Optimization of Diesel Engine Performance with Dual Loop EGR considering Boost Pressure, Back Pressure, Start of Injection and Injection Mass (과급압력, 배압, 분사 시기 및 분사량에 따른 복합 방식 배기 재순환 시스템 적용 디젤 엔진의 최적화에 대한 연구)

  • Park, Jung-Soo;Lee, Kyo-Seung;Song, Soon-Ho;Chun, Kwang-Min
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.18 no.5
    • /
    • pp.136-144
    • /
    • 2010
  • Exhaust gas recirculation (EGR) is an emission control technology allowing significant NOx emission reduction from light-and heavy duty diesel engines. The future EGR type, dual loop EGR, combining features of high pressure loop EGR and low pressure loop EGR, was developed and optimized by using a commercial engine simulation program, GT-POWER. Some variables were selected to control dual loop EGR system such as VGT (Variable Geometry Turbocharger)performance, especially turbo speed, flap valve opening diameter at the exhaust tail pipe, and EGR valve opening diameter. Applying the dual loop EGR system in the light-duty diesel engine might cause some problems, such as decrease of engine performance and increase of brake specific fuel consumption (BSFC). So proper EGR rate (or mass flow) control would be needed because there are trade-offs of two types of the EGR (HPL and LPL) features. In this study, a diesel engine under dual loop EGR system was optimized by using design of experiment (DoE). Some dominant variables were determined which had effects on torque, BSFC, NOx, and EGR rate. As a result, optimization was performed to compensate the torque and BSFC by controlling start of injection (SOI), injection mass and EGR valves, etc.

Isolating Subsystems by Valves in a Water Distribution System and Evaluating the System Performance (상수관망에서의 밸브에 의한 관의 부분적 격리와 상수관망의 효율성 평가)

  • Jun, Hwan-Don
    • Journal of Korea Water Resources Association
    • /
    • v.38 no.7 s.156
    • /
    • pp.585-593
    • /
    • 2005
  • Recent concerns regarding protecting, identifying, isolating, redundant routing and dewatering of subsystems of water distribution networks have led to the realization of the importance of valves in these systems. Valves serve two purposes namely, flow and pressure control and isolating subsystems due to breakage or contaminant containment. In this paper, valves are considered from the point of view of subsystem isolation. When a water main is required to be closed, it may be in general necessary to close several other pipes in addition to the broken pipe itself depending on the distribution of adjacent valves. This set of pipes is defined as a segment. In this paper a segment analysis for isolating pipes is present and based on the segment analysis, we suggested the Valve Importance Index and the 7 performance indicators to evaluate the system performance. The suggested methodology is applied to a real network to verify the applicability of the methodology.

Analysis on Vehicle Fires Caused by Damage of Diesel Particulate Filter (DPF) (매연저감장치 손상에 기인한 차량화재 사고사례 분석)

  • Song, Jae-Yong;Sa, Seung-Hun;Nam, Jung-Woo;Cho, Young-Jin;Kim, Jin-Pyo;Park, Nam-Kyu
    • Fire Science and Engineering
    • /
    • v.26 no.4
    • /
    • pp.70-76
    • /
    • 2012
  • This paper deal with vehicle fire caused by damage of diesel particulate filter (DPF) on diesel passenger vehicles. In order to reduce particulate matters included exhaust gases, a DPF in the exhaust system were installed diesel vehicles. A DPF was broken by excessively trapped particulate matters, regeneration error with a malfunction of ECU and defect of suction system such as swirl valve. If the DPF was broken, hot exhaust gases was released to the bottom of vehicle and released hot exhaust gases lead to occur the fire through combustible materials around the exhaust system. When a fire happened in the diesel vehicle caused by damage of DPF, silicate inorganic compounds were attached to the exhaust ventilation pipe and muffler. The silicate inorganic compounds were created by DPF combustion consisting of raw material ceramics. If the silicate inorganic compounds attached to the tail pipe in the diesel passenger vehicles, its fire cause will be assumed damage of DPF.

A Study on the combustion characteristcs for backpressure of exhaust system in SI engine (배기(排氣)시스템의 배압(背壓)과 연소특성(燃燒特性)에 관한 연구)

  • Park, Dai-Un;Park, Kyoung-Suk;Park, Se-Jong;Son, Sung-Man
    • 한국연소학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.206-212
    • /
    • 2004
  • It is necessary to consider the stability, economic environmental-friendly problems by the development of the road, supply of the automobile, environmental problem as designing the exhaust system. To reduce the noise and the vibration of the automobile, it is needed to consider the pulsation noise, air current noise, vibration of air pipe which generate the intake and exhaust noise of the automobile. Moreover, the discharge sounds, intake sound, radiation sound, transmitted sound are occurred. To reduce this influence, the variable valve is needed and to control these factors, path transformation muffler and active type muffler are needed. While engine efficiency could be reduced with this transformationand resistance by the pressure, thermal property. In this study, how to design exhaust systems yielding higher condversion efficiency, lower backpressure and optimize the performance. this study is recommended for exhaust system and designers and engineers involved in SI engine exhaust system and it will furnish information for you to design more efficient.

  • PDF

A study on the free surface vortex in the pipe system (배관내 자유수면에서 와류현상에 대한 연구)

  • 오율권;장완호;이종원;김상녕
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.11
    • /
    • pp.2126-2135
    • /
    • 1992
  • In order to prevent the decay heat removal system from failure due to air entrainment or free surface vortex in the piping system, a set of simulating experiments for the midloop operation of nuclear power plant was performed. Through these experiments, a relation between the dimensionless numbers, such as submergence H/d, froude number, reynolds number, was found. However, the effect of reynolds number was negligible for the operation conditions of Nuclear power plant. It was also found that the perturbation of the system by the disturbance such as pump start, valve operation, etc., has a strong effect on the free surface vortex. Furthermore, from a view point of reactor safery, a modified inlet device of reducer type is strongly recommendable for the prevention of air entrainment.

Analysis on Heat Supply Piping Network for Apartment House (아파트의 온수공급배관망해석)

  • 박윤철;황광일
    • Journal of the Korean housing association
    • /
    • v.13 no.6
    • /
    • pp.89-99
    • /
    • 2002
  • The purpose of this research is to analyze the characteristics of flow rate distribution in hot-water piping networks in the apartment building. A 14-story apartment house was selected as a sample building and analyzed numerically by Hardy-Cross method. Two different piping networks, one has three vertical zones and the other of a single zone with automatic balancing valves, were compared. Some of research results are as follows; As the temperature of supply hot-water increases, the flow rate of it does by buoyancy effect, but this effect is not found in the piping network with automatic balancing valves. Non-uniformity in hot-water flow distributions to all stories in the piping system of single vertical zone can be completely reformed by the installation of either manually operated or automatic balancing valves in every story.

Installation effects on the characteristics of multi-path ultrasonic flowmeter (배관 형상이 다회선 초음파 유량계의 특성에 미치는 영향)

  • Park, K. A.;Choi, Y. M.;Choi, H. M.;Yoon, B. R.;Hwang, K. B.
    • 유체기계공업학회:학술대회논문집
    • /
    • 1999.12a
    • /
    • pp.114-117
    • /
    • 1999
  • Five-path ultrasonic flowmeters (200 and 300 mm diameters) were tested to obtain it's characteristics in a water flow standard system. A five-path ultrasonic flowmeter was installed after various pipe fittings (elbow, valve, tee) or a pump. The distance between flow disturbance source and a flowmeter was main experimental parameter. Without a flow conditioner, a five-path ultrasonic flowmeter shows good characteristics as the distance between flow disturbance source and a flowmeter is longer than 10 diameter of a flowmeter.

  • PDF

A Study on Fluid Thansient Accommpanying Cilumn Separation in Oil Hydraulic Pipeline -Investigation on Two-Step Pressure Rise (유압 관로계에서 액주분리를 수반하는 유체과도현상에 관한 연구 -2단입력 상승현상에 관하여-)

  • 염만오;이진걸;이일영;김현기
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.5
    • /
    • pp.984-991
    • /
    • 1988
  • Liquid column separation occurs when the valve on the pipeline is closed rapidly in an oil hydraulic system. In this case two-step pressure rise is sometimes observed in a comparatively short pipeline. In this study the two-step pressure rise phenomenon was investigated experimentally and theoretically. The experiments showed that maximum pressure values during two-step pressure rise might exceed extremely the values computed by the theory of rigid-liquid-column separation. So the two-step pressure rise phenomenon appears one of important factors of pipe strength design. From the theoretical considerations based on the experimental and numerical results, the mechanism of two-step pressure rise phenomenon could be explained clearly.

Design of small impact test device for concrete panels subject to high speed collision

  • Kim, Sanghee;Jeong, Seung Yong;Kang, Thomas H.K.
    • Advances in concrete construction
    • /
    • v.7 no.1
    • /
    • pp.23-30
    • /
    • 2019
  • Five key items were used to create an economical and physically small impact test device for concrete panels subject to high speed collision: an air-compressive system, carbon steel pipe, solenoid valve, carrier and carrier-blocking, and velocity measurement device. The impact test device developed can launch a 20 mm steel spherical projectile at over 200 m/s with measured impact and/or residual velocity. Purpose for development was to conduct preliminary materials tests, prior to large-scale collision experiments. In this paper, the design process of the small impact test device was discussed in detail.

Analytic study on thermal management operating conditions of balance of 100kW fuel cell power plant for a fuel cell electric vehicle (100kW급 연료전지 열관리 시스템 실도로 운전조건 해석적 연구)

  • Lee, Ho-Seong;Lee, Moo-Yeon;Cho, Choong-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.1-6
    • /
    • 2019
  • The objective of this study was to investigate performance characteristics of thermal management system(TMS) in a fuel cell electric vehicle with 100kW Fuel Cell(FC) system. In order to build up analytic modelling for TMS, each component was installed and tested under various operating conditions, such as water pump, radiator, 3-Way valve, COD heater, and FC stack etc. and as the results of them, correlations reflecting component's characteristics with flow rate, air velocity were developed. Developed analytic modelling was carried out under various operating conditions on the road. To verify modelling's accuracy, after prediction for optimum coolant flow rate was fulfilled under certain operating conditions, such as FC system, water pump speed, opening of 3-way valve, and pipe resistance, analytic and experimental values were compared and good agreement was shown. In order to predict cold-start operating performance for analytic modelling, coolant temperature variation was analyzed with $-20^{\circ}C$ ambient temperature and duration was predicted to rise in optimum temperature for FC. Because there is appropriate temperature difference between inlet and outlet of FC stack to operate FC system properly, related analysis was performed with respect to power consumption for TMS and heat rejection rate and performance map was depicted along with FC operating conditions.