• Title/Summary/Keyword: Vacuum Extraction

Search Result 160, Processing Time 0.046 seconds

Ultrasound-guided Needle Aspiration of Cranial Epidural Hematoma in a Neonate

  • Lee, Dong-Hoon;Lee, Sang-Weon;Lee, Tae-Hong;Ban, Ji-Eun
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.1
    • /
    • pp.61-63
    • /
    • 2006
  • We report a unique case of a neonate with an epidural hematoma induced by vacuum extraction. The epidural hematoma, communicating with a cephalhematoma through a linear skull fracture, disappeared after ultrasound-guided needle aspiration. The patient quickly recovered and one month later computed tomography revealed a complete resolution of the epidural hematoma.

Volatile Compounds in Oyster Hydrolysate Produced by Commercial Protease

  • Cha, Yong-Jun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.24 no.3
    • /
    • pp.420-426
    • /
    • 1995
  • Volatile compounds in raw oyster and oyster hydrolysate produced with protease were compared by vacuum simultaneous steam distillation-solvent extraction/gas chromatography/mass spectrometry. Sixty-two volatile compounds were detected in both samples. Of these, 57 were positively identified, composed mainly of aldehydes(12), ketones(9), alcohols(14), nitrogen-containing compounds(9), acids(6), terpenes(4), and miscellneous compounds(8). Levels of acids decreased after hydrolysis, whereas several other compounds such as aldehydes, ketones, and nitrogen containing compounds increased. Pyrazines, found in high abundance, were only detected in oyster hydrolysate.

  • PDF

Fabrication of InSb TFT and Parameters EXtraction Using Optimization Technique (InSb TFT의 제작과 최적화 기법에 의한 파라메타 추출)

  • Kim, Hong Bae;Son, Sang Hee;Kwack, Kae Dal
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.24 no.1
    • /
    • pp.67-72
    • /
    • 1987
  • InSb TFT is fabricated by the vacuum evaporation method and I-V characteristics are measured. Employing Davidon Fletcher-Powell algorithm, the device parameters are extracted. The current-voltage relations calculated by extracdted parameters are in good agreement with experimental results. It is found that optimization technique may be more simple and accurate than curve fitting method in device parameters extration.

  • PDF

Improvement of Light Extraction Efficiency of GaN-Based Vertical LED with Microlens Structure

  • Kwon, Eunhee;Kang, Eun Kyu;Min, Jung Wook;Lee, Yong Tak
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.221-221
    • /
    • 2013
  • Vertical LED (VLED) has been recognized as a way to obtain the high-power LED due to their advantages [1]. However, approximately 4% of the light generated from the active region is extracted, if the light extraction from side walls and back side is neglected because of Fresnel reflection (FR) and total internal reflection (TIR) [2,3]. In this study, the optical simulation of the VLED with the various microstructures was performed. Among them, the microlens having the diameter of 3 ${\mu}m$ and the height of 1.5 ${\mu}m$ shown the best result was chosen, and then, optimized microlens was formed on a GaN template using conventional semiconductor process. Various microstructures were proposed to improve the light extraction efficiency (LEE) of the VLED for the simulation. The LEE was simulated using LightTools based on a Monte Carlo ray tracing. The microstructures with hemisphere, cone, truncated and cylinder pattern having diameter of 3 ${\mu}m$ were employed on the top layer of the VLED respectively. The improvement of the LEE by using the microstructure is 87% for the hemisphere, 77% for the cone, 53% for the truncated, 21% for the cylinder, compared with the LEE of the flat surface at the reflectance of 85%. The LEE was increased by 88% at the height of 1.5 ${\mu}m$, compared with the LEE of the flat surface. We found that the microlens on the top layer is the most suitable for increasing the LEE. In order to apply the proposed microlens on n-GaN surface, we fabricated microlens on a GaN template. A photoresist array having hexagonal-closed packed microlens was fabricated on the GaN template. Then, optimization of etching the GaN template was performed using a dry etching process with ICP-RIE. The dry etching carried out using a gas mixture of Cl2 and Ar, each having a flow rate of 16 sccm and 10 sccm, respectively with RF power of 50 W, ICP power of 900 W and chamber pressure of 2 mTorr was the optimum etching condition as shown in Fig. 2(a).

  • PDF

Discharge Characteristics of Large-Area High-Power RF Ion Source for Neutral Beam Injector on Fusion Devices

  • Chang, Doo-Hee;Park, Min;Jeong, Seung Ho;Kim, Tae-Seong;Lee, Kwang Won;In, Sang Ryul
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.241.1-241.1
    • /
    • 2014
  • The large-area high-power radio-frequency (RF) driven ion sources based on the negative hydrogen (deuterium) ion beam extraction are the major components of neutral beam injection (NBI) systems in future large-scale fusion devices such as an ITER and DEMO. Positive hydrogen (deuterium) RF ion sources were the major components of the second NBI system on ASDEX-U tokamak. A test large-area high-power RF ion source (LAHP-RaFIS) has been developed for steady-state operation at the Korea Atomic Energy Research Institute (KAERI) to extract the positive ions, which can be used for the NBI heating and current drive systems in the present fusion devices, and to extract the negative ions for negative ion-based plasma heating and for future fusion devices such as a Fusion Neutron Source and Korea-DEMO. The test RF ion source consists of a driver region, including a helical antenna and a discharge chamber, and an expansion region. RF power can be transferred at up to 10 kW with a fixed frequency of 2 MHz through an optimized RF matching system. An actively water-cooled Faraday shield is located inside the driver region of the ion source for the stable and steady-state operations of RF discharge. The characteristics and uniformities of the plasma parameter in the RF ion source were measured at the lowest area of the expansion bucket using two RF-compensated electrostatic probes along the direction of the short- and long-dimensions of the expansion region. The plasma parameters in the expansion region were characterized by the variation of loaded RF power (voltage) and filling gas pressure.

  • PDF

Fabrication Processes and Properties of High Volume Fraction SiC Particulate Preform for Metal Matrix Composites (금속복합재료용 고부피분율 SiC분말 예비성형체의 제조공정과 특성)

  • 전경윤
    • Journal of Powder Materials
    • /
    • v.5 no.3
    • /
    • pp.184-191
    • /
    • 1998
  • The fabrication process and properties of SiC particulate preforms with high volume fraction above 50% were investigated. The SiC particulate preforms were fabricated by vacuum-assisted extraction method after wet mixing of SiC particulates of 48 ${\mu}m$ in diameter, $SiO_2$ as inorganic binder, cationic starch as organic binder and polyacrylamide as dispersant in distilled water. The SiC particulate preforms were consolidated by vacuum-assisted extraction, and were followed by drying and calcination. The drying processes were consisted with natural drying at $25^{\circ}C$ for 36 hrs and forced drying at 10$0^{\circ}C$ for 12 hrs in order to prevent the micro-cracking of SiC particulates preform. The compressive strengths of SiC particulate preforms were dependent on the inorganic binder content, calcination temperature and calcination time. The compressive strength of SiC preform increased from 0.47 MPa to 1.79 MPa with increasing the inorganic binder content from 1% to 4% due to the increase of $SiO_2$ flocculant between the interfaces of SiC particulates. The compressive strength of SiC preform increased from 0.90 MPa to 3.21 MPa with increasing the calcination temperatures from 800 to 120$0^{\circ}C$ under identical calcination time of 4hrs. The compressive strength of SiC preform increased from 0.92 to 1.95 MPa with increasing the calcination time from 2 hrs to f hrs at calcination temperature of 110$0^{\circ}C$. The increase of compressive strength of SiC preform with increasing the calcination temperature and time is due to the formation of crystobalite $SiO_2$ phase at the interfaces of SiC particulates.

  • PDF

Extraction of organic carbon from the condensate of food waste dry feed process (음식물류폐기물의 건식사료화 공정에서 발생되는 응축수로부터 유기탄소 추출)

  • Kim, Min-Kyung;Kwon, Ki-Wook;Mo, Kyung;Cui, Feng-Hao;Park, Se-Yong;Kim, Moon-Il
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.28 no.2
    • /
    • pp.41-48
    • /
    • 2020
  • In this study, organic carbon was extracted from the condensed water of food waste drying process to estimate the applicability as external organic carbon sources. The COD, TN, TP and TS of condensed water were 21,374 mg/L, 148 mg/L, 4.19 mg/L, and 455.7 mg/L, respectively. In addition, the content of biodegradable organics in condensed water was 47%. The fractional distillation and the vacuum evaporation were employed for extracting organic carbon. There were 8 extraction conditions, but 4 conditions were available for extraction. They were 1) 0mmHg, 110℃ 2) -600mmHg, 70℃ 3) -500mmHg, 80℃ 4) -600mmHg, 80℃. All 4 conditions showed the highest organic concentration and the highest quantity of organics when extracted 10% of initial volume. It was estimated that optimum conditions were 80℃, -600mmHg and 10% extraction. Then, extraction concentration, extraction quantity, extraction efficiency, extraction time, BOD/TCOD ratio, TVFAs/TCOD ratio and NH3-N were 174,200 mg/L, 8,710 mg, 46%, 10 min, 0.97, 0.74 and 75.5 mg/L respectively. Therefore, the extracted organic carbon can be utilized as external organic carbon sources.

Method for Drying of Crude Extract Obtained by Biomass Extraction Using an Ionic Liquid (이온성 액체를 이용한 바이오매스 추출에 의해 얻어진 추출물의 건조 방법)

  • Kim, Seul Ki;Kim, Jin-Hyun
    • Korean Chemical Engineering Research
    • /
    • v.54 no.3
    • /
    • pp.374-379
    • /
    • 2016
  • When using an ionic liquid as co-solvent, the extraction efficiency of anticancer agent paclitaxel from biomass was dramatically improved. However, the residual ionic liquid had a significant negative effect on convenient and feasibility of following concentration and drying steps. In this study, a novel method was developed for the effective drying of the crude extract obtained from biomass extraction with ionic liquid. The residual ionic liquid was easily and conveniently removed by drying alone after pre-treatment and additional washing of a sample with water. The optimal crude extract/water ratio and mixing time for pre-treatment and crude extract/water ratio for additional washing were 1:70 (w/v), 4 min, and 1:100 (w/v), respectively. In the microwave-assisted drying process, the drying time was 9-fold shorter than in the vacuum oven drying process.

Performance Evaluation of Soil Vapor Extraction Using Prefabricated Vertical Drain System (연직배수시스템을 이용한 토양증기추출공법의 성능 평가)

  • Shin, Eun-Chul;Park, Jeong-Jun
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.5
    • /
    • pp.9-18
    • /
    • 2007
  • Soil vapor extraction (SVE) is an effective and cost efficient method of removing volatile organic compounds (VOCs) and petroleum hydrocarbons from unsaturated soils. However, soil vapor extraction becomes ineffective in soils with low gas permeability, for example soils with air permeabilities less than 1 Darcy. Incorporating PVDs in an SVE system can extend the effectiveness of SVE to lower permeability soils by shortening the air flow-paths and ultimately expediting contaminant removal. The objective of the research described herein was to effectively incorporate PVDs into a SVE remediation system. The test results show that the gas permeability was evaluated for four different equivalent diameters, increasing the equivalent diameter results in a decrease in the calculated gas permeability. It was found that the porosity for the dry condition was greater than that of the wet condition and will allow flow rate for the same vacuum flow, offering a low resistance to the air flow.

Emission Characteristics of 0.7' Monochrome MOSFET-Controlled Field Emission Display in a High Vacuum Chamber

  • Lee, Jong-Duk;Oh, Chang-Woo;Kim, Il-Hwan;Park, Jae-Woo;Park, Byung-Gook
    • Journal of Information Display
    • /
    • v.2 no.3
    • /
    • pp.66-71
    • /
    • 2001
  • MCFEDs (MOSFET-Contoolled Field Emission Displays) were fabricated to evaluate the validity of MCFEA for display application. The electrical properties of FEAs (Field Emitter Arrays), HVMOSFETs (High-Voltage MOSFETs), and MCFEAs (MOSFET-Controlled Field Emitter Arrays) were measured. The extraction gate voltage of the FEAs to obtain the anode current of 10 nA/tip was around 71 V. The breakdown voltages of the HVMOSFETs were above 81 V for all the samples. The I-V characteristics of the MCFEAs showed that the emission currents of the FEAs were well controlled depending on the control gate voltages of the HVMOSFETs. To avoid the harmful effects during the packaging process, the performance of the MCFEDs was evaluated in a high vacuum chamber. The emission images of the MCFEDs were controlled through very-through operation. From the comparison with a conventional FED, it was proven that the poor uniformity of FED could be improved through the integration with HVMOSFET.

  • PDF