• 제목/요약/키워드: Value Measurement

검색결과 4,755건 처리시간 0.034초

The 4-channel Multiple Contact Resistance Measurement Systems using MQTT Broker Server for AC 22.9 kV COS/Lightning Arrester (MQTT 브로커 서버를 이용한 AC 22.9 kV 차단기/피뢰기의 4-채널 다중 접촉저항 측정 시스템)

  • Ra-Yun Boo;Jung-Hun Choi;Myung-Eui Lee
    • Journal of Advanced Navigation Technology
    • /
    • 제27권2호
    • /
    • pp.203-208
    • /
    • 2023
  • In this study, we propose a method to improve the precision of contact resistance measurement circuits using constant current method and voltage drop method, and implement a dashboard that monitors the measured data of contact resistance measurement systems through MQTT broker server. The contact resistance measurement system measures the resistance value and transmits the measured value to the MQTT broker server using wireless communications. This developed dashboard uses Node-RED and Node-RED-Dashboard to receive the resistance values of up to four contact resistance measurement systems and show them to user's monitor screen. Users can manage multiple measurement data using a single dashboard and easily interface with other devices through the MQTT broker server. Through the experimental results from real data measurements, the relative standard deviation about precision is improved to average 40.37% and maximum 64.73% respectively.

Manufacture of paste opaque porcelains using glycols as a solvent and evaluation of their physical properties (글리콜을 용매로 제조한 연고형 불투명 도재의 물성)

  • Kim, Sa-Hak
    • Journal of Technologic Dentistry
    • /
    • 제25권1호
    • /
    • pp.41-62
    • /
    • 2003
  • In this research, we manufactured the paste opaque porcelains using Propylene Glycol (PG) and Buthylene Glycol (BG) as a solvent, and compared the composition of solvents, the coefficient of thermal expansion, the particle size distribution, the viscosity and bonding strength to metal, and the tone with those of the commercial products(Duceram Plus, Duceram GmbH; VMK 95, Vita Co.; Noritake EX-3, Noritake Co.)used in the clinical field. The results of the research were as follows: 1. The result of solvent analysis indicated that the solvents included in the paste opaque porcelains of the control group were mainly composed of Glycols. 2. From the Coefficient of thermal expansion measurement, we drew out the following results; testing group: $14.0\times10^{-6}/^{\circ}C$, Duceram Plus: $13.9\times10^{-6}/^{\circ}C$, VMK 95: $14.3\times10^{-6}/^{\circ}C$, and Noritake EX-3: $13.3\times10^{-6}/^{\circ}C$. 3. Seen from the result of particle size distribution measurement, the experimental group was similar to the control group in 1$\mu m$ below, but the experimental group marked the highest distribution of 61% in the case of between 1$\mu m$ and 5$\mu m$. Between 5$\mu m$ and 10$\mu m$, they showed relatively similar distribution, and Noritake EX-3 was turned out the highest distribution of 29% in 10$\mu m$ above. 4. From the result of viscosity measurement, Duceram plus showed the highest viscosity throughout all the measurements followed by Noritake Ex-3, experimental group and VMK 95 in decreasing order. 5. The result of bonding strength measurement was EX 35.53 $\beta\acute{A}$, DU 40.88 $\beta\acute{A}$, VM 39.43 $\beta\acute{A}$, and NO 35.39 $\beta\acute{A}$, and no significant difference was found between the experimental group and the control groups(P>0.05). 6. The measurement of the tone indicated that the $L^*$ value of the experimental group was 86.89 0.63 in average, which is higher than the control group in its brightness. In the case of the $a^*$ value, Duceram Plus, VMK 95 and EX-3 showed positive value, whereas the testing group was turned out negative value. In $b^*$ value, Duceram Plus proved the highest. From the results of this research, the paste opaque porcelains using Propylene Glycol (PG) and Buthylene Glycol (BG) as a solvent did not make differences from the commercial products that are actually used in the clinical fields. Therefore, it is possible to utilize Propylene Glycol (PG) and Buthylene Glycol (BG) for the paste opaque porcelains of P.F.M crown. It is also recommended that further researches concerning the compositions and forms of powder, the types of organic solvent components and the ratio of mixture proceeded in order to improve the level of productivity in the future.

  • PDF

THE EFFECT OF AUTOCLAVE STERILIZATION AND REUSE OF $SMARTPEG^{TM}$ ON THE IMPLANT STABILITY QUOTIENT (ISQ) MEASUREMENT ($Smartpeg^{TM}$의 고압멸균소독 및 재사용이 임플랜트 안정성 지수(ISQ) 측정에 미치는 영향)

  • Kang, In-Ho;Kim, Myung-Joo;Lim, Young-Jun;Kim, Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제45권5호
    • /
    • pp.644-652
    • /
    • 2007
  • Statement of problem: Resonance frequency analysis is evaluated as the non-invasive and objective method for the evaluation of implant stability and has been increasingly used. It is necessary to evaluate the factors affect the ISQ measurement stability. Purpose: This study was performed to evaluate the effect of the autoclave sterilization and reuse of $Smartpeg^{TM}$ on ISQ measurement. Material and methods: $SmartPeg^{TM}$ (Integration Diagnostics Ltd., $G\ddot{o}teborg$, Sweden) of autoclave group (A) was autoclave sterilized 9 times and $Smartpeg^{TM}$ of reuse group (R) was reused 9 times. Ten $SmartPeg^{TM}s$ were allocated to each group and after each autoclave sterilization and reuse, implant stability quotient (ISQ) values were measured 3 times from the two directions a and b at a right angle. $Osstell^{TM}$ mentor (Integration Diagnostics Ltd. $G\ddot{o}teborg$, Sweden) was used and type 1 (article no. 100353) $Smartpeg^{TM}$ was selected according to $Smartpeg^{TM}$ reference list. Osstem Implant US II future (Osstem Co., Seoul, Korea) in $4.0mm{\times}11.5mm$ was embedded in the self-curing acrylic resin ($Orthojet^{(R)}$, Lang Dental, U.S.A.). Data was statistically analyzed by one-way ANOVA $({\alpha}=.05)$ and scheffe test was done where a significant difference exist. Correlation test was also done between ISQ value and the number of autoclave sterilization or reuse. Results: 1. In autoclave group, the means and sd. of ISQ value before autoclave sterilization were $84.97{\pm}0.41,\;84.93{\pm}0.74$ at direction a and b. There was significant differences between autoclave groups at direction a and b (P=.000). 2. In reuse group, the means and sd. of ISQ value before reuse were $85.40{\pm}0.62,\;85.50{\pm}0.57$ at direction a and b. There was no significant difference between reuse groups at direction a and b (P>.05). 3. There was a weak positive correlation between the number of reuse and ISQ value at direction a and b (${\gamma}=.207$ and .246, P<.01). Conclusion: Within the limitations of this study, the following conclusions were drawn. Till ninth reuse of $Smartpeg^{TM}$, the ISQ measurement stability did not be affected. After twice autoclave sterilization of $Smartpeg^{TM}$ the ISQ measurement stability was affected.

A Study on Relationship between Service Quality and Payment Value in Mobile Communication Industry

  • Kim, Min-Cheol;Noh, Kyoo-Sung
    • 한국디지털정책학회:학술대회논문집
    • /
    • 한국디지털정책학회 2004년도 International Conference on Digital Policy & Management
    • /
    • pp.203-210
    • /
    • 2004
  • In this paper, the conceptualization and the measurement of service quality and the relationships among service quality, consumer satisfaction, value, and post behavior (post behavior and recommendations to others) are investigated. The results suggest that service quality is an antecedent of consumer satisfaction and that consumer satisfaction exerts a strong influence on payment value and post behavior.

  • PDF

An international Comparison Measurement of Silicon Wafer Sheet Resistance using the Four-point Probe Method

  • Kang, Jeon-Hong;Ying, Gao;Cheng, Yuh-Chuan;Kim, Chang-Soo;Lee, Sang-Hwa;Yu, Kwang-Min
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.325-330
    • /
    • 2015
  • With approval from the Asia Pacific Metrology Program Working Group on Materials Metrology (APMP WGMM), an international comparison for sheet resistance standards for silicon wafers was firstly conducted among Korea Research Institute of Standards and Science (KRISS) in Korea, CMS/ITRI in Taiwan, and NIM in China, which are national metrology institutes (NMIs), from August 2011 to January 2012. The sheet resistance values of the standards are $10{\Omega}$, $100{\Omega}$, and $1000{\Omega}$; the measurement was conducted in sequence at KRISS, CMS/ITRI, NIM, and KRISS again using the four-point probe method with single and dual configuration techniques. The reference value for the measurement results of the three NMIs was obtained through averaging the values of the three results for each sheet resistance range. The differences between the reference value and the measured values is within 0.22% for $10{\Omega}$, 0.17% for $100{\Omega}$, and 0.12% for $1000{\Omega}$. Therefore, the international consistency for conducting sheet resistance measurements is confirmed within 0.22% through the APMP WGMM approved comparison.

A Study on the Object Angle Inference in a Sonar Sensor Array System (초음파센서 배열 시스템에서 물체의 각도 추론에 관한 연구)

  • 나승유;박민상
    • Proceedings of the IEEK Conference
    • /
    • 대한전자공학회 1998년도 하계종합학술대회논문집
    • /
    • pp.271-274
    • /
    • 1998
  • Ultrasonic sensors are becoming indispensable components in every sector of automation equipments due to many advantages. But the main purposes of the noncontact sensing device are rather narrowly confined within object detection and distance measurement. To widen the realm of the applications to object recognition, ultrasonic sensors need to improve the recognition resolution to a certain amount. To resolve the problem of spatial resolution restriction, an increased number of the sensors in the forms of a linear array or 2-dimensional array of the sensor has been used. Also better resolution has been obtained by shifting the array in several steps using mechanical actuators. For an object recognition using ultrasonic sensors, measurements of distance, shift, oblique angle in certain ranges should be obtained. But a little attention has been paid to the measurement of angles. In this paper we propose a practical method for an object angular value detection in addition to distance measurement in ultrasonic sensor array system with little additional hardware burden. Using the established measurement look-up table for the variations of distance, shift, angle and transmitter voltages for each sensor characteristics, a set of different return echo signals for adjacent receivers are processed to provide enhanced angular value reading for an object.

  • PDF

A Design of Real-time Automatic Focusing System for Digital Still Camera Using the Passive Sensor Error Minimization (수동 센서의 오차 최소화를 이용한 실시간 DSC 자동초점 시스템 설계)

  • Kim, Geun-Seop;Kim, Deok-Yeong;Kim, Seong-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • 제51권5호
    • /
    • pp.203-211
    • /
    • 2002
  • In this paper, the implementation of a new AF(Automatic Focusing) system for a digital still camera is introduced. The proposed system operates in real-time while adjusting focus after the measurement of distance to an object using a passive sensor, which is different from a typical method. In audition, measurement errors were minimized by using the data acquired empirically, and the optimal measuring time was obtained using EV(Exposure Value) which is calculated from CCD luminance signal. Moreover, this system adopted an auxiliary light source for focusing in absolute dark conditions, which is very hard for CCD image Processing. Since this is an open-loop system adjusting focus immediately after the distance measurement, it guarantees real-time operation. The performance of this new AF system was verified by comparing the focusing value curve obtained from AF experiment with the one from the measurement by MF(Manual-Focusing). In both case, edge detector was used for various objects and backgrounds.

A Study on Accuracy Detection Method for Signal Peak Voltage (신호용 PEAK 전압 정밀검출에 관한 연구)

  • Park, Ho-Chul;Sung, Hyung-Su;Han, Seung-Moon;Han, Jeong-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.2528-2530
    • /
    • 2000
  • In general, Diode makes a major role in electronic circuit. For example, switching of rectifier, cross current of switching rectifier, energy transfer of electronic element and reverse charge of capacitor, voltage insulation, energy feedback from load to power supply, and such as recovery of storaged energy. Generally, We regard power diode as ideal element, but it has a certain boundary actually, specially, We use diode for detecting circuit peak hold voltage signal. It has cut in voltage. It occurs error of measurement value namely. This error, below in region diode voltage drop (0.7v) measurement value is wholesome signal, Specially, We can not get precision data. Therefore, precision level is low between theoretical and measurement data because of error in actual circuit. Conclusionally, In this paper, We define the error concerning to the power diode characteristics which is used detecting of the minute signal, and recommend the method that minimize measurement error.

  • PDF

Breathing Measurement and Sleep Apnea Detection Experiment and Analysis using Piezoelectric Sensor

  • Cho, Seokhyang;Cho, Seung-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • 제22권11호
    • /
    • pp.17-23
    • /
    • 2017
  • In this paper, we implemented a respiration measurement system consisting of piezoelectric sensor, respiration signal processing device, and a viewer on a notebook. We tried an experiment for measuring respiration and detecting sleep apnea syndrome when a subject lay on a bed. We applied the respiration measurement algorithm to sensor data obtained from four subjects. In order to get a good graph shape, data manipulation methods such as moving averages and maximum values were applied. The window size for moving average was chosen as N=70, and the threshold value for each subject was customized. In this case, the proposed system showed 96.0% accuracy. When the maximum value among 90 data was applied instead of moving average, our system achieved 95.1% accuracy. In an experiment for detecting sleep apnea syndrome, the system showed that sleep apnea occurred correctly and calculated the average interval of sleep apnea. While infants or the elderly as well as patients with sleep apnea syndrome are lying down on a bed, our results are also expected to be able to cope with some accidental emergency situation by observing their respiration and detecting sleep apnea.

An Alternating Motion Technique Using Linear Variable Differential Transformers (선형변이 차동변압기를 이용한 왕복운동 계측기법)

  • 최주호;김윤겸
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.1073-1077
    • /
    • 1996
  • This paper presents a recoil and counter recoil(R&CR) motion measurement method using linear variable differential transformers(LVDT). The output of a LVDT is obtained from the differential voltage of the 2nd transformers. As a sensor core is attached at the motion body, the output is directly proportional to the core motion. Displacement, velocity and acceleration are measure from the core length. With a comparison between the measurement result and the known value which is obtained by the precision steel tape, the accuracy and the usefulness of the proposed scheme is validated.

  • PDF