• Title/Summary/Keyword: Vapor pressure of water

Search Result 422, Processing Time 0.036 seconds

Analysis of Flow through High Pressure Bypass Valve in Power Plant (발전소용 고압 바이패스 밸브 내부 유동해석)

  • Cho, An-Tae;Kim, Kwang-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.10 no.6
    • /
    • pp.17-23
    • /
    • 2007
  • In the present work, flow analysis has been performed in the steam turbine bypass control valve (single-path type) for two different cases i.e., case with steam only and case with both steam and water. The numerical analysis is performed by solving three-dimensional Reynolds-averaged Navier-Stokes (RANS) equations. The shear stress transport (SST) model and $k-{\varepsilon}$ model are used to each different case as turbulence closure. Symmetry condition is applied at the mid plane of the valve while adiabatic condition is used at the outer wall of the cage. Grid independency test is performed to find the optimal number of grid points. The pressure and temperature distributions on the outer wall of the cage are analyzed. The mass flow rate at maximum plug opening condition is compared with the designed mass flow rate. The numerical analysis of multiphase mixing flow(liquid and vapor) is also performed to inspect liquid-vapor volume fraction of bypass valve. The result of volume fraction is useful to estimate both the safety and confidence of valve design.

Application of Si3N4 Thin Film as a Humidity Protection Layer for Organic Light Emitting Diode (Si3N4 박막의 유기발광소자 수분침투 방지막으로의 응용)

  • Kim, Chang-Jo;Shin, Paik-Kyun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.5
    • /
    • pp.397-402
    • /
    • 2010
  • In this paper, we studied WVTR(water vapor transmission rate) properties of $Si_3N_4$ thin film that was deposited using TCP-CVD (transformer coupled plasma chemical vapor deposition) method for the possibility of OLED(organic light emitting diode) encapsulation. Considering the conventional OLED processing temperature limit of below $80^{\circ}C$, the $Si_3N_4$ thin films were deposited at room temperature. The $Si_3N_4$ thin films were prepared with the process conditions: $SiH_4$ and $N_2$, as reactive gases; working pressure below 15 mTorr; RF power for TCP below 500 W. Through MOCON test for WVTR, we analyzed water vapor permeation per day. We obtained that WVTR property below 6~0.05 gm/$m^2$/day at process conditions. The best preparation condition for $Si_3N_4$ thin film to get the best WVTR property of 0.05 gm/$m^2$/day were $SiH_4:N_2$ gas flow rate of 10:200 sccm, working pressure of 10 mTorr, working distance of 70 mm, TCP power of 500 W and film thickness of 200 nm. respectively. The proposed results indicates that the $Si_3N_4$ thin film could replace metal or glass as encapsulation for flexible OLED.

Superhydrophobic nanostructured non-woven fabric using plasma modification

  • Shin, Bong-Su;Lee, Kwang-Reoul;Kim, Ho-Young;Moon, Myoung-Woon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.320-320
    • /
    • 2011
  • We describe fabrication of superhydrophobic surface on non-woven fabric (NWF) having nano-hairy structures and a hydrophobic surface coating. Oxygen plasma was irradiated on NWF for nano-texuring and a precursor of HMDSO (Hexamethydisiloxane) was introduced as a surface chemical modification for obtaining superhydrophobicity using 13.56 MHz radio frequency-Plasma Enhanced Chemical Vapor Deposition (rf-PECVD). O2 plasma treatment time was varied from 1 min to 60 min at a bias voltage of 400V, which fabricated pillar-like structures with diameter of 30 nm and height of 150 nm on NWF. Subsequently, hydrophobic coating using hexamethyldisiloxane vapor was deposited with 10 nm thickness on NWF substrate at a bias voltage of 400 V. We evaluate superhydrophobicity of the modified NWF with sessile drop using goniometer and high speed camera, in which aspect ratio of nanohairy structures, contact angle and contact angle hysteresis of the surfaces were measured. With the increase of aspect ratio, the wetting angle increased from $103^{\circ}$ to $163^{\circ}$, and the contact angle hysteresis decreased dramatically below $5^{\circ}$. In addition, we had conducted experiment for nucleation and condensation of water via E-SEM. During increasing vapor pressure inside E-SEM from 3.7 Torr to over 6 Torr which is beyond saturation point at $2^{\circ}C$, we observed condensation of water droplet on the superhydropobic NWF. While the condensation of water on oxygen plasma treated NWF (superhydrophilic) occurred easily and rapidly, superhydrophobic NWF which was fabricated by oxygen and HMDSO was hardly wet even under supersaturation condition. From the result of wetting experiment and water condensation via E-SEM, it is confirmed that superhydrophobic NWF shows the grate water repellent abilities.

  • PDF

Effects of Light, Temperature, Water Changes on Physiological Responses of Kalopanax pictus Leaves(II) - Characteristics of Stomatal Transpiration, Water Efficiency, Vapor Pressure Deficit of Leaves by the Light Intensity - (광, 온도, 수분 변화에 따른 음나무 엽의 생리반응(II) - 광도변화에 따른 기공증산, 수분이용효율, 수증기압결핍 -)

  • Han, Sang-Sup;Jeon, Doo-Sik;Sim, Joo-Suk
    • Journal of Forest and Environmental Science
    • /
    • v.21 no.1
    • /
    • pp.92-97
    • /
    • 2005
  • This research was carried out to elucidate the characteristics of stomatal transpiration, water efficiency, vapor pressure deficit of leaves by the light intensity Kalopanax pictus leaves. The results obtained are summarized as follows: 1. In the upper leaves of Kalopanax pictus seedlings, the stomatal transpiration rate increased continuously with increasing light intensity, but in the middle and lower leaves. it was saturated at $100{\mu}mol\;m^{-2}S^{-1}$. At the light saturated point. the stomatal transpiration rate was in the following order: the upper ($1.29mmol\;H_2O\;m^{-2}S^{-1}$) middle ($0.56mmol\;H_2O\;m^{-2}S^{-1}$) lower leaves ($0.31mmol\;H_2O\;m^{-2}S^{-1}$). 2. In the upper leaves, water use efficiency rapidly increased to $600{\mu}mol\;m^{-2}S^{-1}$, and then decreased. In the middle and lower leaves, it increased to $400{\mu}mmol\;m^{-2}S^{-1}$, and then showed a constant values. 3. The vapor pressure deficit (VPD) in according to leaf positions was linearly decreased with increasing photosynthetic photon flux density (PPFD).

  • PDF

Air Circulating Oven-drying Characteristics of Hollowed Round-post for Korean Main Conifer Species Part 3: Effects of Water-vapor Dam and Heartwood Coating Treatments

  • Lee, Nam-Ho;Zhao, Xue-Feng;Shin, Ik-Hyun;Lee, Chang-Jin
    • Journal of the Korean Wood Science and Technology
    • /
    • v.42 no.2
    • /
    • pp.101-111
    • /
    • 2014
  • In this study the effect of heartwood-coating (HCO), vapor-dam (VD), bark-remaining (BR) and bark-remaining-coating (BRC) treatments on the air circulating oven-drying characteristics of Japanese larch hollowed round-post was evaluated. The drying times of the hollowed round-posts for control, VD, HCO and BR specimens were 72, 168, 204 and 240 hours, respectively, from the initial MC to about 8% MC, which was recommended as the indoor in-use MC. The temperature in the hole of the VD specimen was lower than that of wood and the difference between air temperature in the hole and wood temperature became large during drying period. The vapor pressure of air in the hole was higher than that of inside wood for all specimens except VD specimen. The surface checks on all specimens were observed in increasing order of BR, BRC, UC, HCO and VD specimens.

Water Repellent Finish of Polyester Fabric Using Glow Discharge Treatment (글로우방전을 이용한 폴리에스테르 직물의 투습방수성 개질)

  • 김태년
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.25 no.1
    • /
    • pp.154-161
    • /
    • 2001
  • We have treated polyester fabric with $CF_4,\;C_2F_6,\;SF_6\;and\;C_3F_6$ glow discharge plasmas to develop functional fabrics which preserve moisture transportation and water proofing nature. Modified properties were evaluated by water vapor permeation rate and breakthrough water pressure. The change of surface morphology was observed by SEM. Fiber interstice of the plasma treated fabric was calculated as $0.32{\mu}{\textrm}{m}$, and this value was sufficiently ideal as water repellent material. The moisture transportation of ${CF_4}-treated$ fabric was good as much as untreated fabric, and those of $C_2$F(sub)6-treated, SF(sub)6-treated fabrics were reduced by 1~3%, and that of ${C_3F_6}-treated$ fabric was reduced by 15%. The best treatment condition were 0.06 torr 120 seconds in $CF_4$, 0.05 torr 30 seconds in $SF_6$, 0.08~0.15 torr 90 seconds in $SF_6$ and 0.1 torr 45 seconds in $C_3F_6$ respectively. The grade of moisture transportation effect was $CF_4>C_2F_6>SF_6>>C_3F_6$, and water proofing effect was $C_2F_6{\approx}CF_4>C_3F_6>SF_6$. It was observed by SEM that the thin film was formed on the surface of the treated substrate by the fluorocarbon plasma treatment.

  • PDF

Development of Turbopump Cavitation Performance Test Facility and the Test of Inducer Performance (터보펌프 Cavitation 성능시험기 개발 및 성능시험에 관한 연구)

  • Sohn, Dong-Kee;Kim, Chun-Tak;Yoon, Min-Soo;Cha, Bong-Jun;Kim, Jin-Han;Yang, Soo-Seok
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.619-624
    • /
    • 2001
  • A performance test facility for turbopump inducer cavitation was developed and the inducer cavitation performance tests were performed. Major components of the performance test facility are driving unit, test section, piping, water tank, and data acquisition and control system. The maximum of testing capability of this facility are as follows: flow rate - 30kg/s; pressure - 13 bar; rotational speed 10,000rpm. This cavitation test facility is characterized by the booster pump installed at the outlet of the pump that extends the flow rate range, and by the pressure control system that makes the line pressure down to vapor pressure. The vacuum pump is used for removing the dissolved air in the water as well as the line pressure. Performance tests were carried out and preliminary data of test model inducer were obtained. The cavitation performance test and cavitation bubble flow visualization were also made. This facility is originally designed for turbopump inducer performance test and cavitation test. However it can be applied to the pump impeller performance test in the future with little modification.

  • PDF

The Moving Speed of Typhoons of Recent Years (2018-2020) and Changes in Total Precipitable Water Vapor Around the Korean Peninsula (최근(2018-2020) 태풍의 이동속도와 한반도 주변의 총가강수량 변화)

  • Kim, Hyo Jeong;Kim, Da Bin;Jeong, Ok Jin;Moon, Yun Seob
    • Journal of the Korean earth science society
    • /
    • v.42 no.3
    • /
    • pp.264-277
    • /
    • 2021
  • This study analyzed the relationship between the total precipitable water vapor in the atmosphere and the moving speed of recent typhoons. This study used ground observation data of air temperature, precipitation, and wind speed from the Korea Meteorological Administration (KMA) as well as total rainfall data and Red-Green-Blue (RGB) composite images from the U.S. Meteorological and Satellite Research Institute and the KMA's Cheollian Satellite 2A (GEO-KOMPSAT-2A). Using the typhoon location and moving speed data provided by the KMA, we compared the moving speeds of typhoon Bavi, Maysak, and Haishen from 2020, typhoon Tapah from 2019, and typhoon Kong-rey from 2018 with the average typhoon speed by latitude. Tapah and Kong-rey moved at average speed with changing latitude, while Bavi and Maysak showed a significant decrease in moving speed between approximately 25°N and 30°N. This is because a water vapor band in the atmosphere in front of these two typhoons induced frontogenesis and prevented their movement. In other words, when the water vapor band generated by the low-level jet causes frontogenesis in front of the moving typhoon, the high pressure area located between the site of frontogenesis and the typhoon develops further, inducing as a blocking effect. Together with the tropical night phenomenon, this slows the typhoon. Bavi and Maysak were accompanied by copious atmospheric water vapor; consequently, a water vapor band along the low-level jet induced frontogenesis. Then, the downdraft of the high pressure between the frontogenesis and the typhoon caused the tropical night phenomenon. Finally, strong winds and heavy rains occurred in succession once the typhoon landed.

A NEW PRESSURE GRADIENT RECONSTRUCTION METHOD FOR A SEMI-IMPLICIT TWO-PHASE FLOW SCHEME ON UNSTRUCTURED MESHES (비정렬 격자 기반의 물-기체 2상 유동해석기법에서의 압력기울기 재구성 방법)

  • Lee, H.D.;Jeong, J.J.;Cho, H.K.;Kwon, O.J.
    • Journal of computational fluids engineering
    • /
    • v.15 no.2
    • /
    • pp.86-94
    • /
    • 2010
  • A thermal-hydraulic code, named CUPID, has been developed for the analysis of transient two-phase flows in nuclear reactor components. A two-fluid three-field model was used for steam-water two-phase flows. To obtain numerical solutions, the finite volume method was applied over unstructured cell-centered meshes. In steam-water two-phase flows, a phase change, i.e., evaporation or condensation, results in a great change in the flow field because of substantial density difference between liquid and vapor phases. Thus, two-phase flows are very sensitive to the local pressure distribution that determines the phase change. This in turn puts emphasis on the accurate evaluation of local pressure gradient. This paper presents a new reconstruction method to evaluate the pressure gradient at cell centers on unstructured meshes. The results of the new scheme for a simple test function, a gravity-driven cavity, and a wall boiling two-phase flow are compared with those of the previous schemes in the CUPID code.

Study of the geometry of the flow path of a Pressure Reducing Valve to Suppress the Cavitations (캐비테이션 억제를 위한 감압밸브의 유로 형상에 관한 연구)

  • Park, Woo-Cheul;Kim, Il-Gyum
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.1
    • /
    • pp.50-55
    • /
    • 2015
  • This study examined the relationship between the shape of the inside of the PRV and the cavitation of the water supply system of an apartment house. In this paper, nine types of PRV with different gaps and shapes were analyzed numerically using a 3D model embedded in the commercial code, ANSYS-CFX. The lowest pressure and the maximum velocity occurred at the narrow gap, which is located at the between the stem and the disk. When the gap size was increased, the vapor volume fraction was always greater than 0, but the vapor volume fraction of the type of expansion pipe approached 0. These results indicate that the cavitation of PRV can be reduced by a shape change to the type of expansion pipe.