The stem thrust required to unwedging a gate valve is influenced by the pressure and temperature when the valve is closed and by the changes in these conditions between closure and opening. "Pressure Locking" and "Thennal Binding" refer to situations where pressure and temperature effects cause the unwedging load to be much higher than normal. A model of these phenomena has been developed. The effects of pressure and temperature are analyzed to determine the change in this disk-to-seat "interference". Flexibilities or Stiffness of the disk and body strongly influence the unwedging thrust. Calculation and limited comparison to data have been performed for the RHR motor operated valve designs and scenario. Pressure changes can increase the unwedging thrust when bonnet pressure exceeds the pressure in the adjacent piping and temperature changes can increase the unwedging thrust when a temperature change after closure produces an increase in the disk-to-seat interference.
Continuously contacting with camshaft the face of Valve Lifter made of cast iron brings about abnormal wear such as unfairwear or earlywear because it is heavily loaded in the valve train systems as the engine gets more powered. This abnormal wear becomes a defet namely over-clearance when the valve is lifting so that the fuel gas imperfectly combusted by unsuitable open or close aaction of the engine valve in the combustion chamber. The imperfect combustion in the end results in the major cause of air pollution and combustion chamber. The imperfectly combusted by unsuitable open or close action of the engine valve in the combustion chamber. The imperfect combustion in the end results in the major causes of air pollution and decrease of the engine output. Consequently to prevent this wear this study was to develop the valve lifter which is joined by brazing process with SCM435H and a tip by manufacturing the face as a superhardened which is joined by brazing process with SCM435H and a tip by manufacturing the face as a superhardened ceramics alloy which has high wear resistance. Having the excellent surface hardness with Hv1100-1200 the sintered body developed with superhardened alloy(WC) can endure the severe face loading in the valve train system. We experienced with various brazing alloys and obtained the excellent joining strength to the joint had 150MPa shear strength. Interface analysis and microstructure in a joint were examined through SEM & EDS Optical microscope. Also 2,500 hours high speed(3,000-4,000 rpm) and continuous (1step 12hr) engine dynamo testing was carried out to casting valve liter and ceramics-metal joint valve lifter so that the abnormal wears were compared and evaluated.
Journal of the Korean Society for Nondestructive Testing
/
v.30
no.2
/
pp.110-115
/
2010
This study was conducted to estimate the feasibility using thermal image measurement that is applicable to internal leak diagnosis for the power plant valve. Abnormal heating of valve surface associated with high temperature steam f10w toward valve outlet side in the condition of low temperature is a primary indicator of leakage problems in high temperature and pressure valves. Thermal imaging enables to see the invisible thermal radiation that may portend impending damage before their condition becomes critical. When steam flow in valve outlet side in the condition of low temperature is converted into heat transmitted through the valve body due to the internal leakage in valve. The existence of abnormally increasable leakage rate in the valve will result in abnormally high levels of heat to be generated that can be quickly identified with a thermal image avoiding energy loss or damage of valve component. From the experimental results, it was suggested that the thermal image measurement could be an effective way to precisely diagnose and evaluate internal leak situation of valve.
One hundred eighty-eight patients[August.23,1988,through July.30,1994 underwent aortic[AVR , mitral[MVR , or double [DVR valve replacement with the St.Jude Medical prosthesis. The author analyzed 100 patients with valvular heart disease,who underwent valve replacement with the St.Jude Medical prothesis from 1990 to 1994, at Hanyang University hospital Cardiovascular department. Information on volume and functional change of the heart chamber can be obtained by cardiac echocardiography and cartheterization. Out of 100 patients, 40 patients were male[40% and 60 patients were female [60% . Age ranged from 13 years to 68 years, with mean age of 42.6 years. Mean height was 160.3cm and mean body weight was 54.9Kg. According to NYHA functional classification, class III is most frequent and 60 patients could be classfied under it. MVR [involved Redo MVR was performed in 40 patients, AVR [involved Redo AVR was performed in 18 patients, and DVR [involved Redo DVR was performed in 42 patients. Warfarin [Coumadin anticoagulation was recommended for all patients. Life long warfarin anticoagulation was necessary to all patients who underwent valve replacement with St.Jude Medical prosthesis. Ideal prothrombin time was maintained about 30% during warfarinization. There were no case of mechanical failure. It followed a comparison of echocardiography before and after valve replacement at Hanyang University hospital [30 patients and a preoperative evaluation of cardiac catheterization and angiography [64 patients . The St.Jude Medical cardiac valve is a viable alternative in the surgical therapy of valvular heart disease.
A valve assembly used in nuclear power plants must be qualified and supervised. New technical standards such as ASME QME-1 2007 particularly require detailed qualification using experiment and analysis. Particularly, diagnostic tests and engineering studies are required for qualification of ASME QME-1 2007. Among these studies, the research on the measurement of friction coefficient and packing stress is important. The irregular change of packing stress along the stroke distance occurs because of the abnormal phenomenon, which must be found and studied with quantitative methods. Packing stress should be analyzed conservatively through experimentation and analysis. In this study, various formulas were applied to measure and calculate coefficient of friction and packing stress. This study can be used in relation to qualification and supervision of packing materials. And the calculation using static diagnosis test can be used to find the packing frictional force in dynamic diagnosis test with flow pressure in a pipe. This study has made it possible to reliably consider packing frictional force generated in a valve body. And so, it is believed that more margin can be secured when evaluating the capacity of valve actuator by applying the accurate frictional force generated in the valve assembly.
background: The prognosis after an aortic valve replacment can be affected significantly by the transprosthetic pressure gradient which is determined mainly by the size of the patients body and the prosthesis used. We analyzed the hemodynamic feature of two relatively new prosthese the ATS and the evensized Medtronic-Hall(M-H) valves by measuring the transprosthetic pressure gradient in the cases where small sizes (23mm or smaller) were used. Material and method: There were 94 patients who received whom aortic valve replacement with prosthesis smaller than 23 mm from October 1994 to June 1998. In these patients the transprosthetic pressure gradient clalculated from the pressure half time during postoperative Dopper echocardiographic examination was compared between the prostheses of different sizes. The body surface area of each patient was also taken into consideration. result: The mean pressure gradient and body surface area in each group were 21.7$\pm$10.2 mmHg and 1.52$\pm$0.14m2 in ATS 19mm 11.4$\pm$6.5 mmHg and 1,57$\pm$0.20m2 in M-H 20mm 15.2$\pm$6.3 mmHg and 1.54$\pm$0.13m2 in ATS 21mm 9.3$\pm$2.5 mmHg and 1.63 $\pm$0.14m2 in M-H 22 mm and 12.9$\pm$5.3 mmHg and 1.69$\pm$0.13m2 in ATS 23mm. Conclusion: The 19mm ATS prosthesis showed significant trasprosthetic pressure gradient which is similar to the values previously reported with other bileaflet prosthesesm Close follow-up was needed in terms of exercise capacity and change in left ventiricular geometry. In patients with small aortic valve annulus the 20mm M-H valve is recomendable as an alternative to 19mm bileaflet valves because it has less pressure gradient with similar outer diameter.
EPRI PPM (Performance Prediction Methodology), a method used for the prediction of required thrust of valves, can not be applied to unbalanced-disk globe valves operated in the fluid when the fluid temperature is above $150^{\circ}F$ because the thrust increase caused by the friction between the valve disk and body is not considered in the PPM. In order to apply PPM to the valves, EPRI suggested new friction prediction method to be added in the code. This paper analyzes the applicability of the prediction method comparing the disk-to-body friction load predicted from the method with the measured friction load from the field tests. The maximum values from the prediction method and those obtained from the test were 268lbs and about 1500lbs, respectively. It is included that the prediction method should be improved for the realistic prediction of disk-to-body friction load.
Yang S.M.;Hong S.D.;Song D.S.;Park J.K.;Shin S.K.;Lee H.Y.;Yang S.B.
Proceedings of the Korean Society of Precision Engineering Conference
/
2005.06a
/
pp.1766-1769
/
2005
Air-operated valve(AOV) is one of principal valves that are using to control fluid flow in nuclear power plants. AOV is suffered from damage and malfunction by the abrasion, corrosion and vibration of valve parts under the long time operation. This mechanical trouble and malfunction of valve is critical for the safety of power plant. So a periodic diagnosis for safety of power plants is inevitable to guarantee the safety of the power plant. But depending on the type of the actuator and valve body, various types of AOV exist. In this study, It is developed the diagnostic system that users of power plants are easy to handle in this paper.
From Aug. 1984 to May 1986, 116 cases of cardiovascular surgery including 85 cases of open heart surgery were performed at Korea Veterans Hospital. There were 108 congenital anomalies and 8 acquired valvular heart diseases. Among 108 congenital malformations 92 operations were done for acyanotic group, and 16 operations for cyanotic group. Thirteen cases of open heart surgery for infants or small children under 10kg of body weight were performed, which occupied 15.3 percent of total open heart surgery done in the same period. Common congenital cardiovascular anomalies were ventricular septal defect [40.7%], patent ductus arteriosus [29.6%], tetralogy of Fallot [12.[%], atrial septal defect [11.1%], and pulmonary stenosis [1.9%] in order of frequency. Valve replacement using lonescu-Shiley or Carpentier-Edwards valve was performed for 8 cases of acquired mitral valve disease, and valve replacement using St. Jude valve was done for a case of patent ductus arteriosus with severe mitral insufficiency. There was no mortality in acyanotic congenital malformations and acquired valve lesions, and 5 cases of mortality in cyanotic congenital malformations. Overall mortality was 4.3 percent for total cases and 5.9 percent for 85 cases of open heart surgery.
Journal of the Korean Society of Manufacturing Process Engineers
/
v.4
no.4
/
pp.39-47
/
2005
In this paper, a novel high power micropump using active check valves in place of conventional passive check valves employed at the inlet and outlet ports is presented. It actively controls open/close motion of check valves using piezoelectric actuator for expansion/contraction of pump chamber. A prototype micropump having an effective size of $17mm{\times}8mm{\times}11mm$ is fabricated. Frequency-dependent flow rate characteristics, bi-directional flow characteristics and load characteristics are experimentally investigated using a timing control method for valve closing motion. From the obtained experimental results, it is ascertained that optimal values of the phase shift compared to the voltage to drive pump chamber are $15^{\circ}$ for inlet check valve and $195^{\circ}$ for outlet. Based on the obtained results, a sheet-type active shuttle valve that has a unified valve-body for inlet and outlet check valves is proposed. A micropump with an effective size of $10mm{\times}10mm{\times}10mm$ is fabricated and the basic characteristics are experimentally investigated.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.