• 제목/요약/키워드: Variable compressor

검색결과 161건 처리시간 0.024초

가변속 열펌프의 냉매 유량제어에 의한 난방성능 변화에 관한 실험적 연구 (An Experimental Investigation on the Variation of Heating Performance Due to the Refrigerant Flow Control in a Variable-Speed Heat Pump)

  • 김봉훈
    • 설비공학논문집
    • /
    • 제13권8호
    • /
    • pp.746-756
    • /
    • 2001
  • An experimental study was conducted to investigated the effect of refrigerant flow control on the performance of a variable-speed heat pump operating in both cooling and heating mode. For this purpose, cooling and heating capacity, EER and refrigerant mass flow rate corresponding to an electronic valve as well as a capillary tube were measured as functions of compressor speed, length of capillary tube (or valve opening of the electronic valve), refrigerant charge, and outdoor temperature. From the comparison of experimental results, it was found that the performance variation due to the electronic valve opening became significant as the operating conditions(outdoor temperature and compressor speed) deviated from the standard condition at which heating capacity and EER were rated for the indicated capillary tube.

  • PDF

변속실외기펜을 사용한 텐텀형냉방기의 과열도제어에 관한 연구 (A Study on the Superheat Control of a Tandem-type Airconditioner by Using a Variable Speed Outdoor Fan)

  • 김재현;한도영
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.474-479
    • /
    • 2005
  • For the safe operation of an air conditioner, the liquid car η 'over to compressors should be minimized and compressors should be operated in the specified region of suction and discharge pressures recommended by compressor manufactures. In this study, a capillary assisted tandem-type airconditioner was considered. A variable speed outdoor fan was used to control operating points of the system. Test results showed the possibilities to move system operating points to the safe region by controlling the speed of an outdoor fan.

  • PDF

가변 사판식 압축기의 탑 클리어런스 측정 방법 및 신뢰성 확보에 관한 연구 (Study on the Measuring Method and Reliability of Top Clearance of Variable Swashplate Type Compressor)

  • 김영신;나승규
    • 설비공학논문집
    • /
    • 제28권3호
    • /
    • pp.89-94
    • /
    • 2016
  • In this experimental study, the effects of top clearance on the performance of automotive a/c compressor were studied. Top clearance measuring device was also developed to ensure the reliability using vacuum conditions to secure constant control of top clearance without external environmental influence. Our results revealed that the improvements in compressor performance according to different top clearance values using the same compressor and same operator were about 4.12% at 800 rpm and about 7.8% at 2,000 rpm in 0.243~0.252 mm of top clearance compared to 0.431~0.456 mm of top clearance. To confirm the consistency in measuring top clearance affecting compressor performance, the top clearance measuring device was developed in this study using a vacuum pump. After performing reliable tests repeatedly, the distribution of measuring values under this device was within 0.99~1.83%, indicating that the constant test data in compressor performance was not affected by any other external environment.

가변 입구 안내익이 있는 축류압축기의 성능예측 방법에 관한 연구 (A Study on the Performance Prediction Method for an Axial Compressor with Variable Inlet Guide Vane)

  • 김동현;김상조;김귀순;손창민;김유일;민성기
    • 한국추진공학회지
    • /
    • 제16권4호
    • /
    • pp.1-8
    • /
    • 2012
  • 본 연구에서는 가변 입구 안내익이 있는 다단 축류압축기의 성능예측을 위하여 3차원 전산해석, 전산해석 결과를 이용한 단 축적법, 그리고 스케일 된 단 축적법의 3가지 해석 기법을 적용하였다. 이 방법들을 적용하여 구한 압축기 탈설계점 성능특성은 성능시험 결과와 비교하여 분석하였으며, 가변 입구 안내익 적용시의 성능해석을 수행하여 가변 효과를 살펴보았다. 성능해석은 상용 전산 유동해석 프로그램인 FLUENT $6.3^{TM}$ 과 NASA의 압축기 해석 코드를 이용하여 해석을 수행하였다.

Analysis on Harmonic Loss of IPMSM for the Variable DC-link Voltage through the FEM-Control Coupled Analysis

  • Park, Hyun Soo;Jeung, Tae Chul;Lee, Jae Kwang;Lee, Byoung Kuk
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권1호
    • /
    • pp.225-229
    • /
    • 2017
  • This paper describes the loss analysis based on load conditions of the air conditioning compressor motors using variable dc-link voltage. The losses of PMSM (Permanent Magnet Synchronous Motor) should be analyzed by the PWM (Pulse Width Modulation) output of inverter. The harmonic loss by the PWM cannot consider that using the current source analysis of the inverter. In addition, when the voltage of dc-link is variable with the condition of variable speed and load conditions in motor, the losses of motor are also changeable, however it is hard to analyze those losses by only electromagnetic finite element method (FEM). Therefore, this paper proposes the analysis method considering the carrier frequency of the inverter and the varying state of the dc-link voltage through the FEM-control coupled analysis. Using proposed analysis method, additional core loss and eddy current loss of permanent magnet caused by PWM could be analyzed. Finally, the validity of the proposed analysis method is verified through the comparison the result of coupled analysis with experiment.

용량 가변 및 유량변화에 따른 지열원 물대물 열펌프 유닛의 충전량 변화에 따른 성능 특성 (Influence of Refrigerant Charge Amount on the Performance of a Water-to-Water Type Ground Source Heat Pump with a Variation of Compressor Speed and Water Flow Rate)

  • 조찬용;최종민
    • 신재생에너지
    • /
    • 제7권4호
    • /
    • pp.30-36
    • /
    • 2011
  • The objective of this study is to investigate the effects of the refrigerant charge amount on the performance of a water-to-water ground source heat pump with a variation of compressor speed and the secondary fluid flow rate. The water-to-water ground source heat pump was tested by varying refrigerant charge amount from -40% to 20% of full charge. Compressor speed was changed from 30 Hz to 75 Hz and the secondary fluid flow rate was adjusted from 6 LPM to 14 LPM. For all test conditions, EWTs of an indoor heat exchanger and an outdoor heat exchanger were maintained at standard conditions of ISO 13256-2. The slope of the COP with the variation of charge amount is much steeper at undercharged conditions than that at overcharged conditions. For all compressor speed, the variation of the system performance according to charge amounts showed the similar trends. However, the optimum charge amount of the system increased a little with an increment of compressor speed. When the secondary fluid flow rate decreased, the system was optimized at higher refrigerant charge amount conditions.

직접 구동방식 터보 압축기를 위한 통합 제어기 개발 (Development of An Integrated Controller for a Direct Drive Turbo Compressor)

  • 권정혁;변지섭;최중경
    • 전자공학회논문지SC
    • /
    • 제40권4호
    • /
    • pp.225-234
    • /
    • 2003
  • 터보 압축기는 구조적으로 임펠러를 고속회전 시켜야한다. 범용전동기에 높은 기어비를 가진 기어박스를 이용하여 구현하였는데, 이는 관성 모멘트, 마찰손 및 압축기의 크기를 증가시켰다. 최근 터보 압축기의 연구는 초고속 동기전동기를 장착하고 있고 기어박스를 제거하여 크기와 마찰손을 최소화하는 방향으로 진행되고 있다. 본 연구에서는 150마력 70,000rpm 직접 구동방식의 터보 압축기를 개발하기 위하여 초고속 동기전동기용 인버터제어기, 공압제어기 및 MMI 기능을 통합한 단일 DSP(Digital Signal Processor) 구조의 통합제어기를 구현하였다. 이는 하드웨어적인 부분만 아니라 소프트웨어적인 측면에서도 역시 통합 작업이 필요하였다. 이러한 통합으로 하드웨어적으로는 제어 시스템이 간략화 되었으며, 소프트웨어적으로도 동일한 개발환경에서 각 제어기가 구현되고 통합되었다. 이를 개발 및 제작하여 150마력 70,000rpm 직접 구동 방식의 터보 압축기에 적용하였다.

DSP를 이용한 직접 구동방식의 터보 압축기용 통합 제어기 개발 (The Development of DSP Based Multi Controller for Direct Drive Method Turbo Compressor)

  • 권정혁;변지섭;최중경;류한성
    • 한국정보통신학회논문지
    • /
    • 제6권6호
    • /
    • pp.885-890
    • /
    • 2002
  • 터보 압축기는 구조적으로 임펠러를 고속회전 시켜야 한다. 범용전동기에 높은 기어비를 가진 기어박스를 이용하여 구현하였는데, 이는 관성 모멘트, 마찰손 및 압축기의 크기를 증가시켰다. 최근에 터보 압축기의 연구는 초고속 동기전동기를 장착하여 기어박스를 제거하여 크기와 마찰손을 최소화하는 방향으로 진행되고 있다. 본 연구에서는 150마력 70,000rpm 직접 구동방식의 터보 압축기를 개발하기 위하여 초고속 동기전동기용 인버터제어기, 공압제어기 및 MMI 기능을 통합한 단일 DSP에 근거한 통합제어기를 구현하였다. 이는 하드웨어적인 부분만 아니라 소프트웨어적인 측면에서도 통합 작업이 필요하였다. 이러한 소프트웨어 및 하드웨어 통합을 통하여 하드웨어적으로는 제어 시스템을 간략화 되었으며, 소프트웨어적으로는 동일한 개발환경에서 각 종 제어기가 구현되고 통합되었다. 이를 개발 및 제작하여 150마력70,000rpm 직접 구동방식의 터보 압축기에 적응하였다