• 제목/요약/키워드: Variable Constant Current

검색결과 133건 처리시간 0.025초

Simulations of Effects of Variable Conductance Throttle Valve on the Characteristics of High Vacuum System

  • Kim, Hyung-Taek;Cho, Han-Ho
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제7권2호
    • /
    • pp.28-35
    • /
    • 2015
  • Thin film electronic devices which brought the current mobile environment could be fabricated only under the high quality vacuum conditions provided by high vacuum systems. Especially for the development of advanced thin film devices, constant high quality vacuum as the deposition pressure is definitely needed. For this purpose, the variable conductance throttle valves were employed to the high vacuum system. In this study, the effects of throttle valve applications on vacuum characteristics were simulated to obtain the optimum design modelling of variable conductance of high vacuum system. Commercial simulator of vacuum system, $VacSim^{(multi)}$, was used on this investigation. Reliability of employed simulator was verified by the simulation of the commercially available models of high vacuum system. Simulated vacuum characteristics of the proposed modelling were agreed with the observed experimental behaviour of real systems. Pressure limit valve and normally on-off control valve were schematized as the modelling of throttle valve for the constant process-pressure of below $10^{-3}torr$. Simulation results were plotted as pump down curve of chamber, variable valve conductance and conductance logic of throttle valve. Simulated behaviors showed the applications of throttle valve sustained the process-pressure constantly, stably, and reliably.

가변이득을 가지는 디지털제어 단상 역률보상회로 (Single-Phase Power Factor Correction(PFC) Converter Using the Variable gain)

  • 백주원;신병철;정창용;이영운;유동욱;김홍근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.240-243
    • /
    • 2001
  • This paper presents the digital controller using variable gain for single-phase power factor correction (PFC) converter. Generally, the gain of inner current control loop in single-stage PFC converter has a constant magnitude. This is why input current is distorted under low input voltage. In particular, a digital controller has more time delay than an analog controller which degrades characteristics of control loop. So, it causes the problem that the gain of current control loop isn't increased enough. In addition, the oscillation happens in the peak value of the input voltage open loop PFC system gain changes according to ac input voltage. These aspects make the design of the digital PFC controller difficult. In this paper, the improved digital control method for single-phase power factor converter is presented. The variable gain according to input voltage and input current help to improve current shape. The 800W converter is manufactured to verify the proposed control method.

  • PDF

유도전동기(誘導電動機) 구동(驅動)을 위한 부하전류식(負荷轉流式) 전류형(電流型) 인버터의 제어(制御) (The Control of load Commutated Current Source Inverter for Induction Motor Drive)

  • 정연택;심재명;이사영;소용철;이재옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.255-257
    • /
    • 1994
  • The V/F slip frequency constant control methods are used for driving induction motor with load commutated current source inverter, that is. constant V/F and slip frequency driving is used to load commutate the inverter below the critical frequency, while constant voltage and variable frequency and slip frequency driving are used in above the critical region. In order to applicate the load commutated current source inverter to the general use, speed control range of induction noter is selected to two times at rated frequency. Therefore, economical application is possible because of the maximum reduction of the condenser of the inverter output port. The use of the proposed force commutated circuit improves the false operation of force commutated circuit and inverter commutation failure which are produced by the influence of the lower-order harmonics of the conventional load commutated current source inverter at starting.

  • PDF

직류 전동기의 저손실 구동을 위한 일정 주파수 제어형 영전압 스위칭 변환기의 구현 (Implement of Constant-Frequency-Controled Zero-Voltage-Switching Converter-fed DC Motor Drive for Low Power Loss)

  • 고문주;박진홍;한완옥;이성백
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.2148-2150
    • /
    • 1998
  • This paper proposes a constant frequency controlled zero voltage switching method that can reduce switching losses caused by emf on inductance in DC motor. The zero voltage switching method is used more than a zero current switching method because of reducing switching losses by capacitance of depletion region of MOSFET. To simplify the controller circuit, we propose constant frequency controlled zero voltage switching method in the paper. The control method is more stable than a variable frequency control method because it can optimize bandwidth of a closed-loop and reactances. Therefore, we construct a constant frequency controlled zero voltage switching converter and improve zero switching losses in high switching frequency. In the process, we can control low-losses in full range on variable voltage and load. We simulate the proposed converter with P-SPICE and compare results obtained through the experiment.

  • PDF

가변 출력 영전압 스위칭 PWM 컨버터에 관한 연구 (A study on ZVS-PWM Converter with Variable Output)

  • 김영재;임상언;김희준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.364-368
    • /
    • 1999
  • This paper suggests switching regulator technique to overcome the drawback of conventional variable linear power supply. Switching regulator technique can eliminate the extremely lossy operation and reduce the size and weight of variable linear power supply and provide nearly constant output power over the majority of output voltage range. The topology of variable switched mode power supply is employed active clamp forward converter with a current doubler rectifier and by using control of variable-frequency together with control of fixed-frequency, output voltage can be controled. Equivalent circuits pertinent to each operational mode of converter are derived, and an experimental 20V, 50A converter was designed and built. The converter operates from an output voltage of zero to 25 V, under 100 kHz switching frequency.

  • PDF

위상보상기를 가진 인버터로 구동되는 영구자석형 동기전동기의 제어기 설계 (The Controller Design of the Permanent Magnet Synchronous Drive Using a Inverter with Phase Compensator)

  • 유정웅;우광준
    • 대한전기학회논문지
    • /
    • 제37권3호
    • /
    • pp.146-154
    • /
    • 1988
  • The computer simulation of speed and phase control system has been carried out in this study. The load of permanent magnet type synchronous motor is not constant in this system. The cost function method has been used in obtaining the optimal gain of PI controller and the rotor position angle of phase controller has been compensated depending on the load and speed variation. This analysis also shows that the current of d-axis component is zero under the variable a load conditions and the torque per unit current can be maximized.

  • PDF

MRAS를 이용한 유도 전동기의 시정수 보상을 갖는 속도 센서리스 벡터제어 (Sensorless Vector Control System with Compensated Time Constant of Induction Motor Using a MRAS)

  • 임태윤;김동희;황돈하;김민회
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.540-543
    • /
    • 1999
  • This paper describes a speed sensorless algorithm for vector control system with compensated stator resistance and rotor time constant of induction motor using a model reference adaptive system(MRAS). The system are composed of two MRAC, one is a rotor speed estimation and a stator resistor identification by back-EMF observer, other is used to identify rotor time constant by magnetizing current observer, so that the estimation can be cover a very low speed range with a robust control. The suggest control strategy and estimation method have been validated by simulation study. In the simulation using Matlab/Simulik, the proposed speed sensorless vector control system are shown to operate very well in spite of variable rotor time constant and load fluctuation.

  • PDF

히스테리시스 제어기법을 이용한 태양광발전용 인버터 출력특성에 관한 연구 (A Study on the Characteristics of Solar Cell Inverter Using Hysteresis control Technique)

  • 임흥우;최연옥;김기범;백형래;조금배;김동휘
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.1296-1299
    • /
    • 2001
  • In this paper, a simple, novel approach is proposed for a variable hysterisis band current controller which uses feedback techniques to achieve constant switching frequency with good dynamic response. The simulation result shows constant switching frequency and consequenctly the load current ripple decrease.

  • PDF

메모리 소자의 DC parameter 검사회로 설계 (The Circuit Design for the DC Parameter Inspection of Memory Devices)

  • 김준식;주효남;전병준;이상신
    • 반도체디스플레이기술학회지
    • /
    • 제3권1호
    • /
    • pp.1-7
    • /
    • 2004
  • In this paper, we have developed the DC parameters test system which inspects the properties of DC parameters for semiconductor products. The developed system is interfaced by IBM-PC. It is consisted of CPLD part, ADC(Analog-to-Digital Converter), DAC(Digital-to-Analog Converter), voltage/current source, variable resistor and measurement part. In the proposed system, we have designed the constant voltage source and the constant current source in a part. In the comparison of results, the results of the simulation are very similar to the ones of the implementation.

  • PDF

Laser 프린터용 고압 가변 전원특성에 관한 연구 (A Study on the Characteristic of Variable High Voltage Power Source for Laser Printer)

  • 채영민;조종화;권중기
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.110-114
    • /
    • 2003
  • In this paper, a new self-oscillated type high voltage charger controller circuit is proposed, which has variable constant current source characteristics to improve charge characteristic of charger roller. The proposed control method enables high quality printing characteristics regardless of the circumstance change such as ambient temperature or humidity by changing the current reference signal. To verify the proposed control method various experiments are performed.

  • PDF