• 제목/요약/키워드: Various head positions

검색결과 28건 처리시간 0.027초

웨딩헤어 관련 코디네이션의 이미지 지각 (I) -여대생을 중심으로- (Image Perception of Wedding Hair Coordination (I) -Based on female University Students-)

  • 정현주;한유정
    • 한국의류학회지
    • /
    • 제27권7호
    • /
    • pp.735-745
    • /
    • 2003
  • This paper looks at perceived images of female university students concerned with various wedding hair coordination including wedding hair styles, veil details and fitting positions and head dresses. Ta design an experimental test of a wedding dress and hair coordination variables, the content analysis of magazines was performed and hair experts were interviewed. 17 stimuli representing the variables of wedding hair coordination were manipulated and included with hair styles(2), veil details(2), veil fitting Positions(2), head dresses(2) and a wedding hat(1). The questionnaire of 445 was carried out and data were statistically processed. As a result, five images of wedding hair coordination were factors loaded, that is, favorable, decorative, smooth, personal and pretty one. Various main and interaction effects were found in images of it regarding to changing hair styles, different veil details and fitting positions and head dresses. favorable images, they affected by interactions between hair styles and veil details, hair styles and veil fitting positions, hair styles and head dresses and between veil details and the fitting positions. For personal images, interactions between veil details and the positions of veil fitting had effects on female students; for smooth images, That is, for hair style, female university students were influenced by favorable and smooth images; for veil details, by decorative and smooth images; for the positions of fitting veil, by decorative and favorable ones Then the researcher examined effects by dual interactions between factors of wedding hair coordination. For decorative images, they were found influenced by interactions between hair styles and veil details and between hair styles and head dresses. For personal ones, interactions between veil details and the fitting positions; for pretty images, interactions between the fitting positions and head dresses. These findings will provide sellers of the wedding dress with the idea of how females to perceive wedding hair coordination according to the variation of it.

Evaluation of linear measurements of implant sites based on head orientation during acquisition: An ex vivo study using cone-beam computed tomography

  • Sabban, Hanadi;Mahdian, Mina;Dhingra, Ajay;Lurie, Alan G.;Tadinada, Aditya
    • Imaging Science in Dentistry
    • /
    • 제45권2호
    • /
    • pp.73-80
    • /
    • 2015
  • Purpose: This study evaluated the effect of various head orientations during cone-beam computed tomography (CBCT) image acquisition on linear measurements of potential implant sites. Materials and Methods: Six dry human skulls with a total of 28 implant sites were evaluated for seven different head orientations. The scans were acquired using a Hitachi CB-MercuRay CBCT machine. The scanned volumes were reconstructed. Horizontal and vertical measurements were made and were compared to measurements made after simulating the head position to corrected head angulations. Data was analyzed using a two-way ANOVA test. Results: Statistical analysis revealed a significant interaction between the mean errors in vertical measurements with a marked difference observed at the extension head position (P<0.05). Statistical analysis failed to yield any significant interaction between the mean errors in horizontal measurements at various head positions. Conclusion: Head orientation could significantly affect the vertical measurements in CBCT scans. The main head position influencing the measurements is extension.

Diagnosis and treatment of positional plagiocephaly

  • Jung, Bok Ki;Yun, In Sik
    • 대한두개안면성형외과학회지
    • /
    • 제21권2호
    • /
    • pp.80-86
    • /
    • 2020
  • Positional plagiocephaly is increasing in infants. Positional plagiocephaly is an asymmetric deformation of skull due to various reasons; first birth, assisted labor, multiple pregnancy, prematurity, congenital muscular torticollis and position of head. Positional plagiocephaly can mostly be diagnosed clinically and by physical examinations. The simplest way to assess the severity of plagiocephaly is to use a diagonal caliper during physical examination, which measures the difference between the diagonal lengths on each side of the head. Plagiocephaly can be treated surgically or conservatively. Positional plagiocephaly, which is not accompanied by craniosynostosis, is treated conservatively. Conservative treatments involve a variety of treatments, such as change of positions, physiotherapy, massage therapy, and helmet therapy. Systematic approaches to clinical examination, diagnosis and treatment of positional plagiocephaly can be necessary and the age-appropriate treatment is recommended for patients with positional plagiocephaly.

광생물반응기의 CO2 공급 멤브레인의 최적 조건 도출을 위한 실험적 연구 (Experimental Study to reveal Optimum Condition of CO2 Supply Membrane at Photobioreactor)

  • 김하늘;이재환;최은지;오유관;김정배
    • 한국분무공학회지
    • /
    • 제19권3호
    • /
    • pp.130-135
    • /
    • 2014
  • This study was performed to reveal the relationships between various gas supply conditions including inlet numbers and positions for Photobioreactor. To do that, this study was installed the experimental apparatus. All experiments were performed for the cases with 1, 2, 3, and 4 inlets and for gas flow rate of 4~8 lpm. Through the experiments, this study showed that the case with 3 or 4 inlets could reduce about 50% of the pressure loss head for all gas path than that of one inlet base case. So, these results can be used as basic data to design the gross or multiple photobioreactor.

두부 위치 변화에 따른 파노라마 방사선사진상의 치축각도의 왜곡 (Distortion of tooth axes on panoramic radiographs taken at various head positions)

  • 전현상;최갑림;임성훈;김광원
    • 대한치과교정학회지
    • /
    • 제38권4호
    • /
    • pp.240-251
    • /
    • 2008
  • 본 연구는 파노라마 방사선사진에서 두부 위치 변화에 따라 인접 치아장축 사이에 이루는 각도가 어떻게 변화되는지 알아보기 위해 시행하였다. 정상교합자의 모델을 기초로 하여 3차원 solid 모델을 구성하고 이를 신속 조형모델(rapid prototyping, RP)로 제작하였다. 다음 9가지 두부위치들을 5주 동안 일주일 간격으로 재위치시키고 촬영하였다: ideal head position, $5^{\circ}$, $10^{\circ}$ up, $5^{\circ}$, $10^{\circ}$ down, $5^{\circ}$, $10^{\circ}$ right up, and $5^{\circ}$, $10^{\circ}$ right rotation. 파노라마 방사선사진 촬영은 디지털 방사선 촬영기(Planmeca ProMax)를 이용하였고 모니터상에서 직접 인접 치아장축을 표시하고 그 사이 각도를 계측하였다. 그 결과 이상적인 두부 위치와 다양한 두부 위치 변화에 따라 촬영한 파노라마 방사선사진 사이에 인접 치아장축 사이의 각도가 대부분 유의한 차이를 보였다. 수평축(X축)을 중심으로 고개를 든 경우, 각 치아들의 장축이 교합평면을 향하여 수렴하는 경향을 보였고 고개를 숙인 경우에는 치근단측을 향하여 수렴하는 경향을 보였으며, 이는 특히 전치부에서 가장 큰 차이를 보였다. 전후방축(Y축)을 중심으로 좌우측으로 고개를 기울인 경우, 교합평면이 올라간 쪽의 치아장축은 치근단측을 향하여 수렴하는 경향을 보였고 교합평면이 내려간 쪽은 교합평면을 향하여 수렴하는 경향을 보였다. 수직축(Z축)을 중심으로 고개를 좌우로 회전시킬 때, 고개를 돌린 쪽의 측절치와 견치는 치근단측을 향하여 수렴하고 반대측의 측절치와 견치는 교합평면을 향하여 수렴하였다. 이상의 결과들로 볼 때 파노라마 방사선사진 촬영 시 두부의 위치 변화에 따라 치근 평행도가 달라지기 때문에 환자를 올바르게 위치시키는 것이 중요하며, 교정 환자에서 파노라마 방사선사진을 이용하여 치근 평행도를 평가할 때 교합평면의 경사(전후방, 좌우측방)나 악궁의 비대칭 등이 반드시 고려되어야 할 것이다.

옷가지와 안경 착용에 따른 머리전달함수의 스펙트럼 왜곡 (Spectral Distortion of Head-Related Transfer Function Due to Wearing Clothes and Glasses)

  • 조현;황성목;이윤재;박영진;박윤식
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.103-107
    • /
    • 2009
  • Because individual HRTFs (Head-Related Transfer Functions) vary from a person to a person, a HRTF database has been measured by researchers to investigate the inter-subject variation, and to generate high fidelity virtual sound image. Individual HRTFs not only vary between subjects but also vary due to wearing clothes and glasses in daily life. However, influence of different dressing condition on the measured HRTF was not sufficiently investigated. To quantify the effect of wearing clothes and glasses, dummy's HRTF is measured in an anechoic chamber with various dressing condition, and is evaluated in the sense of spectral distortion. HRTFs are measured both in the median plane and in the horizontal plane. In the median plane, under 6kHz, effect of different wearing clothes and glasses is negligible. Over 6kHz, however, effect of clothing distorts HRTF about 6dB in the sense of spectral distortion. Moreover, at high frequencies, effect of glasses is no longer negligible. In the horizontal plane, at some azimuths, even additional light cloth over the dummy can change the spectrum of HRTF (6dB spectral distortion) especially when sound source is at contralateral positions. Therefore, HRTF measurement with different wearing conditions can broaden the capability of HRTF customization whose technique utilizes a HRTF database.

  • PDF

Is the SAM phantom conservative for SAR evaluation of all phone designs?

  • Lee, Ae-Kyoung;Hong, Seon-Eui;Choi, Hyung-Do
    • ETRI Journal
    • /
    • 제41권3호
    • /
    • pp.337-347
    • /
    • 2019
  • The specific anthropomorphic mannequin (SAM) phantom was designed to provide a conservative estimation of the actual peak spatial specific absorption rate (SAR) of the electromagnetic field radiated from mobile phones. However, most researches on the SAM phantom have been based on early phone models. Therefore, we numerically analyze the SAM phantom to determine whether it is sufficiently conservative for various types of mobile phone models. The peak spatial 1- and 10-g averaged SAR values of the SAM phantom are numerically compared with those of four anatomical head models at different ages for 12 different mobile phone models (a total of 240 different configurations of mobile phones, head models, frequencies, positions, and sides of the head). The results demonstrate that the SAM phantom provides a conservative estimation of the SAR for only mobile phones with an antenna on top of the phone body and does not ensure such estimation for other types of phones, including those equipped with integrated antennas in the microphone position, which currently occupy the largest market share.

다 관절 재활운동을 위한 생체역학적 운동구현 시스템 개발 (Development of a Biomechanical Motion System for the Rehabilitation of Various Joints)

  • 이용석;백춘석;장재호;심형준;한창수;한정수
    • 대한의용생체공학회:의공학회지
    • /
    • 제25권6호
    • /
    • pp.511-517
    • /
    • 2004
  • 기존의 재활운동 장치들은 상지 또는 하지의 특정한 관절에 대해서만 재활운동이 가능하게 개발되었다. 따라서 여러 관절을 재활시키고자 할 경우, 그에 맞는 다양한 종류의 재활기구 들이 필요하다. 이러한 단점을 보완하기 위하여 본 연구에서는 각 관절에서 이루어지는 다양한 재활운동을 통합 구현하는 CMRS(CIM and Robotics Lab. Multi - joint Rehabilitation System)을 제안하였다. 이 시스템을 위해 인체의 상지 및 하지에 대한 기구학적 특성을 이용하여 각 관절의 회전 특성 및 좌표관계를 조사하였으며, 이와 같은 연구를 바탕으로 재활운동 기구 제작 시 알맞은 메커니즘을 제시하고. 다양한 재활 부위와 이를 재활 운동시키는 헤드부의 위치관계를 연구하였다. 시뮬레이션을 통하여 재활운동 시스템의 가능성을 판별하였고. 안정되고 편리한 위치 조정을 위한 베이스프레임을 개발하였다. 이를 고려하여 최종적으로 8개의 자유도를 가진 CMRS을 개발하였으며 다 관절을 하나의 시스템으로 재활 가능할 것이라 사료 된다.

Reliability of implant stability measuring devices depending on various clinical conditions: an in vitro study

  • Han-Na Lee;Myoung-Sub Kim;Jeong-Yol Lee;Xu Zihan;Jae-Jun Ryu;Ji-Suk Shim
    • The Journal of Advanced Prosthodontics
    • /
    • 제15권3호
    • /
    • pp.126-135
    • /
    • 2023
  • PURPOSE. The aim of this study was to evaluate the reliability of implant stability measuring devices depending on the location of the implant and the position of the patient. MATERIALS AND METHODS. Six implants were installed in different dentate sextants of six artificial bone models. Implant stability was measured in three conditions of the bone model (without mounting on a phantom head, mounted on a phantom head in supine position, and mounted on a phantom head in upright position). A resonance frequency analysis device (Osstell) and two damping capacity analysis devices (Periotest and Anycheck) were used to measure implant stability. The values measured outside the phantom head were treated as controls, and the values inside the phantom head were compared using an independent t-test. RESULTS. Osstell showed different results in two of the six divisions in both the supine and upright positions compared to outside of the mouth (P < .05). Periotest showed different results in all six parts in the supine position and in five parts in the upright position compared to outside of the mouth (P < .05). While Anycheck showed different results in five areas in the supine position compared to outside of the mouth, it showed different results in only one area in the upright position (P < .05). CONCLUSION. In the difficult implant position for the operator to access, the implant stability measuring devices show less reliability. The accessibility of implant is greatly affected in the order of Osstell, Anycheck, and Periotest.

Discrepancies in Soft Tissue Profile of Patients for Orthognathic Surgery between Preoperative Lateral Facial Photograph, Lateral Cephalogram and Supine Position on Operation Table

  • Jung, Young-Eun;Yang, Hoon-Joo;Hwang, Soon-Jung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제34권3호
    • /
    • pp.180-185
    • /
    • 2012
  • Purpose: An accurate preoperative analysis of the patient is essential in orthognathic surgery in order to acquire superior results. In profile, the location of the chin's position may change according to the neck's inclination. This may ultimately affect the amount of surgical movement. During acquisition of cephalometric radiographs, or in supine position, there is a discrepancy in the neck's inclination. This means that there are also various discrepancies between the actual profile and the various preoperative profile images. In the clinical situation, the decision in performing genioplasty usually lies in the analysis of the patient's profile on the operating table at the final stages of orthognathic surgery. This study aims to analyze the different preoperative profile images and to compare their discrepancies. Methods: Fifty eight patients undergoing orthognathic surgery were chosen. These patients were divided into three groups according to angle's classification of malocclusion, as class I, II or III. The right profile of these patients in centric occlusion was taken in natural head position (NHP). This was set as the 'actual profile image.' Another right profile image was taken on the operating table after insertion of the nasotracheal intubation and with muscle relaxants in effect. This was also taken in centric occlusion. The angle (denoted 'A') between the soft tissue glabella-pognion and the true vertical plane was found in the above-mentioned profile images and in the cephalometric radiographs. The differences of these values were analyzed. Results: There were differences in Angle 'A' in all of the preoperative images. These values were however, not statistically significant. Conclusion: In order to gain an esthetic profile during orthognathic surgery, the NHP is shown to be the most reliable position. Images reproducing such head positions should be used in the treatment planning process.