• Title/Summary/Keyword: Vehicle grounding

Search Result 12, Processing Time 0.024 seconds

A CONCEPTUAL DESIGN FOR ELECTRICAL GROUNDING ARCHITECTURE OF KOREAN SPACE LAUNCH VEHICLE

  • Kim Kwang-Soo;Lee Soo-Jin;Ma Keun-Soo;Shin Myoung-Ho;Hwang Seung-Hyun;Ji Ki-Man;Chung Eui-Seung
    • Bulletin of the Korean Space Science Society
    • /
    • 2004.10b
    • /
    • pp.231-234
    • /
    • 2004
  • Electrical grounding is defined as referencing an electrical circuit or a common reference plane for preventing shock hazards and for enhancing operability of the circuit and EMI control. In order to realize the best electrical grounding system of korean space launch vehicle, we should design the electrical grounding architecture of korean space launch vehicle of system-level at the earliest point in design procedure. To minimize the electrical grounding loop and the unnecessary electromagnetic interference or radiation among the electronic subsystems, we should establish the electrical grounding rules of the all electrical interfaces. The electrical interfaces among the electronic subsystems are generally classified into the electrical power and signal interfaces. Because of using the primary and secondary power system architecture in the korean space launch vehicle system such as the common space launch vehicle systems, we need to establish the electrical grounding rules between the primary and secondary power system. We also need to establish the electrical signal grounding interface rules among the electronic subsystems. In this paper, we will describe the grounding schemes of the common space launch vehicle system and propose a conceptual design for the electrical grounding architecture of korean space launch vehicle system.

  • PDF

A Study on the Portable and Vehicle-Mounted Generators Grounding of Low-Voltage Systems (간이 저압 전력계통에서의 계통 접지대책에 관한 연구)

  • Wee, Won-Seok;Kim, Jung-Hoon;Cho, Gyu-Deak;Ryu, Bo-Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.43-45
    • /
    • 2000
  • In this paper, portable and vehicle-mounted generators grounding methods of low-voltage systems is compared to each other. Ungrouded system is better for the safety operation than solidly grounding system. This paper also determined the magnitude and duration of the permissible body current limit and step voltage for the solidly-grounding and ungrounded system.

  • PDF

Fault Analysis for Electric Railway System (전기철도 시스템의 사고 해석)

  • Lee, Han-Min;Jang, Dong-Uk;Kim, Gil-Dong
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.291-295
    • /
    • 2005
  • This paper presents the modeling of grounding system on Korean electric railway system. The system model is composed of the catenary system, the grounding-system, the sub-sectioning post, the fault point, the sectioning post, the autotransformer in the substation, and the electric vehicle. The increment of rail-ground voltage may be thought as an amplifier of danger on human body of equipment insulation. The rail-ground voltage on steady state and on fault condition should be under standard limit voltage. To analyze grounding system for steady state and fault condition on Korean railway, modeling for each railway system is performed by 10-port network model. Modeling and analysis of present grounding-system are important to protect human and electronic equipments. The examinations for systematic grounding-system are investigated.

  • PDF

Research on Standards for Protection against Electric Shock in Global Technical Regulations of Fuel Cell Vehicle (연료전지 자동차 세계기술규정의 감전보호기준 연구)

  • HwangBo, Cheon;Lee, Kyu-Myong;You, Kyeong-Jun
    • Journal of Hydrogen and New Energy
    • /
    • v.21 no.3
    • /
    • pp.167-183
    • /
    • 2010
  • This paper analyzes the backgrounds of the standards for protection against electric shock in Global Technical Regulations (GTR) of Fuel Cell Vehicle (FCV). Targets on research were high voltage criteria, safety current, isolation and grounding resistance, time limitation, energy, adequate clearance, and test procedure. Based on human impedance and effect of current in IEC 60479-1, safety of human was examined. Then, isolation and grounding circuit model of FCV were analyzed theoretically. The results give several suggestions: touch voltage less than 25V, AC energy less than 0.0813J, separation considering middle finger length, grounding resistance less than $0.2\Omega$, maximum AC ground voltage of 1V (rms), and isolation resistance between earth and electrical chassis. In MATLAB/Simulink environment, error characteristics of isolation resistance measurement procedure using internal DC sources were analyzed under variations of internal resistance of voltmeter and isolation resistance.

Analysis on the Method of Forward-Reverse Fault localization of Electric Railways for the Improvement of Accuracy (전기철도 정역방향 고장점표정 방법을 통한 정확도 향상을 위한 연구)

  • Kim, Myeong Su;Kim, Seong Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.12
    • /
    • pp.1735-1742
    • /
    • 2018
  • The number of electric railway failures will increase due to the external and internal effects of electric railroads. The grounding test with 25,000V is to artificially test the transmission voltage to ground, and it is possible to cause risks of electric shock and other equipment insulation damage in neighboring enclosure. In 2016, method of fault localization changed to low - voltage at 380V from artificially high- voltage in the grounding tests since opening of Seoul Metropolitan Express Railway; The method is more accurate and safer rather than the previous one because it gets more data from unlimited grounding tests. However, an electric current falls on the track section where the track branches and vehicle bases with many lines. To precisely detect a transitive phenomenon, it is necessary to continuously study and additionally install.

Resistive Grounding Technique of Heat Sink for Reducing Radiation Noise

  • Ahn, Chang-Hoi;Oh, JaeHyun
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1724-1728
    • /
    • 2014
  • Heat sink has been used to help an electrical device operate in normal temperature condition. But heat sink radiates unwanted electromagnetic wave, which may cause electromagnetic interference problem. A resistance loaded grounding technique is proposed to reduce electromagnetic wave radiation by a heat sink. Numerical simulations are accomplished to find optimal loading resistance. Also electromagnetic fields radiated by from a heat sink are measured and compared with the simulation results. The test results verify the usefulness of the proposed technique.

One-wire In-Vehicle Controller Design and Manufacturing by DC-PLC Scheme

  • Lee, Geum-Boon;Kim, Nam-Gon;Lee, Ji-Min
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.3
    • /
    • pp.9-15
    • /
    • 2016
  • In this paper, DC-PLC typed one-wire controller was designed and manufactured especially for In-vehicle safe devices. One-wire by DC-PLC scheme is to be used as a power supply and ground to process the sensor data and to operate the vehicle actuators. To avoid complicate wires, we use the conventional wires without installing extra communication lines. The data collected from the sensors are transmitted to the main controller, processed by programming, and run the actuators corresponding to the commands sending to vehicle control board. The proposed method shows that only One-wire without requiring several wires make In-vehicle control devices simple and reduce the damage due to the loss of the wiring.

Effect Analysis for Inequality of Basic Grounding in Bimodal Tram (바이모달 트램의 기준접지 불균등전위에 따른 영향분석)

  • Lee, Kang-Won;Mok, Jai-Kyun;Jang, Se-Ky
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.78-81
    • /
    • 2011
  • Generally, vehicle is insulated from the earth by rubber tire which is intrinsically the insulation material. The electrical ground of vehicle was floated in the sense of electric potential over the electric power sources. First of all, the floated electrical ground of vehicle should be equipotentially connected with the (-) line of electrical equipment. Bimodal tram has the different kinds of electric system. They must be kept insulated to each other electrically. When there is some unbalanced event or connection between them, it will invoke some errors or breakdown to electrical devices including sensors and actuators. This paper has investigated the floating ground effect of bimodal tram built with composite body and shown the effect according to the unbalanced ground of vehicle and the connection between different electric systems.

  • PDF

Harmonic Analysis for Traction Power Supply System with Common Grounding (공동접지방식 급전시스템의 고조파 해석)

  • 오광해;이한민;장동욱;김주락
    • Proceedings of the KSR Conference
    • /
    • 2000.11a
    • /
    • pp.688-695
    • /
    • 2000
  • This study presents an approach to model and to analyse traction power feeding system focused on the amplification of harmonic current. Through the research we can conclude the following: - The resonance frequency is not depend on the location of vehicle. The magnification of harmonic is, however, a function of the position of a train. - The resonance frequency is lower as catenary length is longer.

  • PDF

One-Wire In-Vehicle Controller Design by DC-PLC Scheme (DC-PLC 방식의 차량용 One-Wire 컨트롤러 설계)

  • Lee, Geum-Boon;Kim, Nam-Gon;Lee, Ji-Min
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2016.01a
    • /
    • pp.13-14
    • /
    • 2016
  • 본 논문은 차량 컨트롤러 메인보드 개발에 있어 DC-PLC 방식으로 One-wire만으로 전원 공급 및 접지로 사용하도록 하여 센서 데이터 처리 및 구동 장치를 작동시키는 방법을 제안한다. 복잡한 배선을 피하기 위해 별도의 통신선을 설치하지 않고 기존 배선(wire)를 이용하며, 센서로부터 수집된 데이터를 처리하여 구동 장치를 작동시키는 명령을 전달하도록 설계한다. 본 논문은 제어장치에 들어가는 배선을 간단히 하고 차량 내부 상태를 점검하고 제어하는 기술을 설계하고 구현코자 한다.

  • PDF