• 제목/요약/키워드: Vapor phase

검색결과 1,125건 처리시간 0.034초

Vapor Phase Lubrication을 통한 금속의 마찰 및 마멸 특성 (Characteristics of Friction and Wear of Metals Under Vapor Phase Lubrication)

  • 김대은;양지철;성인하
    • Tribology and Lubricants
    • /
    • 제18권2호
    • /
    • pp.109-116
    • /
    • 2002
  • phase lubrication can be used as an alterative lubrication method to overcome the demerits of liquid and solid lubrications. In this work, the tribological characteristics of metals are investigated under vapor phase lubrication. It was found that the friction coefficient and wear volume can be controlled efficiently by the amount of vapor phase lubricant delivered to the sliding interface. The friction coefficient could be reduced to about 0.1 under vapor lubrication. Also, depending on the amount of vapor lubrication delivered to the system, the width of the wear track could be varied between 50 to 250 Um. It is shown that vapor phase lubrication mechanism is very effective to control the friction and wear phenomena without the use of excessive oil.

증발 조건에서 직분식 가솔린 분무의 증기 농도의 분포 (Distribution of the Concentration of Fuel Vapor in DI Gasoline Sprays Under Evaporation Condition)

  • 황순철;최동석;차건종;김덕줄
    • 한국분무공학회지
    • /
    • 제4권4호
    • /
    • pp.1-8
    • /
    • 1999
  • The concentration and spatial distribution of vapor phases in DI (Direct Injection) gasoline spray were measured quantitatively by exciplex fluorescence method. Fluorobenzene and DEMA (diethylmethylamine) in a solution of hexane were used as the exciplex-forming dopants. The fluorescence intensity of vapor phase were obtained by ICCD camera with the appropriate filter The relationship between fluorescence intensity and vapor concentration was induced fer the purpose of a quantitative analysis. The 2-D vapor/liquid images of fuel spray were captured under the evaporation condition, and the spatial distribution of vapor concentration was obtained. The spatial distribution of liquid phase had hollow-cone shape. And the vapor phase was widely distributed in the whole spray. The behavior of vapor phase was significantly affected by second flow such as entrainment, vortex, while that of liquid phase was scarcely affected.

  • PDF

소형형광등(Compact Fluorescent Lamp)의 파쇄에 따른 기상에서의 수은농도 특성 (Characteristics of Mercury Concentration in Vapor Phase from Compact Fluorescent Lamp)

  • 이승희
    • Korean Chemical Engineering Research
    • /
    • 제52권5호
    • /
    • pp.652-656
    • /
    • 2014
  • 소형형광등(Compact fluorescent Lamp; CFL) 3종류를 파쇄할 때 발생하는 수은의 기상농도와 대기로 방출되는 수은 양을 평가하였다. CFL 파쇄 시 배출되는 수은 농도는 초기에 매우 급격하게 감소되었으나 24시간 이후에는 수은농도의 변화가 점차 작아졌으며, 이 후 42시간까지 일정 농도를 유지되었다. 이러한 일정한 농도를 안정화 농도(Stabilized concentration)로 나타내었고 안정화 농도는 기체상 수은이 거의 배출되어 파쇄장치에 잔류하는 액체상 수은이 온도와 기압에 의한 영향으로 기화되어 배출되는 것으로 판단되었다. 소형형광등에서 발생되는 수은농도는 회사별로 A사 < B사 < C사 순으로 나타났으며, 회사별로 수은의 안정화 농도와 안정화 시간은 A사 < B사 < C사 순으로 높았다. 공기유량이 증가함에 따라 수은 부분압은 감소하였으며, 이는 대기 중 수은의 양이 낮아짐을 의미하고 안정화 농도도 감소하는 것으로 나타났다. CFL 파쇄 시 초기의 수은 농도는 공기유량에 관계없이 $0.1mg/m^3$인 지정시설의 환경기준보다 매우 높으므로 소형형광등을 파쇄할 때 기상의 수은을 관리하는 것이 절대적으로 필요하다.

쉴리렌 가시화 기법을 이용한 E85 연료의 액상 및 기상 분무 비교 (Comparison of Liquid- and Vapor-Phase Spray Characteristics of E85 Fuel using Schlieren Visualization Technique)

  • 박수한;상몽소
    • 융복합기술연구소 논문집
    • /
    • 제8권1호
    • /
    • pp.9-13
    • /
    • 2018
  • The purpose of this study is to investigate the liquid- and vapor-phase spray characteristics, such as spray tip penetration and spray angle using gasoline direct injection (GDI) injector with multi-hole. The vapor-phase spray was captured by the Schlieren visualization system, which consists of high-speed camera, LED lamp, concave mirrors, and knife-edge. The liquid-phase spray was visualized by Mie-scattering techniques. Both spray images of vapor- and liquid-phase were visualized under 373 K of ambient temperature, 1 bar of ambient pressure, and 100/200 bar of injection pressure. The energizing duration was fixed at 1.5 ms. From the analysis of experimental results, it revealed that the increased injection pressure induced an early vaporization due to the improvement of droplet atomization. The spray tip penetration and spray angle in vapor-phase were higher than those in liquid-phase. The difference in the spray tip penetration between vapor- and liquid-spray gradually increased with the time elapsed after the injection. Even with the spray angle characteristics, it was found that the difference between the spray angle of liquid and vapor spray gradually grew after they entered steady-state conditions.

Effect of HF and Plasma Treated Glass Surface on Vapor Phase-Polymerized Poly(3,4-ethylenedioxythiophene) Thin Film : Part I

  • Lee, Joonwoo;Kim, Sungsoo
    • 통합자연과학논문집
    • /
    • 제6권4호
    • /
    • pp.211-214
    • /
    • 2013
  • In this study, in order to investigate how consecutive treatments of glass surface with HF acid and water vapor/Ar plasma affect the quality of 3-aminopropyltriethoxysilane self-assembled monolayer (APS-SAM), poly(3,4-ethylenedioxythiophene) (PEDOT) thin films were vapor phase-polymerized immediately after spin coating of FeCl3 and poly-urethane diol-mixed oxidant solution on the monolayer surfaces prepared at various treatment conditions. For the film characterization, various poweful tools were used, e.g., FE-SEM, an optical microscope, four point probe, and a contact angle analyzer. The characterization revealed that HF treatment is not desirable for the synthesis of a high quality PEDOT thin film via vapor phase polymerization method. Rather, sole treatment with plasma noticeably improved the quality of APS-SAM on glass surface. As a result, a highly dense and smooth PEDOT thin film was grown on uniform oxidant film-coated APS monolayer surface.

Expert System Approach for Vapor-Phase Infrared Spectra of Aromatic Compounds

  • Pyo Dongjin;Hwang Hoon;Lee Junyeoun
    • Bulletin of the Korean Chemical Society
    • /
    • 제13권2호
    • /
    • pp.148-155
    • /
    • 1992
  • Computerized interpretation of vapor phase infrared spectra using a novel expert system approach for spectra/structure correlation for vapor phase spectra is introduced. Rapid identification of aromatic functional groups of components in gaseous mixture can be achieved using this expert system.

Selective Vapor-Phase Deposition of Conductive Poly(3,4-ethylenedioxythiophene) Thin Films on Patterned FeCl3 Formed by Microcontact Printing

  • Lee, Bo H.;Cho, Yeon H.;Shin, Hyun-Jung;Kim, Jin-Yeol;Lee, Jae-gab;Lee, Hai-won ;Sung, Myung M.
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권10호
    • /
    • pp.1633-1637
    • /
    • 2006
  • We demonstrate a selective vapor-phase deposition of conductive poly(3,4-ethylenedioxythiophene) (PEDOT) thin films on patterned $FeCl_3$. The PEDOT thin films were grown on various substrates by using the vapor-phase polymerization of ethylenedioxythiophene (EDOT) with $FeCl_3$ catalytic layers at 325 K. The selective deposition of the PEDOT thin films using vapor-phase polymerization was accomplished with patterned $FeCl_3$ layers as templates. Microcontact printing was done to prepare patterned $FeCl_3$ on polyethyleneterephthalate (PET) substrates. The selective vapor-phase deposition is based on the fact that the PEDOT thin films are selectively deposited only on the regions exposing $FeCl_3$ of the PET substrates, because the EDOT monomer can be polymerized only in the presence of oxidants, such as $FeCl_3$, Fe($CIO_4$), and iron(II) salts of organic acids/inorganic acids containing organic radicals.

Effect of HF and Plasma Treated Glass Surface on Vapor Phase-Polymerized Poly(3,4-ethylenedioxythiophene) Thin Film : Part II

  • Lee, Joonwoo;Kim, Sungsoo
    • 통합자연과학논문집
    • /
    • 제6권4호
    • /
    • pp.215-219
    • /
    • 2013
  • In this study, in order to investigate how consecutive treatments of glass surface with HF acid and water vapor/Ar plasma affect the quality of 3-aminopropyltriethoxysilane self-assembled monolayer (APS-SAM), poly(3,4-ethylenedioxythiophene) (PEDOT) thin films were vapor phase-polymerized immediately after spin coating of FeCl3 and poly-urethane diol-mixed oxidant solution on the monolayer surfaces prepared at various treatment conditions. For the film characterization, various poweful tools were used, e.g., FE-SEM, an optical microscope, four point probe, and a contact angle analyzer. The characterization revealed that a well prepared APS-SAM on a glass surface treated with water vapor/Ar plasma is very useful for uniform coating of FeCl3 and DUDO mixed oxidant solution, regardless of HF treatment. On the other hand, a bare glass surface without APS-SAM but treated with HF and water vapor/Ar plasma generally led to a very poor oxidant film. As a result, PEDOT films vapor phase-polymerized on APS-SAM surfaces are far superior to those on bare glass surfaces in the quality and electrical characteristics aspects.

Atmospheric Concentrations of PAHs in the Vapor and Particulate Phases in Chongju

  • Park, Seung-Shik;Kim, Young-J.;Kang, Chang-H.;Cho, Sung-Yong;Kim, Tae-Young;Kim, Seung-Jai
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제22권E2호
    • /
    • pp.57-68
    • /
    • 2006
  • Four intensive seasonal sampling campaigns between October 1998 and October 1999 were undertaken at an urban site of Chongju, in which polyurethane foam (PUF) sampler was used to collect particulate- and vapor-phase polycyclic aromatic hydrocarbons (PAHs). The contribution to total (particulate+vapor) PAH concentration by the vapor phase component exceeded the particulate phase contribution by factor of ${\sim}2.6$. Summed concentrations of phenanthrene (30.9%), pyrene (16.6%), naphthalene (11.3%) and fluoranthene (11.0%) account for significant amounts of the vapor-phase, while chrysene (12.5%), benzo[b]fluoranthene (11.6%), indeno[123-cd]pyrene (9.9%), benzo[ghi]perylene (9.5%), benzo[k]fluoranthene (9.4%), pyrene (8.9%), and benzo[a]pyrene (8.3%) are found to be the most common PAH compounds in the particulate phase. The results from application of principal component analysis to particulate-phase PAH data demonstrate that a combination of PAH and $PM_{2.5}$ inorganic data is a more powerful tracer of emission sources than PAH species data alone. Particulate-phase PAH species were found to be associated predominantly with emissions from diesel engine vehicles and incineration.

직분식 엔진에서 실린더 내 연료의 액.기상 거동에 미치는 텀블과 스월의 영향 (The Effects of Tumble and Swirl Flow on the Behavior of Liquid/Vapor Phases in a DI Gasoline Engine)

  • 강정중;최동석;김덕줄
    • 한국자동차공학회논문집
    • /
    • 제10권2호
    • /
    • pp.23-30
    • /
    • 2002
  • This present study experimentally investigates the behavior of liquid and vapor phase of fuel mixtures with changing the in-cylinder air motion in an optically accessible engine. The conventional MPI/DOHC engine was modified to gasoline direct injection engine with swirl motion. The images of liquid and vapor phases were captured in the motoring operation condition using exciplex fluorescence method. Two dimensional spray fluorescence images of liquid and vapor phases were acquired to analyze spray behaviors and fuel distribution inside of cylinder respectively, In early injection timings $(BTDC\;270^{\circ},\;180^{\circ})$, tumble flow transported most of vapor phase to the lower region and the both sides of cylinder, so vapor phase didn't become uniform distribution up to the half of the compression stroke. In the case of swirl flow, the fuel mixture was confined near the swirl origin in upper region of cylinder. In late injection timings $(BTDC\;90^{\circ})$, tumble flow transported vapor phase to the intake valve and swirl flow to the exhaust valve.