• Title/Summary/Keyword: Vacuum cleaner noise

Search Result 60, Processing Time 0.024 seconds

Characteristics of Flow-Induced Noise in the Suction Nozzle of a Vacuum Cleaner with a Double-Blade Fan (이중 블레이드 팬이 장착된 진공청소기 브러쉬의 유동소음 특성)

  • Park, I-Sun;Sohn, Chae-Hoon;Oh, Jang-Keun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.2
    • /
    • pp.205-213
    • /
    • 2011
  • The characteristics of noise generation in the suction nozzle of a vacuum cleaner are analyzed numerically and experimentally. First, the flow resistance induced by each element in the suction nozzle of a vacuum cleaner with a double-blade rotary fan is investigated numerically and its relation with flow-induced noise and suction performance is examined in an anechoic room. The flow resistance and vorticity in the suction nozzle are calculated, and it is found that they are closely related to flow-induced noise and that the upper limit of noise reduction is only 4 dBA. This upper limit can be achieved by changing the design of the brush nozzle. Two methods for noise reduction by enlargement of flow-inlet area and by optimization of the number of blades are tested. Finally, the effects of each method are verified experimentally.

The Analysis of the Unsteady Flow Field and Aerodynamic Sound of Fan Motor in a Vacuum Cleaner (진공청소기용 팬 모터의 비정상 유동 해석 및 공력소음 해석)

  • 김재열;심재기;송경석;오성민;양동조;김우진
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.04a
    • /
    • pp.281-286
    • /
    • 2004
  • The vacuum cleaner motor runs on very high speed for the suction power. Specially, the motive power is provided by the impeller being rotate on very high speed. And centrifugal fan consists of the impeller, the diffuser, and the circular casing. Due to the high rotating speed or the impeller and small gap distance between the impeller and diffuser, the centrifugal fan makes very high noise level at BPF and harmonic frequencies. In order to calculate the sound pressure of centrifugal fan, the unsteady flow data is needed. And Noise cause is dividing to fluid noise by exhaust flow of fan and vibration noise by rotational vibration of vacuum cleaner fan motor. Until now, measuring method has been used to measure vibration by the accelerometer; this method has been not measured for the vibration in some parts of brush and commutator because of motor construction and 3-D vibrating mode. This paper was purposed on the accurate analysis, using laser vibration analyzer,. By using this measured data of noise cause against the difficult part in old times, we would like to use for the design of silent fan motor.

  • PDF

THE PERFORMANCE IMPROVEMENT OF VACUUM CLEANER BY ANALYSIS OF THE FLOW AROUND CENTRIFUGAL FAN (진공청소기용 원심팬 주위의 유동해석을 통한 성능개선)

  • Park, J.W.;Ki, M.C.;Park, H.K.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2007.10a
    • /
    • pp.82-87
    • /
    • 2007
  • A cleaner has trouble with too much noise and power consumption. To solve these problems, the investigation for motors, which are the main component of vacuum cleaner, is required. However, it is difficult to analyze the flow by the experimental means because of the high speed of the fan rotation ranging from 30,000 rpm to 50,000 rpm. Moreover it takes much time to perform the numerical simulation for the flow. In this research, it is aimed to analyse the flow through the centrifugal fan which is believed to be a main noise source, by the computational method. The efficiency of the centrifugal fan is affected by friction loss, shock loss and so on. Those losses depend on factors like the velocity of impeller, blade shape and etc. Accordingly, the influence of the shape of impeller on the flow is investigated in this study. The computational analysis was done by changing impeller shapes. The flow around the centrifugal fan is simulated by applying the moving mesh. To verify the validity of the computation results, the air flow rate and the pressure field to the cleaner is compared with the experimental data. All simulations are performed by using commercial code SC/Tetra. The calculated results show good agreement with the experimental ones qualitatively and it is believed to be promising to use computational simulation in the improvement of the vacuum cleaner performance.

  • PDF

Analysis of Objective Sound Quality Features for Vacuum Cleaner Noise (청소기 소음 측정을 위한 객관적 음질 특성 분석)

  • Lee, Sang-Wook;Cho, Youn;Park, Jong-Geun;Hwang, Dae-Sun;Song, Chi-Mun;Lee, Chul-Hee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.4
    • /
    • pp.258-264
    • /
    • 2010
  • In this paper, we propose an objective quality feature which is based on the human auditory system to measure vacuum cleaner noise. It is observed that some frequency bands are more sensitive to the human auditory system. Therefore, we divided the audible frequency range of vacuum cleaner noise into a number of frequency bands and the average energy of these bands was calculated. Among a number of average energies, an average energy of a frequency band was selected as the proposed feature. In order to test the performance of the proposed feature, fourteen vacuum cleaners were chosen and the noise was recorded in an anechoic-chamber. Then we performed subjective tests to obtain subjective scores of the noise data using the PCM (paired comparison method) and ACR (absolute category rating) subjective methods. The proposed objective quality feature shows high correlation with the subjective scores.

Effect of Suction Nozzle Modification on the Performance and Aero-acoustic Noise of a Vacuum Cleaner

  • Park, Cheol-Woo;Lee, Sang-Ik;Lee, Sang-Joon
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.9
    • /
    • pp.1648-1660
    • /
    • 2004
  • The suction nozzle of a vacuum cleaner was modified to enhance the power performance and to reduce the airflow-induced acoustic noise. The suction power efficiencies of the vacuum cleaner were measured for various nozzles; (1) original nozzle, (2) original nozzle with modified trench height, (3) original nozzle with modified connecting chamber, and (4) a combination of (2) and (3). In addition, the suction pressure and sound pressure level around the suction nozzle were measured to validate the reduction of acoustic noise. The power efficiency and mean suction pressure increased when the trench height of the suction nozzle was increased. This was attributed to the suppression of the flow separation in the suction channel. Modification of the connecting chamber in the original nozzle, which had an abrupt contraction from a rectangular chamber into a circular pipe, into a smooth converging contraction substantially improved the suction flow into the connecting pipe. When both modifications were applied simultaneously, the resulting suction nozzle was more effective from the viewpoints of aerodynamic power increase and sound pressure level reduction.

On the Situation of House Cleaning and the Housemakers Opinion for Utility of the Vacuum Cleaner in Korea (한국에 있어서의 가정청소의 실태와 전기청소기에 관한 평가 - 한국과 일본의 비교 -)

  • 신경주
    • Journal of the Korean Home Economics Association
    • /
    • v.20 no.3
    • /
    • pp.55-63
    • /
    • 1982
  • We are studying on the home economics, particularly tools and machines used in household affairs. The object of this paper is to rationalize house cleaning method and to improve the used cleaning tools. We have made a social survey in Korea about the real situation of house cleaning as the first phase of this research. The contents are as follows: 1) The consciousness of housemakers for house cleaning. 2) The methods of house cleaning. 3) The used type of vacuum cleaner. 4) Merits and demerits of vacuum cleaner. 5) Troubles of vacuum cleaner etc. The results has been made in comparison with the same social survey in japan and a small scale different survey in The United States of America by auther in 1979. The results are as follow (in Korea). 1. The almost of housemakers are affirmative in charge of household affairs(95%). 2. In household affairs, only 9% of housemakers dislike cleaning work, but 40% of housemakers do not a cleaning work as a daily periodically. 3. In general household, they do a cleaning work with broom, duster and dust cloth, and then the cleaning work is faily backward in mechanization(The possession of vacuum is 19%). 4. The main dissatisfaction of vacuum cleaner is a noise, and also the difficulty of the cleaning in a corner of the room is shown in high percentage too.

  • PDF

Active silencer using switching method in vaccum cleaner (청소기 소음원에 적용한 스위칭 방식 능동 소음기)

  • 성덕만;이승요;한석우;최규하
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.193-199
    • /
    • 1997
  • Until now, environmental problem has become more and more serious, and acoustic noise is one of environmental pollutions. For many years, ANC(Active Noise Control) has been made to reduce this noise. In this paper, active silencer using switching method is studied. This silencer is composed of single-phase full bridge inverter to drive cancelling loudspeaker. The inverter is controlled to reduce noise by ramp comparison control method. At the vacuum cleaner, noise control with FFCS(Feed-Forward Control Structure) is applied and geometric arrangement is replaced to avoid unstability of FFCS.

  • PDF

Study on Establishment of the Noise Grade Criteria for Household Appliances (가전제품 소음등급 기준설정에 관한 연구)

  • Park, Hyungkyu;Lee, Jaewon;Lee, Wooseok;Han, Jinseok;Gu, Jinhoi
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.12
    • /
    • pp.1237-1242
    • /
    • 2012
  • No matter how low it might be, noise from home appliances in indoor environment cause displeasure for residents as it is produced nearby. Electronic goods including vacuum cleaner and washing machine generate high frequency noise, which interrupts TV-watching or conversations and cause noises between floors in apartment houses. In particular, refrigerators make constant noise late at night, hampering the study for exams and causing sleeplessness. Korea, despite the government's efforts to promote low-noise goods based on the noise test by corporation, there is a lack of standardization in the test method, test condition and measuring equipments. This is a major reason that lowers the reliability of low-noise products. At present, low-noise home appliances are certified with eco labeling in the nation but, only 7 brands of refrigerators, 4 brands of washing machines and 97 brands of air-conditioners obtained certification as of august, 2011. In addition, none of Kimchi-refrigerator and vacuum cleaner brands were approved as low-noise home appliances. This shows Korea's relatively underdeveloped market for low-noise products, which, in part, is because of the difficulties companies face in being certified with eco labeling as they should satisfy various requirements such as power-saving and eco-friendly design besides low-noise features. As a result, low-noise labeling for home appliances should be established for the revised noise and vibration management law and the study was carried out to establish low-noise labeling system for major noise sources including vacuum cleaner, washing machine, air-conditioner and refrigerator.

Reduction of Flow-Induced Noise in Suction Nozzle of a Vacuum Cleaner by Adopting a Cross-Flow Fan (횡류팬을 적용한 진공청소기 흡입노즐내 유동 소음 저감에 관한 연구)

  • Park, I-Sun;Sohn, Chae-Hoon;Lee, Sung-Cheol;Oh, Jang-Keun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.935-938
    • /
    • 2007
  • In suction nozzle of a vacuum cleaner, where flow-induced noise is generated mainly by flow resistance, several ideas to reduce noise are investigated. To increase fan performance, blade number is optimized and a centrifugal fan is replaced by a cross-flow fan, In addition, gear ratio of fan to drum brush is changed. It is found that fan performance is increased by adopting these methods. Next, the blade height of the fan is decreased to reduce sound pressure level, which causes inevitably decrease in fan performance. Eventually, flow-induced noise is reduced by 6.3 dBA in its overall level with the fan performance maintained.

  • PDF