• 제목/요약/키워드: VP16

Search Result 145, Processing Time 0.03 seconds

Influence of CBCT parameters on image quality and the diagnosis of vertical root fractures in teeth with metallic posts: an ex vivo study

  • Larissa Pereira Lagos de Melo;Polyane Mazucatto Queiroz;Larissa Moreira-Souza;Mariana Rocha Nadaes;Gustavo Machado Santaella;Matheus Lima Oliveira;Deborah Queiroz Freitas
    • Restorative Dentistry and Endodontics
    • /
    • v.48 no.2
    • /
    • pp.16.1-16.11
    • /
    • 2023
  • Objectives: The aim of this study was to evaluate the influence of peak kilovoltage (kVp) and a metal artifact reduction (MAR) tool on image quality and the diagnosis of vertical root fracture (VRF) in cone-beam computed tomography (CBCT). Materials and Methods: Twenty single-rooted human teeth filled with an intracanal metal post were divided into 2 groups: control (n = 10) and VRF (n = 10). Each tooth was placed into the socket of a dry mandible, and CBCT scans were acquired using a Picasso Trio varying the kVp (70, 80, 90, or 99), and the use of MAR (with or without). The examinations were assessed by 5 examiners for the diagnosis of VRF using a 5-point scale. A subjective evaluation of the expression of artifacts was done by comparing random axial images of the studied protocols. The results of the diagnoses were analyzed using 2-way analysis of variance and the Tukey post hoc test, the subjective evaluations were compared using the Friedman test, and intra-examiner reproducibility was evaluated using the weighted kappa test (α = 5%). Results: The kVp and MAR did not influence the diagnosis of VRF (p > 0.05). According to the subjective classification, the 99 kVp protocol with MAR demonstrated the least expression of artifacts, while the 70 kVp protocol without MAR led to the most artifacts. Conclusions: Protocols with higher kVp combined with MAR improved the image quality of CBCT examinations. However, those factors did not lead to an improvement in the diagnosis of VRF.

Comparisons of Image Quality and Entrance Surface Doses according to Care Dose 4D + Care kV in Chest CT (Chest CT에서 Care Dose 4D+Care kV에 따른 화질과 입사표면선량 비교)

  • Kang, Eun-Bo
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.1
    • /
    • pp.45-51
    • /
    • 2022
  • This study compared DLP values along with phantom entrance surface doses and the image quality of chest CT scans made using a Care Dose 4D+Care kV System, scans that are made using only the Care Dose 4D function, and scans that are made with changes made by applying 80 kVp, 100 kVp, 120 kVp, and 140 kVp to the Care Dose 4D and tube voltage to search for methods to maintain the highest image quality with minimal patient doses. It was shown that DLP values decreased 6.727% when scans were taken with Chest Care Dose 4D + Care kV semi 100 and 6.481% when scans were taken with Chest Care Dose 4D + Care kV. With Chest Non as a standard, skin surface doses decreased 16.519% when scans were taken with Chest Care Dose 4D + Care kV semi 100 and 15.705% when scans were taken with Chest Care Dose 4D + Care kV. With comparisons of image quality, when comparisons were made with Chest Non, comparisons made of SNR values and CNR values in all scanning conditions including Care Dose 4D + Care kV showed that there were no significant differences at P>0.05. Imaging using Chest Care Dose 4D + Care kV in chest CT showed that exposure doses decreased similarly to result values gained from the best conditions through manual adjustments of kV and mAS, and there were no significant differences in image SNR and CNR. If the Chest Care Dose 4D + Care kV function is used, image quality is maintained and patient exposure to radiation can be reduced.

Evaluation of Image Quality in Low Tube-Voltage Chest CT Scan (흉부 CT 검사 시 저 관전압 영상의 화질평가에 관한 연구)

  • Kim, Hyun-Ju;Cho, Jae-Hwan;Park, Cheol-Soo
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.4
    • /
    • pp.135-141
    • /
    • 2010
  • Purpose : The patients who visited this department for pulmonary disease and need CT scans for Follow-up to observe change of CT value, evaluation of image quality and decrease of radiation dose as change of kVp. Subjects and Methods : Subjects were the patients of 20 persons visited this department for pulmonary disease and Somatom Sensation 16(Semens, Enlarge, Germany) was used. Measurement of CT value as change of kVp was done by setting up ROI diameter of 1cm at the height of thyroid, aortic arch, right pulmonary artery in arterial phase image using 100 kVp, measuring 3 times, and recorded the average. CT value of phantom was measured by scanning phantoms which means contrast media diluted by normal saline by various ratio with tube voltage of 80 kVp, 100 kVp, 120 kVp, 140 kVp and recorded the average of 3 CT values of center of phantom image. In analysing radiation dose, CTDIVOL values of the latest arterial phase image of 120 kVp and as this research set that of 100 kVp were analyzed comparatively. 2 observers graded quality of chest images by 5 degrees (Unacceptable, Suboptimal, Adequate, Good, Excellent). Results : CT value of chest image increased at 100 kVp by 14.06%~27.26% in each ROI than 120 kVp. CT value of phantom increased as tube voltage lowered at various concentration of contrast media. CTDIVOL decreased at 100 kVp(5.00 mGy) by 36% than 120 kVp(7.80 mGy) in radiation dose analysis. here were 0 Unacceptable, 1 Suboptimal, 3 Adequate, 10 Good, 6 Excellent in totally 20 persons. Conclusion : Chest CT scanning with low kilo-voltage for patients who need CT scan repeatedly can bring images valuable for diagnose, and decrease radiation dose against patients.

A Study on the Preparation of Carboxylated Polysulfone/MeVpI-DVB Membranes and Its Characteristics (Carboxylated Polysulfon/MeVpl-DVB 막의 제조와 특성에 관한 연구)

  • 김관식;전경용;조영일
    • Membrane Journal
    • /
    • v.5 no.1
    • /
    • pp.26-34
    • /
    • 1995
  • In this study, polysulfone was carboxylated(CPSf), as a method of introducing carboxyl group to polymer main chain using direct lithiation reaction. Then, poly(1-alkyl-4-vinylpyridinium iodide-co-divinylbenzene) (MeVpI-DVB) containing pyridinium cation which has an anion selectivity as a fixed carrier was synthesized. And polymer membranes were prepared by mixing CPSf and MeVpI-DVB. Characteristics and permeation of membranes were investigated. As a result of synthesizing CPSf/MeVpI-DVB, blend was formed, not new copolymer. As the content of CPSf amount increasing, thermal stability of membranes was increasing. Ion exchange capacity was 1.0~1.8(meq/g dry mem.) and water content was 0.16~0.26(g $H_2{O}$)/g dry mem.) and fixed ion concentration was 6.4~7.3(meq/g $H_2{O}$) in synthetic membranes. The $Cl^-$ flux showed an increase due to the increase of CPSf content.

  • PDF

Analysis of antigenic sites on the VP4 of porcine rotavirus, Gottfried strain (돼지 로타바이러스(Gottfried 주)의 VP4 항원구조분석)

  • Song, Yun-kyung;Kim, Won-yong;Kang, Shien-young
    • Korean Journal of Veterinary Research
    • /
    • v.41 no.3
    • /
    • pp.343-350
    • /
    • 2001
  • The neutralization epitopes of the outer capsid protein VP4 of a porcine rotavirus, Gottfried strain, were studied using neutralizing monocolonal antibodies(N-MAbs). Eight N-MAbs which are specific for the VP4 of Gottfried strain were used for analyzing the antigenic sites of VP4. Three different approaches were used for this analysis; i)testing the serological reactivity of each N-MAb against different G and P types of human and animal rotavirusese ii) analyzing N-MAb-resistant viral escape mutants and iii) performing nucleotide sequence analysis of the VP4 gene of each N-MAb-resistant viral escape mutant. From experimental results, at least four antigenic sites(I, II, III, and IV) were identified. Antigenic site I recognized by N-MAbs 24B9, 23G10, and 26A2 was separated from antigenic site II recognized by N-MAbs 30H5, 32B3, and 29B3. However, these antigenic sites were overlapped with antigenic site III recognized by N-MAb 21A1. The other antigenic site IV recognized by N-MAb 16D2 was separated from antigenic sites I, II, and III.

  • PDF

Resistance against white spot syndrome virus (WSSV) infection in wild marine crab Gaetice depressus by injection of recombinant VP28 protein

  • Kim, Chun Soo;Choi, Seung Hyuk;Kim, Min Sun;Kim, Ki Hong
    • Journal of fish pathology
    • /
    • v.27 no.1
    • /
    • pp.11-16
    • /
    • 2014
  • The resistance against white spot syndrome virus (WSSV) infection in wild marine crab Gaetice depressus by the immunization of a recombinant glutathione-S-transferase (GST) fused VP28 protein (GST-VP28) was evaluated. The cumulative mortalities of GST-VP28 injected groups were lower than those of the control groups at 10 days of post-challenge, and the time to death of 50% crab ($TD_{50}$) was delayed by the immunization using GST-VP28. The group boosted with GST-VP28 after 2 weeks of primary immunization clearly showed longer $TD_{50}$ than non-boosted group against challenge with WSSV. This result suggests that boosting with the antigen protein elicit stronger immune responses similar to adaptive immune responses of vertebrates. However, the short $TD_{50}$ was observed in the group challenged at 3 weeks post boosting comparing to the group challenged at 1 week post boosting. This suggests that the protective strength of immunization decreased by the time.

Da-125 a New Antitumor Agent, Inhibits Topoisomerase II as Topoisomerase Poison and DNA Intercalator Simultaneously

  • Seo, Jin-Wook;Lee, Hak-Sung;Lee, Min-Jun;Kim, Mi-Ra;Shin, Cha-Gyun
    • Archives of Pharmacal Research
    • /
    • v.27 no.1
    • /
    • pp.77-82
    • /
    • 2004
  • DA-125, a novel derivative of adriamycin, is known for its anti-cancer activity. In this study, the inhibitory mechanism of DA-125 on topoisomerase was investigated in the simian virus 40 (SV40) replicating CV-1 cell by studying the SV40 DNA replication intermediates and DNA-topoisomerase complexes. DNA-protein complexes that were formed in the drug-treated cells were quantitated by using a glass filter assay. SV40 DNA replication intermediates that were accumulated in the drug-treated CV-1 cell were analyzed in a high resolution gel. DA-125 did not accumulate B-dimers of SV40 DNA replication intermediates which were found in the adriamycin-treated CV-1 cells. DA-125 induced a dose-dependent formation of the DNA-protein complexes, while adriamycin did not. When adriamycin and etoposide (VP16) were added to the SV40-infected cells at the same time, adriamycin blocked the formation of the DNA-protein complexes induced by VP16 in a dose-dependent manner. However, DA-125 blocked the formation of the DNA-protein complexes induced by VP16 up to the maximum level of the DNA-protein complexes that were induced by DA-125 alone. Adriamycin and DA-125 did not inhibit the formation of the DNA-protein complexes that were caused by camptothecin, a known topoisomerase I poison. DA-125 is bifunctional in inhibiting topoisomerase II because it simultaneously has the properties of the topoisomerase II poison and the DNA intercalator. As a topoisomerase II poison, DA-125 alone induced dose-dependent formation of the DNA-protein complexes. However, as a DNA intercalator, it quantitatively inhibited the formation of the DNA-protein complexes induced by a strong topoisomerase II poison VP16. Furthermore considering that the levels of the DNA-protein complex induced by VP16 were decreased by DA-125 in terms of the topoisomerase II poison, we suggest that DA-125 has a higher affinity to the drug-binding sites of DNA than VP16 has.

Estrogen receptor is downregulated by expression of HIF-1a/VP16

  • Cho, Jung-Yoon;Lee, Young-Joo
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.228.2-229
    • /
    • 2003
  • Estrogen Receptor is a ligand-activated transcription factor. The concentration of the receptor is a major component that regulates expression of estrogen-responsive genes. We have studied mechanism of estrogen receptor alpha (ER${\alpha}$) downregulation by HIF-1 using HIF-1${\alpha}$/VP16 constructs. ER${\alpha}$ is known to be downregulated under hypoxic condition. Transcriptional response under hypoxia is mediated through Hypoxia-inducible factor-1 (HIF-1), a transcription factor that is usullaly degraded but stabilized under hypoxia. (omitted)

  • PDF

Evaluation and Verification of the Attenuation Rate of Lead Sheets by Tube Voltage for Reference to Radiation Shielding Facilities (방사선 방어시설 구축 시 활용 가능한 관전압별 납 시트 차폐율 성능평가 및 실측 검증)

  • Ki-Yoon Lee;Kyung-Hwan Jung;Dong-Hee Han;Jang-Oh Kim;Man-Seok Han;Jong-Won Gil;Cheol-Ha Baek
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.489-495
    • /
    • 2023
  • Radiation shielding facilities are constructed in locations where diagnostic radiation generators are installed, with the aim of preventing exposure for patients and radiation workers. The purpose of this study is seek to compare and validate the trend of attenuation thickness of lead, the primary material in these radiation shielding facilities, at different maximum tube voltages by Monte Carlo simulations and measurement. We employed the Monte Carlo N-Particle 6 simulation code. Within this simulation, we set a lead shielding arrangement, where the distance between the source and the lead sheet was set at 100 cm and the field of view was set at 10 × 10 cm2. Additionally, we varied the tube voltages to encompass 80, 100, 120, and 140 kVp. We calculated energy spectra for each respective tube voltage and applied them in the simulations. Lead thicknesses corresponding to attenuation rates of 50, 70, 90, and 95% were determined for tube voltages of 80, 100, 120, and 140 kVp. For 80 kVp, the calculated thicknesses for these attenuation rates were 0.03, 0.08, 0.21, and 0.33 mm, respectively. For 100 kVp, the values were 0.05, 0.12, 0.30, and 0.50 mm. Similarly, for 120 kVp, they were 0.06, 0.14, 0.38, and 0.56 mm. Lastly, at 140 kVp, the corresponding thicknesses were 0.08, 0.16, 0.42, and 0.61 mm. Measurements were conducted to validate the calculated lead thicknesses. The radiation generator employed was the GE Healthcare Discovery XR 656, and the dosimeter used was the IBA MagicMax. The experimental results showed that at 80 kVp, the attenuation rates for different thicknesses were 43.56, 70.33, 89.85, and 93.05%, respectively. Similarly, at 100 kVp, the rates were 52.49, 72.26, 86.31, and 92.17%. For 120 kVp, the attenuation rates were 48.26, 71.18, 87.30, and 91.56%. Lastly, at 140 kVp, they were measured 50.45, 68.75, 89.95, and 91.65%. Upon comparing the simulation and experimental results, it was confirmed that the differences between the two values were within an average of approximately 3%. These research findings serve to validate the reliability of Monte Carlo simulations and could be employed as fundamental data for future radiation shielding facility construction.