• Title/Summary/Keyword: Valve-body

Search Result 237, Processing Time 0.029 seconds

A Method for Estimating Fluid Force in Proportional Directional Control Valves with Spool (스풀형 비례 방향/유량제어밸브의 유체력 검증법)

  • Lee, I.Y.;Son, J.M.;Shin, H.B.;Son, J.H.
    • 유공압시스템학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.109-115
    • /
    • 2010
  • In establishing a simulation program for hydraulic valves, it is always a big obstacle to incorporate correctly flow forces on valve body into the simulation program. This paper suggests a method to estimate flow forces on spool in proportional directional/flow control valves with spool structure. Furthermore, suggests a way to obtain simulation program for spool valves, in which flow force mechanism is fully reflected.

  • PDF

Structure Improvement of Preaction Valve to Reduce the Pressure Drop (압력손실을 줄이기 위한 준비작동식 유수검지장치 본체 구조 개선)

  • Hong, Seung-Tae;Jeong, Jae-Han;Nam, Jun-Seok;Kwon, Young-Kyu;Han, Chul-Su;Yoo, Seung-Joon
    • Korean Chemical Engineering Research
    • /
    • v.53 no.1
    • /
    • pp.16-21
    • /
    • 2015
  • The body structure of diaphragm type preaction valve was improved in order to reduce the pressure drop. The pressure drop must be kept within 20.7 kPa to pass the revised (2012. 2. 9) standard for alarm valve and preaction valve. The pressure drop test was carried out by KFI (Korea Fire Institute) standard. The pressure drop of a preaction valve was higher than that of an alarm valve. Causes for increasing the pressure drop were investigated with the fluid flow in the valve. The preaction valve had more pressure drop factors (changes in velocity and direction) compared with the alarm valve. Inner structure of the preaction valve was changed to the clapper type to remove the pressure drop factors. In 80A and 100A size of preaction valves, the pressure drop was reduced from 80.9 and 171.0 kPa to 14.4 and 14.2 kPa respectively, after the change of the structure.

A Study on the Application Method of Cold & Hot Water Manifold System for Hot Water Supply System in Residential Buildings (주거건물의 급탕방식별 급수.급탕헤더시스템 적용방안에 관한 연구)

  • Cha, Min-Chul;Je, Sung-Ho;Seok, Ho-Tae
    • Journal of the Korean housing association
    • /
    • v.19 no.1
    • /
    • pp.79-88
    • /
    • 2008
  • Hot water is used by having a wash, dishes, taking tub and drinking water in residential buildings, and the use objective is to raise comfort of human body sense, washing and sterilization effect and so on. Cold & hot water supply system is understanded simpler than HVAC systems relatively, so it is true that pace of performance improvement is slower than other systems for plan and technical development. In this study, the performance evaluations are conducted under the condition of composition ratio by 1:1 for cold & hot water supply manifold system using functionally complex valves such as constant flow regulating valve and 3-way mixing valve in the area of $105.6m^2$ apartment which consist of the largest part of the whole apartment. Also, flow rate related to simultaneous use of faucets and change of hot water temperature are compared with the existing method.

Surgical Correction of Discrete Membranous Suaorti Stenosis (선천성 대동맥판막하 막상협착증 치험 2례)

  • 송인기
    • Journal of Chest Surgery
    • /
    • v.23 no.3
    • /
    • pp.532-536
    • /
    • 1990
  • We experienced surgical correction of 2 cases of discrete membranous subaortic stenosis. Case 1 was 19 years old male patient. His complaints were fatigue, exertional dyspnea, syncope and angina for 8 years. Ejection. systolic murmur was heard at the second right intercostal space and diastolic murmur was heard at the apex. A thrill was palpated over the second right intercostal space and area of the carotid artery. 2-D echo, cardiac cath and left ventriculogram revealed discrete membranous subaortic stenosis and VSD. Complete excision of discrete membrane without mymectomy was done. VSD was closed with dacron patch and aortic valve was replaced with St. Jude medical valve. Case 11 was 16 years old female whose complaints were exertional dyspnea and syncope. Ejection systolic murmur was heard at second right intercostal space, but diastolic murmur was not heard. A thrill was palpated over the second right intercostal space and the area of carotid artery. 2-D echo, cardiac cath and left ventriculogram revealed discrete membranous subaortic stenosis. Complete excision of fibrous tissue and myotomy were made and aortic valve was replaced with St. Jude medical valve. Operative finding was followed: both aortic valves showed deformity of leaflets. Subaortic region had a thickened central fibrous body from which the ridge protruded. Both patient`s postoperative course were uneventful and short-term follow-up results were good except soft systolic murmur at the aortic area.

  • PDF

A study on the condition assessment of large diameter water valves using non-destructive technologies (비파괴 기술을 이용한 대구경 수도용 밸브의 상태평가에 관한 연구)

  • Ho-Min Lee;Hyun-yong Choi;Suwan Park;Tae-min Oh;Chae-Min Kim;Cheol-Ho Bae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.37 no.4
    • /
    • pp.215-229
    • /
    • 2023
  • In this study, non-destructive technologies that can be applied to evaluate the integrity of valve materials, safety against internal pressure caused by corrosion, and the blocking function of large-diameter water valves during operation without requiring specimen collection or manpower entering the inside of the valve were tested to assess the reliability of the technologies and their suitability for field application. The results showed that the condition of the graphite structure inside the valve body can be evaluated directly through the optical microscope in the field without specimen collection for large-diameter water butterfly valves, and the depth of corrosion inside the valve body can be determined by array ultrasound and the tensile strength can be measured by instrumented indentation test. The reliability of each of these non-destructive techniques is high, and they can be widely used to evaluate the condition of steel or cast iron pipes that are significantly smaller in thickness than valves. Evaluation of blocking function of the valves with mixed gas showed that it can be detected even when a very low flow rate of mixed gas passes through the disk along with the water flow. Finally, as a result of evaluating the field applicability of non-destructive technologies for three old butterfly valves installed in the US industrial water pipeline, it was found that it is possible to check the material and determine the suitability of large-diameter water valves without taking samples, and to determine the corrosion state and mechanical strength. In addition, it was possible to evaluate safety through the measurement results, and it is judged that the evaluation of the blocking function using mixed gas will help strengthen preventive response in the event of an accident.

Optimal Tricuspid Annular Size for Tricuspid Annuloplasty in Patients with Less-Than-Moderate Functional Tricuspid Regurgitation

  • Choi, Jae Woong;Kim, Kyung Hwan;Lim, Su Chan;Kim, Sue Hyun;Sohn, Suk Ho;Lee, Yeiwon;Hwang, Ho Young
    • Journal of Chest Surgery
    • /
    • v.53 no.6
    • /
    • pp.325-331
    • /
    • 2020
  • Background: We evaluated the association between tricuspid annular dilatation and the development of moderate or severe tricuspid regurgitation (TR). Additionally, we determined the optimal tricuspid annular dilatation threshold to use as an indicator for tricuspid annuloplasty in patients with less-than-moderate functional TR (FTR). Methods: Between August 2007 and December 2014, 227 patients with less-than-moderate TR underwent mitral valve surgery without a tricuspid valve (TV) procedure. The TV annular diameter was measured via transthoracic echocardiography. The TV annular index (TVAI) was calculated as the TV annular diameter divided by the body surface area. The mean duration of echocardiographic follow-up was 42.0 months (interquartile range, 9.3-66.6 months). Results: Eight patients (3.5%) developed moderate or severe TR. The rate of freedom from development of moderate or severe TR at 5 years was 96.2%. TV annular diameter, left atrial diameter, preoperative atrial fibrillation, and TVAI were found to be associated with the development of moderate or severe TR in the univariate analysis. A cut-off TVAI value of 19.8 mm/㎡ was found to predict the development of moderate or severe TR, and a significant difference was observed in the development of TR of this severity based on this cut-off (p<0.001). Conclusion: The progression of TR was not infrequent in patients with untreated lessthan-moderate FTR. An aggressive treatment approach can be helpful to prevent the progression of FTR for patients with risk factors, especially TVAI greater than 19.8 mm/㎡.

Development of Life Test Equipment with Real Time Monitoring System for Butterfly Valves

  • Lee, Gi-Chun;Choi, Byung-Oh;Lee, Young-Bum;Park, Jong-Won;Nam, Tae-Yeon;Song, Keun-Won
    • International Journal of Fluid Machinery and Systems
    • /
    • v.10 no.1
    • /
    • pp.40-46
    • /
    • 2017
  • Small valves including ball valves, gate valves and butterfly valves have been adopted in the fields of steam power generation, petrochemical industry, carriers, and oil tankers. Butterfly valves have normally been applied to fields where in narrow places installing the existing valves such as gate valves and ball valves have proven difficult due to the surrounding area and the heavier of these valves. Butterfly valves are used to control the mass flow of the piping system under low pressure by rotating the circular disk installed inside. The butterfly valve is benefitted by having simpler structure in which the flow is controlled by rotating the disc circular plate along the center axis, whereas the weight of the valve is light compared to the gate valve and ball valve above-mentioned, as there is no additional bracket supporting the valve body. The manufacturing company needs to acquire the performance and life test equipment, in the case of adopting the improving factors to detect leakage and damage on the seat of the valve disc. However, small companies, which are manufacturing the industrial valves, normally sell their products without the life test, which is the reliability test and environment test, because of financial and manpower problems. Furthermore, the failure mode analysis of the products failed in the field is likewise problematic as there is no system collecting the failure data on sites for analyzing the failures of valves. The analyzing and researching process is not arranged systematically because of the financial problem. Therefore this study firstly tried to obtain information about the failure data from the sites, analyzed the failure mode based on the field data collected from the customers, and then obtained field data using measuring equipment. Secondly, we designed and manufactured the performance and life test equipment which also have the real time monitoring system with the naked eye for the butterfly valves. The concept of this equipment can also be adopted by other valves, such as the ball valve, gate valve, and various others. It can be applied to variously sized valves, ranging from 25 mm to large sized valves exceeding 3000 mm. Finally, this study carries out the life test with square wave pressure, using performance and life test equipment. The performance found out that the failures from the real time monitoring system were good. The results of this study can be expanded to the other valves like ball valves, gate valves, and control valves to find out the failure mode using the real time monitoring system for durability and performance tests.