• Title/Summary/Keyword: VSI

Search Result 305, Processing Time 0.027 seconds

Detection and Diagnosis Solutions for Fault-Tolerant VSI

  • Cordeiro, Armando;Palma, Joao C.P.;Maia, Jose;Resende, Maia J.
    • Journal of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.1272-1280
    • /
    • 2014
  • This paper presents solutions for fault detection and diagnosis of two-level, three phase voltage-source inverter (VSI) topologies with IGBT devices. The proposed solutions combine redundant standby VSI structures and contactors (or relays) to improve the fault-tolerant capabilities of power electronics in applications with safety requirements. The suitable combination of these elements gives the inverter the ability to maintain energy processing in the occurrence of several failure modes, including short-circuit in IGBT devices, thus extending its reliability and availability. A survey of previously developed fault-tolerant VSI structures and several aspects of failure modes, detection and isolation mechanisms within VSI is first discussed. Hardware solutions for the protection of power semiconductors with fault detection and diagnosis mechanisms are then proposed to provide conditions to isolate and replace damaged power devices (or branches) in real time. Experimental results from a prototype are included to validate the proposed solutions.

A Study on the Development of Playback Control Software for Mark5B VSI System

  • Oh, S.J.;Yeom, J.H.;Roh, D.G.;Chung, H.S.;Kim, K.D.;Cappallo, Roger
    • Journal of Astronomy and Space Sciences
    • /
    • v.27 no.2
    • /
    • pp.107-116
    • /
    • 2010
  • We developed the playback control software for a high-speed playback system which is a component of the Korea-Japan Joint VLBI Correlator (KJJVC). The Mark5B system, which is a recorder and playback system used in the Korean VLBI Network (KVN), has two kinds of operation mode. That is to say, the station unit (SU) mode, which is for the present Mark4 system, and the VSI mode, which is for the new VLBI standard interface (VSI) system. The software for SU is already developed and widely used in the Mark4 type VLBI system, but the software for VSI has only been developed for recording. The new VLBI system is designed with a VSI interface for compatibility between different systems. Therefore, the playback control software development of the VSI mode is needed for KVN. In this work, we developed the playback control software of the Mark5B VSI mode. The developed playback control software consists of an application part for data playing back, a data input/output part for the VSI board, a module for the StreamStor RAID board, and a user interface part, including an observation time control part. To verify the performance of developed playback control software, the playback and correlation experiments were performed using the real observation data in Mark5B system and KJJVC. To check the observation time control, the data playback experiment was performed between the Mark5B and Raw VLBI Data Buffer (RVDB) systems. Through the experimental results, we confirmed the performance of developed playback control software in the Mark5B VSI mode.

A VSR $\bar{X}$ Chart with Multi-state VSS and 2-state VSI Scheme

  • Lee, Jae-Heon;Park, Chang-Soon
    • Journal of Korean Society for Quality Management
    • /
    • v.32 no.4
    • /
    • pp.252-264
    • /
    • 2004
  • Variable sampling Interval (VSI) control charts vary the sampling interval according to value of the control statistic while the sample size is fixed. It is known that control charts with 2-state VSI scheme, which uses only two sampling intervals, give good statistical properties. Variable sample size (VSS) control charts vary the sample size according to value of the control statistic while the sampling interval is fixed. In the VSS scheme no optimal results are known for the number of sample sizes. It is also known that the variable sampling rate (VSR) $\bar{X}$ control chart with 2-state VSS and 2-state VSI scheme leads to large improvements In performance over the fixed sampling rate (FSR) $\bar{X}$ chart, but the optimal number of states for sample size Is not known. In this paper, the VSR Χ charts with multi-state VSS and 2-state VSI scheme are designed and compared to 2-state VSS and 2-state VSI scheme. The multi-state VSS scheme is considered to, achieve an additional improvement by switching from the 2-state VSS scheme. On the other hand, the multi-state VSI scheme is not considered because the 2-state scheme is known to be optimal. The 3-state VSS scheme improves substantially the sensitivity of the $\bar{X}$ chart especially for small and moderate mean shifts.

Design and development of VSI Optical Adapter for high speed transmission of VLBI observation data (VLBI 관측데이터 초고속 전송을 위한 VSI 광변환 송수신 장치의 설계 및 개발)

  • Oh, Se-Jin;Roh, Duk-Gyoo;Yeom, Jae-Hwan;Jung, Jin-Seung;Jung, Dong-Kyu;Oh, Chung-Sik;Ozeki, Kensuke;Onuki, Hirofumi;Harada, Keniichi
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.14 no.4
    • /
    • pp.261-269
    • /
    • 2013
  • This paper describes the design and development of VSI (VLBI standard interface) optical adapter for transmitting VLBI(Very long baseline interferometry) observation data with optical signal. VSI cable comprised of 80-line is being used for observed data transmission with maximum length of 5-meter between playbacks (Mark5B, VERA2000) and raw VLBI data buffer (RVDB), RVDB and VLBI correlation subsystem (VCS) in Daejeon correlator. It has a plan to conduct the data processing for 16-stations and introduce the 14 RVDB systems in near future. And data loss frequently occurred because of trouble of VSI cable MDR80 connector. By considering the data loss by connector error of VSI cable, RVDB system extension plan, effective space usage and long distance data transmission(e-VLBI), the VSI optical adapter was proposed and developed for effectively transmitting and receiving VLBI data through optical signal. In order to confirming the performance of developed VSI optical adapter, the experiments for data transmission was conducted between playback and RVDB system, and confirmed that data transmission was clearly done without any data loss.

Comparison of DTC between two-level and three-level inverters for LV propulsion electric motor in ship (선박 추진용 저압 전동기에 대한 2레벨 및 3레벨 인버터의 직접토크제어 비교)

  • Ki-Tak RYU;Jong-Phil KIM;Yun-Hyung LEE
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.60 no.1
    • /
    • pp.71-79
    • /
    • 2024
  • In compliance with environmental regulations at sea and the introduction of unmanned autonomous ships, electric propulsion ships are garnering significant attention. Induction machines used as propulsion electric motor (PEM) have maintenance advantages, but speed control is very complicated and difficult. One of the most commonly used techniques for speed control is DTC (direct torque control). DTC is simple in the reference frame transformation and the stator flux calculation. Meanwhile, two-level and three-level voltage source inverters (VSI) are predominantly used. The three-level VSI has more flexibility in voltage space vector selection compared to the two-level VSI. In this paper, speed is controlled using the DTC method based on the specifications of the PEM. The speed controller employs a PI controller with anti-windup functionality. In addition, the characteristics of the two-level VSI and three-level VSI are compared under identical conditions. It was confirmed through simulation that proper control of speed and torque has been achieved. In particular, the torque ripple was small and control was possible with a low DC voltage at low speed in the three-level VSI. The study confirmed that the application of DTC, using a three-level VSI, contributes to enhancing the system's response performance.

Evaluating Properties of Variable Sampling Interval EWMA Control Charts for Mean Vector

  • Kwon, Yong-Man;Chang, Duk-Joon
    • Journal of the Korean Data and Information Science Society
    • /
    • v.16 no.3
    • /
    • pp.639-650
    • /
    • 2005
  • Theoretical and numerical comparison have shown that variable sampling interval (VSI) charts are substantially more efficient than fixed sampling interval(FSI) charts in term of ATS(average time to signal). But the frequency of switching between different sampling intervals is a complicating factor in VSI procedures. VSI EWMA charts for monitoring mean vector of related qualify characteristics are investigated. To compare the efficiencies of the proposed charts, the performances are evaluated for matched FSI and VSI charts in terms of average time to signal(ATS) and average number of samples to signal(ANSS). For the switching behavior of the proposed VSI charts, average number of switches(ANSW) are also investigated.

  • PDF

A Study about Space Vector PWM strategy For Three-Phase Four-Legged Voltage Source Inverter (3상 4레그 전압원 인버터(Three-Phase Four-Legged Voltage Source Inverter)의 공간벡터 전압변조 방식에 대한 연구)

  • Kim, Jang-Hwan;Sul, Seung-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.154-156
    • /
    • 2003
  • 3상 4레그(leg) VSI(Voltage Source Inverter)는 독립된 3개의 출력전압을 합성할 수 있다. 따라서 전압 합성에 있어서 3개의 자유도를 갖는다. 본 논문에서는 3상 4레그 VSI를 위한 PWM방법에 대해서 설명한다. 3상 4레그 VSI를 위한 기존의 PWM기술은 3-D SVPWM으로 그 구현 방법에 있어서 많은 양의 계산과 테이블을 필요로 하였다. 하지만, 본 논문에서 제안 한 방법은 3상 3레그 VSI경우에 적용되었던 옵셋(offset) 전압의 개념을 사용한다. 또한 단일 반송파를 이용하여 폴(Pole)전압과 비교함으로써 PWM을 구현하기 때문에 그 적응이 매우 간단하다. 본 논문에서는 기존의 3-D SVPWM과 제안한 방법이 해석적으로 동일한 방법임을 증명하였으며, 3상 4레그 VSI에서 합성가능한 3자유도의 전압범위를 계산하였다. 마지막으로 이를 실험을 통하여 검증하였다.

  • PDF

Variable Sampling Interval $\bar{X}$ Control Chart Using Weighted Standard Deviation Method (가중표준편차를 이용한 가변표본채취간격 $\bar{X}$ 관리도)

  • Chang, Youngsoon
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.39 no.1
    • /
    • pp.1-12
    • /
    • 2014
  • This article proposes a variable sampling interval (VSI) $\bar{X}$ control chart using weighted standard deviation (WSD) method for skewed populations. The WSD method decomposes the standard deviation of a quality characteristic into upper and lower deviations and adjusts control limits and warning limits of a control chart in accordance with the direction and degree of skewness. A control chart constant is derived for estimating the standard deviation of skewed distributions with the mean of sample standard deviations. The proposed chart is compared with the conventional VSI $\bar{X}$ control chart under some skewed distributions. Simulation study shows that the proposed WSD VSI chart can control the in-control average time to signal (ATS) as an adequate level better than the conventional VSI chart, and the proposed chart can detect a decrease in the process mean of a quality characteristic following a positively skewed distribution more quickly than the standard VSI chart.

Application of VSI-EBG Structure to High-Speed Differential Signals for Wideband Suppression of Common-Mode Noise

  • Kim, Myunghoi;Kim, Sukjin;Bae, Bumhee;Cho, Jonghyun;Kim, Joungho;Kim, Jaehoon;Ahn, Do Seob
    • ETRI Journal
    • /
    • v.35 no.5
    • /
    • pp.827-837
    • /
    • 2013
  • In this paper, we present wideband common-mode (CM) noise suppression using a vertical stepped impedance electromagnetic bandgap (VSI-EBG) structure for high-speed differential signals in multilayer printed circuit boards. This technique is an original design that enables us to apply the VSI-EBG structure to differential signals without sacrificing the differential characteristics. In addition, the analytical dispersion equations for the bandgap prediction of the CM propagation in the VSIEBG structure are extracted, and the closed-form expressions for the bandgap cutoff frequencies are derived. Based on the dispersion equations, the effects of the impedance ratio, the EBG patch length, and via inductances on the bandgap of the VSI-EBG structure for differential signals are thoroughly examined. The proposed dispersion equations are verified through agreement with the full-wave simulation results. It is experimentally demonstrated that the proposed VSI-EBG structure for differential signaling suppresses the CM noise in the wideband frequency range without degrading the differential characteristics.

Economic design of VSI ${\overline{X}}$-CRL Synthetic Control Chart (VSI ${\overline{X}}$-CRL 합성관리도의 경제적 설계)

  • Song, Suh-Ill;Park, Hyun-Kyu;Jung, Hey-Jin
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.28 no.4
    • /
    • pp.85-93
    • /
    • 2005
  • This paper is designed a VSI ${\overline{X}}$-CRL synthetic control chart in aspect of economy. We found the optimal sampling interval and various control limit factors under various cost parameters using cost function, proposed Lorenzen and Vance. Optimal design parameters include the sample size, control limit width, sampling interval, CRL/S chart control limit; L. Comparison and analysis of cost parameters are applied between synthetic VSI ${\overline{X}}$-CRL chart and FSI ${\overline{X}}$-CRL chart. The result of this paper shows that VSI ${\overline{X}}$-CRL chart brings cost-cutting effect of 3.04% control expense less than FSI control chart. It may not be difficult to establish the optimal economic control parameters to apply the practical cost parameters in the field.