into the combustor. At this time, in the FBHE operated in the bubbling fluidization regime, if the heat flow is not evenly distributed by poor mixing of the hot particles (800~950 ℃) flowing in from the sealpot, the heat exchanger tubes would be locally heated and then damaged, and the agglomeration of particles could also occur by formation of hot spot. This may affect the stable operation of the circulating fluidized bed. In this study, the unevenness of heat flow arising from structural problems of the FBHE of the domestic D-CFB boiler was found through the operating data analysis and the CPFD (Computational Particle Fluid Dynamics) simulation using Barracuda VR. Actually, the temperature of the heat exchanger tubes in the FBHE showed the closest correlation with the change in particle temperature of the sealpot. It was also found that the non-uniformity of the heat flow was caused by channeling of hot particles flowing in from the sealpot. However, it was difficult to eliminate the non-uniformity even though the fluidizing velocity of the FBHE was increased enough to fluidize hot particles vigorously. When the premixing zone for hot particles flowing in from the sealpot is installed and when the structure is changed through the symmetrization of the FBHE discharge line for particles reflowing into the combustor, the particle mixing and the uniformity of heat flow were found to be increased considerably. Therefore, it could be suggested that the structural modification of the FBHE, related to premixing and symmetric flow of hot particles, is an alternative to reduce the non-uniformity of the heat flow and to minimize the poor particle mixing.

The Synthetic Study of Environmental Contamination at the Seokdae Municipal Waste Landfill in Pusan (부산 석대 생활폐기물 매립장의 환경오염에 대한 종합적 연구)

  • 김병우;정상용;이민희;이병헌
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.04a
    • /
    • pp.98-103
    • /
    • 2001
  • In order to understand the characteristics of leachate at the Seokdae municipal waste landfill in the Pusan city, the correlation between leachate pollution loading and volume of gas production. concentration of gas and subsidence of ground, the characteristical methos, geochemical analyses and laboratory column tests using samples of gases, leachate and surface soil of Seokdae waste landfill area. Through the analysis of water balance, leachate flow rate and pollution loading were estimated. Geistatistical analysis of four gas components ( $O_2$, C $H_4$, $H_2$S and CO) shows the possibility of ground subsidence around the group of a site with high concentration of gas. From geochemical analyses of leachate, EC and Total-Alkalinity of ground subsidence around the group of a site with high concentration of gas. From geochemical analysis of leachate, Ec and Total-Alkalinity were increased, and Cl, Cr, Mn, Cu, Zn, Cd and Pb were decreassed comparing to the part, and the type of water quality was Na-HC $O_3$ in trilinear diagram. It shows that biodecomposition of municipal wastes continues actively. From the analysis of water balance, the total leachate flow rate is about 465.11㎥/day and pure pollution loading of Cl, Mn and Fe are estimated to 223.8kg/day, 0.2kg/day, 0.3kg/day, respectively. The laboratory column test of residual soil and landfill soil shows 0.206cm and 0.019cm for linear velocity(equation omitted), 0.234 $\textrm{cm}^2$/min and 0.018$\textrm{cm}^2$/min for diffusion coefficient ( $D_{ι}$), and 1.136cm and 0.095cm longitudinal dispersion index ($\alpha$$_{ι}$), respective]y. It demonstrates that the delay time of contamination for residual soil is shorter than that of landfill soil.

  • PDF

Simultaneous Multiple Transmit Focusing Method with Orthogonal Chirp Signal for Ultrasound Imaging System (초음파 영상 장치에서 직교 쳐프 신호를 이용한 동시 다중 송신집속 기법)

  • 정영관;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.1
    • /
    • pp.49-60
    • /
    • 2002
  • Receive dynamic focusing with an array transducer can provide near optimum resolution only in the vicinity of transmit focal depth. A customary method to increase the depth of field is to combine several beams with different focal depths, with an accompanying decrease in the frame rate. In this Paper. we Present a simultaneous multiple transmit focusing method in which chirp signals focused at different depths are transmitted at the same time. These chirp signals are mutually orthogonal in a sense that the autocorrelation function of each signal has a narrow mainlobe width and low sidelobe levels. and the crossorelation function of any Pair of the signals has values smaller than the sidelobe levels of each autocorrelation function. This means that each chirp signal can be separated from the combined received signals and compressed into a short pulse. which is then individually focused on a separate receive beamformer. Next. the individually focused beams are combined to form a frame of image. Theoretically, any two chirp signals defined over two nonoverlapped frequency bands are mutually orthogonal In the present work. however, a tractional overlap of adjacent frequency bands is permitted to design more chirp signals within a given transducer bandwidth. The elevation of the rosscorrelation values due to the frequency overlap could be reduced by alternating the direction of frequency sweep of the adjacent chirp signals We also observe that the Proposed method provides better images when the low frequency chirp is focused at a near Point and the high frequency chirp at a far point along the depth. better lateral resolution is obtained at the far field with reasonable SNR due to the SNR gain in Pulse compression Imaging .

An Association of Changed Levels of Inflammatory Markers with Hematological Factors during One-time Aerobic Exercise in Twenty-aged Young Men (20대 젊은이들에 있어 1회성 유산소운동 시 염증 표지자와 혈액변인들 간의 상관관계)

  • Hyun, Kyung-Yae
    • Journal of Life Science
    • /
    • v.19 no.11
    • /
    • pp.1658-1665
    • /
    • 2009
  • This study was carried out on thirty men to define the association of inflammatory markers with physiological factors on one-time aerobic exercise (for 15 min. Post-exercise interleukin-6 (IL-6), mean corpuscular hemoglobin concentration (MCHC), heart rate (HR), systolic blood pressure (SBP), and pulsatility and resistance index of middle cerebral artery (PI and RI, respectively) levels were elevated compared to those measured pre-exercise. Total leukocyte and platelet counts, high-sensitivity C-reactive protein (hs-CRP), free radical (FR), and low density lipoprotein cholesterol (LDL) levels tended to decrease after exercise. Pre-exercise IL-6 levels were positively correlated with pre-exercise SBP levels, while post-exercise IL-6 level was positively correlated with post-exercise PI and RI levels. Post-exercise, hs-CRP levels were negatively related to SBP and HR. Pre-exercise, FR levels were positively associated to SBP, DBP, and HR. Post-exercise FR levels were negatively related to the post-exercise blood flow velocity in middle cerebral artery. Pre-exercise erythrocyte indices (RBC, MCV, MCH, and MCHC levels) were in inverse proportion to pre-exercise IL-6 levels. Post-exercise FR levels were inversely related to post-exercise total leukocyte, lymphocyte, monocyte, and MCH levels. Pre-exercise $Mg^{++}$ levels were in inverse proportion to pre-exercise IL-6, hs-CRP, or FR levels. These findings suggest that one-time aerobic exercise offers a significant relationship between inflammatory markers and some biochemical markers or electrolytes. Further studies need to be carried out for investigation of differences between genders or age groups following one-time or regular aerobic exercise.

A Study on the Bed Climate and the Physiological Responses in Sleep. - On Ondol Environment - (수면시 침상기후와 인체생리반응에 관한 연구 -온돌환경을 중심으로-)

  • Kim Myung Ju;Choi Jeong Wha
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.15 no.2 s.38
    • /
    • pp.77-87
    • /
    • 1991
  • The purpose of this study were to investigate the bed climate and the physiological responses in sleep on the traditional Korean floor heating system called Ondol. Ondol has been the most widely used heating system in Korea, yet there has been a no systematic studies examined its environmental effects on human body. Experimental room was constructed to match the typical thermal environment of Ondol. (floor surface temperature; $32\~33^{\circ}C$, air temperature; $22.5{\pm}1.0^{\circ}C$, relative humidity; $64.0{\pm}4.0\%$RH, air velocity; 0.25 m/sec.) Three different combinations of bedclothes were chosen for the experiment based on the study results showing that they were the most widely used types in Korea. Type 1 was the combination of a cotton-padded mattress with a cotton-padded Korean style blanket. Type 2 was a cotton-padded mattress with a cotton-guilted Korean style blanket. Type 3 was a cotton-padded matless with a polyacryl blanket. Thermal resistance of each of these combina-tions in the bedclothes was measured using thermal manikin. Two adult female was chosen for the seven hour sleeping experiment which was known to be the average sleeping hours of Korean adult female. The bed climate was measured with the temperature under the mattress, the surface temper-ature of the mattress, and the air temperature and the relative humidity of the space between the mattress and blanket. The skin temperature, rectal temperature of the subjects and the bed climate were measured eight times, one hour before the experiment and every hour during the experiment. The weight loss and the subjective sensation were measured for the each subjects before and after the experiment. The procedure was repeated twice with two subjects and three types of bedclothes, yielding twelve combinations of results. The results were as follows; 1. With the surface temperature of $32\~33^{\circ}C$ of Ondol, air temperature was $22.5{\pm}1.0^{\circ}C$ with $64.0{\pm}4.0\%$ RH. The bed climates were $39.2{\pm}40.8^{\circ}C$ under the mattress, $35.3\~36.2^{\circ}C$ on the mattress, and $26.9\~32.0^{\circ}C$ with $56.0\~71.3\%$ RH between the mattress and the blanket. 2. Mean skim temperature during sleep was 34.2"C with local skin temperature of $34.0\~35.5^{\circ}C$. The skin temperatures of abdomen, thigh, foot were higher than the other parts of the body. 3. The skin temperature of chest, thigh, leg and back varied significantly according to the combinations of bedclothes. With the cotton-padded blanket, the skin temperature was the highest, while with the cotton-guilted blanket showed lowest. 4. Examining the relationship between the mean skin temperature and the local skin temper-ature, the chest temperature showed the highest correlation with the former. Therefore, the chest temperature can be recommended to represent the skin temperature in measuring the bed climate. 5. The subjective bed climates were $39.0\~40.4^{\circ}C$ under the mattress, $35.2\~35.9^{\circ}C$ on the mattress, $29.8\~31.6^{\circ}C$ with $56.8\~68.4\%$ RH between the mattress and blanket. In sum, from this experiment we not only obtained the reliable value of bed climates on Ondol, but also showed that the bed climates and the physiological responses were affected differently according to the materials of bed clothes.

  • PDF

A Study on Seasonal Variation of Water Content under Highway Asphalt Pavements Using Neutron Moisture Meter (중성자 수분측정기를 이용한 고속도로 포장의 계절별 함수량 변화 측정에 관한 연구)

  • Song Kwan-Cheol;Lee Sang-Mo;Yoo Sun-Ho;Ryu Kwan-Sik;Park Moo-Eon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.2 no.4
    • /
    • pp.156-166
    • /
    • 2000
  • This study was carried out to provide the information on seasonal variations of water content under highway asphalt pavements which influence on the dynamic behaviour and durability of pavements, and to assess the correlation between water content and soil or meteorological factors. Total eight sites for water content measurement which included fives sites in Kyungbu, two sites in Honam, and one site in Youngdong Highway were selected considering the variations in geology, topology and meteorology factors over all the country. Water contents under asphalt pavements were measured up to 170 cm depth every two week for total 13 months of August 1992 through September 1993 using neutron moisture meter(CPN-503DR). The range of water content ($\theta$$_{w}$) at the upper soils of above 50 cm depth was 7~12% and was not quite different regardless of sites, except for Iseo site. However, soil water contents below 60 or 70 cm depth were significantly different between the measurement sites, that is, the lowest water content was 5% at Kyungsan site and the highest water content was 20% at Iseo site. For all the sites, seasonal variations in water content during the experimental period were little, their range was within only 1 to 4%. Seasonal variations of water content in original or cutting area, which were 4% more or less, were slightly larger than in bedding areas, which were below 2%. Water contents under asphalt pavements had statistically significant positive correlations with silt and clay content in soil, but there were little correlations between water content and meteorological factors such as precipitation, relative humidity, mean air temperature, and wind velocity.

  • PDF

Association between MIR149 SNPs and Intrafamilial Phenotypic Variations of Charcot-Marie-Tooth Disease Type 1A (샤르코-마리-투스병 1A형(CMT1A)의 가족내 표현형적 이질성과 MIR149 SNP에 대한 연관성 연구)

  • Choi, Yu Jin;Lee, Ah Jin;Nam, Soo Hyun;Choi, Byung-Ok;Chung, Ki Wha
    • Journal of Life Science
    • /
    • v.29 no.7
    • /
    • pp.800-808
    • /
    • 2019
  • Charcot-Marie-Tooth disease (CMT) is a group of rare peripheral neuropathies characterized by progressive muscle weakness and atrophy and areflexia in the upper and lower extremities. The most common subtype of CMT is CMT1A, which is caused by a tandem duplication of the PMP22 gene in the 17p12 region. Patients with CMT1A show a loose genotype-phenotype correlation, which suggests the existence of secondary genetic or association factors. Recently, polymorphisms of rs71428439 (n.83A>G) and rs2292832 (n.86T>C) in the MIR149 have been reported to be associated with late onset and mild phenotypic CMT1A severity. The aim of this study was to examine the intrafamilial heterogeneities of clinical phenotypes according to the genotypes of these two SNPs in MIR149. For this study, we selected 6 large CMT1A families who showed a wide range of phenotypic variation. This study suggested that both SNPs were related to the onset age and severity in the dominant model. In particular, the AG+GG (n.83A>G) and TC+CC genotypes (n.86T>C) were associated to late onset and mild symptoms. Motor nerve conduction velocity (MNCV) was not related to the MIR149 genotypes. These results were consistent with the previous studies. Therefore, we suggest that the rs71428439 and rs2292832 variants in MIR149 may serve as genetic modifiers of CMT1A intrafamilial phenotypic heterogeneity, as they have a role in the unrelated patients. This is the first study to show an association using large families with variable clinical CMT1A phenotypes. The results will be helpful in the molecular diagnosis and treatment of patients with CMT1A.