• 제목/요약/키워드: Vapor Volume Fraction

검색결과 48건 처리시간 0.024초

LNG추출과정과 냉열이용의 열역학적 해석 (Thermodynamic Analysis of the Extraction Process and the Cold Energy Utilization of LNG)

  • 이근식;장영수;노승탁
    • 설비공학논문집
    • /
    • 제7권1호
    • /
    • pp.120-131
    • /
    • 1995
  • Thermodynamic analysis of extraction process from the constant pressure LNG(Liquefied Natural Gas) vessel was performed in this study. LNG was assumed as a binary mixture of 90% methane and 10% ethane by mole fraction. The thermodynamic properties such as temperature, composition, specific volume and the amount of cold energy were predicted during extraction process. Pressure as a parameter ranges from 101.3kPa to 2000kPa. The result shows the peculiar phenomena for the LNG as a mixture. Both vapor and liquid extraction processes were investigated by a computer model. The property changes are negligible in the liquid extraction process. For the vapor extraction process, the temperature in the vessel increases rapidly and the extracted composition of methane decreases rapidly near the end of extracting process. Specific volume of vapor has the maximum and that of liquid has the minimum during the process. When pressure is increased, specific volume of vapor decreases and that of liquid increases. It was found that specific volume of vapor phase had a major effect on the heat absorption at constant pressure during vapor extraction process. If the pressure of the vessel increases, the total cold energy which can be utilized from LNG decreased.

  • PDF

캐비테이션 억제를 위한 감압밸브의 유로 형상에 관한 연구 (Study of the geometry of the flow path of a Pressure Reducing Valve to Suppress the Cavitations)

  • 박우철;김일겸
    • 한국산학기술학회논문지
    • /
    • 제16권1호
    • /
    • pp.50-55
    • /
    • 2015
  • 본 연구에서는 공동 주택의 수전 개방 조건에서, 감압밸브 내부 오리피스 형상이 캐비테이션 발생에 미치는 영향에 대하여 살펴보았다. 이를 위하여 감압밸브 내부의 유로형상을 9가지 유형으로 구별하여 제시하고, 3차원 유한해석 코드인 ANSYS CFX를 사용하여 감압밸브 내의 유동해석을 수행하였다. 급격한 단면 변화가 일어나는 오리피스에서 최저 압력과 최대 속도가 발생하였다. 최대속도가 존재하는 부위에서 0 이상 증기체적비를 나타내어 캐비테이션이 발생함을 확인하였다. 유로 길이가 긴 형상에 비하여 돌연 확대관 형상의 모델에서 유체의 최대 속도가 낮게 나타났다. 돌연확대관 형상의 경우에는 매우 작은 증기체적비를 나타내고 있으며, 돌연확대의 정도가 클수록 증기체적비는 낮게 나타났다. 따라서 감압밸브의 케비테이션 발생을 방지하기 위해서는 돌연확대의 형상을 갖도록 설계하는 것이 타당하다고 판단된다.

플라즈마 아크 방전법에서 Fe 나노 분말 형성에 미치는 공정변수의 영향 (Effect of the Process Parameters on the Fe Nano Powder Formation in the Plasma Arc Discharge Process)

  • 이길근;김성규
    • 한국분말재료학회지
    • /
    • 제10권1호
    • /
    • pp.51-56
    • /
    • 2003
  • To investigate the effect of the parameters of the plasma arc discharge process on the particle formation and particle characteristics of the iron nano powder, the chamber pressure, input current and the hydrogen volume fraction in the powder synthesis atmosphere were changed. The particle size and phase structure of the synthesized iron powder were studied using the FE-SEM, FE-TEM and XRD. The synthesized iron powder particle had a core-shell structure composed of the crystalline $\alpha$-Fe in the core and the crystalline $Fe_3O_4$ in the shell. The powder generation rate and particle size mainly depended on the hydrogen volume fraction in the powder synthesis atmosphere. The particle size increased simultaneously with increasing the hydrogen volume fraction from 10% to 50%, and it ranged from about 45nm to 130 nm.

SiCf/SiC 복합체의 화학기상침착 거동에 미치는 권선 구조와 침착 변수의 영향 (Influence of Winding Patterns and Infiltration Parameters on Chemical Vapor Infiltration Behaviors of SiCf/SiC Composites)

  • 김대종;고명진;이현근;박지연;김원주
    • 한국세라믹학회지
    • /
    • 제51권5호
    • /
    • pp.453-458
    • /
    • 2014
  • SiC and its composites have been considered for use as nuclear fuel cladding materials of pressurized light water reactors. In this study, a $SiC_f$/SiC composite as a constituent layer of SiC triplex fuel cladding was fabricated using a chemical vapor infiltration (CVI) process in which tubular SiC fiber preforms were prepared using a filament winding method. To enhance the matrix density of the composite layer, winding patterns, deposition temperature, and gas input ratio were controlled. Fiber arrangement and porosity were the main parameters influencing densification behaviors. Final density of the composites decreased as the SiC fiber volume fraction increased. The CVI process was optimized to densify the tubular preforms with high fiber volume fraction at a high $H_2$/MTS ratio of 20 at $1000^{\circ}C$; in this process, surface canning of the composites was effectively retarded.

SiCf/SiC 복합체 튜브의 표면조도 및 섬유 부피 분율에 미치는 필라멘트 와인딩 방법의 영향 (Effect of Filament Winding Methods on Surface Roughness and Fiber Volume Fraction of SiCf/SiC Composite Tubes)

  • 김대종;이종민;박지연;김원주
    • 한국세라믹학회지
    • /
    • 제50권6호
    • /
    • pp.359-363
    • /
    • 2013
  • Silicon carbide and its composites are being considered as a nuclear fuel cladding material for LWR nuclear reactors because they have a low neutron absorption cross section, low hydrogen production under accident conditions, and high strength at high temperatures. The SiC composite cladding tube considered in this study consists of three layers, monolith CVD SiC - $SiC_f$/SiC composite -monolith CVD SiC. The volume fraction of SiC fiber and surface roughness of the composite layer affect mechanical and corrosion properties of the cladding tube. In this study, various types of SiC fiber preforms with tubular shapes were fabricated by a filament winding method using two types of Tyranno SA3 grade SiC fibers with 800 filaments/yarn and 1600 filaments/yarn. After chemical vapor infiltration of the SiC matrix, the surface roughness and fiber volume fraction were measured. As filament counts were changed from 800 to 1600, the surface roughness increased but the fiber volume fraction decreased. The $SiC_f$/SiC composite with a bamboo-like winding pattern has a smaller surface roughness and a higher fiber volume fraction than that with a zigzag winding pattern.

대기 중 유기염소계 살충제의 가스-입자 분배 (Gas-particle Partitioning of Organochlorine Pesticides in Atmosphere)

  • 최민규;천만영
    • 한국대기환경학회지
    • /
    • 제23권4호
    • /
    • pp.457-465
    • /
    • 2007
  • This study was performed to estimate the gas-particle partitioning of organochlorine pesticides (OCPs) in atmosphere, the samples were collected by PUF high volume air sampler for two years from June, 2000 to June, 2002. The gas phase fraction of ${\alpha/\gamma}-HCH$, heptachlor epoxide, ${\alpha/\gamma}-chlordane$ and trans-nonachlor was over 90%. But the gas phase fraction of ${\beta}-HCH$, p,p'-DDE, endosulfan sulfate, p,p'-DDD and p,p'-DDT was range of 20% through 80%, which means the gas phase fraction of OCPs components described above is sensitive to temperature. The correlation between the gas phase fraction and molecular weight of each OCPs component was not found in this research. The slope of regression line between gas-particle partitioning coefficient(${\log}K_p$) and subcooled liquid vapor(${\log}{P^o}_L$), gal-particle partitioning coefficient(${\log}K_p$) and octanol-air partitioning coefficient(${\log}K_{oa}$) which show -0.54 and 0.43 was not steep. So the equilibrium state between gas and particle was not reached and in this state the particulate fraction was low.

발전소용 고압 바이패스 밸브 내부 유동해석 (Analysis of Flow through High Pressure Bypass Valve in Power Plant)

  • 조안태;김광용
    • 한국유체기계학회 논문집
    • /
    • 제10권6호
    • /
    • pp.17-23
    • /
    • 2007
  • In the present work, flow analysis has been performed in the steam turbine bypass control valve (single-path type) for two different cases i.e., case with steam only and case with both steam and water. The numerical analysis is performed by solving three-dimensional Reynolds-averaged Navier-Stokes (RANS) equations. The shear stress transport (SST) model and $k-{\varepsilon}$ model are used to each different case as turbulence closure. Symmetry condition is applied at the mid plane of the valve while adiabatic condition is used at the outer wall of the cage. Grid independency test is performed to find the optimal number of grid points. The pressure and temperature distributions on the outer wall of the cage are analyzed. The mass flow rate at maximum plug opening condition is compared with the designed mass flow rate. The numerical analysis of multiphase mixing flow(liquid and vapor) is also performed to inspect liquid-vapor volume fraction of bypass valve. The result of volume fraction is useful to estimate both the safety and confidence of valve design.

Two-Phase Flow Field Simulation of Horizontal Steam Generators

  • Rabiee, Ataollah;Kamalinia, Amir Hossein;Hadad, Kamal
    • Nuclear Engineering and Technology
    • /
    • 제49권1호
    • /
    • pp.92-102
    • /
    • 2017
  • The analysis of steam generators as an interface between primary and secondary circuits in light water nuclear power plants is crucial in terms of safety and design issues. VVER-1000 nuclear power plants use horizontal steam generators which demand a detailed thermal hydraulics investigation in order to predict their behavior during normal and transient operational conditions. Two phase flow field simulation on adjacent tube bundles is important in obtaining logical numerical results. However, the complexity of the tube bundles, due to geometry and arrangement, makes it complicated. Employment of porous media is suggested to simplify numerical modeling. This study presents the use of porous media to simulate the tube bundles within a general-purpose computational fluid dynamics code. Solved governing equations are generalized phase continuity, momentum, and energy equations. Boundary conditions, as one of the main challenges in this numerical analysis, are optimized. The model has been verified and tuned by simple two-dimensional geometry. It is shown that the obtained vapor volume fraction near the cold and hot collectors predict the experimental results more accurately than in previous studies.

다단 원심펌프의 공동현상 유동해석 (Cavitating Flow Analysis of Multistage Centrifugal Pump)

  • 라키부자만;서상호;김형호;조민태;신병록
    • 한국유체기계학회 논문집
    • /
    • 제18권1호
    • /
    • pp.65-71
    • /
    • 2015
  • The purpose of this study is to investigate cavitating flow of the multistage centrifugal pump. Cavitation is observed in the impeller leading edge and trailing edge of the suction area. Head coefficients are measured under different flow operating conditions. The Rayleigh-Plesset cavitation model is adapted to predict the occurrence of cavitation in the pump. The two-phase gas-liquid homogeneous CFD method is used to analyze the centrifugal pump performances with two equation transport turbulence model. The simulations are carried out with three different flow coefficients such as 0.103, 0.128 and 0.154. The occurrence of cavitation described according to water vapor volume fraction. The head versus NPSH (Net Positive Suction Head) also measured using different flow coefficients. Development of cavitation in the centrifugal pump impellerI is discussed. It is showed that the simulation represents the head drop about 3%.

Degradation analysis of horizontal steam generator tube bundles through crack growth due to two-phase flow induced vibration

  • Amir Hossein Kamalinia;Ataollah Rabiee
    • Nuclear Engineering and Technology
    • /
    • 제55권12호
    • /
    • pp.4561-4569
    • /
    • 2023
  • A correct understanding of vibration-based degradation is crucial from the standpoint of maintenance for Steam Generators (SG) as crucial mechanical equipment in nuclear power plants. This study has established a novel approach to developing a model for investigating tube bundle degradation according to crack growth caused by two-phase Flow-Induced Vibration (FIV). An important step in the approach is to calculate the two-phase flow field parameters between the SG tube bundles in various zones using the porous media model to determine the velocity and vapor volume fraction. Afterward, to determine the vibration properties of the tube bundles, the Fluid-Solid Interaction (FSI) analysis is performed in eighteen thermal-hydraulic zones. Tube bundle degradation based on crack growth using the sixteen most probable initial cracks and within each SG thermal-hydraulic zone is performed to calculate useful lifetime. Large Eddy Simulation (LES) model, Paris law, and Wiener process model are considered to model the turbulent crossflow around the tube bundles, simulation of elliptical crack growth due to the vibration characteristics, and estimation of SG tube bundles degradation, respectively. The analysis shows that the tube deforms most noticeably in the zone with the highest velocity. As a result, cracks propagate more quickly in the tube with a higher height. In all simulations based on different initial crack sizes, it was observed that zone 16 experiences the greatest deformation and, subsequently, the fastest degradation, with a velocity and vapor volume fraction of 0.5 m/s and 0.4, respectively.