• 제목/요약/키워드: Value Measurement

검색결과 4,756건 처리시간 0.033초

웹페이지를 위한 규모측정에 관한 연구 (An Empirical Study on the Measurement of Size for Web-Page)

  • Kim, In-Suk;Lee, Nam-Yong
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 2003년도 봄 학술발표논문집 Vol.30 No.1 (B)
    • /
    • pp.52-54
    • /
    • 2003
  • Measurement is used to improve software process and to help calculating software quality. It makes software project to be control and help producing software. Measuring software scale becomes important target in software development. LOC is used to measure the size intentioned aspect and function point is used to measure the function intentioned aspect. This paper discusses measurement method using function point, which fullows proposed rule, and degree of GUI (Graphical User Interface) accesses achieved by applying this measurement to web page. Applying proposed rules to web pages (specially that use much GUI such as shopping mall or auction site), there is advantage that calculate site changes on numerical value by measuring GUI degree when do site administration or update.

  • PDF

선박 방사소음의 측정방법 및 정확도 해석 (Ship Radiated Noise Measurement Methods and Accuracy Analysis)

  • 이필호;윤종락
    • 한국소음진동공학회논문집
    • /
    • 제15권6호
    • /
    • pp.738-748
    • /
    • 2005
  • The ship radiated noise level fluctuates by the difference of interference and reverberation according to measurement methods and environmental conditions. These phenomena cause error of the source level estimation even in the same environment conditions. This paper describes a quantitative analysis and a reduction method for an error value to the source level estimation in spatial and temporal interference environment. The design criteria of the radiated noise measurement array composed of omni-directional hydrophones and the source level accuracy in the deep water range are given. The source level accuracy in the shallow water range is also derived based on the statistical model of the multiple reflection paths. The results are verified using the water tank experiment and the sea trial.

하이브리드 로켓 모터에 대한 연소 실험 측정 불확도 (Combustion Experiment Measurement Uncertainty for Hybrid Rocket Motor)

  • 김수종;문희장;김진곤
    • 한국항공운항학회지
    • /
    • 제19권1호
    • /
    • pp.7-14
    • /
    • 2011
  • In this study, the measurement uncertainty of combustion experimental system and experimental parameters for hybrid rocket were evaluated by B type evaluation method. The measurement uncertainty of all experimental parameters was lower than 3%. The highest value of expanded uncertainty was characteristic velocity efficiency with 2.83% and the expanded uncertainty of regression rate which is the design and performance parameter was indicated to 0.03%. These results shown that the reliability of hybrid combustion system was located within allowed limits.

전기수술기 성능시험용 True RMS 측정에 관한 연구 (A Study on the True RMS Measurement of Electrical Unit for Performance Test)

  • 고한우;배문섭;최덕희
    • 대한의용생체공학회:의공학회지
    • /
    • 제12권4호
    • /
    • pp.309-314
    • /
    • 1991
  • This paper describes the results of study on the measurement method of TRMS (true root mean square value) In electrosurgical unit. We used three type (direct computing type, indirect computing type, thermal converting type) in the measurement of TRMS. Three types of measurement method were compared with respect to power level, frequencey and crest factor in addition to environmental temperature. In three of them, the thermal converting type was the best for th electrosurgical unit analyzer

  • PDF

DC링크 전류센서를 이용한 삼상전류 측정 방식에서 최소 스위칭 시간의 단축 (Reduction of Minimum Switching Duration in the Measurement of Three Phase Current with DC-Link Current Sensor)

  • 김경서
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권12호
    • /
    • pp.649-654
    • /
    • 2003
  • The simplest method for measuring output currents of the three phase inverters is to measure them with three current sensors such as hall sensors. This method requires at least two current sensors, and these types of sensors are somewhat expensive. More economical method is measuring DC link current with a simple shunt resistor, then, reconstructing output current using the DC link current value and the switching status. However, in low speed region, the measurement becomes difficult and even impossible due to the requirement of minimum switching duration for A/D conversion. These problems can be overcome by limitation of switching duration. Limitation of switching, however, causes voltage and current distortion. Owing to compensation, distortion can be effectively suppressed. However these increase acoustic noise due to increment of current ripple. In this paper, a current measurement method is proposed, which can reduce minimum switching duration resulting in reduction of acoustic noise. The validity of proposed method is confirmed through experiment.

Power Analysis for Tests Adjusted for Measurement Error

  • 허순영
    • 한국데이터정보과학회:학술대회논문집
    • /
    • 한국데이터정보과학회 2003년도 춘계학술대회
    • /
    • pp.1-14
    • /
    • 2003
  • In man cases, the measurement error variances may be functions of the unknown true values or related covariate. In some cases, the measurement error variances increase in proportion to the value of predictor. This paper develops estimators of the parameters of a linear measurement error variance function under stratified multistage random sampling design and additional conditions. Also, this paper evaluates and compares the power of an asymptotically unbiased test with that of an asymptotically biased test. The proposed method are applied to blood sample measurements from the U.S. Third National Health and Nutrition Examination Survey(NHANES III)

  • PDF

선형변이 차동변압기를 이용한 왕복운동 계측기법 (An Aalternating Motion Measurement Technique Using Linear Variables Differential Transformers)

  • 최주호;유준
    • 제어로봇시스템학회논문지
    • /
    • 제3권5호
    • /
    • pp.455-460
    • /
    • 1997
  • This paper presents a recoil and counter recoil motion measurement method using linear variable differential transformers(LVDT). The output of a LVDT is obtained from the differential voltage of the 2nd transformers. As the sensor core is attached to the motion body, the output is directly proportional to the core motion. Displacement, velocity and acceleration are measured from the core length. A comparison between the measurement result and the known value, which is obtained by the precision steel tape, shows that the accuracy and the usefulness of the proposed scheme is validated.

  • PDF

소음기 감음 성능 불확도 산출 방법 연구 (Application of the uncertainty for insertion loss measurement of silencers)

  • 유승국;김대현;김영찬;김두훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1675-1680
    • /
    • 2000
  • Recently the uncertainty has been made rapid progress in various fields of industry but the uncertainty measurement method of acoustical test (i.e. Insertion loss, Absorption ratio, Transmission loss etc,) hasn't been established. In this study, the uncertainty of measurement method for ducted silencers is carried out according to ISO 7235. The standard uncertainty factors are composed of sound pressure level, microphone sensitivity and pistonphone calibration in this measurement. Sound pressure level is type A evaluation of uncertainty, microphone sensitivity and pistonphone calibration are type B evaluation of uncertainty. The combined standard uncertainty is calculated by two type evaluation. The expanded uncertainty is expressed by the combined standard uncertainty multiply k value which is yield the effective degree of freedom.

  • PDF

촉침식 3차원 표면거칠기 측정평가에 관한 연구 (A study on measuring and evaluating in stylus type 3-D surface roughness.)

  • 한응교;김희석
    • 한국정밀공학회지
    • /
    • 제3권1호
    • /
    • pp.60-68
    • /
    • 1986
  • Measurement of surface roughness has been done by two dimensional method until now. In recent, three dimensuional method is introduced for the precise measurement of surface roughness. But the study about stylus type three dimensional measurement method is a little. Therefore, in this study, arbitrary machined surface is selected and same part is measured by two dimensional and three dimensional method. The result is that the ratio of tow dimensional to three dimensional value is 0.9-1.1 in Ra. But two dimensional measurement method is underestimated because the ratio is 0.5-0.9 in Rz, Rmax. And it is suitable that the number of measuring line is 100 and y pitch is 5 um by three dimensional surface roughness measuring method.

  • PDF

초음파 센서를 이용한 변위 측정 시스템 개발 (A Development of Displacement Measurement System using Ultrasonic Sensor)

  • 김정섭;김상희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.142-145
    • /
    • 1995
  • This paper is to develop a measurement system of the displacement distance using ultrasonic sensors. Two 400KHz ultrasonic sensors are used for realizing the measurement system, such as one sensor transmits the sine wave and the other sensor receives this wave. The displacement is measured by the phase difference between transmitting and receiving signals. A phase defecter transforms phase difference to voltage. Because the output voltage pattern has nonlinear characteristics, the relations of the voltage and the distance are learned by a neural network. As the results of teaming, the efficiency of measurement system is improved. This system can measure the displacement distance at the accuracy of 1 micrometer level.

  • PDF