• Title/Summary/Keyword: Valve noise

Search Result 274, Processing Time 0.026 seconds

A Study on the Structural Analysis of Spiral Valve for Cryogenic Linear Expander (극저온 선형 팽창기용 나선형 밸브의 구조 해석에 관한 연구)

  • Yun, So Nam;Kim, Ji U;Yeom, Han Kil;Kim, Hyo Bong
    • Journal of Drive and Control
    • /
    • v.12 no.4
    • /
    • pp.1-7
    • /
    • 2015
  • In this study, a spiral valve which is used with a cryogenic linear expander and composed of plural plate coil shapes was examined. Generally, a spiral valve is well known for having excellent efficiency and low noise characteristics. In order to determine the movement characteristics and to investigate the limit of valve displacement, the stress variations according to the changes of operating pressure, displacement and workable temperature are discussed. From this examination, it is considered that the results of this study will significantly facilitate the design and development of a spiral valve for the cryogenic linear expander.

A study on improving valve train performance by a dynamic model analysis (동적모델 해석에 의한 밸브기구 성능개선에 관한 연구)

  • 전혁수;박윤식
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.6
    • /
    • pp.837-844
    • /
    • 1986
  • Valve motion is one of the most important factors which affect on engine noise and efficiency. Since engine valve train is characterized as a spring-mass system, its dynamic response should be analyzed for varing operation RPM range. In this paper, a OHV type valve train motion was studied by dynamic model analysis. A five degrees of freedom model was set up and simulated for different operating conditions. Also in order to varify the usefulness of the model, the valve displacement and the pushrod force were directly measured for varying RPMs and compared with the simulation results. Then sensitivity analysis was done with the five degrees of freedom model in order to suggest for valve train design change.

Characteristics of Flow Coefficients in an Engine Cylinder Head with a Quasi-steady Flow Condition by Continuous Variation of the Valve Lift (밸브 양정의 연속 변화에 의한 준정상 유동 조건에서의 엔진 실린더헤드 유량계수 특성)

  • Oh, Dae-San;Lee, Choong-Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.6
    • /
    • pp.22-27
    • /
    • 2010
  • Flow Coefficients of intake port in an engine cylinder head were measured by a newly designed flow rig. In measuring the flow coefficient with traditional method, the valve lift was manually varied by technician with adjusting a micrometer which is directly connected to the intake valve of the cylinder head. The cam shaft of the cylinder head is directly rotated by a step motor and the valve lift was automatically varied with cam shaft profile in the newly designed flow rig. The measurement of the flow coefficient was automated by rotating the cam shaft with the step motor. Automatic measurement of the flow coefficient could be safely measured by separating a technician from the noise and vibration of the traditional flow rig. Also, the automatic measurement of the flow coefficient reduce the measurement time and provide meaningful statistical data.

Performance Evaluation of a Semi-active Vehicle Suspension Using Piezostack Actuator Valve (압전작동기 밸브를 이용한 반능동 차량현가장치의 성능 고찰)

  • Han, Chulhee;Yoon, Gun-Ha;Park, Young-Dai;Choi, Seung-Bok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.1
    • /
    • pp.82-88
    • /
    • 2016
  • This paper proposes a new type of semi-active direct-drive valve(DDV) car suspension system using piezoelectric actuator associated with displacement amplifier. As a first step, controllable piezoelectric DDV damper is designed and governing equation of a quarter-vehicle suspension system consisting of sprung mass, spring, tire and the piezostack DDV damper is constructed. After deriving the equations of the motion, in order to control spool displacement and damping force the skyhook controller is designed and applied. The performance evaluation of the proposed semi-active suspension system is conducted with different displacement of spool. Then, the ride comfort analysis is undertaken in time domain with bump road profile.

Examination on High Vibration of Recirculation System for Feed Water Piping in Combined Cycle Power Plant (복합 발전소 주급수 재순환 배관계의 고진동 현상 및 대책)

  • Kim, Yeon-Whan;Kim, Jae-Won;Park, Hyun-Gu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.648-654
    • /
    • 2011
  • The feed-water piping system constitutes a complex flow impedance network incorporating dynamic transfer characteristics which will amplify some pulsation frequencies. Understanding pressure pulsation waves for the feed-water recirculation piping system with cavitation problem of flow control valve is very important to prevent acoustic resonance. Feed water recirculation piping system is excited by potential sources of the shock pulse waves by cavitation of flow control valve. The pulsation becomes the source of structural vibration at the piping system. If it coincides with the natural frequency of the pipe system, excessive vibration results. High-level vibration due to the pressure pulsation affects the reliability of the plant piping system. This paper discusses the piping vibration due to the effect of shock pulsation by the cavitation of the flow control valves for the recirculation piping of feed-water pump system in combined cycle power plants.

  • PDF

A Study on the Nonlinear Behavior of Check Valve System (체크밸브의 비선형거동에 관한 연구)

  • 박철희;홍성철;박창배
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1993.10a
    • /
    • pp.35-41
    • /
    • 1993
  • 산업사회가 발전함에 따라 거대한 플랜트(plant)를 포함하여, 원자력 발전소 와 로켓트 등과 같이 구조적 안전성과 정확한 성능의 확보가 극히 중요시되 는 설비들이 많이 등장하고 있다. 이들 설비를 구성하고 있는 파이프계 (piping system)는 강성 또는 연성재료 및 각종 valve등으로 구성되어 있기 때문에, 고온 고압 고속의 유체가 파이프 내부를 흐를 때 일으키는 진동현상 및 플랜트의 과도운전 상황에서의 일어나는 수격현상(water hammer 또는 steam hammer)과 이로 기인한 제반 진동문제는 안전성확보 측면에서 많은 관심이 고조되고 있다. 이와 관련되어 유체유발진동에 관한 많은 연구들이 수행되었으며, 파이프계에 장착된 밸브에 대한 연구는 Weaver등에 의하여 실험적, 이론적으로 수행되었다. 그들은 유동방정식에서 비정상 베르누이 방 정식을 사용하여 내부유동방정식을 간략하게 유도하였으나, jet flow에 의한 유체의 운동량변화를 고려하지 않고 해석되어 그 결과에 의문이 제기된다. 그러므로 본 연구에서는 체크밸브(check valve)가 부착된 파이프계에서 일어 나는 유체유발진동 및 안정성에 관한 이론적 연구를 수행하여, 파이프계의 설계에 필요한 파라미터의 영향을 파악하고자 한다. 원자력 발전소와 같이 구조적 안정성이 요구되는 플랜트를 국내 기술로 설계 시공하려는 국내 실 정에서 이로 인한 파이프계에 발생할 수 있는 유체유발진동과 안정성을 예 측할 수 있는 해석이론은 파이프계의 설계 및 운전조건의 선정에 있어서 그 의의가 크다고 할 수 있겠다.

  • PDF

Improvement in Image Quality and Visibility of Coronary Arteries, Stents, and Valve Structures on CT Angiography by Deep Learning Reconstruction

  • Chuluunbaatar Otgonbaatar;Jae-Kyun Ryu;Jaemin Shin;Ji Young Woo;Jung Wook Seo;Hackjoon Shim;Dae Hyun Hwang
    • Korean Journal of Radiology
    • /
    • v.23 no.11
    • /
    • pp.1044-1054
    • /
    • 2022
  • Objective: This study aimed to investigate whether a deep learning reconstruction (DLR) method improves the image quality, stent evaluation, and visibility of the valve apparatus in coronary computed tomography angiography (CCTA) when compared with filtered back projection (FBP) and hybrid iterative reconstruction (IR) methods. Materials and Methods: CCTA images of 51 patients (mean age ± standard deviation [SD], 63.9 ± 9.8 years, 36 male) who underwent examination at a single institution were reconstructed using DLR, FBP, and hybrid IR methods and reviewed. CT attenuation, image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and stent evaluation, including 10%-90% edge rise slope (ERS) and 10%-90% edge rise distance (ERD), were measured. Quantitative data are summarized as the mean ± SD. The subjective visual scores (1 for worst -5 for best) of the images were obtained for the following: overall image quality, image noise, and appearance of stent, vessel, and aortic and tricuspid valve apparatus (annulus, leaflets, papillary muscles, and chordae tendineae). These parameters were compared between the DLR, FBP, and hybrid IR methods. Results: DLR provided higher Hounsfield unit (HU) values in the aorta and similar attenuation in the fat and muscle compared with FBP and hybrid IR. The image noise in HU was significantly lower in DLR (12.6 ± 2.2) than in hybrid IR (24.2 ± 3.0) and FBP (54.2 ± 9.5) (p < 0.001). The SNR and CNR were significantly higher in the DLR group than in the FBP and hybrid IR groups (p < 0.001). In the coronary stent, the mean value of ERS was significantly higher in DLR (1260.4 ± 242.5 HU/mm) than that of FBP (801.9 ± 170.7 HU/mm) and hybrid IR (641.9 ± 112.0 HU/mm). The mean value of ERD was measured as 0.8 ± 0.1 mm for DLR while it was 1.1 ± 0.2 mm for FBP and 1.1 ± 0.2 mm for hybrid IR. The subjective visual scores were higher in the DLR than in the images reconstructed with FBP and hybrid IR. Conclusion: DLR reconstruction provided better images than FBP and hybrid IR reconstruction.

Noise Control of an Air Intake system for a Four-Cylinder Engine (4기통 엔진의 흡기계 소음제어)

  • 김태정;홍상범
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.10a
    • /
    • pp.77-83
    • /
    • 1996
  • Noise control process of an air intake system for a four-cylinder automotive engine is described. The objective of the process is reduction of induction noise without losing engine performance and changing package layout. The theory and feasibility for noise control elements are also discussed. In general, four-cylinder engines generate a lower frequency induction noise around 80-150 Hz (2400-4500 rpm) and firing frequency, valve impact noise are the main sources. In this paper, the most problematic noise source is identified first and better position of air inlet is selected between inside-fender and out-of-fender layouts. Secondly, the possible noise control approach and CAE analysis results are compared to those from speaker excitation tests. Finally, the effect of the controlled intake system after the installation to an automobile is presented.

  • PDF

A Study on Outdoor Acoustic Noise for HVDC Converter Station (HVDC 변환소의 옥외소음 분석)

  • Lee, Seong-Doo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.12
    • /
    • pp.91-99
    • /
    • 2010
  • HVDC converter station consists of a number of equipment such as converter transformer, ac filter, thyristor valve and so on. They can be acoustic noise sources. In this paper, we analyzed the simulation results of the outdoor acoustic noise for HVDC converter station. It shows that maximum noise level in boundary of HVDC converter station exceeds regulation value. The main factors in generating maximum noise level are ac filter and converter transformer. Then we applied some soundproof countermeasures in HVDC converter station. Shielding wall is enough to reduce transformer noise level but not enough to reduce ac filter noise level. In case of ac filter, soundproof building is effective in satisfying noise level regulation in boundary of HVDC converter station. In addition, we also studied effects of season, soundproof woods, ground.

Topology Optimization of Muffler Hole of Rotary Compressor using GA (유전자 알고리즘을 이용한 회전식 압축기 머플러 토출구의 위상 최적설계)

  • ;Altay Dikec
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.790-795
    • /
    • 2002
  • The object of this research is limited to the reduction of compression process noise only among the main sources of compressor noise such as motor noise, compression process noise, and valve port flow noise. Thus the research is focused on the wave motion rather than the particle motion of sound wave travels. A muffler is a commonly used device to reduce the compression process noise, generated by the pressure pulsations caused by the cyclic compression process. In this research, the acoustic characteristics of the muffler are analyzed by using the normal gradient integral equation proposed by Wu and Wan. Moreover, a commercial code SYSNOISE developed by indirect variational boundary integral equation is also used to validate the results. For the noise reduction, the topology optimization technique using a genetic algorithm is used. The number, size and position of the muffler holes are considered as design variables. Compared with original design, the optimized design has very improved acoustic characteristics. Both numerical and experimental analyses are used to evaluate new design.

  • PDF