Noise Analyses of VVVF Inverter and DC/DC Converter for Maglev Train (자기부상열차용 VVVF 인버터 및 DC/DC 컨버터의 소음해석)

  • 김현실;김재승;강현주;김봉기;김상렬
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.5
    • /
    • pp.337-344
    • /
    • 2003
  • In DC/DC converter and VVVF inverter, which are the must dominant noise sources of Maglev train, noise is radiated from core and coil excited by MS(Magnetostriction). The main noise source of DC/DC converter is transformer whose spectrum shows strong peaks associated with harmonics of exciting frequency, On the other hand, LIM/VVVF noise is dominated by the harmonics of switching frequency, whereas harmonics of exciting frequency are not significant. As switching frequency is increased in VVVF inverter, it is shown that the harmonics are shifted to higher frequency range. If switching frequency is increased from 700㎐ to 2 ㎑, It is measured that noise can be reduced by 5 to 6 ㏈. Since complete mathematical description of MS phenomena is far beyond the present technology, vibration spectrum is investigated qualitatively in this paper, where effect of increasing switching frequency is confirmed.

A study on refurbishing VVVF Inverter for train of Busan metro line 2 (부산도시철도 2호선 VVVF 인버터 개량 연구)

  • Hwang, Hyun-Gyu;Park, Hee-Chul;Lee, Eun-Kyu;Kwon, Sun-Bum
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1407-1413
    • /
    • 2011
  • This paper studied on the VVVF Inverter for 1C4M propulsion system of railway traction. The paper includes the comparison along a VVVF Inverter electric power conversion element for an electric railcar(GTO, IGBT). These inverters are composed of high power IGBTs and controlled by compact control units. The stack is simplified and optimized by using plate bus and IGBT driver units of hybrid-type.

  • PDF

A Study On Field Test of IGBT Type Propulsion System for Electric Locomotive (전동차용 IGBT형 추진제어장치의 본선시험에 관한 연구)

  • 박건태
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.576-580
    • /
    • 2000
  • This paper describes about the field test of IGBT VVVF inverter for the propulsion system. The 1650kV class IGBT VVVF inverter has been developed. Therefore the field test is performed in SMG 6 Line to confirm its the reliability and performance. The train consists of 4M4T and the electrical equipment for field test are as follows : VVVF inverter 4 sets 16 traction motors and 3 SIVs The propulsion system which have the excellent acceleration/deceleration and the jerk chracteristics as well as starting ability on slope are taken through the field test.

  • PDF

A Study On Field Test of IGBT Type Propulsion System fo Electric oilway (전동차용 IGBT형 추진제어장치의 본선시험에 관한 연구)

  • 정만규;고영철;방이석;서광덕
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.5
    • /
    • pp.515-521
    • /
    • 2000
  • This paper describes the field test results of IGBT VVVF inverter for the railway propulsion system. The 1,650kVA IGBT VVVF inverter has been developed. Therefore, the field test is performed in SMG 6 Line to confirm its the reliability and performance. The train consists of 4M4T and the electrical equipment for field test are as follows : VVVF inverter 4 sets, 16 traction motors and 2 SIVs. The propulsion system is composed with 1C4M(1-Controller 4-Motors). The results of propulsion system which have the excellent acceleration/deceleration and the jerk characteristics as well as starting ability on slope are taken through the field test.

  • PDF

Data Acquisition and Analysis for Running Performance Evaluation of the Electric Train (전동차 주행성능평가를 위한 데이터취득 및 분석)

  • Lee, K.W.;Kim, M.Y.;Baik, K.S.;Shim, J.B.;Chang, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1099-1100
    • /
    • 2006
  • The running of the electric train are done by powering, breaking and coasting. Powering to start and accelerate the rolling stock means driving the three-phase electric induction motors controlled by VVVF inverters which are connected to overhead power line directly(DC) or indirectly(AC, DC/AC). Breaking is achieved by blending control which is the proportional combination between regenerative breaking of VVVF inverter and air pressure control of breaking operating unit(BOU). Therefore, Data obtained during two operation are very important items to evaluate the running performance of RS. This paper has investigated in real time data acquired from VVVF inverter and measured by pressure sensor directly connected to air breaking line(motor car and trailer car). By analyzing data in the region of time and frequency, fundamental methods for eavaluating the running performance of RS quantitatively and objectively have been suggested.

  • PDF

A Mock Running And Transient State Test of Propulsion VVVF Inverter for Electric Locomotive using A Inertia Load (관성부하를 이용한 전동차 추진용 VVVF 인버터의 모의주행 및 과도상태시험)

  • 정만규;서광덕
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.6
    • /
    • pp.491-499
    • /
    • 1999
  • This paper is on the high perfonnance propulsion IGBT VVVF inverter adopted new technique for railways. To prove the high performance and stabilit~r of traction, running tests are carried out under the simulated condition alike real field. The tests are perfonned on not only a steady states but also a transient states such a as input voltage variation using inertia load equivalent to 160tons train. The vector control technique is a adopted to improve traction for 4 motors. The low switching synchronous PW1\l method based on a space v voltage vector modulation is pro\XlSed as the optimal method for propulsion system railway. The output voltage l is controlled continuously to six step by prolxlsed ovennodu]ation technique without sudden torque variation.

  • PDF

A Study On Full Load Test of IGBT Type Propulsion System for Electric Railway in SMG 6 Line (전동차용 IGBT형 추진제어장치의 6호선 본선 만차 시험에 관한 연구)

  • 박건태;정만규;고영철;방이석;서광덕
    • Proceedings of the KSR Conference
    • /
    • 2000.11a
    • /
    • pp.666-673
    • /
    • 2000
  • This paper describes the full load test results of IGBT VVVF inverter for the railway propulsion system. The 1,650kVA IGBT VVVF inverter has been developed. Therefore, the field test is performed in SMG 6 Line to confirm its the reliability and performance. The train consists of 4M4T(4 Motor car 4 Trailer Car) and the electrical equipment for field test are as follows VVVF inverter 4 sets, 16 traction motors and 2 SIVs. The propulsion system is composed with IC4M(1-Controller 4-Motors). The results of propulsion system which have the excellent acceleration/deceleration and the jerk characteristics as well as starting ability on slope are taken through the field test.

  • PDF

PD Characteristics of inverter-fed AC motor subjected to impulse voltage in electric train (전동차내 임펄스 전압인가에 따른 인버터구동형 유도전동기의 PD 특성)

  • Lee, Kang-Won;Kim, Ryong-Myung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.564-565
    • /
    • 2005
  • AC induction motor equipped in electric train is driven by VVVF inverter which produces switching pulse like impuse. Impulse voltage is more dangerous than continuous alternative voltage for the insulating performance of AC induction motor. This paper has investigated PD characteristics caused by impuse voltage for stator coils inserted in AC induction motor.

  • PDF

A Study of Maglev Train Inverter and Conveter Noise (자기부상열차용 인버터 및 컨버터 소음에 관한 연구)

  • Kim, Hyun-Sil;Kim, Jae-Seung;Kang, Hyun-Joo;Kim, Bong-Ki;Kim, Sang-Rul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.339.1-339
    • /
    • 2002
  • Noise of the VVVF inverter and DC/DC converter, which are the most dominant noise sources of maglev train at low speed, is studied. The coils inside inverter and converter are excited by the electro-magnetic forces, which results in core vibration and generations of the noise. It is found that the spectra of the noise show many harmonics, where there exist several different fundamental frequencies. (omitted)

  • PDF

A Study of Maglev Train Inverter and Converter Noise (자기부상열차용 인버터 및 컨버터 소음에 관한 연구)

  • Kim, Hyun-Sil;Kim, Jae-Seung;Kang, Hyun-Joo;Kim, Bong-Ki;Kim, Sang-Rul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.346-351
    • /
    • 2002
  • Noise of the VVVF inverter and DC/DC converter, which are the most dominant noise sources of maglev train at low speed, is studied, The coils inside inverter and converter are excited by electro-magnetic forces, which results in core vibration and generations of the noise. It is found that the spectra of the noise show many harmonics, where there exist several different fundamental frequencies. Some noise reducing techniques are known for the transformer noise such as changing stiffness and using different core materials, which make less electrostatic responses, and consequently less noise. In this study, it is shown that the most effective and feasible noise reducing method is to increase the switching frequencies of the inverter and converter, where peaks in higher frequency are significantly reduced.