Loss Minimization Control of Interior Permanent Magnet Synchronous Motors Considering Self-Saturation and Cross-Saturation

  • Pairo, Hamidreza;Khanzade, Mohammad;Shoulaie, Abbas
    • Journal of Power Electronics
    • /
    • 제18권4호
    • /
    • pp.1099-1110
    • /
    • 2018
  • In this paper, a loss minimization control method for interior permanent magnet synchronous motors is presented with considering self-saturation and cross saturation. According to variation of the d-axis and q-axis inductances by different values of the d-axis and q-axis components of currents, it is necessary to consider self-saturation and cross saturation in the loss minimization control method. In addition, the iron loss resistance variation due to frequency variation is considered in the condition of loss minimization. Furthermore, the loss minimization control method is compared with maximum torque per ampere (MTPA), unity power factor (UPF) and $i_d=0$ control methods. Experimental results verify the performance and proper dynamic response of the loss minimization control method with considering self-saturation and cross saturation.

Study of FFF with Optically-Controlled Microwave Pulses in Non-uniform Plasma Layer

  • Wang, Xue;Seo, Dong-Ho;Kim, Yong-K.
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.149-150
    • /
    • 2009
  • In this paper we study on the semiconductor characteristic by calculating the variation of reflection function in microstrip lines, which has open-ended termination containing an optically induced plasma region. The variation of impedances resulting from the presence of plasma has evaluated with time and frequency domain. The responses have been also evaluated theoretically for changing the phase of the variation in the reflection.

  • PDF

Impact of the Gain-saturation Characteristic of Erbium-doped Fiber Amplifiers on Suppression of Atmospheric-turbulence-induced Optical Scintillation in a Terrestrial Free-space Optical Communication System

  • Jeong, Yoo Seok;Kim, Chul Han
    • Current Optics and Photonics
    • /
    • 제5권2호
    • /
    • pp.141-146
    • /
    • 2021
  • We have evaluated the suppression effect of atmospheric-turbulence-induced optical scintillation in terrestrial free-space optical (FSO) communication systems using a gain-saturated erbium-doped fiber amplifier (EDFA). The variation of EDFA output signal power has been measured with different amounts of gain saturation and modulation indices of the optical input signal. From the measured results, we have found that the peak-to-peak power variation was decreased drastically below 2 kHz of modulation frequency, in both 3-dB and 6-dB gain compression cases. Then, the power spectral density (PSD) of optical scintillation has been calculated with Butterworth-type transfer function. In the calculation, different levels of atmospheric-turbulence-induced optical scintillation have been taken into account with different values of the Butterworth cut-off frequency. Finally, the suppression effect of optical scintillation has been estimated with the measured frequency response of the EDFA and the calculated PSD of the optical scintillation. From our estimated results, the atmospheric-turbulence-induced optical scintillation could be suppressed efficiently, as long as the EDFA were operated in a deeply gain-saturated region.

Properties and Structure of High Frequency Soft Magnetic Nano-composite Films

  • Ohnuma, Shigehiro;Masumoto, Hiroshi
    • Journal of Magnetics
    • /
    • 제16권4호
    • /
    • pp.403-407
    • /
    • 2011
  • Metal-insulator type, nano-granular soft magnetic films have been reviewed from the viewpoint of high frequency magnetic materials. The formation of nano-granular structure is related to the magnitude of heat of formation of intergranule materials. Variation of the ratio of granule phase to intergranule phase in the film is found to produce various characteristics in the magnetic properties of the film. The HRTEM observation reveals that neighboring granules in the film with above 60 at.% Co, contact at considerable points and the films show soft magnetic properties which are explainable in terms of the random anisotropy model for nano-crystalline materials. Addition of Ni group elements in Co-O based films enhances their anisotropy field up to 400 Oe and they exhibit excellent frequency response of permeability. Also, large electromagnetic noise suppression effect is demonstrated as one of their potential applications.

Duplex Pulse Frequency Modulation Mode Controlled Series Resonant High Voltage Converter for X-Ray Power Generator

  • Chu Enhui;Ogura Koki;Moisseev Serguei;Okuno Atsushi;Nakaoka Mutsuo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.295-300
    • /
    • 2001
  • A variety of high voltage DC power supplies employing the high frequency inverter are difficult to achieve soft switching considering a quick response and no overshoot response under the wide load variation ranges which are used in medical-use x-ray high voltage generator from 20kV to 150kV in the output voltage and from 0.5mA to 1250mA, respectively. The authors develops soft switching high voltage DC power supply designed for x-ray power generator applications, which uses series resonant inverter circuit topology with a multistage voltage multiplier instead of a conventional high voltage diode rectifier connected to the second-side of a high-voltage transformer with a large turn ratio. A constant on-time dual mode frequency control scheme operating under a principle of zero-current soft switching commutation is described. Introducing the multistage voltage multiplier, the secondary transformer turn-numbers and stray capacitance of high-voltage transformer is effective to be greatly reduced. It is proved that the proposed high-voltage converter topology with dual mode frequency modulation mode control scheme is able to be the transient response and steady-state performance in high-voltage x-ray tube load. The effectiveness of this high voltage converter is evaluated and discussed on the basis of simulation analysis and observed data in experiment.

  • PDF

Temperature-dependent Differences in Heading Response at Different Growth Stages of Rice

  • Lee, HyeonSeok;Choi, MyoungGoo;Lee, YunHo;Hwang, WoonHa;Jeong, JaeHyeok;Yang, SeoYeong;Lim, YeonHwa;Lee, ChungGen;Choi, KyungJin
    • 한국작물학회지
    • /
    • 제64권3호
    • /
    • pp.213-224
    • /
    • 2019
  • There is an increasing frequency in the occurrence of abnormal weather phenomena such as sharp increases and decreases in temperature. Under these weather conditions, the heading time of rice changes unexpectedly, which poses problems in agriculture. Therefore, we investigated the effect of temperature on the heading response at different growth stages in rice. During the period from transplanting to heading, the plants were subjected to different temperature treatments, each for a 9-day period, to observe the heading response. For the heading date analysis, "heading date" was defined as the number of days from transplanting to the appearance of the first spikelet. We found that the influence of temperature increased in the order of rooting stage, followed by meiosis, early tillering, spikelet differentiation, and panicle initiation stage in all ecological types and cultivars. In particular, unlike the results reported previously, the effect of temperature on heading during the photo-sensitive period was very small. Meanwhile, the influence of temperature on vegetative growth response at different growth stages was not consistent with heading response. These results can be used as basic data for predicting the variation in heading date owing to temperature variation at each growth stage. In addition, we propose that the concept of day length should be included in determining the influence of temperature on the photo-sensitive period.

가변 히스테리시스 전류제어기를 이용한 연계형 태양광 인버터의 제어 (Control of Grid-Connected Photovoltaics Inverter Using Variable Hysteresis Band Current Controller)

  • 최연옥;조금배;백형래;김시경;유권종;송진수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.525-527
    • /
    • 1996
  • Hysteresis current control is one of the simplest techniques used to control currents for high speed drive systems, because of its simplicity of implementation, fast current control response, and inherent peak current limiting capability. However the conventional fixed-band hysteresis control has a variable switching frequency throughout the fundamental period, and consequently the load current harmonics spreaded on the wide frequency range. In this paper, a simple, novel alterative approach is proposed for a variable-hysteresis band current controller which uses feedback techniques to achieve constant switching frequency with good dynamic response. The method is easily implemented in hardware, the resultant controller is easily tuned to a particular load, and has good immunity to variation in PV parameter and dc supply voltage.

  • PDF

한반도 지진특성을 고려하여 모사된 강진동에 대한 가속도 응답스펙트럼 (The Acceleration Response Spectrum for Simulated Strong Motions Considering the Earthquake Characteristics of the Korean Peninsula)

  • 김성균
    • 한국지구과학회지
    • /
    • 제28권2호
    • /
    • pp.179-186
    • /
    • 2007
  • 응답스펙트럼은 내진설계에 있어서 중요한 기초자료의 하나이다. 응답스펙트럼을 얻기 위하여, 한반도에서 발생하는 지진들의 지진원 특성에 근거하여 다수의 강진동을 Boore(2005)에 의해 개발된 컴퓨터 프로그램 SMSIM을 사용하여 모사하였다. 여러 연구결과들에 대한 충분한 검토를 통하여, 모사에 필요한 입력자료들을 선정하였다. 모사된 강진동으로부터 얻은 응답스펙트럼은 가속도 1.0 g에 대하여 정규화하여 미국 원자력위원회(1973)의 표준응답스펙트럼과 비교하였다. 이 연구에서 얻어진 응답스펙트럼의 스펙트럼 진폭은 대략 10 Hz 이상의 고주파 대역에서 표준 응답스펙트럼 값에 비하여 큰 것으로 나타났다. 또한 응력강하량의 변화에 따른 응답스펙트럼의 변화를 평가하였다. 그 결과 큰 응력강하량에 대한 응답스펙트럼의 스펙트럼 진폭은 저주파 범위내에서 큰 값을 나타냄을 제시하였다.

시간영역 인공지진파 생성 (Generation of Synthetic Ground Motion in Time Domain)

  • 김현관;박두희;정창균
    • 토지주택연구
    • /
    • 제1권1호
    • /
    • pp.51-57
    • /
    • 2010
  • 국내에서 내진설계의 중요성이 점차적으로 부각되고 있으며 이에 따라 설계 시 동적 지진해석의 수행빈도가 높아지고 있다. 동적 지진해석을 수행하기 위한 가장 중요한 입력변수 중 한가지는 입력지진파이다. 그러나 현재 국내에서는 지진학적 검토 없이 미국, 일본 등에서 계측된 강진 기록을 입력지진파로 사용하거나 주파수영역에서 생성된 인공지진파를 사용하고 있다. 국외 계측 지진기록은 지진 규모에 따라 변화하는 지속시간과 에너지를 고려할 수 없어서 국내 지진환경에는 적합하지 않으며, 주파수 영역에서 생성되는 설계응답스펙트럼에 맞춤형 인공지진파는 실제 지진기록과 주파수 특성이 상이한 문제가 있다. 본 연구에서는 이와 같은 입력지진파의 문제점을 극복하기 위하여 시간영역에서 수행되는 응답스펙트럼 맞춤형 인공지진파 알고리즘을 적용하여 입력 지진파를 생성하였다. 생성된 지진파는 계측 지진기록의 고유한 성질인 Non-stationary 특성을 보존하며 동시에 설계 응답스펙트럼과 거의 완벽한 일치성을 보이는 것으로 나타났다.

터빈형과 기어모터형 유량계의 동특성 검토 (An Investigationi into the Dynamic Characteristics of Turbine and Gear Motor Type Flowmeters)

  • 예용택
    • 한국생산제조학회지
    • /
    • 제9권3호
    • /
    • pp.83-89
    • /
    • 2000
  • In hydraulic control system turbine and gear motor type flowmeters are widely used to measure the flow rate under steady flow conditions. With the recent growth of interest in the measurement of instantaneous values of unsteady flow rate the test of the transient response of these flowmeters are in some significance. however an unsteady flow rate mea-surment and its calibration method with a fast response and a high accuracy have not beendeveloped. In this research particularly the dynamic characteristics of turbine and gear motor type flowmeters are investigated experimentally and simple mathematical models are proposed. The measured flow rate waveforms are compared with those by remote instan-taneous flow rate measurement method(RIFM) which has been developed by author and used for calibration As the result of frequency response test gain and phase between the measured flow rate waveforms by turbine type flowmeter and those estimated by RIFM are in good agreement up to 70Hz For the gear motor type flowmeter th simulated results by a math-ematical model proposed here agree well with the experiment nearly up to 100Hz. Also it if sound that the pressure drop across the flowmeter is increased in proportion to the frequency of the flow rate variation in a high frequency region of more than 100Hz. It can be explained that the dealy of gear motor type flowmeter in high frequency regionis mainly attributed to a first order delay consisting of the inertia of gears and internal leakage of the gear motor.

  • PDF