• 제목/요약/키워드: Variable Air Volume

검색결과 100건 처리시간 0.026초

실내오염물질의 환기기술전략에 따른 영향평가 : 수치적 모델을 이용한 HVAC 시스템의 비교연구 (The Impact of Ventilation Strategies on Indoor Air Pollution: A Comparative Study of HVAC Systems Using a Numerical Model)

  • Park, Sung-Woo;Song, Dong-Woong;D.J. Moschandreas
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제11권E호
    • /
    • pp.45-54
    • /
    • 1995
  • Indoor air quality models are useful to predict indoor air pollutant concentrations as a function of several indoor factors. Indoor air quality model was developed to evaluate the pollutant removal efficiency of variable-air-volume/bypass filtration system (VAV/BPFS) compared with the conventional variable-air-volume (VAV) system. This model provides relative pollutant removal effectiveness of VAV/BPFS by concentration ratio between the conventional VAV system and VAV/BPFS. The predictions agree closely, from 5 to 10 percent, with the measured values for each energy load. As a results, we recommend the VAV/BPFS is a promising alternative to conventional VAV system because it is capable of reducing indoor air pollutant concentration and maintaining good indoor air quality.

  • PDF

Numerical Simulation of Laminar Reacting Flows Using Unstructured Finite Volume Method With Adaptive Refinement

  • Kang, Sung-Mo;Kim, Hoo-Joong;Kim, Yong-Mo
    • 한국연소학회지
    • /
    • 제6권2호
    • /
    • pp.15-22
    • /
    • 2001
  • A pressure-based, unstructured finite volume method has been applied to couple the chemical kinetics and fluid dynamics and to capture effectively and accurately the steep gradient flame field. The pressure-velocity coupling is handled by two methodologies including the pressure-correction algorithm and the projection scheme. A stiff, operator-split projection scheme for the detailed nonequilibrium chemistry has been employed to treat the stiff reaction source terms. The conservative form of the governing equations are integrated over a cell-centered control volume with collocated storage for all transport variables. Computations using detailed chemistry and variable transport properties were performed for two laminar reacting flows: a counterflow hydrogen-air diffusion flame and a lifted methane-air triple flame. Numerical results favorably agree with measurements in terms of the detailed flame structure.

  • PDF

실내공기질 모델을 이용한 환기 시스템의 공기 정화 효율성 평가 (Evaluation of Ventilation System Performance Using Indoor Air Quality Model)

  • 최성우
    • 한국환경보건학회지
    • /
    • 제23권4호
    • /
    • pp.57-66
    • /
    • 1997
  • Successful energy conservation and good indcfor air quality (IAQ) are highly dependent on ventilation system. Air filtration is a primary solution of indoor air control strategies in terms of reducing energy consumption and improving ihdoor air quality. A conventional system with bypass filter, as it is called variable-air-volume/bypass filtration system (VAV/BPFS), is a variation of the conventional variable air volume (VAV) systems, which is designed to eliminate indoor air pollutant and to save energy. Bypass filtration system equipped with a high-efficiency particulate filter and carbon absorbent provides additional cleaned air into indoor environments and maintain good IAQ for human health. The objectives of this research were to compare the relative total decay rate of indoor air pollutant concentrations, and to develop a mathematical model simulating the performance of VAV/BPFS. All experiments were performed in chamber under the controlled conditions. The specific conclusions of this research are: 1. The VAV/BPFS system is more efficient than the VAV system in removing indoor air pollutant concentration. The total decay rates of aerosol, and total volatile organic compound (TVOC) for the VAV/BPFS system were higher than those of the conventional VAV system. 2. IAQ model predictions of each pollutant agree closely with the measured values. 3. According to IAQ model evaluation, reduction of outdoor supply air results in decreased dilution removal rate and on increased bypass filtration removal rate with the VAV/BPFS. As a results, we recommends the VAV/BPFS as an alternative to conventional VAV systems.

  • PDF

Research on the Variable Rate Spraying System Based on Canopy Volume Measurement

  • Hu, Kaiqun;Feng, Xin
    • Journal of Information Processing Systems
    • /
    • 제15권5호
    • /
    • pp.1131-1140
    • /
    • 2019
  • Characteristics of fruit tree canopies are important target information for adjusting the pesticide application rate in variable rate spraying in orchards. Therefore, the target detection of the canopy characteristics is very important. In this study, a canopy volume measurement method for peach trees was presented and a variable rate spraying system based on canopy volume measurement was developed using the ultrasonic sensing, one of the most effective target detection method. Ten ultrasonic sensors and two flow control units were mounted on the orchard air-assisted sprayer. The ultrasonic sensors were used to detect the canopy diameters and the flow controls were used to modify the flow rate of the nozzles in real time. Two treatments were established: a constant application rate of $300Lha^{-1}$ was set as the control treatment for the comparison with the variable rate application at a $0.095Lm^{-3}$ canopy. The tracer deposition at different parts of peach trees and the tracer losses to the ground (between rows and within rows) were analyzed in detail under constant rate and variable rate application. The results showed that there were no significant differences between two treatments in the liquid distribution and the capability to reach the inner parts of the crop canopies.

선박 HVAC 효율 증가를 위한 변풍량 방식 공기조화 연구 (VAV Air Conditioning Research for Ship HVAC Efficiency)

  • 강영민;김민욱;장재희;김희망;오진석
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2016년도 춘계학술대회
    • /
    • pp.93-95
    • /
    • 2016
  • 최근 물동량 하락으로 인해 선박의 에너지 절감에 대한 선주들의 관심이 모아지고 있다. 선박용 HVAC은 선박 구조상 거주구역이 수밀형 창문으로 구성되고 폐쇄적이기 때문에 승무원의 쾌적한 환경 조성을 위해 사용된다. 또한 생활수준의 향상과 더불어 승무원들의 쾌적함에 대한 요구는 더욱 강해지고 있어 HVAC의 기능 향상이 요구되고 있다. 따라서 본 논문에서는 변풍량 방식의 선박용 HVAC 구조를 사용하여 HVAC 제어기능 향상 및 에너지를 절감할 수 있는 방법을 제시한다.

  • PDF

Energy Auditing Using a Building Energy Simulation Program BLDSYM

  • Lee, E.J.;Yoon, J.H.;Kang, Y.H.;Jeon, H.S.
    • 태양에너지
    • /
    • 제15권3호
    • /
    • pp.53-58
    • /
    • 1995
  • The objectives of this study are to introduce the energy simulation program BLDSYM, to verify the approach, and to demonstrate the energy saving opportunities. A case study model for Hoover Middle School, OK, USA has been introduced as a base case simulation. Air-side variable air volume(VAV) and water-side variable flow hydronic(VFH) system have been recommended, modeled and simulated to quantify the energy savings compared with the base system, which is typically constant air and water flow system. More than 30% of energy savings could be obtained with the optimum variable flow system.

  • PDF

Energy Simulation for Energy Saving Opportunities

  • Lee, E.J.;J.H. Yoon;Y.H. Kang;H.S. Jeon
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1995년도 춘계학술발표회 초록집
    • /
    • pp.88-93
    • /
    • 1995
  • The purpose of this study is to introduce the energy simulation program BLDSYM, verify the approach. and demonstrate the energy saving opportunities. A case study model for Hoover Middle School, OK USA has been introduced as a base case simulation. Air-side variable air volume (VAV) and water-side variable flow hydronic (VFH) system have been recommended, modeled and simulated to quantify the energy savings compared with the base system, which is typically constant air and water flow system. More than 30 % of energy savings could be obtained with the optimum variable flow system.

  • PDF

변풍량 공조 시스템의 제어

  • 주영덕
    • 대한설비공학회지:설비저널
    • /
    • 제29권2호
    • /
    • pp.39-45
    • /
    • 2000
  • 1970년대부터 사용된 변풍량 공조 시스템 (Variable Air Volume System)은 실내 부하 변동에 따라 급기 온도를 일정하게 유지시키고 실별, 존별 송풍량을 변화시켜 실온을 제어하는 방식으로, 에너지 절약, 개별 제어 등의 장점 때문에 적용이 확대되었고 특히 단일덕트 변풍량 공조 시스템은 이러한 이유 때문에 많은 건물에 적용되고 있다. 그러나 현 제어시스댐의 풍량 측정의 문제점과 공조기내에서 풍량변화 및 급/배기 댐퍼의 개도 변경으로 인한 환기 댐퍼의 비선형 특성을 고려하지 않고 제어하기 때문에 외기량 확보를 정확히 유지 못하는 실정이다. 따라서 단일덕트 변풍량 시스템의 환기댐퍼 및 급기, 환기 팬의 제어 방식의 종류와 특성 및 문제점에 대하여 설명하고자 한다.

  • PDF

공조 시스템의 고장진단을 위한 분류기술 연구 (Classification Methods for Fault Diagnosis of an Air Handling Unit)

  • 이원용;신동열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 B
    • /
    • pp.420-422
    • /
    • 1998
  • All Fault Detection and Diagnosis(FDD) methods utilize classification techniques. The objective of this study was to demonstrate the application of classification techniques to the problem of diagnosing faults in data generated by a variable-air-volume(VAV) air-handling unit(AHU) simulation model and to describe the characteristics of the techniques considered. Artificial neural network classifier and fuzzy clustering classifier were considered for fault diagnostics.

  • PDF