• Title/Summary/Keyword: Vane Type

Search Result 193, Processing Time 0.026 seconds

A Study on Power Performance of a 1kW Class Vane Tidal Turbine

  • Yang, Changjo;Nguyen, Manh Hung;Hoang, Anh Dung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.2
    • /
    • pp.143-151
    • /
    • 2015
  • Recently, tidal current energy conversion is a promising way to harness the power of tides in order to meet the growing demands of energy utilization. A new concept of tidal current energy conversion device, named Vane Tidal Turbine (VTT), is introduced in this study. VTT has several special features that are potentially more advantageous than the conventional tidal turbines, such as propeller type tidal turbines. The purpose of this study on VTT is to analyze the possibility of extracting the hydrokinetic energy of tidal current and converting it into electricity, and evaluate the performance of turbines for various numbers of blades (six, eight and twelve) using Computational Fluid Dynamics (CFD). At various tip-speed ratios (TSR), the six-bladed turbine obtains the highest power and torque coefficients, power efficiency is up to 28% at TSR = 1.89. Otherwise, the twelve blade design captures the smallest portion of available tidal current energy at all TSRs. However, by adding more blades, torque extracted from the rotor shaft of twelve-bladed turbine is more uniform due to the less interrupted generation of force for a period of time (one revolution).

A Study ono the Type-Change of Automotive Register (차내 환기구 형상변화에 대한 연구)

  • Kim, Jong-Won;Youn, Jong-Gap;Bae, Han;Won, Sung-Pil
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.6
    • /
    • pp.123-134
    • /
    • 1999
  • Nowadays since the automobile is regarded as the third living space, comfortable conditions are required in the passenger compartment. The customer's concern on air-conditioning/heating, ventilation and demisting/defrosting performances has been much increased. Both ventilation and demisting /defrosting performances are directly influenced by register location, shape of regist guide vane, ventilation flow rate, air distribution , and air circulation pattern. Diffuse plume of air from the register is desirable not only to maintain comfort when the comfort when the comfortable condition has been satisfied but to improve demisting /defrosting performance. In this study, experimental and numerical investigation about the flow field of six different register vane types were carried out , respectively. The numerical analysis, based upon the $textsc{k}$-$\varepsilon$ turbulence model , was applied to the air flow field. The results show that the shape of register guide vane should be considered as an important design paramter.

  • PDF

An Analysis of the Performance of a Combined Expander-Compressor Unit for a CO2 Automotive Air Conditioning Cycle (차량용 CO2 에어컨 사이클 성능 향상을 위한 일체형 팽창기-압축기 성능 해석)

  • Choi, Jae Woong;Lim, Jeong Taek;Kim, Hyun Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.3
    • /
    • pp.107-115
    • /
    • 2018
  • A design combining the use of a compressor and expander was introduced in order to improve the cycle performance of a $CO_2$ automotive air conditioning system. Both the compressor and expander used were of rotary vane type and were designed to share a common shaft in a housing. Numerical simulation was carried out to evaluate the merit of the combined unit. In a typical automotive air conditioning operating conditions, the COP of the system was improved by 8.7% by the application of the combined unit. The compressor input was reduced by 5.2% through use of the expander output. In addition, about 3.06% increase in the cooling capacity was obtained through isentropic expansion in the expander. Our study noted that, as the pressure difference between the gas cooler and the evaporator becomes larger, the COP of the system improved increases unless the mass flow rate in the expander exceeds that in the compressor.

Performance Analysis of Vane Rotary Expander for $CO_2$ Cycles ($CO_2$ 사이클용 로타리 베인 팽창기 성능해석)

  • Kim, Ho-Young;Ahn, Jong-Min;Kim, Hyun-Jin;Cho, Sung-Oug
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.1
    • /
    • pp.55-62
    • /
    • 2009
  • Relatively low cycle performance of a conventional $CO_2$ system is partly due to significant increase in friction loss in the expansion process, since the pressure drop across the expansion device is considerably large compared to a conventional refrigeration cycle. To recover friction loss and increase refrigeration effect by providing isentropic expansion, a rotary vane type expander has been designed. Performance of the designed expander has been investigated by numerical simulation. With the pressure condition of 9 MPa/4.5 MPa and inlet temperature of $35^{\circ}C$, volumetric, isentropic, and mechanical efficiencies of the expander are calculated to be 58.1%, 101.1%, and 78.8%, respectively, resulting in total expander efficiency of 46.3%. With this expander, COP of a $CO_2$ refrigeration cycle is estimated to be improved by about 14%.

Prediction of Pressure Drop Using the Internal Flow Simulation of Pulse Air Jet Bag Filters (충격기류식 여과집진기의 내부 유동 시뮬레이션 해석을 통한 압력손실 예측)

  • Jang, Kyeong-Min;Jung, Eun-Sang;Suh, Jeong-Min
    • Journal of Environmental Science International
    • /
    • v.29 no.5
    • /
    • pp.457-468
    • /
    • 2020
  • With continuous industrial development, the types, and amount of particulate matter (PM) have been increasing. Since 2018, environmental standards regarding PM have become more stringent. Pulse air jet bag filters are suitable for PM under the 20 ㎛ and, can function regardless of size, concentration and type. Filtration velocity and shape are important factors in the operation and design of the pulse air jet bag filters however, few established studies support this theory. In this research, numerical simulations were conducted based on experimental values and, several methods were employed for minimizing the pressure drop. In the pilot system, as the inlet duct velocity was faster than 19 m/sec, flow was not distributed equally and, re-entrainment occurred due to the hopper directional vortex. The multi-inlet system decelerated the hopper directional vortex by 25 ~ 30%, thereby decreasing total pressure drop by 6.6 ~ 14.7%. The guide vane system blocked the hopper directional vortex, which resulted optimal vane angle of 53°. The total pressure of the guide vane system increased by 0.5 ~ 3% at 1.5 m/min conditions. However, the filtration pressure drop decreased by 4.8 ~ 12.3% in all conditions, thereby reducing the operating cost of filter bags.

A Comparison of Performance of Six and Twelve-Blade Vane Tidal Turbines between Single and Double Blade-row Types (블레이드 열의 배치에 따른 베인형 조류 수차의 성능 비교)

  • Nguyen, M.H.;Kim, J.H.;Kim, B.K.;Yang, C.
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.1
    • /
    • pp.51-58
    • /
    • 2015
  • This paper presents a study on Vane Tidal Turbine (VTT) focusing on analysis of two types of blade arrangement originated from the previous studies where the original design was examined and performance-tested for different numbers of blades (six, eight and twelve). Compared to conventional tidal turbines, VTT has several special features and potential advantages which have been being thoroughly developed. The purpose of this study is to analyze VTT's capability of extracting and converting the hydrokinetic energy of tidal currents into electricity at given arrangement of blades (single and double rows, six and twelve blades) using CFD. From the calculation results, the six-blade single row turbine shows the best performance, in which the highest power and torque coefficients reach up to about 34 % and 36 %, respectively, at TSR=0.94. However, despite of lower power coefficient, by adding more blades, the torque's extraction of twelve-blade turbine, especially the double row type, is less fluctuate than that of the six-blade setups.

Effect of Various Gums on Flow Properties and Yield Stress of Korean Sweet Potato Starch (여러 종류의 검 첨가가 국내산 고구마전분의 유동특성 및 Vane 항복응력에 미치는 영향)

  • Choi, Hye-Mi;Yoo, Byoung-Seung
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.38 no.9
    • /
    • pp.1253-1257
    • /
    • 2009
  • The effects of seven commercial gums (xanthan gum, guar gum, pectin, gum arabic, gellan, locust bean gum, and sodium alginate) at different concentrations (0, 0.3, and 0.6%) on flow properties of sweet potato starch (SPS) pastes were investigated. Flow behavior characteristics were adequately described by power law flow model, and yield stress was also measured by vane method. SPS-gum mixtures (5% w/w) at $25^{\circ}C$ were found to have high shear-thinning flow behavior with yield stress, and their consistency index (K) and apparent viscosity ($\eta_{a,100}$) increased with elevated gum concentration, except for pectin and sodium alginate. Vane yield stress ($\sigma_o$) value of SPS-pectin mixture was lower when compared to other mixtures while that of SPS-gellan mixture was much higher. Most of the gums, except for pectin, gum arabic, and sodium alginate, showed a synergistic effect on the elastic properties of SPS-gum mixtures. In general, the flow properties of SPS-gum mixtures appeared to be strongly influenced by the addition of gum, and dependent on the type and concentration of gum.

Development of automatic impeller type small hydropower system (임펠러방식 능동형 소수력 시스템 개발)

  • Kang, Seok-Won;Oh, Min-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1458-1459
    • /
    • 2015
  • 본 논문은 해수의 조류발전으로 일반적으로 이용되고 있는 다리우스 타입 터빈의 구동력과 효율의 개선을 위하여 능동형 가이드밴(Guide Vane)과 Reaction Blade을 응용하여 설계하므로 구동력과 효율을 개선하고자 하였다.

  • PDF

NUMERICAL STUDY ON FLOW CHARACTERISTIC IN THE HEAT RECOVERY STEAM GENERATOR (배열회수장치의 유동특성에 관한 수치적 연구)

  • Choi, H.K.;Yoo, G.J.;Shin, B.J.;Kim, C.H.
    • Journal of computational fluids engineering
    • /
    • v.15 no.1
    • /
    • pp.17-23
    • /
    • 2010
  • Performance improvements of the heat recovery steam generator(HRSG) can be achieved by improving the flow distribution of exhaust gases for a various type of different equipments. A number of design parameters are systematically investigated and their effects on an index of velocity deviation established. The parameters include the three shape of the transition duct and the wide range of the guide vane angles. The numerical results clearly reveal feature of the flow pattern in the transition duct, velocity deviation and pressure drop at tube bank part.