• 제목/요약/키워드: Variable Diffuser

검색결과 24건 처리시간 0.229초

가변 디퓨저를 장착한 원심 압축기 불안정성 연구 (A Study on the Instabilities of the Centrifugal Compressor with Variable Diffuser)

  • 차봉준;임병준;양수석
    • 대한기계학회논문집B
    • /
    • 제26권8호
    • /
    • pp.1123-1131
    • /
    • 2002
  • An experimental study on the performance and instability development characteristics of a centrifugal compressor equipped with a cambered variable diffuser has been performed with varying diffuser vane angles. The test was conducted at the design speed of 20,800 rpm and the 80% design speed of 16,640 rpm for 5 diffuser angles : 65$^{\circ}$, 70$^{\circ}$, 75$^{\circ}$, 77.5$^{\circ}$, 80$^{\circ}$ The steady performance test results showed that choking mass flow rate decreases and total pressure ratio increases with a narrowed surge margin as the diffuser vane angle increases. Unsteady pressures were measured using high-frequency pressure transducers at the inducer and the diffuser throat to investigate the instability phenomena such as rotating stall and surge inside the compressor. From the unsteady measurements, it is found that the transient process from rotating stall to surge was mainly affected by diffuser angles. The results of the present study can be applied to the instability control of the centrifugal compressors using a variable diffuser.

Air-Water Two-Phase Flow Performances of Centrifugal Pump with Movable Bladed Impeller and Effects of Installing Diffuser Vanes

  • Sato, Shinji;Furukawa, Akinori
    • International Journal of Fluid Machinery and Systems
    • /
    • 제3권3호
    • /
    • pp.245-252
    • /
    • 2010
  • It's known that pump head of centrifugal impeller with lager blade outlet angle is kept higher in air-water two phase flow condition, though the efficiency in water single phase flow condition is inferior. In the present study, a centrifugal impeller with variable blade outlet angles, that has higher efficiencies in both water single phase flow and air-water two phase flow conditions, is proposed. And the performances of the centrifugal impeller with variable blade outlet angles were experimentally investigated in both flow conditions of single and two-phase. In addition, effects of installing diffuser vanes on the performances of centrifugal pump with movable bladed impeller were also examined. The results are as follows: (1) The movable bladed impeller that proposed in this study is effective for higher efficiency in both water single phase and air-water two phase flow conditions. (2) When diffuser vanes are installed, the efficiency of movable bladed impeller decreases particularly at large water flow rate in water single-phase flow condition; (3) The performances of movable bladed impeller are improved by installing of diffuser vanes in air-water two-phase flow condition at relatively small water rate. The improvement by installing of diffuser vanes however disappears at large water flow rate.

극초음속 추진기관 고공환경 시험장치의 이차목 디퓨저 수축비에 따른 성능연구 (Performance Study on the Supersonic Diffuser Contraction Ratio of High-Altitude Test Facility for Hypersonic Propulsion)

  • 이성민;신동해;신민규;고영성;김선진;이정민
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2017년도 제48회 춘계학술대회논문집
    • /
    • pp.1026-1030
    • /
    • 2017
  • 본 연구에서는 극초음속 추진기관을 위한 시험설비의 장치인 초음속 디퓨저 설계하였고, 두 가지 수축비를 변수로 선정하여 각각의 디퓨저를 수치해석 및 상온 시험을 진행하였다. 수치해석을 통하여 각각의 마하수와 압력에 대한 내부 유동을 확인하였다. 상온 시험을 통하여 진공챔버에 형성되는 압력과 벽면 압력을 통하여 내부에 형성되는 압력을 확인할 수 있었다. 상온 시험과 수치해석의 차이점을 분석하고, 향후 극초음속 추진기관을 위한 시험설비를 구축할 기초자료를 확보하였다.

  • PDF

고마력 터보 블로어의 최적 깃배치각에 관한 수치 예측 (NUMERICAL PREDICTION OF THE OPTIMAL STAGGER ANGLES FOR A HIGH-POWER TURBO BLOWER)

  • 박태규;정희택;박준영;성병일
    • 한국전산유체공학회지
    • /
    • 제16권3호
    • /
    • pp.75-81
    • /
    • 2011
  • The turbo blowers having large power capacity are generally composed of the variable inlet guide vane, the impeller and the variable diffuser. In the present study, the effect of the stagger angles on the aerodynamic performances has been investigated by CFD methods. The design specifications of the reference model having 400kW power were given as 7.43kg/s of mass flow rate, 1.66 of pressure ratio with 12000rpm of impeller rotating speed. As the first simulation parameter, the diffuser vane angle was varied in the range of ${\pm}$20 degree from the initial-design point. The inlet guide vane angles, as the second one, was changed in the range of ${\pm}$40 degree from the initial-design point. The commercial Navier-Stokes solver, ANSYS-CFX, was applied to solve the three-dimensional unsteady flow fields inside the turbo blower. Through the numerical results, the desirable setting angles were proposed to fit the best performance to the variation of the operating conditions.

취출구를 가진 덕트의 공기분배장치 설계 (Design Of Air-Distribution System in a Duct)

  • 강형선;조병기;고영하
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권8호
    • /
    • pp.954-960
    • /
    • 2007
  • The purpose of this paper is to obtain design method of air-distribution system. Air-distribution system is composed of blower, duct, diffusers and measuring equipment. The air-flow rate from each diffuser is not equal. The air-flow rate is calculated with the combined equations which are Bernoulli's equation, continuity equation and minor loss equations. Inlet condition and outlet condition are adapted in each duct system. Then square difference between function of maximum air-flow rate and minimum air-flow rate is used as an object function. Area of diffuser and velocity are established as constraints. To minimize the object function, the optimization method is used. After optimization the design variables are selected under satisfaction of constraints. The air-distribution system is calculated again with the result of optimized design variable. It is shown that the air-distribution system has the equal air-flow rate from diffusers.

PIV를 이용한 디퓨저펌프 정익에서의 성능과 유동특성에 관한 연구 (A Study on Flow Characteristics and Efficiency in Guide Vane of Diffuser Pump Using PIV Measurement)

  • 김정환;김범석;김진구;함승덕;이영호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제27권5호
    • /
    • pp.633-640
    • /
    • 2003
  • The present experimental study is focused on the application of multi-point simultaneous measurement by PIV(Particle Image Velocimetry) to guide vane region within diffuser pump. Various different kinds of rotational velocity were selected as experimental condition. Optimized cross correlation Identification to obtain velocity vectors is implemented with direct calculation of correlation coefficients. Fine optical setup concerned with PIV performance is arranged for the accurate PIV measurement of high-speed complex flow. Variable flow pattern are represented quantitatively at the stator region.

PIV 계측을 이용한 디퓨져펌프의 정익에서의 성능과 유동특성에 관한 연구 (A Study on Flow and Efficiency Characteristics in Guide Vane of Diffuser Pump Using PIV Measurement)

  • 김정환;최민선;김진구;이영호
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2000년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.29-35
    • /
    • 2000
  • The present experimental study is focused on the application of multi-point simultaneous measurement by PIV(Particle Image Velocimetry) to guide vane region within diffuser pump. Various different kinds of rotational velocity were selected as experimental condition. Optimized cross correlation identification to obtain velocity vectors is implemented with direct calculation of correlation coefficients. Fine optical setup concerned with PIV performance is arranged for the accurate PIV measurement of high-speed complex flow. Variable flow pattern are represented quantitatively at the stator region.

  • PDF

고해상도 CCD 카메라를 이용한 디퓨져펌프 내부 유동특성에 대한 PIV 계측 (A PIV Measurement on Flow Characteristics inner Diffuser Pump Using High Resolution CCD Camera)

  • 김성윤;김범석;김정환;김유택;이영호
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2002년도 춘계학술대회논문집
    • /
    • pp.161-166
    • /
    • 2002
  • The resent experimental study is focused on the application of multi-point simultaneous measurement by PIV Particle Image Velocimetry) to guide vane region within diffuser pump. Various different kinds of rotational veto ity and changing clearance between Guide Vane and Impeller were selected as experimental condition. Optimized ross correlation identification to obtain velocity vectors is implemented with direct calculation of correlation coeffi cients. Fine optical setup concerned with PW performance is arranged for the accurate PW measurement of high peed complex flow. Variable flow pattern are represented quantitatively at the stator region.

  • PDF

냉난방 온도감지 디퓨져의 간극변화에 따른 기류분포 특성 (Air Distribution Performance According to the Gap Opening of a Temperature Controlled Diffuser)

  • 한화택;신민우;염철민;최선호
    • 설비공학논문집
    • /
    • 제18권2호
    • /
    • pp.180-185
    • /
    • 2006
  • This study has been conducted in order to develop a temperature-controlled round pan diffuser with variable-openings. Flow visualization was performed to investigate the airflow patterns according to gap openings. The velocity profiles were measured using an omni-directional anemometer for two cases, i.e. a horizontal and a vertical discharge conditions. Numerical simulation also confirms there is a narrow range of gap openings where a horizontal discharge shifts to a vertical discharge. The air distribution performance index increases abruptly when the air discharge shifts from vertical to horizontal direction.

중형버스 다출구 덕트의 최적설계에 관한 해석적 고찰 (A Numerical Analysis on the Optimum Design of a Duct with Multiple Outlets in a Medium Bus)

  • 김민호;천인범;이대훈
    • 한국자동차공학회논문집
    • /
    • 제10권4호
    • /
    • pp.223-233
    • /
    • 2002
  • The air distribution duct with multiple outlets is an essential part of automotive air-conditioning system In a bus. The estimation of airflow rate in an automotive air-conditioning duct is typically very complicate due to large variations in cross-sectional area and abrupt changes in flow direction, as well as unbalanced distribution of the flow. In this paper, the flow characteristic in a duct with multiple outlets is investigated through experiment, CFD simulation and a one-dimensional simulation. Numerical simulations have been performed for two simplified air conditioning ducts with multiple outlets used in a medium bus. The three dimensional Navier-Stokes code was used to evaluate the overall pressure, velocity Held, and distribution rate at each diffuser according to the change of various design parameters such as ratio of cross-sectional area and radius of bifurcated region. In addition, a one-dimensional program based on Bernoulli equation was developed to obtain optimized diffuser area required to equalize discharge flow rate at each outlet. As a result of this study, optimized diffuser area of design variable by one-dimensional program was very reasonable as compared to the trend deduced from CFD Simulation. Therefore, the simple and convenient one-dimensional analysis developed in this study can be applied in practical design procedure for air-conditioning duct.