• Title/Summary/Keyword: VP8

Search Result 273, Processing Time 0.033 seconds

Prevalence of Senecavirus A in pigs from 2014 to 2020: a global systematic review and meta-analysis

  • Xuhua Ran;Zhenru Hu;Jun Wang ;Zhiyuan Yang ;Zhongle Li ;Xiaobo Wen
    • Journal of Veterinary Science
    • /
    • v.24 no.3
    • /
    • pp.48.1-48.13
    • /
    • 2023
  • Background: Senecavirus A (SVA), a member of the family Picornaviridae, is newly discovered, which causes vesicular lesions, lameness in swine, and even death in neonatal piglets. SVA has rapidly spread worldwide in recent years, especially in Asia. Objectives: We conducted a global meta-analysis and systematic review to determine the status of SVA infection in pigs. Methods: Through PubMed, VIP Chinese Journals Database, China National Knowledge Infrastructure, and Wanfang Data search data from 2014 to July 26, 2020, a total of 34 articles were included in this analysis based on our inclusion criteria. We estimated the pooled prevalence of SVA in pigs by the random effects model. A risk of bias assessment of the studies and subgroup analysis to explain heterogeneity was undertaken. Results: We estimated the SVA prevalence to be 15.90% (1,564/9,839; 95% confidence interval [CI], 44.75-65.89) globally. The prevalence decreased to 11.06% (945/8,542; 95% CI, 28.25-50.64) after 2016. The highest SVA prevalence with the VP1-based RT-PCR and immunohistochemistry assay was 58.52% (594/1,015; 95% CI, 59.90-83.96) and 85.54% (71/83; 95% CI, 76.68-100.00), respectively. Besides, the SVA prevalence in piglet herds was the highest at 71.69% (119/166; 95% CI, 68.61-98.43) (p < 0.05). Moreover, our analysis confirmed that the subgroups, including country, sampling year, sampling position, detected gene, detection method, season, age, and climate, could be the heterogeneous factors associated with SVA prevalence. Conclusions: The results indicated that SVA widely exists in various countries currently. Therefore, more prevention and control policies should be proposed to enhance the management of pig farms and improve breeding conditions and the environment to reduce the spread of SVA.

Vertical root fracture diagnosis in teeth with metallic posts: Impact of metal artifact reduction and sharpening filters

  • Debora Costa Ruiz;Lucas P. Lopes Rosado;Rocharles Cavalcante Fontenele;Amanda Farias-Gomes;Deborah Queiroz Freitas
    • Imaging Science in Dentistry
    • /
    • v.54 no.2
    • /
    • pp.139-145
    • /
    • 2024
  • Purpose: This study examined the influence of a metal artifact reduction (MAR) tool, sharpening filters, and their combination on the diagnosis of vertical root fracture (VRF) in teeth with metallic posts using cone-beam computed tomography (CBCT). Materials and Methods: Twenty single-rooted human premolars - 9 with VRF and 11 without - were individually placed in a human mandible. A metallic post composed of a cobalt-chromium alloy was inserted into the root canal of each tooth. CBCT scans were then acquired under the following parameters: 8 mA, a 5×5 cm field of view, a voxel size of 0.085 mm, 90 kVp, and with MAR either enabled or disabled. Five oral and maxillofacial radiologists independently evaluated the CBCT exams under each MAR mode and across 3 sharpening filter conditions: no filter, Sharpen 1×, and Sharpen 2×. The diagnostic performance was quantified by the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity. These metrics were compared using 2-way analysis of variance with a significance level of α=5%. Intra- and inter-examiner agreement were assessed using the weighted kappa test. Results: Neither MAR nor the application of sharpening filters significantly impacted AUC or specificity (P>0.05). However, sensitivity increased when MAR was combined with Sharpen 1× and Sharpen 2× (P=0.015). The intra-examiner agreement ranged from fair to substantial (0.34-0.66), while the inter-examiner agreement ranged from fair to moderate (0.27-0.41). Conclusion: MAR in conjunction with sharpening filters improved VRF detection; therefore, their combined use is recommended in cases of suspected VRF.

Comparison of Exposure Dose by Using AEC Mode of Abdomen AP Study in Radiography (복부 전후 방향 검사의 자동노출제어 사용 시 선량 비교 연구)

  • Kim, Ki-Won;Kwon, Yong-Rak;Seo, Seong-Won;Kwon, Kyung-Tae;Oh, Joo-Young;Son, Soon-Yong;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.205-211
    • /
    • 2015
  • We evaluated the effectiveness of TL (Time Limit) method by comparing with NTL (Non-time limit) method when it is used for examinations for abdomen Anterior Posterior (AP) in this paper. The evaluation was conducted based on the comparison of dose, and of signal to noise ratio (SNR) and contrast to ratio (CNR) on both methods. The experiments were conducted with XGEO GC 80 (Samsung, Korea), Unfors ThinX RAD (Unfors, Sweden) and Rando Phantom (Alderson research laboratories, USA) and shielding material with the size of $5.5{\times}9{\times}0.1cm^3$. It was set to activate only two upper ionization chambers in automatic exposure control(AEC) mode and the tube-voltage was set to 80kVp. When the exposure time was limited, it is limited to 51 msec. The images both by NTL AEC method and TL AEC method were acquired when with and without attachment of shielding material on the upper ionization chambers. The images were evaluated by SNR and CNR which are the image evaluation methods using 'Image J'. The NTL AEC method showed increases in dose as much as 130.7% at maximum and 80% at minimum than other methods. The TL AEC method showed decreases in mAs and exposure dose than the NTL AEC method as much as 43.8% and 44.4% respectively. There were no significant differences in SNR or CNR for the experiments (($p{\geq}0.05$). Therefore, it is suggested that the TLAEC mode is more effective when examining patients who have high BMI index or a patient with a metallic substance in the body after surgery.

The Evaluation for Attenuation Map using Low Dose in PET/CT System (PET/CT 시스템에서 감쇠지도를 만들기 위한 저선량 CT 평가)

  • Nam, So-Ra;Cho, Hyo-Min;Jung, Ji-Young;Lee, Chang-Lae;Lim, Han-Sang;Park, Hoon-Hee;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.134-138
    • /
    • 2007
  • The current PET/CT system with high quality CT images not only increases diagnostic value by providing anatomic localization, but also shortens the acquisition time for attenuation correction than primary PET system. All commercially available PET/CT system uses the CT scan for attenuation correction instead of the transmission scan using radioactive source such as $^{137}Cs,\;^{68}Ge$. However the CT scan may substantially increase the patient dose. The purpose of this study was to evaluate quality of PET images reconstructed by CT attenuation map using various tube currents. in this study, images were acquired for 3D Hoffman brain phantom and cylindrical phantom using GE DSTe PET/CT system. The emission data were acquired for 10 min using phantoms after injecting 44.03 MBq of $^{18}F-FDG$. The CT images for attenuation map were acquired by changing tube current from 10 mA to 95 mA with fixed exposure time of 8 sec and fixed tube voltage of 140 kVp. The PET images were reconstructed using these CT attenuation maps. Image quality of CT images was evaluated by measuring SD (standard deviation) of cylindrical phantom which was filled with water and $^{18}F-FDG$ solution. The PET images were evaluated by measuring the activity ratio between gray matter and white matter in Hoffman phantom images. SDs of CT images decrease by increasing tube current. When PET images were reconstructed using CT attenuation maps with various tube currents, the activity ratios between gray matter and white matter of PET images were almost same. These results indicated that the quality of the PET images using low dose CT data were comparable to the PET images using general dose CT data. Therefore, the use of low dose CT is recommended than the use of general dose CT, when the diagnostic high quality CT is not required. Further studies may need to be performed for other system, since this study is limited to the GE DSTe system used in this study.

  • PDF

Metabolic syndrome in the overweight and obese adolescents and the impact of obesity on the cardiovascular system (과체중과 비만 청소년에서 대사증후군과 비만이 심혈관에 미치는 영향)

  • Hong, Young Mi;Song, Young Whan;Kim, Hae Soon;Park, Hae Sook;Min, Jung Hae;Jung, Jo Won;Kim, Nam Su;Noh, Chung Il
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.10
    • /
    • pp.1109-1118
    • /
    • 2009
  • Purpose : Metabolic syndrome (MS), characterized by obesity and insulin resistance, elicits risk factors such as hyperlipidemia, hypertension, and glucose intolerance with additive effects on atherosclerosis, leading to cardiovascular diseases. The purposes of this study were to evaluate the prevalence of MS among overweight and obese adolescents and to investigate the impact of obesity on the cardiovascular system. Methods : In all, 684 adolescents were included in the study. Blood pressure, body mass index (BMI), fasting blood glucose, total cholesterol, triglyceride, low-density-lipoprotein (LDL)-cholesterol, high-density-lipoprotein (HDL)-cholesterol, aspartate aminotransferase (AST), alanine aminotransferase (ALT), and high-sensitive C-reactive protein (hs-CRP) were measured in the patients with a BMI of >85 percentile. Brachial-ankle pulse wave velocity (BaPWV) and ankle brachial index were measured using Vascular Profiler (VP)-1000. Results : MS was confirmed in 19.5% of the overweight and obese adolescents and 50.8% of the obese adolescents. The systolic and diastolic blood pressure, height, weight, fat mass, %fat, BMI, obesity index, and waist circumference were higher in the overweight and obese adolescents with MS. Moreover, the triglyceride, AST, ALT, and hs-CRP levels were higher, whereas HDL-cholesterol level was significantly lower in this group. The overweight and obese adolescents with MS showed shorter diastolic and systolic times, higher heart rate and BaPWV, and longer E-wave deceleration time by echocardiography. Conclusion : Overweight and obese adolescents showed characteristic MS features such as hypertension and hyperlipidemia. Thus, obese adolescents predisposed to MS should be provided early treatment for obesity.

The Study of Affecting Image Quality according to forward Scattering Dose used Additional Filter in Diagnostic Imaging System (부가필터 사용 시 전방 산란선량에 따른 화질 영향에 대한 연구)

  • Choi, Il-Hong;Kim, Kyo-Tae;Heo, Ye-Ji;Park, Hyong-Hu;Kang, Sang-Sik;Noh, Si-Cheol;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.8
    • /
    • pp.597-602
    • /
    • 2016
  • Recent clinical field utilizes the aluminium filter in order to reduce the low-energy photons. However, the usage of the filter can cause adverse effect on the image quality because of the scattered dose that is generated by X-ray hardening phenomenon. Further, usage of filter with improper thickness can be a reason of dose creep phenomenon where unnecessary exposure is generated towards the patient. In this study, the author evaluated the RMS and the RSD analysis in order to have a quantitative evaluation for the effect of forward scattering dose by the filter on the image. as a result of the study, the FSR and the RSD was increased together with the increasing of thickness of the filter. In this study the RSD means the standard deviation of the mean value is relatively size. It can be understood that the signal-to-noise ratio decreases when the average value is taken as a signal and the standard deviation is judged as a noise. The signal-to-noise ratio can understanding as index of resolution at image. Based on these findings, it was quantitatively verified that there is a correlation of the image quality with the FSR by using an additional filter. The results, a 2.5 mmAl which is as recommended by NCRP in the tube voltage of 70 kVp or more showed the 14.6% on the RSD when the filter was not in used. these results are considered able to be utilized as basic data for the study about the filter to improve the quality of the image.

Reducing Dose in SPECT/CT Using Adaptive Statistical Iterative Reconstruction Technique (Adaptive Statistical Iterative Reconstruction 기법을 이용한 Bone SPECT/CT 검사에서 피폭량 감소 방안)

  • Choi, Jin-Wook;Choi, Hyeon-Jun;Park, Chan-Rok;Cho, Sung-Wook;Kim, Jin-Eui;Lee, Jae-Sung;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.134-139
    • /
    • 2014
  • Purpose: Adaptive statistical iterative reconstruction (ASIR) technique is a reconstruction method of CT image using statistical noise modeling which is known to reduce image noise and to preserve image quality despite reducing radiation dose. The aim of this study is to evaluate images using ASIR on bone SPECT/CT which is primarily performed in our hospital. Materials and Methods: We compared the images of applied ASIR (ASIR level: 20-80%) and none ASIR by changing the mA based on 120 kVp, 100 mA using Discovery NM/CT 670 (GE, U.S.A). First, we evaluated attenuation correction in SPECT image by changing the ASIR level using Anthropomorphic phantom. Second, we compared the contrast to noise ratio (CNR), image noise and spatial resolution in CT image using ACR phantom. Third, after selecting the ASIR level applicable patient using lower torso phantom, we examined 2 patients who followed up bone SPECT/CT and we performed blind test. Results: The degree of attenuation correction in SPECT image showed no significant difference between applied ASIR and none ASIR (P>0.05). When applied ASIR, the noise of CT image were reduced at least 17 up to 52% by changing the mA. The CNR of image with ASIR was maintained more than 0.8 at 40 mA (ASIR 60%) while those without ASIR showed 0.42 at standard 40 mA. In comparison of the high contrast object, we distinguished 12 line pairs/cm at 40 mA regardless of appling ASIR. Comparison of the patients image applied ASIR level 60% (40 mA) which found out by spine image of lower torso phantom showed no signigicant difference between applied ASIR and none ASIR in blind test. The CTDIvol and DLP for applied ASIR 60% showed decreased by 60%, 60% on average than using standard mA. Conclusion: The study show that the radiation dose in SPECT/CT using ASIR can be reduced despite degradation of SPECT and CT images. In addition, higher ASIR level could be possibly applied characteristics of SPECT/CT that region of interest is limited to bone.

  • PDF

Evaluating applicability of metal artifact reduction algorithm for head & neck radiation treatment planning CT (Metal artifact reduction algorithm의 두경부 CT에 대한 적용 가능성 평가)

  • Son, Sang Jun;Park, Jang Pil;Kim, Min Jeong;Yoo, Suk Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.107-114
    • /
    • 2014
  • Purpose : The purpose of this study is evaluation for the applicability of O-MAR(Metal artifact Reduction for Orthopedic Implants)(ver. 3.6.0, Philips, Netherlands) in head & neck radiation treatment planning CT with metal artifact created by dental implant. Materials and Methods : All of the in this study's CT images were scanned by Brilliance Big Bore CT(Philips, Netherlands) at 120kVp, 2mm sliced and Metal artifact reduced by O-MAR. To compare the original and reconstructed CT images worked on RTPS(Eclipse ver 10.0.42, Varian, USA). In order to test the basic performance of the O-MAR, The phantom was made to create metal artifact by dental implant and other phantoms used for without artifact images. To measure a difference of HU in with artifact images and without artifact images, homogeneous phantom and inhomogeneous phantoms were used with cerrobend rods. Each of images were compared a difference of HU in ROIs. And also, 1 case of patient's original CT image applied O-MAR and density corrected CT were evaluated for dose distributions with SNC Patient(Sun Nuclear Co., USA). Results : In cases of head&neck phantom, the difference of dose distibution is appeared 99.8% gamma passing rate(criteria 2 mm / 2%) between original and CT images applied O-MAR. And 98.5% appeared in patient case, among original CT, O-MAR and density corrected CT. The difference of total dose distribution is less than 2% that appeared both phantom and patient case study. Though the dose deviations are little, there are still matters to discuss that the dose deviations are concentrated so locally. In this study, The quality of all images applied O-MAR was improved. Unexpectedly, Increase of max. HU was founded in air cavity of the O-MAR images compare to cavity of the original images and wrong corrections were appeared, too. Conclusion : The result of study assuming restrained case of O-MAR adapted to near skin and low density area, it appeared image distortion and artifact correction simultaneously. In O-MAR CT, air cavity area even turned tissue HU by wrong correction was founded, too. Consequentially, It seems O-MAR algorithm is not perfect to distinguish air cavity and photon starvation artifact. Nevertheless, the differences of HU and dose distribution are not a huge that is not suitable for clinical use. And there are more advantages in clinic for improved quality of CT images and DRRs, precision of contouring OARs or tumors and correcting artifact area. So original and O-MAR CT must be used together in clinic for more accurate treatment plan.

Evaluation of Image Quality According to Presence or Absence of Upper limbs in Scan Field of View During CT Examinations (Including LUNG MAN) (CT 검사 시 스캔 범위 내 상지 유무에 따른 영상의 질 평가(LUNG MAN 포함))

  • Zhang, Yuying;Zheng, Haoyang;Jung, Kang-gyo;Cho, Yu-Jin;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.567-573
    • /
    • 2017
  • The purpose of this study was to evaluate whether or not there was artifact when the upper limb could not be lifted to the top of the head during multi-detector computed tomography(MDCT) scans of the chest and abdomen. Contrast radiography of the human and chest phantom was performed with 128channal MDCT. Under the same conditions(120 kVp, 110 mAs, standard algorithm)both hands lifted up and put down each time in the human experiment. In the chest phantom experiment, the radiography was carried out when the upper limb phantom was adjusted at a certain distance(0, 3, 7 cm) from the chest phantom. Subsequently, the values of Noise, CT number, SNR, and CNR were measured in the field of concern. The noise value of fat, rib, and muscle increased when the arm was lifted in humans(0.79, 47.8, 27%). Furthermore, when the upper limb was lowered, the noise value of muscle and lung increased in the phantom(31.2, 9.4%). In addition, the noise value of the muscles and lung decreased by 5, 25.12% and 5.6, 15.35% as the upper limb moved about 0,3,7cm away from the chest. When the chest and abdominal radiography were performed, in the case of the presence of other parts outside the inspection area, the probability of artifact was minimal while the distance was more than 3cm away from the upper limb to the chest and abdomen.

Principal component analysis in C[11]-PIB imaging (주성분분석을 이용한 C[11]-PIB imaging 영상분석)

  • Kim, Nambeom;Shin, Gwi Soon;Ahn, Sung Min
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.12-16
    • /
    • 2015
  • Purpose Principal component analysis (PCA) is a method often used in the neuroimagre analysis as a multivariate analysis technique for describing the structure of high dimensional correlation as the structure of lower dimensional space. PCA is a statistical procedure that uses an orthogonal transformation to convert a set of observations of correlated variables into a set of values of linearly independent variables called principal components. In this study, in order to investigate the usefulness of PCA in the brain PET image analysis, we tried to analyze C[11]-PIB PET image as a representative case. Materials and Methods Nineteen subjects were included in this study (normal = 9, AD/MCI = 10). For C[11]-PIB, PET scan were acquired for 20 min starting 40 min after intravenous injection of 9.6 MBq/kg C[11]-PIB. All emission recordings were acquired with the Biograph 6 Hi-Rez (Siemens-CTI, Knoxville, TN) in three-dimensional acquisition mode. Transmission map for attenuation-correction was acquired using the CT emission scans (130 kVp, 240 mA). Standardized uptake values (SUVs) of C[11]-PIB calculated from PET/CT. In normal subjects, 3T MRI T1-weighted images were obtained to create a C[11]-PIB template. Spatial normalization and smoothing were conducted as a pre-processing for PCA using SPM8 and PCA was conducted using Matlab2012b. Results Through the PCA, we obtained linearly uncorrelated independent principal component images. Principal component images obtained through the PCA can simplify the variation of whole C[11]-PIB images into several principal components including the variation of neocortex and white matter and the variation of deep brain structure such as pons. Conclusion PCA is useful to analyze and extract the main pattern of C[11]-PIB image. PCA, as a method of multivariate analysis, might be useful for pattern recognition of neuroimages such as FDG-PET or fMRI as well as C[11]-PIB image.

  • PDF