• Title/Summary/Keyword: Valve rotation

Search Result 48, Processing Time 0.027 seconds

An Analytical Study on the Improvement of the Performance of Swivel Valve Tube Couplers (스위벨 밸브 튜브 커플러 개발을 위한 해석 연구)

  • Lee, Jun-Ho;Sung, Jae-Kyeong
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.3
    • /
    • pp.1-6
    • /
    • 2011
  • This study focused on the localization of swivel type tube couplers, which all depend on imports. In this study, a computer application analysis was performed using a finite element method as a preliminary study. In the major developments related to the objective of this study, the air brake system produced by car makers represents a different in the installation point of an air tank according to the type of cars or in the length and direction of its hoses and that leads to cause lots of problems. For solving such problems, the design of the major elements in a swivel type tube coupler was analyzed using a finite element method, and its validity was also verified. In the process that verifies the validity of this study, it was necessary to investigate how much external force affects the desorption of the tube support, which is the most important element in swivel type tube couplers. For achieving the investigation, a pressure test was implemented for the tube support according to the Federal Motor Vehicle Safety Standards(FMVSS). In the results of the pressure test, all samples satisfied the FMVSS. In addition, several tests were implemented by installing the sample of the developed swivel type tube coupler to an actual vehicle. In particular, rotation tests with various angles were applied by welding the swivel type coupler to an air tank through an argon welding process. In the results of the installing test for an actual vehicle, it was verified that the designed structure was determined as a structure that is able to endure the eccentric torque and deformation pressure applied to several directions that are the major problems in such fixed type tube couplers. Therefore, in the comparison of the performance of the developed product with the product of PARKER, it was possible to verify that the localized swivel type tube coupler developed in this study shows more excellent than that of the existing products by PARKER.

Centrifugal Modelling on the Displacement Mode of Unpropped Diaphragm Wall with Surcharge (과재하중이 있는 Unpropped Diaphragm Wall의 변위양상에 관한 원심모델링)

  • 허열;이처근;안광국
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.8
    • /
    • pp.135-145
    • /
    • 2004
  • In this study, the behavior of unpropped diaphragm walls on decomposed granite soil was investigated through centrifugal and numerical modelling. Centrifuge model tests were performed by changing the interval distance of surcharge. Excavation was simulated during the centrifuge tests by operating a solenoid valve that allowed the zinc chloride solution to drain from the excavation. In these tests, ground deformation, wall displacement and bending moment induced by excavation were measured. FLAC program which can be able to apply far most geotechnical problems was used in the numerical analysis. In numerical simulation, Mohr-Coulomb model fur the ground model, an elastic model for diaphragm wall were used for two dimensional plane strain condition. From the results of model tests, failure surface was straight line type, the ground of retained side inside failure line had downward displacement to the direction of the wall, and finally the failure was made by the rotation of the wall. The angle of failure line was about 67 ∼ 74$^{\circ}$, greater than calculated value. The locations of the maximum ground settlement obtained from model tests and analysis results are in good agreements. The displacement of wall and the change of the embedment depth is likely to have linear relationship.

Development of a PCS Simulator and Data Storage System for Energy Saving in the Ship (선박 에너지 절감을 위한 PCS 시뮬레이터 및 데이터 저장 시스템 개발)

  • Oh, Jin-Seok;Kang, Young-Min
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.9
    • /
    • pp.2189-2196
    • /
    • 2015
  • According to increase environmental pollutions and fuel costs, The study of energy saving in the ship is proceeding actively. PCS is pump control system for cooling system in the ship to improve the energy efficiency by controling rotation speed of sea water pump, fresh water pump and position of 3way valve. In this paper, we develop the PCS simulator that has an environment similar to the cooling system of the actual vessel to ensure reliability of the PCS. Also, PC-based control and data storage system for PCS simulator is developed. To develop this system, National Instrument's cDAQ and LabVIEW are used. Finally, confirm the behavior of the simulator by analyzing the saving data.

Design of variable 4-bar linkage structure for adjustable driving angle (구동 각도 조절이 가능한 가변형 4절링크 설계)

  • Kim, Sang-Hyun
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.5
    • /
    • pp.591-596
    • /
    • 2022
  • Since 4-bar linkage widely used in various industrial fields has a fixed link length, it is inconvenient to add an independent link structure or control device to change the movement of output link. Therefore, this paper proposes a new concept of variable 4-bar linkage mechanism to selectively adjust the movement of the output link to fit desired situations, and applied to the commercial table fans, which is a representative product using a 4-bar linkage system. The optimal rotation angle steps for efficiency are determined experimentally and the appropriate lengths of linkage to fit each step are calculated analytically. Changes in the linkage length are implemented by the rotational motion using a grooved cylindrical cam and the feasibility of the proposed variable linkage mechanism is verified through fabrication and measurement. The presented variable link mechanism is expected to improve the efficiency of industrial robots and fuel valve systems.

Experimental Study of Adoption of Alternative Refrigerant for Avionic Equipment Cooling System (항공전자기기용 냉각시스템의 대체냉매 적용에 관한 실험적 연구)

  • Kang, Hoon;Jung, Jongho;Jung, Minwoo;Chi, Yongnam;Yoo, Yongseon;Choi, Heeju;Byeon, Youngman;Kim, Youngjin;Oh, Kwangyoon;Kim, Yongchan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.5
    • /
    • pp.431-439
    • /
    • 2013
  • A cooling system is adopted to control the thermal load from the avionic equipments in an aircraft for stable operation. In this study, an avionic cooling system was designed and manufactured by adopting a vapor compression cycle with a closed-loop air-circulation system to investigate the operating characteristics of an alternative refrigerant. The performance characteristics of a cooling system adopting R236fa as an alternative refrigerant were experimentally determined by varying the refrigerant charging amount, expansion valve opening, and compressor rotation speed. The experimental results were analyzed and compared with those of a cooling system adopting R124 as a refrigerant. The possibility of the adoption of R236fa as an alternative refrigerant was verified, and design solutions were suggested to improve the system efficiency.

Treament of Sternal Dehiscence or Infection Using Muscle Flaps (근육편을 이용한 흉골열개 및 감염의 치료)

  • 최종범;이삼윤;박권재
    • Journal of Chest Surgery
    • /
    • v.34 no.11
    • /
    • pp.848-853
    • /
    • 2001
  • Background: Sternal infection or dehiscence after cardiac surgery through median sternotomy is rare. If suitable treatment is not performed for the complication, however, the mortality is high. For 12 patients with sternal dehiscence or infection, we performed wide excision of the infected and necrotic tissue and covered with muscle flap(s) to obliterate the mediastinal dead space. Material and method: Sternal infection or dehiscence occurred in 13 of patients who underwent cardiac surgery One patient, who died of cerebral infarction before the sternal complication was treated, was excluded in this study. The sternal wound complication occurred in 6 of patients with valve replacement and 6 of patients with coronary bypass surgery, respectively. Since 1991, 9 patients underwent definite surgical debridement and muscle transposition as soon as fever was controlled with closed irrigation and drainage. The necrotic tissue and bone was widely excised and the sternal dead space was eradicated with the single flap or the combined flaps of right pectoralis flap(turnover flap), left pectoralis flap(turnover flap or rotation-advancement flap), and right rectus muscle flap. Result : There was no mortality in 12 patients with coverage of muscle flap(s) for sternal infection or dehiscence The mean interval between the diagnosis of sternal complication and the myoplasty was 6.6$\pm$3.9 days. In 4 patients, one pectoralis muscle flap was used, and in 8 patients both pectoralis muscle flaps were used. For each 1 patient and 2 patients in each group, right rectus muscle flap was added. For the last 3 patients, a single pectoralis flap was used to eradicate the mediastinal dead space and the longer placement of the mediastinal drain catheter was needed. One patient, who had suffered from necrosis of left pectoralis flap(rotation-advancement flap) with subsequent chest wall abscess after coverage of both pectoralis flaps, was managed with reoperation using right rectum flap. Conclusion : Sternal dehiscence or infection after cardiac operation can be readily managed with wide excision of necrotic infected tissue(including bone) and muscle flap coverage after short-term irrigation of sternal wound. The sternal(mediastinal) dead space may be completely eradicated with right pectoralis major muscle flap alone.

  • PDF

Application of Radiological Study by Small Bowel Disease - Comparison of Diagnostic Results of Small Bowel Series and Abdominal Pelvic Computed Tomography - (소장 질환별 방사선학적 검사의 적용에 관한 연구 - 소장조영술과 복부골반전산화단층촬영의 결과 분석을 중심으로 -)

  • Lee, Hee-Jung;Son, Soon-Yong;Lee, Won-Hong
    • Journal of radiological science and technology
    • /
    • v.28 no.4
    • /
    • pp.279-286
    • /
    • 2005
  • Purpose : There are two modalities, those are small bowel series(SBS) and abdominal pelvic computed tomography(CT), for diagnosis of small bowel disease. The aim of this study is to lend radiological technologists who are doing the two modalities assistance in the understanding characteristic of disease by comparing the two results. Meterials and method : 284 patients were examined the two SBS and abdominal pelvic CT together from 1999 to 2003. 250 ml $BaSO_4$ suspension 40 w/v% and 600ml carboxy methyl cellulose 0.5 w/v% were used for SBS. Abdominal Pelvic CT was examined in one hour before taking 450 ml $BaSO_4$ suspension 1.5 w/v%. The CT scan was done in 72 sec after 150 ml contrast media injection. the used protocol was helical mode 5:5 mm pitch 1.375:1, speed 27.50, exposure 120 kv, 240 mA, tube rotation time 0.5 sec. the statistic analysis was conducted with statistical program SPSS 10 version with frequency and crossing analysis. P-value less than 0.05 were considered significant. Results : In the results of SBS, normal findings were 131 patients(46.1%), inflammatory bowel disease(IBD) 64(22.9%), ischemia+ileocolitis+vasculitis 22(7.7%), Obstruction+stricture 21(7.7%) and Others 45(15.9%). In the results of abdominal pelvic CT, normal findings were 103 patients(36.3%), inflammatory bowel disease 65(22.9%), wall thickening+lymphadenopathy 42(14.8%), Fluid collection 17(6%), and Others 57case(20%). The same results of the two were 130patients(45.8%). 30patients(10.6%) of normal finding in SBS were diagnosed as wall thickening+lymphadenopathy and IBD in CT, and 15patients(5.3%) of normal finding in CT were diagnosed as ischemia+ileocolitis+vasculitis, mass and IBD in SBS(p<0.05). Transit time delay was diagnosed in 10patients(3.5%) on only SBS, wall thickening+lymphadenopathy was diagnosed in 20patients(7%) in only CT(p<0.05). Conclusion : We think that proper examination method will be selected in the small bowel disease, if we understand the characteristics of the disease and method.

  • PDF

An Optimization Method of Measuring Heart Position in Dynamic Myocardial Perfusion SPECT with a CZT-based camera (동적 심근관류 SPECT에서 심장의 위치 측정방법에 대한 고찰)

  • Seong, Ji Hye;Lee, Dong Hun;Kim, Eun Hye;Jung, Woo Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.75-79
    • /
    • 2019
  • Purpose Cadmium-zinc-telluride (CZT) camera with semiconductor detector is capable of dynamic myocardial perfusion SPECT for coronary flow reserve (CFR). Image acquisition with the heart positioned within 2 cm in the center of the quality field of view (QFOV) is recommended because the CZT detector based on focused multi-pinhole collimators and is stationary gantry without rotation. The aim of this study was to investigate the optimal method for measuring position of the heart within the center of the QFOV when performing dynamic myocardial perfusion SPECT with the Discovery NM 530c camera. Materials and Methods From June to September 2018, 45 patients were subject to dynamic myocardial perfusion SPECT with D530c. For accurate heart positioning, the patient's heart was scanned with a mobile ultrasound and marked at the top of the probe where the mitral valve (MV) was visible in the parasternal long-axis view (PLAX). And, the marked point on the patient's body matched with the reference point indicated CZT detector in dynamic stress. The heart was positioned to be in the center of the QFOV in rest. The coordinates of dynamic stress and rest were compared statistically. Results The coordinates of the dynamic stress using mobile ultrasound and those taken of the rest were recorded for comparative analysis with regard to the position of the couch and analyzed. There were no statistically significant differences in the coordinates of Table in & out, Table up & down, and Detector in & out (P > 0.05). The difference in distance between the 2 groups was measured at $0.25{\pm}1.00$, $0.24{\pm}0.96$ and $0.25{\pm}0.82cm$ respectively, with no difference greater than 2 cm in all categories. Conclusion The position of the heart taken using mobile ultrasound did not differ significantly from that of the center of the QFOV. Therefore, The use of mobile ultrasound in dynamic stress will help to select the correct position of the heart, which will be effective in clinical diagnosis by minimizing the image quality improvement and the patient's exposure to radiation.