• Title/Summary/Keyword: Value Frame Analysis

Search Result 301, Processing Time 0.024 seconds

REAL OPTIONS VALUATION MODEL OF LINE EXPANSION PROBLEM IN THE AMOLED INDUSTRY LINE EXPANSION (리얼옵션을 활용한 AMOLED산업 라인 증설의 옵션가치)

  • Lee, Su-Jeong;Kim, Do-Hun
    • 한국경영정보학회:학술대회논문집
    • /
    • 2008.06a
    • /
    • pp.957-962
    • /
    • 2008
  • We propose a model for the line expansion problem in the AMOLED (Active Matrix Organic Light Emitting Diodes) industry, which now faces market uncertainty: for example, changing customer needs, technological development path, etc. We focus on the optimal investment time and size of the AMOLED production lines. In particular, employed here is the ROV (Real Options Valuation) model to show how to capture the value of line expansion and to determine the optimal investment time. The ROV framework provides a systematic procedure to quantify an expected outcome of a flexible decision which is not possible in the frame of the traditional NPV (Net Present Value) approach. Furthermore, we also use Monte Carlo simulation to measure the uncertainty associated with the line expansion decision; Monte Carlo simulation estimates the volatility of a decision alternative. Lastly, we present a scenario planning to be conducted for what-if analysis of the ROV model.

  • PDF

A Study on Loss Analysis of Open-Frame Type DC-DC Converter (개방형 DC-DC 컨버터의 손실 분석에 관한 연구)

  • Yon, Je-Sun;Lee, Bong-Jun;Ahn, Tae-Young
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1193-1195
    • /
    • 2003
  • In this paper, to analyze efficiency characteristic, one of important factors in design of DC-DC converter prototype, theoretically derived power loss of individual components generating in DC-DC converter and compared theoretical results with experimental results. For evaluation of results, active clamp type Forward DC-DC converter with synchronous rectifier was composed of experimental converter. Efficiency result measured in experimental converter was compared with theoretical efficiency result derived in this paper. In comparative result, a fact that derived theoretical value and experimental value comparatively correspond have been able to verify.

  • PDF

Comparison of Effectiveness about Image Quality and Scan Time According to Reconstruction Method in Bone SPECT (영상 재구성 방법에 따른 Bone SPECT 영상의 질과 검사시간에 대한 실효성 비교)

  • Kim, Woo-Hyun;Jung, Woo-Young;Lee, Ju-Young;Ryu, Jae-Kwang
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.9-14
    • /
    • 2009
  • Purpose: Nowadays in the nuclear medicine, many studies and efforts are being made to reduce the scan time, as well as the waiting time to be needed to execute exams after injection of radionuclide medicines. Several methods are being used in clinic, such as developing new radionuclide compounds that enable to be absorbed into target organs more quickly and reducing acquisition scan time by increase the number of Gamma Camera detectors to examine. Each medical equipment manufacturer has improved the imaging process techniques to reduce scan time. In this paper, we tried to analyze the difference of image quality between FBP, 3D OSEM reconstruction methods that commercialized and being clinically applied, and Astonish reconstruction method (A kind of Iterative fast reconstruction method of Philips), also difference of image quality on scan time. Material and Methods: We investigated in 32 patients that examined the Bone SPECT from June to July 2008 at department of nuclear medicine, ASAN Medical Center in Seoul. 40sec/frame and 20sec/frame images were acquired that using Philips‘ PRECEDENCE 16 Gamma Camera and then reconstructed those images by using the Astonish (Philips’ Reconstruction Method), 3D OSEM and FBP methods. The blinded test was performed to the clinical interpreting physicians with all images analyzed by each reconstruction method for qualitative analysis. And we analyzed target to non target ratio by draws lesions as the center of disease for quantitative analysis. At this time, each image was analyzed with same location and size of ROI. Results: In a qualitative analysis, there was no significant difference by acquisition time changes in image quality. In a quantitative analysis, the images reconstructed Astonish method showed good quality due to better sharpness and distinguish sharply between lesions and peripheral lesions. After measuring each mean value and standard deviation value of target to non target ratio with 40 sec/frame and 20sec/frame images, those values are Astonish (40 sec-$13.91{\pm}5.62$ : 20 sec-$13.88{\pm}5.92$), 3D OSEM (40 sec-$10.60{\pm}3.55$ : 20 sec-$10.55{\pm}3.64$), FBP (40 sec-$8.30{\pm}4.44$ : 20 sec-$8.19{\pm}4.20$). We analyzed target to non target ratio from 20 sec and 40 sec images. And we analyzed the result, In Astonish (t=0.16, p=0.872), 3D OSEM (t=0.51, p=0.610), FBP (t=0.73, p=0.469) methods, there was no significant difference statistically by acquisition time change in image quality. But FBP indicates no statistical differences while some images indicate difference between 40 sec/frame and 20 sec/frame images by various factors. Conclusions: In the circumstance, try to find a solution to reduce nuclear medicine scan time, the development of nuclear medicine equipment hardware has decreased while software has marched forward at a relentless. Due to development of computer hardware, the image reconstruction time was reduced and the expanded capacity to restore enables iterative methods that couldn't be performed before due to technical limits. As imaging process technique developed, it reduced scan time and we could observe that image quality keep similar level. While keeping exam quality and reducing scan time can induce the reduction of patient's pain and sensory waiting time, also accessibility of nuclear medicine exam will be improved and it provide better service to patients and clinical physician who order exams. Consequently, those things make the image of department of nuclear medicine be improved. Concurrent Imaging - A new function that setting up each image acquisition parameter and enables to acquire images simultaneously with various parameters to once examine.

  • PDF

A SES Alarmed Link Encryption Synchronization Method Having Optimized Threshold Value for High-Speed Video Data Encryption

  • Kim, Hyeong-Rag;Lee, Hoon-Jae;Kim, Ki-Hwan;Jung, Ju-Hyun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.9
    • /
    • pp.57-64
    • /
    • 2017
  • CCSDS Standard is widely used in the international space telecommunication area. But standard recommendation of CCSDS is not restrictive, so, we can select an appropriate encryption protocol among the layer. For synchronization, encryption sync is attached in the beginning of the encrypted data. In the exceptional environmental condition, although the receiver can not decrypt the normal data, the sender have no conception of that situation. In this paper, we propose a two-stage SES alarmed link encryption synchronization method having optimized threshold value necessary to decide whether the receiver has a correct decryption or not. first, through the experiment of mutual relations between error rate and encryption synchronization detection error, we can predict worst communication environment for the selected encryption synchronization pattern. second, through the experiment for finding what number of consecutive frame synchronization error is an appropriate reference value and analysis of that experiment, we suggest an optimized threshold value for resynchronization request. lastly, through the output images we can predict the probability error that should be guaranteed by channel coder.

Variable Dynamic Threshold Method for Video Cut Detection (동영상 컷 검출을 위한 가변형 동적 임계값 기법)

  • 염성주;김우생
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.4A
    • /
    • pp.356-363
    • /
    • 2002
  • Video scene segmentation is fundamental role for content based video analysis and many kinds of scene segmentation schemes have been proposed in previous researches. However, there is a problem, which is to find optimal threshold value according to various kinds of movies and its content because only fixed single threshold value usually used for cut detection. In this paper, we proposed the variable dynamic threshold method, which change the threshold value by a probability distribution of cut detection interval and information of frame feature differences and cut detection interval in previous cut detection is used to determine the next cut detection. For this, we present a cut detection algorithm and a parameter generation method to change the threshold value in runtime. We also show the proposed method, which can minimize fault alarm rate than the existing methods efficiently by experimental results.

Response modification factor of suspended zipper braced frames

  • Abdollahzadeh, Gholamreza;Abbasi, Mehdi
    • Steel and Composite Structures
    • /
    • v.18 no.1
    • /
    • pp.165-185
    • /
    • 2015
  • The suspended zipper bracing system is suggested to reduce the flaws of ordinary zipper braced and concentric inverted V braced frames. In the design procedure of suspended zipper bracing systems, columns and top story truss elements are strengthened. This bracing system show different performances and characteristics compared with inverted V braced and ordinary zipper frames. As a result, a different response modification factor for suspend zipper frames is needed. In this research paper, the response modification factor of suspended zipper frames was obtained using the incremental dynamic analysis. Suspended zipper braced frames with different stories and bay lengths were selected to be representations of the design space. To analyze the frames, a number of models were constructed and calibrated using experimental data. These archetype models were subjected to 44 earthquake records of the FEMA-P695 project data set. The incremental dynamic analysis and elastic dynamic analysis were carried out to determine the yield base shear value and elastic base shear value of archetype models using the OpenSEES software. The seismic response modification factor for each frame was calculated separately and the values of 9.5 and 13.6 were recommended for ultimate limit state and allowable stress design methods, respectively.

A Study on the Optimal Image Acquisition Time of 18F- Flutemetamol using List Mode (LIST mode를 이용한 18F-Flutemetamol 의 최적 영상획득 시간에 관한 연구)

  • Ryu, Chan-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.891-897
    • /
    • 2021
  • With the development of Amyloid PET Tracer, the accuracy of Alzheimer's diagnosis can be improved through the identification of beta-amyloid neurites. However, the long image acquisition time of 20 minutes can be difficult for the patient. PET/CT scans are sensitive to patient movement and may partially affect test results. In this study, we studied the proper image acquisition time without affecting the quantitative evaluation of the image through the list mode acquisition method according to the time of the distribution of radioactive drugs in the body. The list mode includes information about time compared to the existing frame mode, and it is easy to analyze data because it can reconstruct images about the time that researchers want. The research method obtained a reconstructed image by time using a list mode of 5min frame/bed, 10min frame/bed, 15min frame/bed, and 20min frame/bed to compare the difference between signal-to-pons take ratio (SNR) and lesion-to-pons uptake ratio (LPR) and the difference in reading time to obtain an appropriate image. As a result of quantitative analysis, when measuring in list mode, SUVmean values decreased in 6 regions of interest as the image acquisition time increased, but showed the largest difference in 5 min/bed images, followed by 10 min/bed and 15 min/bed. As a result, the difference in SUVmean values decreased. Therefore, it was found that SUVmean values at 15 min/bed did not differ enough to not affect image evaluation. There was no difference in LPR values. As a result of the qualitative analysis, there was no change in the reading findings according to the PET image acquisition time and there was no significant difference in the qualitative analysis score of the image reconstruction according to time. As a result of the study, there is no significant difference between 15 min/bed and 20 min/bed images during the 18F-flutemetamol PET/CT test, so it can be said that it is clinically useful to reduce the image acquisition time selectively using 15 min/bed via list mode depending on the patient's condition.

A Study on the News Frame of COVID-19 Vaccine through Structural Topic Modeling and Semantic Network Analysis

  • Eun-Ji Yun;Bo-Young Kang
    • Journal of the Korea Society of Computer and Information
    • /
    • v.28 no.5
    • /
    • pp.129-153
    • /
    • 2023
  • This study was conducted in the context of the Covid-19 pandemic by analyzing a large amount of press report frames regarding the Covid-19 vaccine which is of great public interest, in order to explore the role and direction of trusted media as core elements of crisis communication. The study period lasted for eight months beginning in November 2020 when the development of the Covid-19 vaccine was in progress until June 2021. Set-up as research subjects were the Chosun Ilbo, Joongang Ilbo, Dong-A Ilbo and Hankyoreh according to their public confidence rankings and number of readers.The analysis method used structured topic Modeling (STM) and semantic network analysis. As a result, based on a clear cluster of word structures and a central analysis value, a total of 64 relevant frames, 16 for each news company, were gathered. In the third phase a comparative analysis of the four news companies was carried out to verify the organizational degree of the frames and substantial differences.

A Case Study of Placed Remicon in "S" Apartment (현장 콘크리트의 품질에 관한 소고)

  • 이학영;윤두순
    • Journal of the Korean Professional Engineers Association
    • /
    • v.30 no.6
    • /
    • pp.113-120
    • /
    • 1997
  • This subject,'S" apartment structural frame has not been achieved without considerable effort by all quality controller involved. Therefore, it is appropriate at this time to report by all the fact of concrete quality control in our site. These are emphasized that the average strength of placed concrete must always exceed the specified value of design strength used in the structural design phase. In general, quality of ready mixed concrete largely depends not only upon the manner of production and proper observance of recognized methods of placement, finishing, curing, transportation etc. ,but also many kinds of influential factors even more handling of the test procedure, As this practical report, approaching to judgement by analysis of sampled specimens in site weather placed concrete have satisfied quality compare the specified strength with the target strength which is applied to standard deviation related with influential factors as above mentioned. This case study is consist of 1) A foreword, 2) Site brief, 3) A precondition for analysis, 4) A formulas derivation and quality analysis, 5) Economic gains by the coefRcient of increase and 6) A conclusion.sion.

  • PDF

Development of Decision Support System for the Design of Steel Frame Structure (강 프레임 구조물 설계를 위한 의사 결정 지원 시스템의 개발)

  • Choi, Byoung Han
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.1
    • /
    • pp.29-41
    • /
    • 2007
  • Structural design, like other complex decision problems, involves many trade-offs among competing criteria. Although mathematical programming models are becoming increasingly realistic, they often have design limitations, that is, there are often relevant issues that cannot be easily captured. From the understanding of these limitations, a decision-support system is developed that can generate some useful alternatives as well as a single optimum value in the optimization of steel frame structures. The alternatives produced using this system are "good" with respect to modeled objectives, and yet are "different," and are often better, with respect to interesting objectives not present in the model. In this study, we created a decision-support system for designing the most cost-effective moment-resisting steel frame structures for resisting lateral loads without compromising overall stability. The proposed approach considers the cost of steel products and the cost of connections within the design process. This system makes use of an optimization formulation, which was modified to generate alternatives of optimum value, which is the result of the trade-off between the number of moment connections and total cost. This trade-off was achieved by reducing the number of moment connections and rearranging them, using the combination of analysis based on the LRFD code and optimization scheme based on genetic algorithms. To evaluate the usefulness of this system, the alternatives were examined with respect to various design aspects.