• 제목/요약/키워드: Variable speed drives

검색결과 111건 처리시간 0.026초

CORRECTION OF SWITCHING DEAD TIMES IN PWM INVERTER DRIVES

  • Lee, Kun-Yong
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 추계학술대회 논문집 학회본부
    • /
    • pp.287-290
    • /
    • 1990
  • The paper describes the correction of the switching dead times avoiding a bridge leg short circuit in pulse width modulated voltage sorce inverters. The co consequences on AC variable speed drives with synchronous and asynchronous motors are described by harmonic analysis and by computer simulation.

  • PDF

퍼지 가변스위칭 섹터기법를 이용한 유도전동기의 직접토크 제어 (Direct Torque Control for Induction Motors Using Fuzzy Variable Switching Sector)

  • 윤인식;서영민;류지수;이기상;홍순찬
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.233-233
    • /
    • 2000
  • Direct torque control (DTC) scheme provides a very quick torque response without the complex field-orientation block and inner current regulation loop. DTC is known as an appropriate scheme for high power induction motet drives because it can be used at lower switching frequency. There are two major drawbacks with the application of DTC schemes : one is large current harmonics due to flux drooping in a low speed range, the other is that the inverter switching frequency is varying according to motor parameters and operating speed. Switching devices in the power electronics drives should be supported for relatively high switching frequency. In this paper, a P-type fuzzy controller to realize the variable switching sector scheme and a PID-type fuzzy switching frequency regulator are adopted. A meaningful contribution of this paper is to propose a simple realization scheme of the fuzzy switching frequency regulator. Simulation results show the effectiveness of those propositions.

  • PDF

Voltage Doubler를 이용한 4-스위치 3상 BLDC 전동기 구동 알고리즘 (Driving Algorithm on Three Phase BLDC Motor Applied 4-Switch using Voltage Doubler)

  • 윤용호;이정석;원충연
    • 전기학회논문지P
    • /
    • 제60권1호
    • /
    • pp.48-52
    • /
    • 2011
  • Over the years, traditionally, six-switch three-phase inverters have been widely utilized for variable speed alternating current motor drives. Recently, some efforts have been made on the application of four-switch three phase inverter for uninterruptible power supply and variable speed drives. This is due to some advantages of the four-switch three phase inverter over the conventional six-switch three-phase inverters such as reduced price due to reduction in number of switches, reduced switching losses, reduced number of interface circuits to supply logic signals for the switches, simpler control algorithms to generate logic signals, less chances of destroying the switches due to lesser interaction among switches, and less real-time computational burden. However such as slow di/dt and speed limitation, are the inherent characteristics and main drawbacks of the four-switch configuration. Those problems can be overcome in conjugation with Voltage-doublers which has additional advantage, such as unity power factor correction.

Low-Cost Position Sensorless Switched Relutance Motor Drive Using a Single-Controllable Switch Converter

  • Yang, Hyong-Yeol;Kim, Jae-Hyuck;Krishnan, R.
    • Journal of Power Electronics
    • /
    • 제12권1호
    • /
    • pp.75-82
    • /
    • 2012
  • Elimination of rotor position sensors mechanically coupled with the rotor shaft is attractive to variable speed drives primarily due to increased system reliability and cost reduction. In this regard, search for a simple and robust position sensorless control has been intensified in past few years specifically for low-cost, high-volume applications such as home appliances. This paper describes a new parameter insensitive position sensorless control for switched reluctance motor (SRM) drives satisfying such a need in this market segment. Two consecutive switch-on times of the controllable switch in hysteresis current control are compared to estimate the rotor position and speed. The proposed sensorless control algorithm is very simple to implement since it does not depend on extensive computation or any additional hardware. In addition, the proposed method is robust in that its dynamic performance is least affected by system parameter variations. The proposed approach is demonstrated on a single-controllable-switch-converter-driven SRM with two-phases that lends itself to a system with low cost and compact packaging which comes close to the intended applications. Analysis and simulation results followed by experimental verification are presented to demonstrate the feasibility of the proposed sensorless control method.

The Analysis of Life Cycle Cost and Cooling Water Circulating Pump Energy Saving According to Variable Speed Pressure Differential Setpoint Control Strategy

  • Kim, Seo-Hoon;Kim, Jong-Hun;Jang, Cheol-Yong;Song, Kyoo-dong
    • KIEAE Journal
    • /
    • 제15권4호
    • /
    • pp.37-43
    • /
    • 2015
  • Purpose : The study applied control strategy to reduce through optimal control and operation of pump by applying control on variable speed to the circulation pump of HVAC system in the office building. The study has the purpose to review validity of control on variable speed as ESMs(Energy Saving Measures) and establish the control technology on variable speed pump. The study performed reduction analysis of building energy and economic evaluation of pump through energy effectiveness control strategy of HVAC system. Method: The study sought possible reduction through energy control strategy which can provide proper flow fitting to building load by applying control on variable speed pump. The study applied control strategy to reduce through pressure differential set-point control and operation of pump by applying control on variable speed to the circulation pump of HVAC system in the office building. Result : The results showed that about 16-35% of pump energy could be saved by using these optimal control strategies. In the result of analysis on 10 years life cycle cost of analysis on payback period of initial investment pump, variable speed pump control showed 5.1 years.

차량용 SRM의 가변속 구동을 위한 퍼지 제어기 설계 (Design of Fuzzy Logic Controller for a SRM Variable Speed Drive on Vehicle)

  • 송병섭;엄기명;윤용호;원충연;김덕근
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2000년도 학술대회논문집
    • /
    • pp.193-198
    • /
    • 2000
  • Switched reluctance motor drives have been finding their applications in the variable speed drives due to their relatively low cost, simple and robust structure, controllability and high efficiency. Fuzzy control does not need any model of plant. It is based on plant operator experience and heuristics. Fuzzy control is basically adaptive and gives robust performance for plant parameter variation. This paper deals with the sped control of switched reluctance motor using fuzzy controller with 7-rule based fuzzy logic. The proposed fuzzy controller is superior to the control performance of the conventional PI controller. The fuzzy controller is implemented by 80C196KC, 16 bit one-chip microcontroller.

  • PDF

개선된 슬라이딩 모드 관측기에 의한 유도전동기의 센서리스 속도제어 (Sensorless Speed Control of Induction Motor by an Improved Sliding Mode Observer)

  • 장민영;김상균;권영안
    • 전기학회논문지
    • /
    • 제57권9호
    • /
    • pp.1552-1554
    • /
    • 2008
  • Recently, sensorless induction motor drives have been much studied due to several advantages. Sensorless drives eliminate the additional mounting space, increase the reliability in harsh environments, and reduce the cost of a motor. This paper investigates an improved sliding mode observer for the sensorless speed control of an induction motor. The proposed control strategy is the sliding mode observer with a variable boundary layer for a low-chattering and fast-response control. The proposed sensorless-algorithm is verified through the simulation and experimentation.

Energy Saving with Conversion Speed Drive of Cooling Tower Fans

  • Burapanonthachai, Araya;Chaikla, Amphawan;Trisuwannawat, Thanit;Julsereewong, Prasit;Chansangsuk, Dumri
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.1017-1022
    • /
    • 2004
  • This paper presents the conversion speed drive of the cooling tower fans from constant to variable speed. The speed of fan is adjusted using variable speed drives. Since the ambient temperature of cooling tower is varied seasonally, an economic evaluation was performed to determine the potential annual savings. The performances of the proposed technique were observed using cooling tower fans of chemical plant in Thailand as an illustrative case study. The experimental results demonstrating the energy savings fork cooling process and some economic benefits are obtained.

  • PDF

Characteristic of Induction Motor Drives Fed by Three Leg and Five Leg Inverters

  • Talib, Md. Hairul Nizam;Ibrahim, Zulkifilie;Rahim, Nasrudin Abd.;Hasim, Ahmad Shukri Abu
    • Journal of Power Electronics
    • /
    • 제13권5호
    • /
    • pp.806-813
    • /
    • 2013
  • This paper aims to compare the performance of three phase induction motor drives using Five Leg Inverter (FLI) and Three Leg Inverter (TLI) configurations. An Indirect Field Oriented Control (IFOC) method using a TLI is well established and incorporated for high performance speed drives in various industries. The FLI dual motor drive system on the other hand shows good workability in the independent control of two induction motor drives simultaneously. In this experiment, the IFOC method is utilized for both drive systems, and Space Vector Pulse Width Modulation (SVPWM) is used to generate pulses for both inverters. For the FLI, the Double Zero Sequence (DZS) Injection technique is used to generate the modulation signal. The complete experiment setup is done by using a DSpace 1103 controller board. The individual motor performances are analyzed using similar schemes, equipment setups and controller parameter values. The results show similar speed performance response capability between the single motor operation using a TLI system and the two motor operation using a FLI system based on the variable speed range either in forward or reverse operation. They also show similar load rejection abilities. However, the single motor with a TLI has a better power quality aspect such as ripple current and total harmonics distortion (THD).

유도전동기 직접토크제어를 위한 새로운 퍼지 가변스위칭 섹터기법 (New Fuzzy Variable Switching Sector Technique for DTC on Induction Motor Drives)

  • 류지수;이기상;홍순찬
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 추계학술대회 논문집
    • /
    • pp.11-14
    • /
    • 2001
  • Direct torque control (DTC) scheme provides a very quick torque response without the complex field-orientation block and inner current regulation loop. DTC is known as an appropriate scheme for high power induction motor drives because it can be used at lower switching frequency There are a major drawbacks with the application of DTC schemes it is large current harmonics due to flux drooping in a low speed range. In order to solve the problem, the fuzzy variable switching sector scheme are adopted in this paper. A meaningful contribution of this paper is to propose a simple realization scheme of the fuzzy variable switching sector technique. Experimental results show the effectiveness of this proposition.

  • PDF