• Title/Summary/Keyword: Various Temperature Condition

Search Result 1,922, Processing Time 0.036 seconds

Properties of Light Weight Foamed Concrete According to Curing Condition (양생조건에 따른 경량기포콘크리트의 특성)

  • Shin, Sang-Chul;Choi, Ji-Ho;Hong, Sung-Rog;Kim, Ji-Ho;Jeong, Ji-Yong;Kim, Jin-Man
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.237-239
    • /
    • 2011
  • This study was performed to investigate the influence of curing temperature on the properties of light weight foamed concrete, manufactured on-site construction according to the various experimental factor such as temperature of material, curing temperature in air(5, 10, 20℃), curing time in air(5, 10, 15hour), and target density of hardened state(0.8, 1.2t/㎥). As a result, the influence of the curing temperature on various properties of foamed concrete is greater than curing time. When increasing temperature and time in air curing, progress of hydration is fast and compressive strength is increasing more and more. However, when considering the productivity, minimum curing time is required 15hours at 5℃, 10hours at 10℃, and 5hours at 20℃. If this condition is not required, there is some crack due to volume expansion on the surface of light weight foamed concrete.

  • PDF

A Study of the Friction Characteristics of Plastics on Lubricated Condition (윤활상태에서 플라스틱의 마찰특성에 관한 연구)

  • 강석춘
    • Tribology and Lubricants
    • /
    • v.8 no.1
    • /
    • pp.48-55
    • /
    • 1992
  • The friction characteristic of plastics (PTFE, Nylon, Acetal and phenolic) was studied on the lubricated condition with a pin on disk machine. Mineral oil without additive (base oil) and water were used as liquid lubricants at the controlled temperature. From the experimental work, it was found out that the coefficient of friction of plastics was controlled by the mechanical properities of plastic more than that of liquid for various load and temperature. Viscosity of liquid has affected on the friction only at low temperature under lighb load. Among the tested plastics, the coefficient of friction of PTFE was the lowest under light load and at low temperature while Nylon at medium load and temperature, and Acetal at heavy load and high temperature. The coefficient of friction of soft plastics like PTFE and Nylon were increased as the load and temperature were increased, while that of hard plastic (Acetal) was decreased and that of thermo setting plastic (phenolic) was mixed. Also for soft plastics, the coefficient of friction under heavy load was always higher than that under light load, while hard plastic was vice versa.

A Ignition Test of Gas Turbine Combustor For High Altitude simulation at Low Temperature Condition (가스터빈 연소기 고공환경 모사 시험을 위한 상압/저온 환경에서의 점화 특성 실험)

  • Kim, Ki-Woo;Kim, Tae-Woan;Kim, Bo-Yeon;Lee, Yang-Suk;Ko, Young-Sung;Jun, Yong-Min
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.553-556
    • /
    • 2009
  • In this study, ignition tests of a gas turbine combustor were performed to evaluate an ignition loop at low temperature condition. An experimental setup was constructed to simulate low temperature condition with a heat exchanger using dry ice as a coolant. Various low temperature conditions could be created by controlling the amount of air though the heat exchanger. The results showed that ignition limit decreased with air temperature.

  • PDF

Field Application to Evaluate the Effect of Various Surface Covered Curing Blankets on Temperature Profile and Crack Occurrence of the Concrete under Hot Weather Condition (서중환경에서 표면피복 양생재 종류변화가 콘크리트의 초기 온도이력 및 균열발생에 미치는 영향에 관한 현장적용성 평가)

  • Han, Min-Cheol;Lee, Sang-Woon
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.5
    • /
    • pp.27-34
    • /
    • 2018
  • Concrete placed under hot weather condition suffers from larger slump loss, rapid moisture evaporation due to high air temperature. Proper measures for material, transportation and curing should be taken to prevent the quality deterioration of the concrete under hot weather condition. In Korea, Although the period of hot weather concrete in Korea occupies only 2 months, there are a lot of quality problems including plastic, drying shrinkage and cold joint. Therefore, the objective of this paper is to investigate and compare the temperature history and crack occurrence of the concrete, which was placed in the actual apartment house construction field under hot weather condition, in response to the application of surface covered curing blankets including PE film, single layer clear bubble sheet, white colored bubble sheet and aluminum metalized bubble sheet. Test results indicated that the application of white colored bubble sheet and aluminum metalized bubble sheet showed most favorable results in terms of reduction in temperature rise and crack occurrence as well as easiness in handling. But, due to light reflection by aluminum metalized bubble sheet, it is believed that white colored bubble sheet is preferable.

A Study on the Correlation of Condition Monitoring Parameters of Functional Machine Failures. (기계시스템 파손에 따른 상태진단 파라미터의 상관관계 해석에 관한 연구)

  • 장래혁;강기홍;공호성;최동훈
    • Tribology and Lubricants
    • /
    • v.18 no.4
    • /
    • pp.285-290
    • /
    • 2002
  • Integrated condition monitoring is required to monitor effectively the machine conditions since machine failures could not be monitored accurately by any single measurement parameter. Application of various condition monitoring techniques is therefore preferred in many cases in order to diagnosis the machine condition. However it inevitably requires lots of maintenance cost and sometimes it could be proved to over-maintenance unnecessarily. This could happen especially when one measurement parameter closely correlates to another. Therefore correlation analysis of various monitoring parameters has to be performed to improve the reliability of diagnosis. In this work, Pearson correlation coefficient was used to analyze the correlation between condition monitoring parameters of an over-loaded machine system where the vibration, wear and temperature were monitored simultaneously. The result showed that Pearson correlation coefficient could be regarded as a good measure for evaluating the availability of condition monitoring technology.

A Study on the Correlation of Condition Monitoring Parameters of Functional Machine Failures. (기계시스템 파손에 따른 상태진단 파라미터의 상관관계 해석에 관한 연구)

  • 장래혁;강기홍;공호성;최동훈
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.252-259
    • /
    • 2001
  • Integrated condition monitoring is required to monitor effectively the machine conditions since machine failures could not be monitored accurately by any single measurement parameter. Application of various condition monitoring techniques is therefore preferred in many cases in order to diagnosis the machine condition. However it inevitably requires lots of maintenance cost and sometimes it could be proved to over-maintenance unnecessarily. This could happen especially when one measurement parameter closely correlates to another. Therefore correlation analysis of various monitoring parameters has to be performed to improve the reliability of diagnosis. In this work, Pearson correlation coefficient was used to analyze the correlation between condition monitoring parameters of an over-loaded machine system where the vibration, wear and temperature were monitored simultaneously. The result showed that Pearson correlation coefficient could be regarded as a good measure for evaluating the availability of condition monitoring technology.

  • PDF

The Tensile Characteristics of Steel Sheets at Various Temperature Conditions (박강판의 온도변화에 따른 인장특성)

  • 이항수;오영근
    • Transactions of Materials Processing
    • /
    • v.10 no.2
    • /
    • pp.101-110
    • /
    • 2001
  • The thermal problem of press work is classified into two cases. First, the temperature of forming die passively rises due to the heating effect of plastic deformation. The warm forming is the second case in which the external heating is applied to the die and blank holder. So, the purpose of this study is to provide database for the forming characteristics at various temperature conditions. In this study, the tensile test was carried out for the commercial steel sheets such as SCPI and SCP3C with the thickness of 0.7mm and 1.4mm respectively. The tensile strength, total elongation, Lankford value and the flow curve have been obtained at the temperature of $25^{\circ}C$, $50^{\circ}C$, $100^{\circ}C$, $150^{\circ}C$, $200^{\circ}C$, $250^{\circ}C$ and $300^{\circ}C$, respectively. From the results, we can see that both the tensile strength and total elongation decrease as the temperature increases. In the light of anisotropy, the effect of thickness is dominant than the material specs. For the temperature dependency of flow curves, there are only small differences for the work-hardening exponent, and the strength intensity decreases monotonically as temperature increases. The present results we useful as input data for the analysis of sheet metal forming processes with the various temperature conditions.

  • PDF

Experimental Study on Natural Ventilation Performance of Double Facade System in Heating Period (난방기 중 이중외피 시스템의 자연환기 성능분석에 관한 실험적 연구)

  • Lee, Keon-Ho;Kim, Hyeon-Soo;Ko, Yung-Woo;Son, Young-Joo
    • KIEAE Journal
    • /
    • v.6 no.2
    • /
    • pp.43-50
    • /
    • 2006
  • A Double Facade System(DFS) is well known as an innovative solution of ecological facade in the west european countries. There are more than 200 various realized DFS in Germany. At the same time, the korean engineers have researched to find out the physical advantages of DFS in the moderate korean climate, which has a very humid summer with high temperature and a dry winter with low temperature. For example, the monthly mean temperature in Korea comes up to 28K, while that in Germany comes up to only 19K. That is, why a other solution of DFS is needed in Korea. This study has experimented the physical performance of the natural ventilation in the heating period. The preheating function of the cold air by DFS can improve no doubt the performance of the natural ventilation at the cold season as well as spring and autumn. The physical difference between single and double facade on natural ventilation has been tested at the newly constructed laboratory, which can turn $360^{\circ}$ to confirm the characteristic of a facade with the various directions. The results show the natural ventilation of the DFS has definitely much more comfortable than that of the single facade system. The air velocity of the inflow as well as the air temperature in the DFS provide a more stable condition than in the SFS. The theoretical limit(air velocity max 0.2m/s, air temperature min. $18^{\circ}C$, temperature difference between 100mm and 1700mm height max. 3K) on the indoor comfortableness doesn't go over in the DFS. On the other hand, the SFS showed an unstable condition with an excess of comfortableness limit on air velocity as well as temperature. In view of the researching results so far achieved, the research came to a conclusion, that the DFS can provide a more comfortable indoor condition by the preheating in the heating period than a SFS, and the period of natural ventilation in winter time could be definitely increased at the DFS.

Multi-phase Accelerating Test Method of Thermal Aging Considering Heat Generation of Electric Equipment (전기기기의 발열을 고려한 다단계 가속열노화 방법)

  • Lim, Byung-Ju;Park, Chang-Dae;Chung, Kyung-Yul
    • The KSFM Journal of Fluid Machinery
    • /
    • v.16 no.5
    • /
    • pp.18-23
    • /
    • 2013
  • Thermal aging test is performed to qualify the life time of equipment in thermally aged condition. Due to long life time more than 10 years like as in power plant, the equipment is subjected to the accelerated thermal aging condition which is able to shorten the long aging test period by increasing aging temperature. Normally, conservatism of thermal aging test causes to impose unbalanced and excessive thermal load on components of the equipment, and deformation and damage problems of the components. Additionally, temperature rise of each component through heat generation of the electric equipment leads to long-term problem of the test period. Multi-phase accelerating aging test is to perform thermal aging test in multiple aging conditions after dividing into groups with various components of equipment. The groups might be classified considering various factors such as activation energy, temperature rise, glass transition temperature and melting temperature. In this study, we verify that the multi-phase accelerating aging test method can reduce and equalize the thermal over load of the components and shorten aging test time.

The investigation of conservation methods and destruction regions of papers under the various temperature and humidity changes (온.습도 변화에 따른 양지의 손상원인 및 보존방안 연구)

  • Lee, Hye-Yun;Chung, Yong-Jae;Lee, Kyu-Sik;Han, Sung-Hee
    • 보존과학연구
    • /
    • s.21
    • /
    • pp.145-175
    • /
    • 2000
  • To examine the method for preservation of papers, 9 kinds of papers were purchased and pretreated for 6 months with various artificial conditions which were controlled as 3 temperature classes($20^{\circ}C$, $80^{\circ}C$, $-20^{\circ}C$&$20^{\circ}C$) and 4 humidity classes(40%, 60%, 80%, 100%).Whiteness, acidity and folding endurance were measured to examine the state of papers pretreated under each condition. From the resultexamining the state, all the papers were best condition at low temperature($20^{\circ}C$) and low humidity(40%) and damaged at high temperature($80^{\circ}C$) and high humidity(100%).The values of whiteness, acidity, and folding endurance were measure din relation with deterioration of papers. According to damage of papers caused by the chemical agent, papers became to be acidic, increased color difference and reduced the force of folding endurance. The effect of change of temperature($-20^{\circ}C$&$20^{\circ}C$) on degradation of papers was not well acquired. Because the period of investigation was not long enough to acquire the data. So the more studies are needed to find the cause of damage of papers.

  • PDF