Vessel Remodeling after Intima-to-Intima Contact Anastomosis

  • Yeo, Hyeonjung;Kim, Hyodong;Son, Daegu;Hong, Changbae;Kwon, Sun Young
    • Archives of Plastic Surgery
    • /
    • v.44 no.2
    • /
    • pp.95-100
    • /
    • 2017
  • Background Intima-to-intima microanastomotic vascular remodeling was explored, utilizing a polylactide-caprolactone absorbable vein coupler model (PAVCM), which was designed to simulate a non-absorbable counterpart system with the sole exception of being absorbable. Methods Six New Zealand white rabbits were used. After transection of the jugular vein, 2 PAVCMs were placed, 1 at each transected end. The stumps were slipped through the PAVCMs, and the venous wall was everted $90^{\circ}$ to achieve intima-to-intima contact. Reanastomosis of the transected jugular vein was performed bilaterally in 3 rabbits. In the other 3 rabbits, the jugular vein (20 mm) harvested from one side was interpositionally grafted to the jugular vein on the opposite side to ease the anastomotic tension. Patency testing, ultrasonography, and histologic assessments were conducted postoperatively at weeks 2, 4, 12, 16, 22, and 26. Results All anastomotic sites were patent, without stenosis, occlusion, or dilatation. In the histologic sections, immature endothelial regeneration was observed at week 2, which was completed by week 4. Regeneration of the tunica media was noted at week 12. Between week 22 and week 26, the tunica media fully regenerated and the coupler dissipated entirely. Conclusions Despite the absence of a coupler to act as an anastomotic buttress, the structure and function of all the vessels appeared normal, even histologically. These outcomes are true milestones in the development of an absorbable vein coupler.

MAC System for Microanastomosis of Free Flap (유리피판술에 있어서 자동혈관문합기의 적용)

  • Jung, Young-Jin;Kim, Hyun-Ji;Son, Dae-Gu
    • Archives of Reconstructive Microsurgery
    • /
    • v.15 no.2
    • /
    • pp.51-57
    • /
    • 2006
  • Free flap having been used for reconstruction of skin and soft tissue defect in various areas in a body is spreading up its application for not only functional reconstruction but also aesthetic reconstruction. Authors met with good results minimizing the demerits of anastomosis using suture through microvascular anastomotic device, hereupon, we intend to report this. We worked with 27 cases that used microvascular anastomotic device for venous anastomoses among patients who were processed free flap in our hospital. Age ranged from 12 to 63 (average 43.2), and there were 12 females and 15 males. As a result of a follow-up by 3 months - 5years (average 11.3 months), there was no particular complication in the anastomosed vein except 1 cases among 27 cases that sutured their veins through microvascular anastomotic device. Use of microvascular anastomotic device at free flap shortened the time required for vascular anastomoses to reduce ischemic time of tissue, and minimized the damage of intima during anastomoses and made easy anastomoses possible even in case the difference of diameters of blood vessels being sutured is wide. As well, even for survival rate of flap, satisfactory results were obtained compared with using suture. Consequently, it is concluded that use of microvascular anastomotic device in free flap is a useful way that can substitute existing anastomosis using suture.

  • PDF