• Title/Summary/Keyword: Valve Materials

Search Result 344, Processing Time 0.033 seconds

Early Results of the Arterial Switch Operation in Neonates (신생아에서 동맥전환술의 조기성적)

  • 성시찬;방정희;편승환;전희재;조광조;최필조;우종수;이형두
    • Journal of Chest Surgery
    • /
    • v.31 no.10
    • /
    • pp.931-938
    • /
    • 1998
  • Background: Anatomic correction of transposition of the great arteries by means of the arterial switch operation is now accepted as the therapeutic method of choice. This retrospective study attempts to assess the results of the neonatal arterial switch operation for transposition of the great arteries performed by our newly established institution. Materials and methods: 33 consecutive neonates underwent the arterial switch operation between October 1991 to November 1997. There were 27 neonates with transposition and intact ventricular septum, 3 with ventricular septal defect, and 3 with Taussig-Bing anomaly. The mean age was 10.9$\pm$7.9 days and mean body weight was 3.29$\pm$0.44kg. Results: Overall postoperative hospital mortality was 30.3% (10 patients). The mortality has improved with time; 75% (6 patients) among first 8 consecutive patients before 1994, 20% (2 patients) among 10 patients in 1994 and 1995, and 13.3% (2 patients) among 15 patients since 1996. Univariated analysis of risk factors revealed that earlier date of the operations and one of preoperative events were determinants for operative death. There were two late deaths. A mean follow-up of 17.4$\pm$16.5 months was achieved in all 21 survivors. All were in New York Heart Association functional class I. One patient had mild pulmonary stenosis and two had mild aortic valve regurgitation on their echocardiography. Conclusions: We concluded that we should continue to perform arterial switch operation for neonates with transposition of the great arteries because the mortality of the operation has been improved and the operative survivors have good functional results with low incidence of late complications.

  • PDF

Arthroscopic Direct Removal of Popliteal Cyst by Posteromedial Portal (관절경하 후내측 도달법을 이용한 슬와 낭종의 직접적 제거술)

  • Cho, Jin-Ho;Kim, Yong-Hoon;Kim, Dong-Hwan
    • Journal of the Korean Arthroscopy Society
    • /
    • v.9 no.2
    • /
    • pp.232-237
    • /
    • 2005
  • Purpose: To evaluate the effectiveness of arthroscopic direct cystic removal of popliteal cyst using 70 degree arthroscopy and posteromedial portal. Materials and Methods: From January 2003 to January 2004, 21 patients(23 cases) with popliteal cyst have been treated by direct cystic decompression with arthroscopy. The average age of the 21 patients was 54 years(range 35 to 78 years). There were 5 males and 16 females. Of the 23 cases,8 cases were occured in right side and 11 cases were occured in left side. 4 cases were both sides. In all cases, preoperative MRI were performed to detect combined intraarticular pathology. At 6 months and 1 year postoperatively, follow-up ultrasonography were performed to detect recurrence of cyst. We used Rauschning and Lindgren criteria for clinical evaluation. Results: All cases had no recurrence and no complaints of pain, swelling, or functional impairment at 1 year after surgery. At ultrasonography, no recurrence were founded. One complication was occurred. Postoperatively, Rauschning and Lindgren criteria were more than grade 1. Conclusion: Arthroscopic direct cystic removal using arthroscopy and posteromedial portal is an effective method in popliteal cyst surgery.

  • PDF

Improved Radiochemical Yields, Reliability and Improvement of Domestic $^{18}F$-FDG Auto Synthesizer (국산 $^{18}F$-FDG Auto Sysnthesizer의 수율 향상과 성능 개선)

  • Park, Jun-Hyung;Im, Ki-Seop;Lee, Hong-Jin;Jeong, Kyung-Il;Lee, Byung-Chul;Lee, In-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.147-151
    • /
    • 2009
  • Purpose: 2-[$^{18}F$]Fluoro-2-deoxy-D-glucose ([$^{18}F$]FDG) particularly plays as a important role in Positron Emission Tomography (PET) imaging in nuclear medicine. Domestic [$^{18}F$]FDG auto synthesizers are installed in Seoul National University Bundang Hospital (SNUBH) at June 2008, these modules were known that it's synthetic yields were guaranteed in average $45{\pm}5%$ so far. To improve yields and convenience of domestic [$^{18}F$]FDG auto synthesizer, numerous trials in reaction time, base concentration, pressure and temperature were performed to increase [$^{18}F$]FDG yields. Materials and Methods: Several synthetic factors (temperature, time and pressure) and shortcoming were corrected based on many evaporation test. Syringe dispensing of tetra-butylammonium bicarbonate (TBAB) was replaced with micro pipette to prepare tetrabutyl ammonium fluoride salt ([$^{18}F$]TBAF). Troublesome refill of liquid nitrogen every 2 hours which was used to protect vacuum system was changed to charcoal cartridge, base guard filter. To monitor the volume of delivered $[^{18}O]OH_2$ from cyclotron by surveillance camera, we set up the volumetric vial on the cover of the module. In addition to, the recovery vial was added in [$^{18}F$]FDG production system to recover [$^{18}F$]FDG loss due to the leak of valve ($V_{13,14}$) in [$^{18}F$]FDG purification process. Results: When we used micro pipette for adding TBAB ($30\;{\mu}L$ in 12% $H_2O$ in acetonitrile), this quantitative dispensation has enabled to improve $5.5{\pm}1.7%$ residual fluorine-18 activity in fluorine separation cartridge compared to syringe adding. Besides, the synthetic yields of [$^{18}F$]FDG has increased $58{\pm}2.6%$ (n=19), $58{\pm}2.9%$ (n=14), $60%{\pm}2.5%$ (n=17) for 3 months. The life cycle of charcoal cartridge and base vacuum was 3 months prior to filling liquid nitrogen every 2 hours and additional side separator can prevent pump corrosion by organic solvent. After setting of volumetric indicator vial, the operator can easily monitor the total volume of irradiated $[^{18}O]OH_2$ from cyclotron. The recovery vial can be used for the stabilizer when an irregular [$^{18}F$]FDG loss was generated by the leak of valves ($V_{13,14}$). Conclusions: We has optimized appropriate synthetic conditions (temperature, time, pressure) in domestic [$^{18}F$]FDG auto synthesizer. In addition to, the remodeling with several accessories improve yields of domestic [$^{18}F$]FDG auto synthesizer with reliable reproducibility.

  • PDF

The Follow Up Results of Residual Spinoglenoid Ganglion Cyst after Arthroscopic Decompression and Superior Labral Repair - Cases Report - (극관절와 결절성 낭포의 관절경적 감압술 및 상부관절와순 봉합술 후 잔존 낭포의 경과 - 증례 보고 -)

  • Sung, Chang-Meen;Lee, Sang-Hyuk;Park, Hyung-Bin
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.1
    • /
    • pp.111-116
    • /
    • 2010
  • Purpose: There are many known treatment modalities for spinoglenoid ganglion cyst accompanied by suprascapular nerve palsy. However, to the author's knowledge, there is no report on the follow-up outcomes focused on remnant cysts. Materials and Methods: Six (n=6) patients with spinoglenoid ganglion cyst accompanied by suprascapular nerve palsy, with a mean follow-up of 15 months (12-23months) following arthroscopic cyst decompression and superior labral repair, were enrolled. Residual cyst was investigated by ultrasonography and MRI. Results: Immediate postoperative ultrasonography revealed complete remission of ganglion cyst in one patient and reduced ganglion cyst size in five patients. Three-month follow-up ultrasonography showed spontaneous complete remission of the residual cysts in all patients. No recurrence on MRI was seen at one-year follow-up. Conclusion: Residual spinoglenoid ganglion cyst remaining after arthroscopic decompression and superior labral repair tends to resolve spontaneously within 3 months of surgery.

Automation of Longline -Automation of the Alaska Pollack Longline- (주낙어구의 자동화 -명태주낙어업의 자동화-)

  • KO Kwan-Soh;YOON Gab-Dong;LEE Chun-Woo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.20 no.2
    • /
    • pp.106-113
    • /
    • 1987
  • The Alaska pollack longline operations, which consist of baiting, shooting, hauling and arrangement of hooks, are dependant on manual labour up to the present. The automation against this traditional way is necessary to eliminate the manual operations and to reduce crew. We have developed a prototype longline system suitable for Alaska pollack longline gear, which is composed of an automatic baiting machine, an automatic line hauler, a hook cleaner and storage rails. The automatic bailing machine driven by hydraulic power is precise baiting method controlled sequentially, and the automatic line hauler is to haul up the mainline by means of hydraulic power and at the same time to split every hook and to carry it onto storage rail automatically. A series functioning tests on shooting and hauling apparatus were carried out in the laboratory and at sea. The results obtained are as follows ; 1. As for the baiting machine, the exciting time of solenoid which operates a directional valve, bait feeding and cutting time, is shortened according to the increase of pressure, and also, after cutting the bait, the over-rotated angle of the blade increased in accordance with the increase of pressure. 2. The baiting efficiency is about $90\%$ when using sand lance (Hypoptychus dybowskii), and the most proper pressure of the hydraulic circuit in feeding and cutting the bait is between $13\;kgf/cm^2\;and\;20\;kgf/cm^2$. 3. The hook splitting rate of the automatic line hauler is about $95.5\%$ regardless of hauling speed and materials of snood. 4. The case of unseparating hook is appeared when the snood gets entangled or the hook is sticked in the mainline.

  • PDF

Evaluation about a Usefulness of ECG-Gated Scan on 13N-ammonia PET (13N-ammonia 심장 PET 검사에서 ECG gated scan의 유용성 평가)

  • Kim, Jae-Il;Lee, Hong-Jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.20-23
    • /
    • 2016
  • Purpose Because of heart movement, PET image of heart is very blur. So, PET scan gated with ECG is necessary to improve a spatial resolution of heart PET image. In this study, we will evaluate a image quality of both gated $^{13}N-ammonia$ PET scan and non-gated one. Materials and Methods Before start a heart PET, we attached a ECG electrode on patients (n = 5, $aged=54{\pm}17$). And we started a list mode PET scan that used by a mCT40 PET/CT (siemens, germany) during 10 minute, injected $^{13}N-ammonia$ ($378{\pm}50MBq$) to a patients at same time. By using this list mode data, we reconstructed both gated PET image and non-gated PET image. Then we analysed a profiles of those images, performed a blind test, and subtracted a gated image on non-gated image. Results FWHM of a gated image is improved about 23% and there is a differency count distribution at a subtracted image from non-gated image to a gated image. But in case of blind test, everybody select the gated image as a better quality among each images. Conclusion As a result, we can find that image quality will improve by using gated PET scan. In additional, we can calculate a EF valve, apply QGS, QPS of PET. Therefore, the gated PET scan help improving an accuracy, applying a more information for a diagnosis.

  • PDF

UHV Materials (초고진공계재료)

  • 박동수
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1998.02a
    • /
    • pp.24-24
    • /
    • 1998
  • 반도체장비를 포함하는 초고진공장비의 園훌化가 급속히 그리고 절실히 요구되고 있는 것이 현실정이다. 當面해서 실현할 국산진공장비의 대상은 廣範圍하다. 즉, 각종 진공 pump ( (rotary, dry, diffusion, cryo, ion, turbo melecular pump), 진공 chamber, 진공 line, gate valve 를 위 시 한 진공 V머ve, flange, gasket, fl않d야lU, mainpulater 퉁 진공 部品이 다. 진공계 의 핵심 은 適切하고 優良한 진공재료의 선태파 사용이다. 진공장비는 사용자가 원하는 진공도를 원하 는 시간 동안 륨空度를 유지해 주어야 한다. 진공재료 선태의 기준사항은:(1) 기체의 透過성 (2) 薰했훌 (3) 혔體放出특성 - -outgassing과 degassing- (4) 機械的 량훌度 (5) 온도 의존성 (6) 化學톡성 (7) 加I성 및 鎔接 성 (8) 課電특성 (9) 磁氣특성 (10) 高速함子 및 放射線 특성 (11) 經濟성 및 調達생 둥이 다. 우량한 초고진공계재료는 풍부하게 개발되어 왔고, 또 新材料들이 개발되고 있다. 여기에서는 주로 초고진공 내지는 극고진공계의 構造材料, 機能材料, 部品材料 일반파 몇가지 신재료의 특 성에 관해서 記述한다. M Mild SteeHSAE, 1112, 1010, 1020, 1022, etc)., S Stainless SteeHAlSI, 304, 304L, 310, 316, 321, 347): 구조재료, chamber, fl하1ges A Aluminum과 Alloys (1060, 1100, 2014, 4032, 6(뻐1): 구조재료, chamber, flanges, gaskets A AI, Al 떠loy는 SS에 代替하는 역 할올 시 작하고 있다. C Copper, Copper Alloys(C11$\alpha$)0, C26800, C61400, Cl7200): 내장인자, gasket, cryopanel, tubing T Titanium, Ziriconium, Haf띠um 및 Alloys: 특히 Ti은 10n pump 용 getter material 이 외 에 U UHV,XHV용 chamber계로서 관심올 끌고 있다. N Nickel, Nickel Alloys (200, 204, 211, monel, nichrome): 부식 방지 , 전자장치 , 자기 장치 귀 금속(Ag, Au, Pt, Pd, Rh, Ir, Os, Ru): 보조부품, gasket, filament, coating, thermocouple, 접 합부위 T TiC, SiC, zrC, HfC, TaC 둥의 탄화물과, BN, TiN, AlN 동의 질화물, 붕화물이 둥장하고 었 다. 유리: Soda Lime, Borosilicate, Potash Soda Lead: View Port, Chamber envelope C Ceramics: AlZ03, BeO, MgO, zrOz, SiOz, MgOzSiOz, 3Alz032SiOz, Z$textsc{k}$hSiOz S상N4: e electrical, thermal insulators, crucibles, boats, single crystals, sepctr려 windows 저자는 최근 저자들이 발견한 Zr-Ti-Cu-Ni-Be amorphous alloys coated cham뾰r가 radiation p proof로 이용될 수 있는 사실을 점검하고 었다 .. Z.Y. Hua 들은 Cs3Sb를 새로운 photocathode 재료로 보고하고 있다.

  • PDF

Numerical Analysis of Flow Characteristies inside innes part of Fluid Control Valve System (유동해석을 통한 유체제어벨브 시스템의 내부 유동 특성 분석)

  • Son, Chang-Woo;Seo, Tae-Il;Kim, Kwang-Hee;Lee, Sun-Ryong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.160-166
    • /
    • 2018
  • The worldwide semi-conductor market has been growing for a long time. Manufacturing lines of semi-conductors need to handle several types of toxic gases. In particular, they need to be controlled accurately in real time. This type of toxic gas control system consists of many different kinds of parts, e.g., fittings, valves, tubes, filters, and regulators. These parts obviously need to be manufactured precisely and be corrosion resistant because they have to control high pressure gases for long periods without any leakage. For this, surface machining and hardening technologies of the metal block and metal gasket need to be studied. This type of study depends on various factors, such as geometric shapes, part materials, surface hardening method, and gas pressures. This paper presents strong concerns on a series of simulation processes regarding the differences between the inlet and outlet pressures considering several different fluid velocity, tube diameters, and V-angles. Indeed, this study will very helpful to determine the important design factors as well as precisely manufacture these parts. The EP (Electrolytic Polishing) process was used to obtain cleaner surfaces, and hardness tests were carried out after the EP process.

Computed Tomography-Based Ventricular Volumes and Morphometric Parameters for Deciding the Treatment Strategy in Children with a Hypoplastic Left Ventricle: Preliminary Results

  • Goo, Hyun Woo;Park, Sang-Hyub
    • Korean Journal of Radiology
    • /
    • v.19 no.6
    • /
    • pp.1042-1052
    • /
    • 2018
  • Objective: To determine the utility of computed tomography (CT) ventricular volumes and morphometric parameters for deciding the treatment strategy in children with a hypoplastic left ventricle (LV). Materials and Methods: Ninety-four consecutive children were included in this study and divided into small LV single ventricle repair (SVR) (n = 28), small LV biventricular repair (BVR) (n = 6), disease-matched control (n = 19), and control (n = 41) groups. The CT-based indexed LV volumes, LV-to-right-ventricular (LV/RV) volume ratio, left-to-right atrioventricular valve (AVV) area ratio, left-to-right AVV diameter ratio, and LV/RV long dimension ratio were compared between groups. Proportions of preferred SVR in the small LV SVR group suggested by the parameters were evaluated. Results: Indexed LV end-systolic (ES) and end-diastolic (ED) volumes in the small LV SVR group ($6.3{\pm}4.0mL/m^2$ and $14.4{\pm}10.2mL/m^2$, respectively) were significantly smaller than those in the disease-matched control group ($16.0{\pm}4.7mL/m^2$ and $37.7{\pm}12.0mL/m^2$, respectively; p < 0.001) and the control group ($16.0{\pm}5.5mL/m^2$ and $46.3{\pm}10.8mL/m^2$, respectively; p < 0.001). These volumes were $8.3{\pm}2.4mL/m^2$ and $21.4{\pm}5.3mL/m^2$, respectively, in the small LV BVR group. ES and ED indexed LV volumes of < $7mL/m^2$ and < $17mL/m^2$, LV/RV volume ratios of < 0.22 and < 0.25, AVV area ratios of < 0.33 and < 0.24, and AVV diameter ratios of < 0.52 and < 0.46, respectively, enabled the differentiation of a subset of patients in the small LV SVR group from those in the two control groups. One patient in the small LV biventricular group died after BVR, indicating that this patient might not have been a good candidate based on the suggested cut-off values. Conclusion: CT-based ventricular volumes and morphometric parameters can suggest cut-off values for SVR in children with a hypoplastic LV.

Fully Automatic Coronary Calcium Score Software Empowered by Artificial Intelligence Technology: Validation Study Using Three CT Cohorts

  • June-Goo Lee;HeeSoo Kim;Heejun Kang;Hyun Jung Koo;Joon-Won Kang;Young-Hak Kim;Dong Hyun Yang
    • Korean Journal of Radiology
    • /
    • v.22 no.11
    • /
    • pp.1764-1776
    • /
    • 2021
  • Objective: This study aimed to validate a deep learning-based fully automatic calcium scoring (coronary artery calcium [CAC]_auto) system using previously published cardiac computed tomography (CT) cohort data with the manually segmented coronary calcium scoring (CAC_hand) system as the reference standard. Materials and Methods: We developed the CAC_auto system using 100 co-registered, non-enhanced and contrast-enhanced CT scans. For the validation of the CAC_auto system, three previously published CT cohorts (n = 2985) were chosen to represent different clinical scenarios (i.e., 2647 asymptomatic, 220 symptomatic, 118 valve disease) and four CT models. The performance of the CAC_auto system in detecting coronary calcium was determined. The reliability of the system in measuring the Agatston score as compared with CAC_hand was also evaluated per vessel and per patient using intraclass correlation coefficients (ICCs) and Bland-Altman analysis. The agreement between CAC_auto and CAC_hand based on the cardiovascular risk stratification categories (Agatston score: 0, 1-10, 11-100, 101-400, > 400) was evaluated. Results: In 2985 patients, 6218 coronary calcium lesions were identified using CAC_hand. The per-lesion sensitivity and false-positive rate of the CAC_auto system in detecting coronary calcium were 93.3% (5800 of 6218) and 0.11 false-positive lesions per patient, respectively. The CAC_auto system, in measuring the Agatston score, yielded ICCs of 0.99 for all the vessels (left main 0.91, left anterior descending 0.99, left circumflex 0.96, right coronary 0.99). The limits of agreement between CAC_auto and CAC_hand were 1.6 ± 52.2. The linearly weighted kappa value for the Agatston score categorization was 0.94. The main causes of false-positive results were image noise (29.1%, 97/333 lesions), aortic wall calcification (25.5%, 85/333 lesions), and pericardial calcification (24.3%, 81/333 lesions). Conclusion: The atlas-based CAC_auto empowered by deep learning provided accurate calcium score measurement as compared with manual method and risk category classification, which could potentially streamline CAC imaging workflows.