• Title/Summary/Keyword: VP2

Search Result 649, Processing Time 0.024 seconds

Tumorigenesis of Transgenic Mice Induced by Mouse Vasopressin-SV40 T Hybrid Oncogene

  • Lee, Eun-Ju;Kim, Myoung-Ok;Kim, Sung-Hyun;Park, Jun-Hong;Park, Jung-Ok;Cho, Kyong-In;Park, Hum-Dai;Ryoo, Zae-Young
    • Proceedings of the KSAR Conference
    • /
    • 2002.06a
    • /
    • pp.92-92
    • /
    • 2002
  • The neuropeptide vasopressin (VP) is a nine- amino acid hormone synthesized as preprohormone in the cell bodies of hypothalamic magnocellular neurons. The tumor in magnocellular neurons of the hypothalamus is associated with disfunctions of the cell bodies, leading to the diabetes insipidus. In order to produce the disease models with a defect in VP synthesis and its secretion, we have produced the transgenic mice regulated by VP constructs containing 3.8 kbp of the 5'flanking region and all the exons and introns in the mouse VP gene, which was fused at the end of exon 3 to a SV40 Tag. The two VP-transgene constructs differed by the lengths of their VP gene 3' flanking regions (2.1 versus 3.6 kbp). (omitted)

  • PDF

Development of a One-Step Duplex RT-PCR Method for the Simultaneous Detection of VP3/VP1 and VP1/P2B Regions of the Hepatitis A Virus

  • Kim, Mi-Ju;Lee, Shin-Young;Kim, Hyun-Joong;Lee, Jeong Su;Joo, In Sun;Kwak, Hyo Sun;Kim, Hae-Yeong
    • Journal of Microbiology and Biotechnology
    • /
    • v.26 no.8
    • /
    • pp.1398-1403
    • /
    • 2016
  • The simultaneous detection and accurate identification of hepatitis A virus (HAV) is critical in food safety and epidemiological studies to prevent the spread of HAV outbreaks. Towards this goal, a one-step duplex reverse-transcription (RT)-PCR method was developed targeting the VP1/P2B and VP3/VP1 regions of the HAV genome for the qualitative detection of HAV. An HAV RT-qPCR standard curve was produced for the quantification of HAV RNA. The detection limit of the duplex RT-PCR method was 2.8 × 101 copies of HAV. The PCR products enabled HAV genotyping analysis through DNA sequencing, which can be applied for epidemiological investigations. The ability of this duplex RT-PCR method to detect HAV was evaluated with HAV-spiked samples of fresh lettuce, frozen strawberries, and oysters. The limit of detection of the one-step duplex RT-PCR for each food model was 9.4 × 102 copies/20 g fresh lettuce, 9.7 × 103 copies/20 g frozen strawberries, and 4.1 × 103 copies/1.5 g oysters. Use of a one-step duplex RT-PCR method has advantages such as shorter time, decreased cost, and decreased labor owing to the single amplification reaction instead of four amplifications necessary for nested RT-PCR.

An Improvement Video Search Method for VP-Tree by using a Trigonometric Inequality

  • Lee, Samuel Sangkon;Shishibori, Masami;Han, Chia Y.
    • Journal of Information Processing Systems
    • /
    • v.9 no.2
    • /
    • pp.315-332
    • /
    • 2013
  • This paper presents an approach for improving the use of VP-tree in video indexing and searching. A vantage-point tree or VP-tree is one of the metric space-based indexing methods used in multimedia database searches and data retrieval. Instead of relying on the Euclidean distance as a measure of search space, the proposed approach focuses on the trigonometric inequality for compressing the search range, which thus, improves the search performance. A test result of using 10,000 video files shows that this method reduced the search time by 5-12%, as compared to the existing method that uses the AESA algorithm.

The unique role of domain 2A of the hepatitis A virus precursor polypeptide P1-2A in viral morphogenesis

  • Morace, Graziella;Kusov, Yuri;Dzagurov, Georgy;Beneduce, Francesca;Gauss-Muller, Verena
    • BMB Reports
    • /
    • v.41 no.9
    • /
    • pp.678-683
    • /
    • 2008
  • The initial step during assembly of the hepatitis A virus particle is driven by domain 2A of P1-2A, which is the precursor of the structural proteins. The proteolytic removal of 2A from particulate VP1-2A by an as yet unknown host enzyme presumably terminates viral morphogenesis. Using a genetic approach, we show that a basic amino acid residue at the C-terminus of VP1 is required for efficient particle assembly and that host proteases trypsin and cathepsin L remove 2A from hepatitis A virus particles in vitro. Analyses of insertion mutants in the C-terminus of 2A reveal that this part of 2A is important for liberation of P1-2A from the polyprotein. The data provide the first evidence that the VP1/2A junction is involved in both viral particle assembly and maturation and, therefore, seems to coordinate the first and last steps in viral morphogenesis.

Integer Inverse Transform Structure Based on Matrix for VP9 Decoder (VP9 디코더에 대한 행렬 기반의 정수형 역변환 구조)

  • Lee, Tea-Hee;Hwang, Tae-Ho;Kim, Byung-Soo;Kim, Dong-Sun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.4
    • /
    • pp.106-114
    • /
    • 2016
  • In this paper, we propose an efficient integer inverse transform structure for vp9 decoder. The proposed structure is a hardware structure which is easy to control and requires less hardware resources, and shares algorithms for realizing entire DCT(Discrete Cosine Transform), ADST(Asymmetric Discrete Sine Transform) and WHT(Walsh-Hadamard Transform) in vp9. The integer inverse transform for vp9 google model has a fast structure, named butterfly structure. The integer inverse transform for google C model, unlike universal fast structure, takes a constant rounding shift operator on each stage and includes an asymmetrical sine transform structure. Thus, the proposed structure approximates matrix coefficient values for all transform mode and is used to matrix operation method. With the proposed structure, shared operations for all inverse transform algorithm modes can be possible with reduced number of multipliers compared to the butterfly structure, which in turn manages the hardware resources more efficiently.

상부 Au 전극 면적 Size에 따른 PbI2 필름의 전기적 특성 평가

  • Myeong, Ju-Yeon;Park, Jeong-Eun;Kim, Dae-Guk;Kim, Gyo-Tae;Jo, Gyu-Seok;O, Gyeong-Min;Nam, Sang-Hui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.374-374
    • /
    • 2014
  • 의료용 X-ray는 과거 analog 방식과, 연구가 진행 중이며 현재 많이 사용되고 있는 digital 방식으로 나누어진다. 최근, 광도전체와 형광체 기반의 flat panel X-ray detector의 발전에 따른 상용화가 이루어지고 있으며, 많은 발전 가능성이 제기되고 있다. flat panel X-ray detector 검출방식은 direct method (직접 방식)와 indirect method (간접 방식)로 나누어진다. 본 연구는 일반적으로 상용화 되어있는 amorphous seleinum (비정질 셀레늄)의 큰 일함수에 의한 저 해상력이라는 단점을 보완하기 위해, 작은 일함수를 가지는 물질을 사용하여, 영상을 얻을 시에 높은 해상력으로 표현할 수 있도록 하고, 원자번호가 높은 물질을 사용하여 X-ray 흡수율을 높일 수 있도록 기존 direct method에 많이 사용되고 있는 amorphous seleinum 기반 digital X-ray detector가 아닌, 이러한 장점을 충족시킬 수 있는 PbI2 물질 층을 사용하여 시편을 제작 하였다. PbI2를 같은 두께로 올린 후, 물질 층 상부에 Au 전극 면적을 다른 size로 제작한 시편으로 X-ray에 노출 시켰다. 이는 상부 전극 size 차이에 따른 신호 차이를 측정하여 전기적 특성을 평가하기 위한 것이다. 전도성을 띠고 있는 ITO (Indium - Tin - Oxide) glass를 이용하여 screen printing 방법으로 제작하였다. PbI2층을 약 160~180 um두께, $3cm{\times}3cm$ size로 5개 제작하였으며, 상부 전극으로는 Au를 진공 증착 시켰다. 상부 전극 size는 각각 시편 5개에 $0.5cm{\times}0.5cm$, $1cm{\times}1cm$, $1.5cm{\times}1.5cm$, $2cm{\times}2cm$, $2.5cm{\times}2.5cm$로 PbI2 물질 층 중앙에 증착 시켰다. 이러한 설정으로 X-ray 노출 시 관찰할 수 있는 PbI2의 전기적인 특성을 평가할 수 있었다. 관전압을 40 kVp, 60 kVp, 80 kVp, 100 kVp, 120 kVp, 140 kVp로 설정하고, 관전류는 100 mA로 설정하였으며, Dark current, Sensitivity를 측정하였다. Dark current와 Sensitivity를 측정한 뒤, 그 값을 이용하여 SNR (신호 대 잡음 비)값을 구해보았다.실험 결과 단위면적당 signal과 SNR을 분석할 수 있었다. 80 kVp로 기준을 잡고 결과 값을 보면 $0.5cm{\times}0.5cm$ 시편에서 2.92 nC/cm2, $2.5cm{\times}2.5cm$ 시편에서 0.84 nC/cm2로 상부 전극 크기가 작을수록 더 좋은 신호를 측정할 수 있었다. 똑같은 기준에서 SNR을 계산 해 보았을 때, $0.5cm{\times}0.5cm$ 시편에서 6.46, $2.5cm{\times}2.5cm$ 시편에서 1.91로 SNR역시 상부 전극 크기가 작을수록 더 큰 값을 확인할 수 있었다. 이러한 결과는 edge-effect의 영향으로 인해 나온 결과라고 할 수 있다. 이러한 실험 결과, detector 제작 시, 같은 물질을 사용하여 더 높은 효율을 내기 위해서는 큰 size의 상부 전극 보다는 작은 size의 상부 전극을 증착 시키는 것이 전기적 특성을 더욱 효율적으로 평가할 수 있을 것이라고 사료된다.

  • PDF

Sequence analysis of the hypervariable region in VP2 gene of infectious bursal disease vaccine strains (Infectious bursal disease 백신주의 VP2 gene의 hypervariable region 분석)

  • Park, Yoo-jin;Kim, Soo-joung;Kwon, Hyuk-moo
    • Korean Journal of Veterinary Research
    • /
    • v.41 no.3
    • /
    • pp.333-342
    • /
    • 2001
  • To detect the genetic variations among infectious bursal disease (IBD) vaccine strains, the hypervariable region of VP2 gene of seven IBDV vaccine strains were amplified using reverse transcriptase/polymerase chain reation(RT/PCR). Ampllified PCR products of IBDV were cloned, sequenced, and compared with published sequences for IBDV. Vaccine strains (JOONG, HAN, B7, IB, BU2, G2, CIL) used in Korea and Korean field isolates (SH/92, K1, 310) had 81%(310 and HAN) ~ 98%(SH/92 and CIL) amino acid sequence similarity. Vaccine strains had 80%(HAN and IB) ~ 99%(JOONG and BU2) amino acid sequence similartiy. Intermediate plus vaccine strain, CIL was not substituted at positions 279(D $\rightarrow$ N) and 284(A $\rightarrow$ T), and conserved in serine-rich heptapeptide. At the two hydrophilic region, JOONG, IB and Bu2 strains had identical amino acid sequence comparing with STC strain. By phylogenetic analysis, JOONG and DAE strains were categorized in same group with BU2. The CIL and STC strains closely related but seperated from G2, HAN, B7 and IB strains.

  • PDF

The Evaluation of the Radiation Dose and Image Quality Through the Change of the Tube Voltage in Cerebral CT Angiography (전산화단층촬영장치를 이용한 뇌 혈관조영 검사에서 관전압 변화에 따른 방사선량과 영상의 질 평가)

  • LEE, Ji-Won;Jung, Kang-Kyo;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.121-126
    • /
    • 2015
  • To image diagnosis in neurovascular diseases using Multi-Detector Computed Tomography(MDCT), injected the same contrast material when inspecting Brain Computed Tomography Angiography(BCTA) to examine radiation dose and Image quality on changing Cerebral Artery CT number by tube voltage. Executed an examination with same condition[Beam Collimation $128{\times}0.6mm$, Pitch 0.6, Rotation Time 0.5s, Slice Thickness 5.0mm, Increment 5.0mm, Delay Time 3.0sec, Care Dose 4D(Demension ; D)] except for tube voltage on 50 call patients for BCTA and divided them into two groups (25 people for a group, group A: 80, group B: 120kVp). From all the acquired images, set a ROI(Region of Interest) on four spots such as left cerebral artery, right cerebral artery, posterior cerebral artery and cerebral parenchyma to compare quantitative evaluation, qualitative evaluation and effective dose after measuring CT number value from Picture Archiving Communications System(PACS). Evaluating images with CT number acquired from BCTA examination, images with 80 kVp was 18% higher in Signal to Noise Ratio and 19% in Contrast to Noise Ratio than those with 120 kVp. It was seen that expose dose was decreased by over 50% with tube voltage 80 kVp than with 120 kVp. Group A (25 patients) was examination with tube voltage 80kVp while group B with 120 kVp to examine radiation dose and Image quality. It is considered effective to inspect with lower tube voltage than with conventional high kVp, which can reduce radiation dose without any affect on diagnosis.

Influence of Blockade of Sympathetic Nervous System, Renin-Angiotensin System, and Vasopressin System on Basal Blood Pressure Levels and on Pressor Response to Norepinephrine, Angiotensin II, and Vasopressin (교감신경계, Renin-Angiotensin계, Vasopressin계의 차단이 혈압 및 Norepinephrine, Angiotensin II 및 Vasopressin의 승압효과에 미치는 영향)

  • Chung, Haeng-Nam
    • The Korean Journal of Pharmacology
    • /
    • v.28 no.1
    • /
    • pp.61-74
    • /
    • 1992
  • Influence of the blockade of the three major pressor systems-sympathetic nervous system (SNS), renin-angiotensin system (RAS) and vasopressin system-on the pressor responsiveness to norepinephrine (NE), angiotensin II (AII), and vasopressin (VP) as well as on basal blood pressure (BP) levels was investigated in urethane-anesthetized rabbits. To block the SNS and RAS, chlorisondamine (CS) and pirenzepine (PZ), sympathetic ganglionic blockers, and enalapril (ENAL), an inhibitor of angiotensin converting enzyme, respectively were used. And for suppressing the VP system bremazocine (BREM), a kappa opiate receptor agonist shown to suppress plasma levels of VP, was employed. Each of CS (0.4 mg/kg), ENAL (2 mg/kg), and BREM (0.25 mg/kg) produced almost same levels of steady hypotensive state. The hypotensive effect of BREM was significantly attenuated by desmopressin, a synthetic VP-like analogue, suggesting the hypotension being at least in part due to suppression of plasma levels of VP. CS, ENAL and BREM elicited further fall of the BP which had been lowered by ENAL or BREM, CS or BREM, and CS or ENAL, respectively. The hypotension produced by both CS and PZ together with either of ENAL or BREM was more marked than that produced by the three drugs other than CS. CS potentiated the pressor response not only to NE but to AII and VP. The pressor effect of AII was increased by ENAL and BREM, too. The pressor response to VP was also enhanced by BREM. Blockade of ${\alpha}-adrenergic$ receptors with phentolamine or phenoxybenzamine potentiated the pressor response to AII and that to VP. The results on basal BP levels indicate that the three major pressor systems are all participating in control of BP, but SNS has the greatest potential for supporting BP. The finding that blockade of one of the pressor systems induced enhanced pressor responsiveness to the pressor hormone of that particular system as well as to the pressor hormone(s) of the other systems(s) provides evidence for important interactions among the three major pressor systems.

  • PDF

Evaluation of Image According to Exposure Conditions using Contrast-Detail Phantom for Chest Digital Radiography (흉부 디지털 방사선 촬영 시 C-D phantom을 이용한 촬영조건에 따른 영상 평가)

  • Lee, In-Ja;Kim, You-Hyun;Kim, Chang-Nam;Lee, Chang-Yeob;Park, Kye-Yeon
    • Journal of radiological science and technology
    • /
    • v.32 no.1
    • /
    • pp.25-32
    • /
    • 2009
  • To find out proper photographing conditions in the chest DR imaging, the evaluation of images using the C-D phantom was carried out on relationship of identification capability, graininess, and exposure ratio. The conclusions were obtained as follows. 1. The patient's entrance skin Exposure (ESE) was decreased as tube voltage was increased. 2. According to the tube voltage change, the C-D phantom's identification capability of the exposure conditions was most visible at 110 kVp. 3. The identification capability according to the exposure ratio (mAs) change was most visible at 90 kVp for 0.5 times of low exposure ratio and at 110 kVp for 1.5 times. Therefore, it is known that the images were able to be better identified at a high exposure than a low exposure. 4. The graininess according to the exposure ratio at tube voltage of 110 kVp resulted in the best thing at 1.5 times of ratio when the exposure ratio was 1.5 times increased and the tube voltage was changed, the graininess showed the best result at 110 kVp. Therefore, the patient's exposure dose was low when kVp was increased and the adequate kVp was found to be 110. The image was better identified when exposure ratio was 1.5 times compared to 1.0 times. The graininess was also good when the exposure ratio became 1.5 times. The tube voltage was good at 110 kVp. However, once the exposure ratio is increased, the amount of radiation dose that the patients received get increased, so that the exposure condition has to be thoroughly considered.

  • PDF