• Title/Summary/Keyword: Valve plate

Search Result 173, Processing Time 0.023 seconds

Comparison of Dynamic Operation Performance of LNG Reliquefaction Processes based on Reverse Brayton Cycle and Claude Cycle (Reverse Brayton 사이클과 Claude 사이클 기반 LNG 재액화 공정의 동특성 운전성능 비교)

  • Shin, Young-Gy;Seo, Jung-A;Lee, Yoon-Pyo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.12
    • /
    • pp.775-780
    • /
    • 2008
  • A dynamic model to simulate LNG reliquefaction process has been developed. The model was applied to two candidate cycles for LNG reliquefaction process, which are Reverse Brayton and Claude cycles. The simulation was intended to simulate the pilot plant under construction for operation of the two cycles and evaluate their feasibility. According to the simulation results, both satisfy control requirements for safe operation of brazed aluminum plate-fin type heat exchangers. In view of energy consumption, the Reverse Brayton cycle is more efficient than the Claude cycle. The latter has an expansion valve in addition to the common facilities sharing with the Reverse Brayton cycle. The expansion valve is a main cause to the efficiency loss. It generates a significant amount of entropy associated with its throttling and increases circulation flow rates of the refrigerant and power consumption caused by its leaking resulting in lowered pressure ratio. It is concluded that the Reverse Brayton cycle is more efficient and simpler in control and construction than the Claude cycle.

Comparison of Operation Performance of LNG Reliquefaction Process according to Reverse Brayton Cycle and Claude Cycle

  • Shin, Young-Gy;Seo, Jung-A;Lee, Yoon-Pyo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.17 no.4
    • /
    • pp.135-140
    • /
    • 2009
  • A dynamic model to simulate LNG reliquefaction process has been developed. The model was applied to two candidate cycles for LNG reliquefaction process, which are Reverse Brayton and Claude cycles. The simulation was intended to simulate the pilot plant under construction for operation of the two cycles and evaluate their feasibility. According to the simulation results, both satisfy control requirements for safe operation of brazed aluminum plate-fin type heat exchangers. In view of energy consumption, the Reverse Brayton cycle is more efficient than the Claude cycle. The latter has an expansion valve in addition to the common facilities sharing with the Reverse Brayton cycle. The expansion valve is a main cause to the efficiency loss. It generates a significant amount of entropy associated with its throttling and increases circulation flow rates of the refrigerant and power consumption caused by its leaking resulting in lowered pressure ratio. It is concluded that the Reverse Brayton cycle is more efficient and simpler in control and construction than the Claude cycle.

Dynamic Performance of Natural Gas Injection Valve for Heavy-Duty CNG Dual Fuel Engine (대형 CNG 혼소 엔진용 천연가스 분사밸브 동특성 연구)

  • Kim, Yong-Rae;Choi, Young
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.5
    • /
    • pp.9-15
    • /
    • 2017
  • Natural gas fuel has known to be very promising in terms of abundancy and economic value. Therefore it is widely treated as research topics in a variety field of production, storage and utilization. Natural gas has become one of the major sources for the power generation by using internal combustion engines(ICE). Development of natural gas fuel injection device should be preceded to realize a reliable natural gas fuel supply system for a MW class power generation reciprocating ICE. In this research, an injection valve which consists of solenoid and body part with a moving plate was designed and its dynamic performance was experimented in the engine-like environment. Displacement length and diameter of an armature and diameter of a solenoid coil were tested at former study. In this research the effect of materials of solenoid core, size of main housing inlet and supply gas pressure are examined.

An Ultrastructural Study on the Glochidium and Glochidial Encystment on the Host Fish (Glochidium larva 의 구조와 숙주어류에서의 피양형태에 관한 미세구조적 연구)

  • Jeong, Kye-Heon
    • The Korean Journal of Malacology
    • /
    • v.5 no.1
    • /
    • pp.1-9
    • /
    • 1989
  • A scanning electron microscopic study on the glochidium and glchidial encystment of Anodonta grandis on the guppy was conducted. The shape of the glochidium is apparently triangular and its averge size is 0.45mm X0.4mm when closed, The two glochidial shell valves are of the same size, kept together by a ligament of 120${\mu}{\textrm}{m}$ in length and 7 ${\mu}{\textrm}{m}$ in width. Each of the glochidial shell valves has a 16 ${\mu}{\textrm}{m}$ long hook sitdded with many spines on the superior face. A large area to the apex of the valve surrounding the base of the hook is provided with numerous small spines which become progressively smaller towards the periphery of the area, The external surface of the glochidial shell valve is covered with numerous small processes showing successive change in the shape and the pattern of destribution by part. Besides the processes, there are a number of niches scattered all over the exterior surface. The glochidial shell valve has two layers. One is the outer thin membrane bearing the processes and the niches and the others is the inner layer bearing numerous holes which any accessory structure and 2.65 ${\mu}{\textrm}{m}$ in diameter, emerges from a canal located at center of ventral plate of the mamtle, A total of three types of the hair cells are observed. In present artificial infection of the glochidium to the guppy, it took about three to four hours to complete an early cysts, During the period of encystment, The epithelial cells of the host fish actively migrated toward the attached glochidium and covered it.

  • PDF

An Experimental Study on Evaporation/Condensation Heat Transfer with Flow Direction in Brazed Plate Heat Exchanger using Refrigerant 410A (R410A를 이용한 브레이징 타입 판형열교환기에서 물 측 유동방향에 따른 응축/증발 성능 평가)

  • Lee, Sung-Woo;Jeong, Young-Man;Lee, Jae-Keun;Lee, Dong-Hyuk
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1096-1101
    • /
    • 2009
  • The plate heat exchanger(PHE) in heat pump has two flow streams of the refrigerant and water. The flow direction of the refrigerant, unlike that of water, can be changed by a 4-way valve depending on operating condition. Therefore the flow arrangement is a parallel flow for heating and a counter flow for cooling, respectively. In this study, the effects of the flow direction of the water on the heat transfer rate are investigated experimentally. The experiments are carried out for brazed plate heat exchangers under a parallel and counter flow conditions in evaporation and condensation. The experimental parameters in this study include the mass flux of the refrigerant 410A from 3 to $14\;kg/m^2s$ and the flow patterns for the pressure of PHE fixed at 0.97 and 2.46 MPa. The results show that both the heat transfer rate and frictional pressure drop across the PHE increase with the mass flux. The heat transfer rate of the refrigerant 410A for evaporation show great sensitivity to flow direction of the water. The heat transfer rate for evaporation with a counter flow are 5-30% higher than that with a parallel flow.

  • PDF

A study on the Architectural Characteristics of Kyungduk-Dan and Manun-Jae in Miryang -Mainly about the Characterics of Traditional Houses in modern era(1876-1945)- (밀양(密陽) 경덕단(景德壇)과 만운재(萬雲齋)의 건축적 특성 - 근대한옥의 성격을 중심으로 -)

  • Lee, Ho-Yeol
    • Journal of architectural history
    • /
    • v.10 no.1 s.25
    • /
    • pp.9-23
    • /
    • 2001
  • This study is for the Kyungduk-Dan(as a altar of Milsung-Daegun) and The Manun-Jae the characteristics(lay out and planning, window patterns, structure, materials) of the the Korean traditional house during the modern era. Before Manun-Jae was used for the house. The Kyungduck-Dan was constructed in August according to the Lunar Calender in 1927. The Manun-Jae(house for Ki-hun Kang, millionaire ) was completed in 1924. Modern Architectures brought to Korea with the bricks, the tiles, the flash doors, the plate grasses, the brass hardwares. These architectural material was used in positive. During the construction of Manun-Jae in 1924, it happened the architectural exchage among a korean, a chinese and a japanese constructor. Though using the air exhaust valve at the kitchen of Ukyung-Kak( old Anchae), it could be assume that the modern convenience and the improvement of residential environments was considered at that period during the construction of Manun-Jae. That construction was elected with the brick($222mm{\times}106mm{\times}50mm$), the chinese colored tile and plate glass such a modem materials. The new shape of the korean lattice window and the wooden flash-door with glass was used. In Ukyung-Kak, the Chan-Maru(service space) and the kitchen such as a service space or concise utility zone was organically connected. Especially, considered the domesitic activity and circulation, the western kitchen sink and the Chan-Maru(service space) was rationally placed. At the Manun-Jae and the Kyungduck-Dan, the architectural characteristic is that the new shape of windows was used. The lattice window at the Ondol room of Ukyung-Kak, was rgadually added the plate glass and the wood plate. The lattice window with the grid shape at kitchen of that building was adapted japanese grid lattice window in korea at that period. It is the sample that korean traditional house was typically influenced from the japanese resident culture. The Manun-Jae and the Kyungduck-Dan as the modern house kept the form of korean traditional architecture, and was partially adapted a modern characteristic space and modern architectural materials. During the japanese occupancy, these residence can be showed the transition in formally.

  • PDF

Analysis of flow rate of variable displacement compressor ECV in automobile air conditioning control system (자동차 공조장치의 가변압축기 ECV 유량 분석)

  • Jeong, Yeong Jun;Cho, Haeng Muk
    • Journal of Energy Engineering
    • /
    • v.22 no.4
    • /
    • pp.394-398
    • /
    • 2013
  • At present, using of electromagnetic control valve (ECV) in external variable displacement swash plate type compressor is a common issue. Solenoid operated ECV controls vehicle air conditioning system through a pulse width modulation (PWM) input signal that supplied from an external source. Different port pressure controls the swash plate movement inside the compressor at certain angles that finally determines the refrigerant flow rate to the vehicle compartment for passengers comfort. In this paper, crankcase pressure flow (Pc flow) is calculated with some ECV samples with corresponding to amount of variable supply of current ranges from 0.20Amp to 0.95Amp.

Development of Independent Sprinkler for Fire Safety (소방안전을 위한 독립 스프링클러 개발)

  • Yun, Hae-Yong;Kim, Seon-Yeop;Kim, Ho-Chan;Park, In-Beck
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.2
    • /
    • pp.124-128
    • /
    • 2017
  • Sprinklers are a necessary device for the early suppression of fires to prevent large fires. The installation has been obligatory for certain buildings recently through the digestion method. In an aging building, it is difficult to find sprinklers, because of their significant cost, long installation times, and they require installation by experts. That is why we are able to install all, was designed with enough independent integrated sprinklers with fire-extinguishing capabilities. The designed sprinklers are fitted with a conventional sprinkler head in a container of 20cm * 20cm * 10cm. Inside the container and potassium carbonate, which warms the rubber material and the plate line by pressing the potassium carbonate, the line weight is a 5kg pressing plate at the entrance at the pressure of 0.5Mpa when operating. The glass sprinkler valve blocking the entrance at about $68^{\circ}C$ is operated open. At this time, the potassium out of the digestive fire to combustible materials and heat off a chain reaction.

Plate Type New Distributor Development for Hydraulic Motors and Pumps (유압모터 및 펌프용 판 형태의 새로운 분배기 개발)

  • Jin, Seong-Mu;Kim, Hyeong-Ui
    • 한국기계연구소 소보
    • /
    • s.18
    • /
    • pp.75-85
    • /
    • 1988
  • The distributor for hydraulic pumps or motors, particularly radial piston motors, include rotary member which has equally both surface shape for dynamic balance and two fixed members, located in both side of rotary member, which have equal surface shape for dynamic balance and circular ring which use to retain predetermined clearance between two fixed members. Rotary member must have valve part for flow-distribution and can have hydrostatic bearing for excellently dynamic balance. At least two annular steps located on said pressure plate which use in compensation of bolt expansion.

  • PDF

Wall Impingement Phenomena of a Fuel Spray Injected by an EFI Injector (EFI 인젝터에 의한 연료분무의 벽면충돌 특성)

  • Kim, Y.I.;ARAI, M.
    • Journal of ILASS-Korea
    • /
    • v.9 no.1
    • /
    • pp.37-42
    • /
    • 2004
  • In a port fuel injection system of engine, a large part of fuel injected into an intake port adheres on its wall and inlet valve. Consequently, the wall impinging spray interaction might occur the generation of several harmful phenomena. There are uncontrollable mixture formation, an accidental backfire and unburned hydrocarbons. Therefore, it is important to analyze the fuel behavior during the spray-wall interaction. In this study, splash characteristics of impingement and reflecting or scattering behavior of droplets of fuel injected from EFI nozzle were studied experimentally. A test fuel used is LAWS and its physical characteristics are similar to the conventional gasoline except for the ignition point. Since the liquid film formed immediately after impinging on an impingement plate is unstable, it is easy to cause secondary disintegration. In addition, when the intermittently impingement on the impingement plate with LAWS, the splash ratio is around 0.6. If an injection period becomes longer, liquid film will become thick and the splash ratio will fall bout 10 percent. On the other hand, when the injection period of an intermittent spray is long, the same time lapse as a continuous spray is shown.

  • PDF