• Title/Summary/Keyword: Variable frequency control

Search Result 532, Processing Time 0.024 seconds

Influence of perceived patient safety culture on patient safety management activity in the dental hygienists (치과위생사의 환자안전문화 인식이 환자안전관리활동에 미치는 영향)

  • Lee, Da-Jung;Han, Su-Jin
    • Journal of Korean society of Dental Hygiene
    • /
    • v.16 no.6
    • /
    • pp.863-877
    • /
    • 2016
  • The study aimed to investigate the influence of perceived patient safety culture on patient safety management activity in the dental hygienists. Methods: A self-reported questionnaire was completed by 292 dental hygienists in Seoul, Incheon and Gyeonggido from March 1 to April 8, 2016. The questionnaire consisted of general characteristics of the subjects (9 items), patient safety culture (44 items), and patient safety management activity (25 items) by Likert 5 point scale. Data were analyzed by t test, one way ANOVA, stepwise multiple regression test, and post-hoc Tukey test using SPSS 18.0 program. Results: The perceived patient safety culture was 3.50 on average. Entire organization was the highest score (3.68) and followed the communication process (3.55), the environment of work unit (3.47), the attitude of supervisor/manager (3.45), and the frequency of events reported (2.98). The average of patient safety management activity was 3.71. As for the factors of patient safety culture on patient safety management activity, communication process was the most influential factor (${\beta}=0.268$), and followed the entire organization (${\beta}=0.265$), the environment of work unit (${\beta} =0.166$), the frequency of events reported (${\beta}=0.104$), and among the control variables. Work place proved to be the only significant variable. Conclusions: In order to promote patient safety management activity of dental institutions, the patient safety culture should be created and established. The influence of communication process and patient safety culture at entire organization level was huge. So the environment of work unit and the perceived patient safety culture in the process of reported events were influencing factors. The strategy for patient safety management activity should be considered because of low level of perceived patient safety culture.

DEVELOPMENT OF AC SERVO MOTOR CONTROLLER FOR INDUSTRIAL ROBOT AND CNC MACHINE SYSTEM (산업용 ROBOT와 공작기계를 위한 AC SERVO MOTOR 제어기 개발)

  • Lim, Sang-Gwon;Lee, Jin-Won;Moon, Yong-Ky;Jeon, Dong-Lyeol;Jin, Sang-Hyun;Oh, In-Hwan;Kim, Dong-Il;Kim, Sung-Kwun
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1211-1214
    • /
    • 1992
  • AC servo motor drives, Fara DS series, proposed in this paper can be effectively used in robots, CNC machine tools, and FA system with AC servo motors as actuators. The inverter of the AC servo drive consists of IGBT (Insulated Gate Bipolar Transistor) which have high switching frequency. Noises and vibrations generated in variable speed control of AC servo motors can be greatly reduced due to their high switching frequencies. In the developed servo drive, maximum torque is always generated in the whole speed range by compensating phase shift, which results from the nonlinearies of the AC servo motor during abrupt acceleration and deceleration. Abundant protection functions are provided to prevent abnormal state of the servo motor, and furthermore diverse user options are considered provided for the effective application. The proposed AC servo motor drive is designed to minimize velocity variation with respect to external load, supply voltage, environmental temperature, and humidity, so can be widely used in the fields of factory automation including robots and CNC msachine tools.

  • PDF

Performance Evaluation of the Vibro Hammer with Variable Amplitude by Field Tests (현장실험을 통한 저진동·저소음 진폭가변형 진동해머 성능 평가)

  • Han, Jin-Tae;Lee, Joonyong;Choi, Changho;Park, Jeong-Yel
    • Journal of the Korean Geosynthetics Society
    • /
    • v.14 no.3
    • /
    • pp.1-12
    • /
    • 2015
  • During installing sheet piles for an impermeable wall or a retaining wall, vibratory hammers are widely used. Among vibratory hammers, a hydraulic hammer is used most commonly. However, a hydraulic hammer causes excessive vibration and noise due to resonance by change of natural frequency according to movements of eccentric shaft when the hammer starts and stops. In this study, new variable amplitude type hammer is developed in order to reduce the vibration and noise due to resonance produced in starting and stopping the hammer. By controlling horizontal angle in two pairs of eccentric body inside of the hammer, the amplitude and vibration of the new hammer can be controlled. The performance tests with the new hammer and existing hammers such as the hydraulic hammer and electric hammer are carried out, and the new hammer shows reduced vibration and noise results in comparison with existing hammers from performance tests. Also, this study shows that penetration rates of sheet pile using the new hammer increase due to impellent force of a backhoe in comparison with the electric hammer and penetration rate increase in comparison with a general hydraulic hammer, since the new hammer can control the amplitude during penetration of sheet pile according to soil condition.

Analysis of Signal Integrity of High Speed Serial Interface for Ultra High Definition Video Pattern Control Signal Generator (UHD급 영상패턴 제어 신호발생기를 위한 고속 시리얼 인터페이스의 신호 무결성 분석)

  • Son, Hui-Bae;Kweon, Oh-Keun
    • Journal of Broadcast Engineering
    • /
    • v.19 no.5
    • /
    • pp.726-735
    • /
    • 2014
  • In accordance with 4K UHD(Ultra High Definition) LCD television's higher resolution and data expansion, LCD TV had to face problems such as increasing numbers of cables and tangible skews problems among cables. The V-by-One HS is a new interface technology in the path between the image processing IC and timing control (TCON) board. The variable speed from 600 Mbps to 3.75 Gbps effectively meets the requirements of various different pixel rates. In this paper, we use the V-by-One HS interface to illustrate our proposed simulation method of frequency resonance mode and PCB design approach to model the effects of signal integrity for high speed video signal using an IBIS models.

Experimental Study of Moxibustion's Parameters (구의 Parameters에 대한 실험 연구 -시구의 장수, 일수, 용량, 경혈의 양측효과 비교 및 기전을 중심으로-)

  • Oh Inn Kun;Yun Jeong Ahn;Yu Yun Cho
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.18 no.5
    • /
    • pp.1356-1361
    • /
    • 2004
  • Moxa-combustion therapy make use of heat stimulus and chemicals result form when cauterize the skin with moxa cones to medical cares. However, recently moxibustion have been utilized less than acupuncture for treatment of disease in a practicing oriental physicians. To determine variable parameters (the numbers, the times, the quantities, the locations) affected moxibustion's effects, the gastrin serum level in rats were observed. In experiment, male Spraque-Dawley rats (body wt. 140-160g) were selected. Anything is performed to normal group. Control group were only anesthetized with inhalation in normal group. Experimental group were anesthetized and cauterized with moxa at BL21 by way of direct moxibustion. The size of moxa cone is 1.6±0.2㎎. The moxibustion as 5 times a day for five days has shown most significant effects and the moxibustion as a aquantity of 1, 5, 10 times moxa united one respectly, inverse to quantity in effects. The moxibustion for five days has also shown an most significant effects. The moxibustion at unilateral acupoints BL21 have less effects than bilateral one and these effects had no difference between control group after vagotomy. This results indicate that moxibustion's effects are not direct proportion to moxa cone size and frequency but imply that there is adequate value of moxibustion.

A Research to Minimizing the Effect of Voltage Disturbances on Sensitive Electrical and Electronic Equipment (민감한 전기전자기기의 전압외란에 대한 영향 최소화 연구)

  • 윤갑구
    • Journal of the Korean Professional Engineers Association
    • /
    • v.19 no.2
    • /
    • pp.10-20
    • /
    • 1986
  • This paper describes a countermeasure of electric utilities and customer equipment in order to minimize an effect of sensitive electrical and electronic equipment on the voltage disturbances. After being studied, some schemes to solve were discovered. Firstly, in the electric utilities, the reduction of frequency and influence of voltage drop's time are not easy to realize because of the standpoint of effect and economy. Secondly, in the customer equipment, there are some equipment to minimize the voltage disturbances, Such as an UPSs, a noise suppressors and a power conditioners. One of them should be established on the computer control and automated systems, the electromagnetic switch of delay-release type should be adopted on the electromagnetic switch, the controlling circuit should be adopted on the variable speed motors which is being considered a countermeasure for a momentary under-voltage drops, the luminaire adhering a instantaneous restrike device should be adopted on the HID lamp. And also, the scheme of extending a setting time of relay on the undervoltage relay and the forming method of sequence which is automatic reclosing at this time of instantaneous suspension of an electric supply have been studied.

  • PDF

A Forward Speed Control of Head-feed Combine Using Continuously Variable V-belt Transmission -Combine Load Characteristics- (V-벨트 무단변속기(無斷變速機)를 이용(利用)한 자탈형(自脫型) 콤바인의 주행속도(走行速度) 제어(制御)(I))

  • Choi, K.H.;Ryu, K.H.;Cho, Y.K.;Park, P.K.
    • Journal of Biosystems Engineering
    • /
    • v.16 no.2
    • /
    • pp.124-132
    • /
    • 1991
  • This study was carried out to obtain the information needed in the development of forward speed control system and the improvement of combine performance. The effects of variety, grain moisture content and forward speed on the combine load characteristics were investigated through experiments. The results of this study are summarized as follows. 1. A data acquisition system was developed to measure the engine speed and the torques and speeds of the threshing cylinder, dean-grain auger and tailings-return auger. The system consisted of transducers, signal conditioner, interface board and microcomputer. The system accuracy is better than ${\pm}2.3%$ full scale. 2. Linear regression equations were obtained for the torque, speed and power requirement of threshing cylinder for different paddy varieties, grain moisture contents and feed rates. 3. The maximum value of relative frequency for threshing cylinder torque decreased as the increase in feed rate and moisture content. The range of torque fluctuation was 1.2~3.7 and 1.2~1.9 times the average and maximum torque, respectively. The maximum value of power spectrum density (PSD) appeared to be about 11 Hz regardless of paddy variety, grain moisture content and feed rate. 4. The speed of tailings return thrower decreased rapidly at below 900rpm, and it fell to near zero about 3 seconds after that time. When the travelling of combine harvester was stopped immediately after sensing the overload, it took about 7 seconds for a full recovery of the no-load speed of tailings return thrower.

  • PDF

Pathophysiology of orthostatic tremor: a multiple case study (길입성 진전의 병태생리: 다증 증례 연구)

  • Seo, Man-Wook;Lee, Kwang-Woo
    • Annals of Clinical Neurophysiology
    • /
    • v.4 no.1
    • /
    • pp.44-50
    • /
    • 2002
  • Introduction : Orthostatic tremor develops in the legs while standing up with no weakness, pain or imbalance in the leg and the tremor is characteristically not observed when walking. However there have been some confusions about orthostatic tremor in several aspects. For the past ten years, we have observed 4 patients with orthostatic tremor. In each case tests were performed to investigate the following three important areas of inquiry about orthostatic tremor. Firstly, whether this disorder is an independent diagnostic entity or a variant of essential tremor. Secondly, whether the progress of this disorder is specifically related with standing posture. Lastly, the nature of the pathophysiologic mechanism behind the appearance of the tremor when standing after the lapse of a certain latent period and its disappearance upon the commencement of walking. Methods : Our 4 cases of orthostatic tremor were studied clinically, electrophysiologically, and pharmacologically. Electrophysiological tests included tremor spectrum test and electromyography. Results : We observed the presence of this tremor in several other tonic postures, as well as its absence, in a vertically lifted position from all our cases. Our cases registered a variable tremor frequency between 5 and 12 Hz according to the tremor spectrum test and EMG. Furthermore all our 4 cases demonstrated patterns of both synchronous EMG activity and alternating EMG activity at various times in homologous muscles of both legs. Orthostatic tremor was improved significantly with propranolol as well as clonazepam. Conclusions : From the results of our study we drew the following conclusions. It is probable that orthostatic tremor is simply a variant of essential tremor rather than being an independent diagnostic entity and that in most cases its development is specifically related with muscle contraction rather than merely with the act of standing. Furthermore we discovered a clue in the previously described neural control mechanism that the nuclear bag fibers in the muscle spindle have lag time of several seconds in their response to muscle strength and that their baseline does not reset fully in rapidly moving muscle. This neural control mechanism could offer sufficient explanation for the phenomena of tremor appearance when standing and disappearance when walking in orthostatic tremor.

  • PDF

Efficient Harmonic-CELP Based Low Bit Rate Speech Coder (효율적인 하모닉-CELP 구조를 갖는 저 전송률 음성 부호화기)

  • 최용수;김경민;윤대희
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.5
    • /
    • pp.35-47
    • /
    • 2001
  • This paper describes an efficient harmonic-CELP speech coder by taking advantages of harmonic and CELP coders into account. According to frame voicing decision, the proposed harmonic-CELP coder adopts the RP-VSELP coder as a fast CELP in case of an unvoiced frame, or an improved harmonic coder in case of a voiced frame. The proposed coder has main features as follows: simple pitch detection, fast harmonic estimation, variable dimension harmonic vector quantization, perceptual weighting reflecting frequency resolution, fast harmonic synthesis, naturalness control using band voicing, and multi-mode. These features make the proposed coder require very low complexity, compared with HVXC coder To demonstrate the performance of the proposed coder, a 2.4 kbps coder has been implemented and compared with reference coders. From results of informal listening tests, the proposed coder showed good quality while requiring low delay and complexity.

  • PDF

Design of Stiffeners for Reducing Resonant Vibration of Large Vertical Pumps and Its Performance Verification (대형 입형펌프 운전 중 공진현상의 진동 저감을 위한 스티프너 설계 및 성능 검증)

  • Ryu, Kil-Su;Bong, Suk-Keun;Han, Seung-Woo;Roh, Cheol-Woo;Lee, Dong-Min;Lee, Jung-Woo;Park, Junhong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.1
    • /
    • pp.65-72
    • /
    • 2013
  • This case study presents a practical method to reduce resonant vibration of large vertical pumps. The pumps are driven at 400 rpm rated speed by induction motor. The vibration was not significantly large when operated at this rated speed. Large vibration was occurred when the pump was operated below the rated speed for flow control. Due to the large vibration resonance, variable speed operation of the pump was not possible for several months at worst cases. To find an efficient vibration control method, the flexural responses of pumps for both normal and transient operations were measured. The measured modal characteristics were compared with those of finite element analysis. When the pump was operated at a specific rpm, the natural mode whose resonance frequency is twice the rotating angular speed induced the large vibration. The retrofit utilizing stiffeners to reduce this resonant vibration were performed. Effects of designed stiffeners on reducing vibration were validated through tests after actual installation.