• Title/Summary/Keyword: Valve closure

Search Result 147, Processing Time 0.019 seconds

Numerical Study on the Waterhammer of PalDang Intake Pumping Station (팔당 취수펌프장의 수격현상에 관한 수치해석적 연구)

  • Kim, Kyung-Yup;Yu, Teak-In
    • The KSFM Journal of Fluid Machinery
    • /
    • v.3 no.4 s.9
    • /
    • pp.52-58
    • /
    • 2000
  • The numerical study on the waterhammer was carried out for the intake pumping station of the metropolitan water supply 6th stage project. Because the waterhammer problems as a result of the pump power failure were the most important, these situations were carefully investigated. The surge tank and the stand pipes effectively protected the tunnels md the downstream region of pipeline from the pressure surge. In case the moment of inertia of the pump and motor was above $5080\;kg{\cdot}m^2$, the column separation did not occur in the pipeline between the pumping station and the inlet of 1st tunnel. As the moment of inertia increased, the pressure surges decreased in the pipeline conveying raw water. The pump control valve was chosen as the main surge suppression device for the intake pumping station. After power failure, the valve disc should be rapidly closed in 2.5 seconds and controlled the final closure to 15 seconds by the oil dashpot. If the slamming happened to the pump control valve, there was some danger of this system damaging. As the reverse flow through the valve increased, the upsurge extremely increased.

  • PDF

Dynamic Behavior Analysis of the Heart Valve Prostheses Considering Squeeze Film Effect During Closing Phase (스퀴즈필름효과를 고려한 인공심장밸브의 닫힘시 동적거동 해석)

  • 천길정
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.2
    • /
    • pp.443-450
    • /
    • 1995
  • An analysis of the dynamics of a mechanical monoleaflet heart valve prosthesis in the closing phase is presented. Employing the moment equilibrium principles on the occluder motion and the squeeze film dynamics of the fluid between the occluder and the guiding strut at the instant of impact, the velocity of the occluder tip and the impact force were computed. The dynamics of fluid being squeezed between the occluder and the guiding struts is accounted for by Reynold's equation. The effect of the fluid being squeezed between the occluder and the guiding strut was to reduce the velocity of the occluder tip at the instant of valve closure as well as dampen the fluttering of the occluder before coming to rest in the fully closed position. The squeeze film fluid pressure changed rapidly from a high positive value to a relatively large negative value in less than 1 msec. The results of this study may be extended for the analysis of cavitation inception, mechanical stresses on the formed elements and valve components as well as to estimate the endurance limits of the prosthetic valves.

An Algorithm for Searching On-Off Valves to Isolate a Subsystem in a Water Distribution System (상수관망의 부분적 격리를 위한 제수밸브 탐색 알고리듬)

  • Jun, Hwan Don;Kim, Joong Hoon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.1
    • /
    • pp.35-43
    • /
    • 2006
  • Concerns related to protecting, identifying, and isolating of subsystems of a water distribution network have led to the realization of the increased importance of valves in the system. The most important purpose of valves in water distribution systems is to isolate a subsystem due to breakage, maintenance activities, or contamination. A subsystem called segment is isolated by the closure of adjacent valves. Minimizing the pipe failure impact, an efficient algorithm is required to identify adjacent valves quickly. In this paper, an algorithm to identify adjacent valves to be closed to isolate a subsystem from the remainder of a network when a pipe failure is presented. The algorithm is operated on a matrix called the valve location matrix containing the information of valve locations. An application to an existing water distribution system demonstrates the developed algorithm efficiently locates the adjacent valves for the isolation of a broken pipe.

Left Ventricular Rupture after Mitral Valve Replacement - 3 cases report - (승모판막 치환술후 합병한 좌심실 파열의 외과적 고찰 - 3례 보고 -)

  • 유환국
    • Journal of Chest Surgery
    • /
    • v.23 no.5
    • /
    • pp.987-993
    • /
    • 1990
  • An unusual but often lethal complication of mitral valve replacement is rupture of the left ventricle. From March 1977 through June 1990, 424 mitral valve replacements were performed as isolated or combined procedures. Rupture of the posterior wall of the left ventricle was observed in 3 patients. Their was one type I and two type II rupture. Once the diagnosis was made, all of the patient were connected to the heart-lung machine again and total cardiopulmonary bypass is re-established. Repair was attempted in all of them from the outside of the heart. One of them was successively repaired but two were failed due to myocardial ischemia by circumflex coronary artery injury and failure of adequate closure of the ruptured site. From this results, we concluded that prevention is the best solution. But if we encountered this condition, early diagnosis and rapid treatment may improve the patient`s chances for survival.

  • PDF

Experimental and Numerical Analyses of flow field in a bypass valve (바이패스밸브 유동장에 관한 실험 및 수치해석)

  • Choi, Ji-Yong;Cho, An-Tae;Kim, Kwang-Yong
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.527-530
    • /
    • 2006
  • In the present work, characteristics of the flow in the cage of a steam turbine bypass control valve for thermal power plant are investigated. Experimental measurement for wall static pressure has been carried out to validate numerical solutions. And, the flowfield is analyzed by solving steady three-dimensional Reynolds-averaged Navier-Stokes equations. Shear stress transport (SST) model is used as turbulence closure. The effects of the flow area between stages of the cage on the pressure drop are also found.

  • PDF

Analysis of Flow Field in a Steam Turbine Bypass Valve (증기터빈 바이패스밸브 케이지 유동장 해석관한 연구)

  • Choi Ji-Yong;Cho An-Tai;Kim Kwang-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.9 no.4 s.37
    • /
    • pp.36-42
    • /
    • 2006
  • In the present work, characteristics of the flow in the cage of a steam turbine bypass control valve for thermal power plant are investigated. Experimental measurement for wall static pressure has been carried out to validate numerical solutions. And, the flowfield is analyzed by solving steady three-dimensional Reynolds-averaged Navier-Stokes equations. Shear stress transport (SST) model is used as turbulence closure. The effects of the flow area between stages of the cage on the pressure drop are also found.

Time Course of Ventricular Remodeling after Atrial Septal Defect Closure in Adult Patients

  • Bae, Yo Han;Jang, Woo Sung;Kim, Jin Young;Kim, Yun Seok
    • Journal of Chest Surgery
    • /
    • v.54 no.1
    • /
    • pp.45-52
    • /
    • 2021
  • Background: Atrial septal defect (ASD) is the most common congenital heart disease. However, the details of cardiac chamber remodeling after surgery are not well known, although this is an important issue that should be analyzed to understand long-term outcomes. Methods: Between November 2017 and January 2019, cardiac magnetic resonance imaging was performed preoperatively, at a 1-month postoperative follow-up, and at a 1-year postoperative follow-up. Cardiac chamber volume, valve regurgitation volume, and ejection fraction were measured as functions of time. Results: Thirteen patients (10 men and 3 women) were included. The median age at surgery was 51.4 years. The preoperative median ratio of flow in the pulmonary and systemic circulation was 2.3. The preoperative mean right ventricular (RV) end-diastolic volume index (EDVi) and RV end-systolic volume index (ESVi) had significantly decreased at the 1-month postoperative follow-up (p<0.001, p=0.001, respectively). The decrease in the RVEDVi (p=0.085) and RVESVi (p=0.023) continued until the postoperative 1-year follow-up, although the rate of decrease was slower. Tricuspid valve regurgitation had also decreased at the 1-month postoperative follow-up (p=0.022), and continued to decrease at a reduced rate (p=0.129). Although the RVEDVi and RVESVi improved after ASD closure, the RV volume parameters were still larger than the left ventricular (LV) volume parameters at the 1-year follow-up (RVEDVi vs. LVEDVi: p=0.016; RVESVi vs. LVESVi: p=0.001). Conclusion: Cardiac remodeling after ASD closure is common and mainly occurs in the early postoperative period. However, complete normalization does not occur.

A Study on PIV Measurement of Unsteady Flow around Disk caused by Slide Type Valve Quick Closing (슬라이드 밸브 급폐쇄에 따른 디스크 주위 비정상유동의 PIV계측에 관한 연구)

  • Lee, Chul-Jae;Cho, Dae-Hwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.15 no.3
    • /
    • pp.251-256
    • /
    • 2009
  • In this research, we experimentally studied flow characteristic by applying PIV measuring techniques which could measure the point velocity of all flow field and measuring the unsteady velocity of surrounding disk generated in a short time. Time range of great velocity change following quick closing of the slide valve was within 0.1s and the cycle was presumed to be 0.12s as a result of comparison study between the result of point flow field and of existing pressure change. Also, surrounding disk flow inside the circular pipe was closed from the upper part and flow road was getting narrow and advanced to the lower part incidentally quickly there was a tendency that the size of the flow back velocity to the upper part immeadiately after the closure decreased to 4/120s and increased again. There was flow back velocity component in y/D=0.2 lower part by the influence of flow back to the upper part after complete closure and the vortex flow of 0.2D-size near y/D=0.7, x/D=-0.3 was observed.

  • PDF

Robot-Assisted Cardiac Surgery Using the Da Vinci Surgical System: A Single Center Experience

  • Kim, Eung Re;Lim, Cheong;Kim, Dong Jin;Kim, Jun Sung;Park, Kay Hyun
    • Journal of Chest Surgery
    • /
    • v.48 no.2
    • /
    • pp.99-104
    • /
    • 2015
  • Background: We report our initial experiences of robot-assisted cardiac surgery using the da Vinci Surgical System. Methods: Between February 2010 and March 2014, 50 consecutive patients underwent minimally invasive robot-assisted cardiac surgery. Results: Robot-assisted cardiac surgery was employed in two cases of minimally invasive direct coronary artery bypass, 17 cases of mitral valve repair, 10 cases of cardiac myxoma removal, 20 cases of atrial septal defect repair, and one isolated CryoMaze procedure. Average cardiopulmonary bypass time and average aorta cross-clamping time were $194.8{\pm}48.6$ minutes and $126.1{\pm}22.6$ minutes in mitral valve repair operations and $132.0{\pm}32.0$ minutes and $76.1{\pm}23.1$ minutes in myxoma removal operations, respectively. During atrial septal defect closure operations, the average cardiopulmonary bypass time was $128.3{\pm}43.1$ minutes. The median length of stay was between five and seven days. The only complication was that one patient needed reoperation to address bleeding. There were no hospital mortalities. Conclusion: Robot-assisted cardiac surgery is safe and effective for mitral valve repair, atrial septal defect closure, and cardiac myxoma removal surgery. Reducing operative time depends heavily on the experience of the entire robotic surgical team.

Tricuspid Valve Endocarditis (삼첨판막 심내막염)

  • 문광덕;김대영
    • Journal of Chest Surgery
    • /
    • v.29 no.4
    • /
    • pp.440-443
    • /
    • 1996
  • Some tricuspid valve endocarditis can be controlled effectively with specific antibiotic treatment. However, surgical intervention Is necessary when there are continuing sepsis, moderate or severe heart failure, multiple pulmonary emboli, and echocardiographycally demonstrated vegitations. We are repoting a 19 year-old male patient who was admitted for the treatment of infective endocarditis. He previously had an operation for ventriculer septal defect (perimembranous type) about 9 years ago . An echocardiogram showed a large vegetation on the anterior cusp area and a left to right shunt through VSD, which was previously closed with dacron patch. A valve replacement in addition to antibiotic therapy was recommended for the patient. The patient underwent on operation : tricuspid valve replacement was done with 51. Jude medical valve prosthesis (33 mm), and in addition to above procedure, removal of vegetation and direct closure of VSD were done Postoperative echocardiogram showed that replaced tricuspid valve functioned well and vegeta ion and shunt flow were not observed. The patient recovered without complication and discharged at Postoperative day 25. Early aggressive surgical intervention is indicated to optimize surgical results, and this case seems to be a typical right sided bacterial endocarditis, which is caused by residual VSD. We are reporting a case of tricuspid valve endocarditis with a review of the literature. (Korean J Thorax Cardiovasc Surg 1996 ; 29: 440-3)

  • PDF