• Title/Summary/Keyword: Variable speed generator

Search Result 184, Processing Time 0.024 seconds

PSCAD/EMTDC Simulation Model of Variable Speed Wind Power Generation System Using Permanent Magnet Synchronous Machine (영구자석형 동기기에 의한 가변속 풍력발전 시스템의 PSCAD/EMTDC 시뮬레이션 모델 개발)

  • Kim Jeong-Jae;Song Seung-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.6
    • /
    • pp.610-617
    • /
    • 2005
  • A variable speed wind turbine simulation model for grid connection is developed based on PSCAD/EMTDC. The model consists of wind model, rotor dynamics, synchronous generator, power converter, transformer, distribution line and infinite bus. Implementation of blade characteristics and power converter control strategies are included. Several transient case studies are performed including wind speed change, local load change and grid-side voltage unbalance using developed simulation model. The results of this work can be utilized for study of actual interaction between wind turbine and grid for reliable operation and protection of power system.

Variable Speed Operation of Diesel Engine-Generator based on Sliding Mode Control (슬라이딩 모드 제어를 이용한 디젤엔진-발전기의 가변속 제어)

  • Choi, Ik-Chan;Lee, Dong-Choon
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.284-285
    • /
    • 2017
  • 본 논문에서는 슬라이딩모드 제어이론을 이용한 디젤엔진발전기의 가변속 제어기법을 제시한다. 부하의 변동에 대해 최적효율 운전점으로 동작시키기 위해 가변속이 필요하며 이를 위해 슬라이딩모드 속도제어기를 설계한다. 시뮬레이션을 통해 제어기의 성능을 검증한다.

  • PDF

Control Algorithm for Wind Turbine Simulator with Variable Inertia Emulation (가변관성 모의 기능을 가진 풍력터빈 시뮬레이터의 제어 알고리즘)

  • 정병창;정세종;송승호
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.3
    • /
    • pp.266-273
    • /
    • 2003
  • A wind turbine simulator is developed for the emulation of variable input torque from the wind energy without actual rotor blades using motor-generator set. The torque command of dc motor is calculated from the characteristic equation of rotor blade during the change of wind speed. Especially the proposed control algorithm takes into account the fact that the moment of inertia of blade is much larger than that of driving motor. If you select the desired value of inertia, the stored/restored energy of the inertia during acceleration/deceleration can be compensated effectively resulting the only net torque is delivered to the generator. The simulator set-up has been designed and implemented using a do motor and drive. Feasibility of the proposed algorithm is verified by computer simulations and experiments.

Pitch Angle Control of Wind Turbine based on Variable PID Gains (가변적인 PID 이득에 기초한 풍력발전 시스템의 피치제어)

  • Ko, Jung-Min;Yang, Soo-Youg;Boo, Chang-Jin;Kim, Ho-Chan;Huh, Jong-Chul;Lee, Junghoon;Kang, Min-Jae
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.23 no.1
    • /
    • pp.1-6
    • /
    • 2013
  • For regulating generator speed above the rated wind, versatile methods have been published based on PID. However, these methods with the fixed PID gains could not guarantee that the controller works well in the whole area. In this paper, variable PID gain method has been suggested to overcome this problem. The sensitivity of power to blade pitch angle changes according to wind speed. The variable PID gain function has been derived from this sensitivity.

Sensorless Fuzzy MPPT Control for a Small-scale Wind Power Generation System with a Switched-mode Rectifier (SMR 회로를 이용한 소형풍력발전 시스템의 센서리스 퍼지 MPPT제어)

  • Lee, Joon-Min;Park, Min-Gi;Kim, Young-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.7
    • /
    • pp.916-923
    • /
    • 2014
  • This paper proposes a low-cost switched-mode rectifier (SMR) for a small-scale wind turbine with a permanent magnet synchronous generator (PMSG) system. Also, a sensorless Fuzzy MPPT control is realized by the proposed system. In the PMSG system with the SMR, the synchronous impedance can be replaced as the input inductor of a boost converter. Moreover, the sensorless MPPT control using the Fuzzy technique is carried out by the duty-ratio regulation of the SMR. The relation between the generating power and the duty-ratio is ruled by the chain rule. The wind turbine model is implemented by the squirrel cage induction motor and generated the variable torque when the generator speed is varied. To verify the performance of the proposed system, simulation and experimental results are executed.

Simulation of Dynamic Torsional Vibration during Grid Low Voltage in a PMSG Wind Power Generation System (PMSG 풍력발전시스템에서 전원 저전압 발생시 비틀림 진동 동특성 시뮬레이션)

  • Kwon, Sun-Hyung;Song, Seung-Ho;Choi, Ju-Yeop;Jeong, Seung-Gi;Choy, Ick
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.242-244
    • /
    • 2011
  • A wind generator system model includes wind model, rotor dynamics, synchronous generator, power converter, distribution line and infinite bus. This paper investigates the low-Voltage Ride-Through capability of PMSG wind turbine in a variable speed. The drive train of a wind turbine on 2-mass modeling can observe the shaft torsional vibration when the low-voltage occur. To reduce the torsional vibration when the low-voltage occur, this paper designs suppression control algorithm of the torsional vibration and implements simulation. A Matlab/Simulink is used to investigate the response during the transient state.

  • PDF

Enhanced Proportional-Resonant Current Controller for Unbalanced Stand-alone DFIG-based Wind Turbines

  • Phan, Van-Tung;Lee, Hong-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.3
    • /
    • pp.443-450
    • /
    • 2010
  • An enhanced control strategy for variable-speed unbalanced stand-alone doubly-fed induction generator-based wind energy conversion systems is proposed in this paper. The control scheme is applied to the rotor-side converter to eliminate stator voltage imbalance. The proposed current controller is developed based on the proportional-resonant regulator, which is implemented in the stator stationary reference frame. The resonant controller is tuned at the stator synchronous frequency to achieve zero steady-state errors in rotor currents without decomposing the positive and negative sequence components. The computational complexity of the proposed control algorithm is greatly simplified, and control performance is significantly improved. Finally, simulations and experimental results are presented to verify the feasibility and the robustness of the proposed control scheme.

Comparison of Various Methods to Mitigate the Flicker Level of DFIG in Considering the Effect of Grid Conditions

  • Kim, Yun-Seong;Marathe, Aditya;Won, Dong-Jun
    • Journal of Power Electronics
    • /
    • v.9 no.4
    • /
    • pp.612-622
    • /
    • 2009
  • The short circuit ratio (SCR) of a given grid is able to show the stability of the system in the case of unwanted elements, such as wind turbulence. This paper presents the simulation of a model of the doubly fed induction generator in the simulation software PSCAD/EMTDC. This model has been used to study flicker during continuous operation and the effect of SCR and grid impedance angle on flicker emission. Simulation results show that compensation of the stator reactive power is an effective method to considerably reduce the flicker levels, irrespective of the grid conditions.

Protection relaying algorithm for DFIG using a DQ equivalent circuit (DQ 등가회로를 이용한 DFIG 보호계전방식)

  • Kang, Yong-Cheol;Lee, Ji-Hoon;Jang, Sung-Il;Kim, Yong-Gyun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.23-24
    • /
    • 2007
  • Most of modern wind turbines employs a doubly-fed induction generator (DFIG) system because it has many advantages due to variable-speed operation, relatively high efficiency and it small converter size. The DFIG system uses a wound rotor induction machine so that the magnetizing current of the generator can be fed from both the stator and the rotor. This paper presents a protection relaying algorism for DFIG using the DQ equivalent circuits. The induced voltages calculated from the stator and rotor sides are nearly the same in the steady state. They become different in the DQ equivalent circuits during an internal fault. The proposed algorithm compares the inducted voltages estimated from the stator and the rotor circuit converted into the stationary reference frame. If the difference between the induced voltages exceeds the threshold, the proposed algorithm detects an turn-to-turn fault.

  • PDF

Modeling and Filtering of dv/dt Voltage Stress at Generator Terminal Due to Long Cable Between Inverter and Generator in Variable Speed Wind Energy Conversion System (가변속 풍력발전시스템의 인버터-발전기간 케이블 길이에 따른 풍력발전기 dv/dt 전압 모델링 및 저감대책)

  • Park, Chan-sol;Ham, Do-Hyun;Song, Seung-Ho;Kwon, Oh jung;Kang, Shin il
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.455-456
    • /
    • 2014
  • 본 논문에서는 인버터 스위치의 PWM 펄스 전압에 의해 발생하는 발전기 단자의 과전압 현상을 해석하기 위해, 전력 케이블과 발전기의 고주파 모델링을 제시하고, 이에 의한 과전압 현상을 해석한다. 또한, 이 과전압 현상을 억제하기 위한 적절한 형태의 인버터 출력단 dv/dt 필터를 설계하고, 선정된 dv/dt 필터 토폴로지의 필터 파라미터의 범위를 제시한다.

  • PDF