• 제목/요약/키워드: Various head positions

Search Result 28, Processing Time 0.024 seconds

Image Perception of Wedding Hair Coordination (I) -Based on female University Students- (웨딩헤어 관련 코디네이션의 이미지 지각 (I) -여대생을 중심으로-)

  • 정현주;한유정
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.27 no.7
    • /
    • pp.735-745
    • /
    • 2003
  • This paper looks at perceived images of female university students concerned with various wedding hair coordination including wedding hair styles, veil details and fitting positions and head dresses. Ta design an experimental test of a wedding dress and hair coordination variables, the content analysis of magazines was performed and hair experts were interviewed. 17 stimuli representing the variables of wedding hair coordination were manipulated and included with hair styles(2), veil details(2), veil fitting Positions(2), head dresses(2) and a wedding hat(1). The questionnaire of 445 was carried out and data were statistically processed. As a result, five images of wedding hair coordination were factors loaded, that is, favorable, decorative, smooth, personal and pretty one. Various main and interaction effects were found in images of it regarding to changing hair styles, different veil details and fitting positions and head dresses. favorable images, they affected by interactions between hair styles and veil details, hair styles and veil fitting positions, hair styles and head dresses and between veil details and the fitting positions. For personal images, interactions between veil details and the positions of veil fitting had effects on female students; for smooth images, That is, for hair style, female university students were influenced by favorable and smooth images; for veil details, by decorative and smooth images; for the positions of fitting veil, by decorative and favorable ones Then the researcher examined effects by dual interactions between factors of wedding hair coordination. For decorative images, they were found influenced by interactions between hair styles and veil details and between hair styles and head dresses. For personal ones, interactions between veil details and the fitting positions; for pretty images, interactions between the fitting positions and head dresses. These findings will provide sellers of the wedding dress with the idea of how females to perceive wedding hair coordination according to the variation of it.

Evaluation of linear measurements of implant sites based on head orientation during acquisition: An ex vivo study using cone-beam computed tomography

  • Sabban, Hanadi;Mahdian, Mina;Dhingra, Ajay;Lurie, Alan G.;Tadinada, Aditya
    • Imaging Science in Dentistry
    • /
    • v.45 no.2
    • /
    • pp.73-80
    • /
    • 2015
  • Purpose: This study evaluated the effect of various head orientations during cone-beam computed tomography (CBCT) image acquisition on linear measurements of potential implant sites. Materials and Methods: Six dry human skulls with a total of 28 implant sites were evaluated for seven different head orientations. The scans were acquired using a Hitachi CB-MercuRay CBCT machine. The scanned volumes were reconstructed. Horizontal and vertical measurements were made and were compared to measurements made after simulating the head position to corrected head angulations. Data was analyzed using a two-way ANOVA test. Results: Statistical analysis revealed a significant interaction between the mean errors in vertical measurements with a marked difference observed at the extension head position (P<0.05). Statistical analysis failed to yield any significant interaction between the mean errors in horizontal measurements at various head positions. Conclusion: Head orientation could significantly affect the vertical measurements in CBCT scans. The main head position influencing the measurements is extension.

Diagnosis and treatment of positional plagiocephaly

  • Jung, Bok Ki;Yun, In Sik
    • Archives of Craniofacial Surgery
    • /
    • v.21 no.2
    • /
    • pp.80-86
    • /
    • 2020
  • Positional plagiocephaly is increasing in infants. Positional plagiocephaly is an asymmetric deformation of skull due to various reasons; first birth, assisted labor, multiple pregnancy, prematurity, congenital muscular torticollis and position of head. Positional plagiocephaly can mostly be diagnosed clinically and by physical examinations. The simplest way to assess the severity of plagiocephaly is to use a diagonal caliper during physical examination, which measures the difference between the diagonal lengths on each side of the head. Plagiocephaly can be treated surgically or conservatively. Positional plagiocephaly, which is not accompanied by craniosynostosis, is treated conservatively. Conservative treatments involve a variety of treatments, such as change of positions, physiotherapy, massage therapy, and helmet therapy. Systematic approaches to clinical examination, diagnosis and treatment of positional plagiocephaly can be necessary and the age-appropriate treatment is recommended for patients with positional plagiocephaly.

Experimental Study to reveal Optimum Condition of CO2 Supply Membrane at Photobioreactor (광생물반응기의 CO2 공급 멤브레인의 최적 조건 도출을 위한 실험적 연구)

  • Kim, H.N.;Lee, J.H.;Choi, E.J.;Oh, Y.G.;Kim, Jeongbae
    • Journal of ILASS-Korea
    • /
    • v.19 no.3
    • /
    • pp.130-135
    • /
    • 2014
  • This study was performed to reveal the relationships between various gas supply conditions including inlet numbers and positions for Photobioreactor. To do that, this study was installed the experimental apparatus. All experiments were performed for the cases with 1, 2, 3, and 4 inlets and for gas flow rate of 4~8 lpm. Through the experiments, this study showed that the case with 3 or 4 inlets could reduce about 50% of the pressure loss head for all gas path than that of one inlet base case. So, these results can be used as basic data to design the gross or multiple photobioreactor.

Distortion of tooth axes on panoramic radiographs taken at various head positions (두부 위치 변화에 따른 파노라마 방사선사진상의 치축각도의 왜곡)

  • Jeon, Hyun-Sang;Choi, Gab-Lim;Lim, Sung-Hoon;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.38 no.4
    • /
    • pp.240-251
    • /
    • 2008
  • Objective: The purpose of this study was to evaluate the effect of head position changes on the root parallelism between adjacent teeth on panoramic radiographs. Methods: A model with normal occlusion was constructed in the SolidWorks program, then RP (rapid protyping) model was fabricated. The model was repeatedly imaged and repositioned five times at each of the following nine positions: ideal head position, $5^{\circ}$ up, $10^{\circ}$ up, $5^{\circ}$ down, $10^{\circ}$ down, $5^{\circ}$, right, $10^{\circ}$, up, and $5^{\circ}$ right rotation, $10^{\circ}$ right rotation. Panoramic radiographs were taken by Planmeca ProMax and the angle between the long axes of adjacent teeth was directly measured in the monitor. Results: Axes of adjacent teeth tended to converge toward the occlusal plane when the head tilted up and converged in the opposite direction to the occlusal plane when the head tilted down. Anterior teeth showed the most notable differences. When one side of the head tilted up $5^{\circ}$ and $10^{\circ}$ along the anteroposterior axis (Y axis), tooth axes of the same side tended to converge toward the occlusal plane and tooth axes of the opposite side tended to converge in the opposite direction to the occlusal plane. When the head rotated to one side along the vertical axis (Z axis), the canine and lateral incisor of the same side converged in the opposite direction to the occlusal plane and the canine and lateral incisor of the other side converged toward the occlusal plane. Conclusions: When assessing the root parallelism on panoramic radiographs, the occlusal plane cant (anteroposterior or lateral) or asymmetry of the dental arch should be considered because these can cause distortion of tooth axes on panoramic radiographs.

Spectral Distortion of Head-Related Transfer Function Due to Wearing Clothes and Glasses (옷가지와 안경 착용에 따른 머리전달함수의 스펙트럼 왜곡)

  • Jo, Hyun;Hwang, Sung-Mok;Lee, Yun-Jae;Park, Young-Jin;Park, Youn-Sik
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.103-107
    • /
    • 2009
  • Because individual HRTFs (Head-Related Transfer Functions) vary from a person to a person, a HRTF database has been measured by researchers to investigate the inter-subject variation, and to generate high fidelity virtual sound image. Individual HRTFs not only vary between subjects but also vary due to wearing clothes and glasses in daily life. However, influence of different dressing condition on the measured HRTF was not sufficiently investigated. To quantify the effect of wearing clothes and glasses, dummy's HRTF is measured in an anechoic chamber with various dressing condition, and is evaluated in the sense of spectral distortion. HRTFs are measured both in the median plane and in the horizontal plane. In the median plane, under 6kHz, effect of different wearing clothes and glasses is negligible. Over 6kHz, however, effect of clothing distorts HRTF about 6dB in the sense of spectral distortion. Moreover, at high frequencies, effect of glasses is no longer negligible. In the horizontal plane, at some azimuths, even additional light cloth over the dummy can change the spectrum of HRTF (6dB spectral distortion) especially when sound source is at contralateral positions. Therefore, HRTF measurement with different wearing conditions can broaden the capability of HRTF customization whose technique utilizes a HRTF database.

  • PDF

Is the SAM phantom conservative for SAR evaluation of all phone designs?

  • Lee, Ae-Kyoung;Hong, Seon-Eui;Choi, Hyung-Do
    • ETRI Journal
    • /
    • v.41 no.3
    • /
    • pp.337-347
    • /
    • 2019
  • The specific anthropomorphic mannequin (SAM) phantom was designed to provide a conservative estimation of the actual peak spatial specific absorption rate (SAR) of the electromagnetic field radiated from mobile phones. However, most researches on the SAM phantom have been based on early phone models. Therefore, we numerically analyze the SAM phantom to determine whether it is sufficiently conservative for various types of mobile phone models. The peak spatial 1- and 10-g averaged SAR values of the SAM phantom are numerically compared with those of four anatomical head models at different ages for 12 different mobile phone models (a total of 240 different configurations of mobile phones, head models, frequencies, positions, and sides of the head). The results demonstrate that the SAM phantom provides a conservative estimation of the SAR for only mobile phones with an antenna on top of the phone body and does not ensure such estimation for other types of phones, including those equipped with integrated antennas in the microphone position, which currently occupy the largest market share.

Development of a Biomechanical Motion System for the Rehabilitation of Various Joints (다 관절 재활운동을 위한 생체역학적 운동구현 시스템 개발)

  • Lee Y. S.;Baek C. S.;Jang J. H.;Sim H. J.;Han C. S.;Han J. S.
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.511-517
    • /
    • 2004
  • The existing rehabilitation systems were developed to exercise specific joints only. Therefore rehabilitating the various joints of human, various kinds of devices are need. To overcome these defects, this paper proposed the CMRS, an integrated system that performs various rehabilitation exercises. The characteristics of motion and the positions between human body and the system were investigated with the kinematics analysis of upper and lower limb of human body. We presented a proper mechanism to develop a rehabilitation device on the base of the study and studied the relative positions between head part and human joints. Through the simulations, the possibility of rehabilitation system was verified. And the base frame was also developed for convenient and stable position control. Finally, the CMRS was developed as an 8 degree of freedom mechanism. It is expected that the CMRS will be applied to the rehabilitations of various joints.

Reliability of implant stability measuring devices depending on various clinical conditions: an in vitro study

  • Han-Na Lee;Myoung-Sub Kim;Jeong-Yol Lee;Xu Zihan;Jae-Jun Ryu;Ji-Suk Shim
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.3
    • /
    • pp.126-135
    • /
    • 2023
  • PURPOSE. The aim of this study was to evaluate the reliability of implant stability measuring devices depending on the location of the implant and the position of the patient. MATERIALS AND METHODS. Six implants were installed in different dentate sextants of six artificial bone models. Implant stability was measured in three conditions of the bone model (without mounting on a phantom head, mounted on a phantom head in supine position, and mounted on a phantom head in upright position). A resonance frequency analysis device (Osstell) and two damping capacity analysis devices (Periotest and Anycheck) were used to measure implant stability. The values measured outside the phantom head were treated as controls, and the values inside the phantom head were compared using an independent t-test. RESULTS. Osstell showed different results in two of the six divisions in both the supine and upright positions compared to outside of the mouth (P < .05). Periotest showed different results in all six parts in the supine position and in five parts in the upright position compared to outside of the mouth (P < .05). While Anycheck showed different results in five areas in the supine position compared to outside of the mouth, it showed different results in only one area in the upright position (P < .05). CONCLUSION. In the difficult implant position for the operator to access, the implant stability measuring devices show less reliability. The accessibility of implant is greatly affected in the order of Osstell, Anycheck, and Periotest.

Discrepancies in Soft Tissue Profile of Patients for Orthognathic Surgery between Preoperative Lateral Facial Photograph, Lateral Cephalogram and Supine Position on Operation Table

  • Jung, Young-Eun;Yang, Hoon-Joo;Hwang, Soon-Jung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.3
    • /
    • pp.180-185
    • /
    • 2012
  • Purpose: An accurate preoperative analysis of the patient is essential in orthognathic surgery in order to acquire superior results. In profile, the location of the chin's position may change according to the neck's inclination. This may ultimately affect the amount of surgical movement. During acquisition of cephalometric radiographs, or in supine position, there is a discrepancy in the neck's inclination. This means that there are also various discrepancies between the actual profile and the various preoperative profile images. In the clinical situation, the decision in performing genioplasty usually lies in the analysis of the patient's profile on the operating table at the final stages of orthognathic surgery. This study aims to analyze the different preoperative profile images and to compare their discrepancies. Methods: Fifty eight patients undergoing orthognathic surgery were chosen. These patients were divided into three groups according to angle's classification of malocclusion, as class I, II or III. The right profile of these patients in centric occlusion was taken in natural head position (NHP). This was set as the 'actual profile image.' Another right profile image was taken on the operating table after insertion of the nasotracheal intubation and with muscle relaxants in effect. This was also taken in centric occlusion. The angle (denoted 'A') between the soft tissue glabella-pognion and the true vertical plane was found in the above-mentioned profile images and in the cephalometric radiographs. The differences of these values were analyzed. Results: There were differences in Angle 'A' in all of the preoperative images. These values were however, not statistically significant. Conclusion: In order to gain an esthetic profile during orthognathic surgery, the NHP is shown to be the most reliable position. Images reproducing such head positions should be used in the treatment planning process.