• Title/Summary/Keyword: VP1

Search Result 662, Processing Time 0.041 seconds

The Study of Energy Compensation Filter Thickness for Each Energy Area of Low Energy X-ray Beam Optimization on Active Electronic Personal Dosimeter (능동형 전자식 개인피폭선량계의 저에너지 X선 영역별 최적화를 위한 에너지보상 필터 두께에 대한 연구)

  • Kim, Jung-Su;Park, Youn-Hyun;Chae, Hyun-Sic
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.5
    • /
    • pp.519-526
    • /
    • 2022
  • Electronic personal dosimeter (EPD) provide real time monitoring and a direct indication of the accumulated dose or dose rate in terms of personal dose. Most EPD do not perform well in low energy photon radiation fields present in medical radiation environments. It has poor responsibility and large error rate for low energy photon radiation of medical radiation environments. This study evaluated to optimal additional filtration for EPD using silicon PIN photodiode detector form 40 to 120 kVp range in medical radiation environments. From 40 to 80 kVp energy range, Al 0.2 mm and Sn 1.0 mm overlapped filtration showed good responsibility to dose rate and from 80 kVp to 120 kVp energy range, Al 0.2 mm and Sn 1.6 mm overlapped filtration showed good responsibility to dose rate.

A pilot study of half-value layer measurements using a semiconductor dosimeter for intraoral radiography

  • Shun Nouchi;Hidenori Yoshida;Yusaku Miki;Yasuhito Tezuka;Ruri Ogawa;Ichiro Ogura
    • Imaging Science in Dentistry
    • /
    • v.53 no.3
    • /
    • pp.217-220
    • /
    • 2023
  • Purpose: This pilot study was conducted to evaluate half-value layer (HVL) measurements obtained using a semiconductor dosimeter for intraoral radiography. Materials and Methods: This study included 8 aluminum plates, 4 of which were low-purity (less than 99.9%) and 4 high-purity (greater than 99.9%). Intraoral radiography was performed using an intraoral X-ray unit in accordance with the dental protocol at the authors' affiliated hospital: tube voltage, 60 kVp and 70 kVp; tube current, 7 mA; and exposure time, 0.10 s. The accuracy of HVL measurements for intraoral radiography was assessed using a semiconductor dosimeter. A simple regression analysis was performed to compare the aluminum plate thickness and HVL in relation to the tube voltage (60 kVp and 70 kVp) and aluminum purity (low and high). Results: For the low-purity aluminum plates, the HVL at 60 kVp (Y) and 70 kVp (Y) was significantly correlated with the thickness of the aluminum plate (X), with Y=1.708+0.415X (r=0.999, P<0.05) and Y=1.980+0.484X (r=0.999, P<0.05), respectively. Similarly, for the high-purity aluminum plates, the HVL at 60 kVp (Y) and 70 kVp (Y) was significantly correlated with the plate thickness(X), with Y=1.696+0.454X (r=0.999, P<0.05) and Y=1.968+0.515X (r=0.998, P<0.05), respectively. Conclusion: This pilot study examined the relationship between aluminum plate thickness and HVL measurements using a semiconductor dosimeter for intraoral radiography. Semiconductor dosimeters may prove useful in HVL measurement for purposes such as quality assurance in dental X-ray imaging.

Targeted Delivery of VP1 Antigen of Foot-and-mouth Disease Virus to M Cells Enhances the Antigen-specific Systemic and Mucosal Immune Response

  • Kim, Sae-Hae;Lee, Ha-Yan;Jang, Yong-Suk
    • IMMUNE NETWORK
    • /
    • v.13 no.4
    • /
    • pp.157-162
    • /
    • 2013
  • Application of vaccine materials through oral mucosal route confers great economical advantage in animal farming industry due to much less vaccination cost compared with that of injection-based vaccination. In particular, oral administration of recombinant protein antigen against foot-and- mouth disease virus (FMDV) is an ideal strategy because it is safe from FMDV transmission during vaccine production and can induce antigen-specific immune response in mucosal compartments, where FMDV infection has been initiated, which is hardly achievable through parenteral immunization. Given that effective delivery of vaccine materials into immune inductive sites is prerequisite for effective oral mucosal vaccination, M cell-targeting strategy is crucial in successful vaccination since M cells are main gateway for luminal antigen influx into mucosal lymphoid tissue. Here, we applied previously identified M cell-targeting ligand Co1 to VP1 of FMDV in order to test the possible oral mucosal vaccination against FMDV infection. M cell-targeting ligand Co1-conjugated VP1 interacted efficiently with M cells of Peyer's patch. In addition, oral administration of ligand-conjugated VP1 enhanced the induction of VP1-specific IgG and IgA responses in systemic and mucosal compartments, respectively, in comparison with those from oral administration of VP1 alone. In addition, the enhanced VP1-specific immune response was found to be due to antigen-specific Th2-type cytokine production. Collectively, it is suggested that the M cell-targeting strategy could be applied to develop efficient oral mucosal vaccine against FMDV infection.

Studies on the VP4 and VP7 Genes of Bovine Rotaviruses from Field Samples Using RT-PCR and RFLP Analysis (RT-PCR과 RFLP법을 이용한 국내 소 로타바이러스 VP4 및 VP7 유전자의 특성 규명)

  • Jeon, Seong-Jin;Chang, Chung-Ho;Chung, Chung-Won;Kim, Won-Yong;Kang, Shien-Young
    • The Journal of Korean Society of Virology
    • /
    • v.28 no.2
    • /
    • pp.165-174
    • /
    • 1998
  • Characterizations of the VP4 (P type) and VP7 (G type) genes of Korean isolates of bovine rotavirus were performed using RT-PCR/RFLP and nucleotide sequencing analysis. After RT-PCR amplification of partial length (1094bp) of the VP4 and full length (1062bp) of the VP7 genes, amplified PCR products were digested with restriction endonucleases and digestion patterns were compared with those of reference rotaviruses. With the VP4 genes, four RFLP (A-D) profiles were observed; three (A, Band C) were the same as those of bovine rotavirus NCDV (P[1]), IND (P[5]) and B223 (P[11]), respectively. Profile D was the same as that of porcine rotavirus OSU (P[7]). With the VP7 genes, five RFLP profiles (I-V) were observed; three of them (I, II and III) were the same as those of bovine rotavirus NCDV (G6), Cody 1-801 (G8), and B223 (G10), respectively. Profile IV and V were atypical to those of reference bovine rotaviruses used in this study. These two profiles were identified as G6 and G5, respectively, after analyzing and comparing the nucleotide sequences. The G typing analysis revealed that 61.9% (26/42) were G6, which included G6 subtype; 28.6% (12/42) were G5; 7.1% (3/42) were G10; 2.4% (1/42) were G8. The P typing analysis revealed that 54.8% (23/42) were P[5]; 28.6% (12/42) were P[7]; 11.8% (5/42) were [11]; 4.8% (2/42) were P[1]. Our results showed that G6/P[5] were the most prevalent rotaviruses in diarrheic calves in Korea. Also, this is the first report that G5/P[7] rotaviruses were identified from cattle with diarrhea.

  • PDF

Selective Permeate Transport Characteristics of Iodine ion at Cell Membrane Model of Thyroid which Irradiated by High Energy X-Ray (고에너지 엑스선을 조사한 갑상선의 세포막모델에서 요오드이온의 선택적 투과성 전달 특성)

  • Ko, In-Ho;Yeo, Jin-Dong
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.229-238
    • /
    • 2021
  • The selective permeate transport characteristics of iodine ion at follicle cell membrane model in thyroid which irradiated by high energy x-ray(linac 6 MV) was investigated. The follicle cell membrane model used in this experiment was a polysulfonated copolymerized membrane of poly(4-vinylpyridine-co-acrylonitrile:VP-AN). The difference of membrane thickness [2 mole AN%(w/w)], fixed carrier concentration[VP-AN%(w/w)], OH- concentration were occurred at difference of I- concentration and quantity of thyroid hormone, respectively. The tensile strength in fixed carrier concentration[VP-AN% (w/w): 0-62 %] of irradiated membrane was found to be decreased about 1.2-1.8 times than non-irradiated membrane. The I- selective permeate initial flux with increase of membrane thickness [2mole AN%(w/w)], fixed carrier concentration[VP-AN%(w/ w)], OH- concentration in irradiated membrane were found to be decreased about 2.1-4.5 times, about 2.2-2.5 times, about 2.1-2.67 times than non-irradiated membrane, respectively. As a result, the quantity of thyroid hormone was decreased at irradiated membrane than non-irradiated membrane. The decrease of thyroid hormone was occurred at hypothyroidism and hyperthyroidism, thyroid cancer, and so on. As the thyroid hormone in cell membrane model were abnormal, cell damages were appeared at cell.

A Study on the Preparation of Carboxylated Polysulfone/MeVpI-DVB Membranes and Its Characteristics (Carboxylated Polysulfon/MeVpl-DVB 막의 제조와 특성에 관한 연구)

  • 김관식;전경용;조영일
    • Membrane Journal
    • /
    • v.5 no.1
    • /
    • pp.26-34
    • /
    • 1995
  • In this study, polysulfone was carboxylated(CPSf), as a method of introducing carboxyl group to polymer main chain using direct lithiation reaction. Then, poly(1-alkyl-4-vinylpyridinium iodide-co-divinylbenzene) (MeVpI-DVB) containing pyridinium cation which has an anion selectivity as a fixed carrier was synthesized. And polymer membranes were prepared by mixing CPSf and MeVpI-DVB. Characteristics and permeation of membranes were investigated. As a result of synthesizing CPSf/MeVpI-DVB, blend was formed, not new copolymer. As the content of CPSf amount increasing, thermal stability of membranes was increasing. Ion exchange capacity was 1.0~1.8(meq/g dry mem.) and water content was 0.16~0.26(g $H_2{O}$)/g dry mem.) and fixed ion concentration was 6.4~7.3(meq/g $H_2{O}$) in synthetic membranes. The $Cl^-$ flux showed an increase due to the increase of CPSf content.

  • PDF

Cell Loss Recovery Algorithm for ATM Networks (ATM 망에서의 셀 손실 복구 기법에 관한 연구)

  • Shim, Yun-Sup;Chun, Sang-Hun;Kwak, Kyung-Sup
    • Journal of IKEEE
    • /
    • v.3 no.1 s.4
    • /
    • pp.22-28
    • /
    • 1999
  • The existing CREG-VP, a technique to compensate the successive cell losses caused by traffic congestion using the FEC method on the Vp, has the merits of the short average encoding decoding time and the compatibility with the ATM standard cell format, but it has the restriction in the number of regenerable cells. In this thesis, we propose a scheme to efficiently regenerate the cell losses even in the burst traffic property by the expansion of the CREG-VP. The proposed scheme improves the detection capability of the lost cells by changing the CRP and the regeneration performance of the successive cells by using the interleaved parity cell. The simulation result shows that the proposed method produces much improvements compared with the existing ones in the cell loss rate reduction factor.

  • PDF

VP7 Genotypes of Group A Rotavirus Isolated from Infants and Toddlers with Rotavirus Gastroenteritis in Jeju (제주지역 로타바이러스 위장관염 환아로부터 분리한 A군 로타바이러스의 VP7 Genotypes에 대한 연구)

  • Kang, Ki Soo;Shin, Kyung-Sue;Cui, Xiu Ji;Kim, Wonyong
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.9 no.2
    • /
    • pp.147-152
    • /
    • 2006
  • Purpose: Efficacy of the new rotavirus vaccines ($Rotarix^{(R)}$, $RotaTeq^{(R)}$) recently developed can be affected by the rotavirus genotypes prevalent in communities. We performed this study to identify the recent distribution of rotavirus genotypes prevalent in Jeju. Methods: Genotyping of human rotaviruses was performed using 81 samples collected from 154 inpatients and outpatients with rotavirus gastroenteritis at Cheju National University Hospital between July 2005 and June 2006. All six (1, 2, 3, 4, 8, 9) G serotypes were identified by amplification of segments of the gene for VP7 using the reverse transcription-polymerase reaction (RT-PCR). Results: The results of RT-PCR for 81 samples were all positive. G typing of the VP7 protein showed that G1 was the most dominant circulating genotype (65.5%) followed by G2 (14.8%), G3 (13.6%), G8 (1.2%), G9 (1.2%), G4 (0%), and a combination of G1/G3 (3.7%). Conclusion: This distribution of rotavirus VP7 genotypes in Jeju is different from that in other domestic areas; the most dominant circulating genotype was G1.

  • PDF

Syntactic Ambiguities and Their Resolution in Prosody between Sendai dialect of Japanese and Ankara dialect of Turkish (일본 센다이 방언과 터키 앙카라 방언의 운율에 나타나는 통사적 애매성 해소에 관한 연구)

  • Choi, Young-Sook
    • Speech Sciences
    • /
    • v.10 no.3
    • /
    • pp.175-185
    • /
    • 2003
  • Japanese and Turkish are syntactically similar to each other, and there are syntactic structures that become ambiguous in terms of NP's and VP's modified by adjectives and adverbs, respectively. The prosody can play a crucial role in differentiating ambiguous sentences to correctly reflect their intended syntactic structures. In what way do the speakers of Sendai dialect of Japanese and Turkish use prosodic elements to differentiate syntactic ambiguities? Acoustic measurements were made of utterances of ambiguous sentences in Japanese and Turkish to observe prosodic strategies for disambiguation. Materials were sentences of the type ADV-VP1-NP-VP2, ADV-NP1-NP2-VP2, where the ambiguity lies in locative adverbial modification, ADV modifying either VP1 or VP2. For this construction the Japanese and Turkish creates the same ambiguities. In this paper, I look at duration, F0, and pause as observed in their speech and see how each language uses three prosodic elements in disambiguation. The results show that both speakers of Sendai dialect in Japan and those of Ankara dialect in Turky use lengthening of the syllable and/or pause before the boundary.

  • PDF

Barium Compounds through Monte Carlo Simulations Compare the Performance of Medical Radiation Shielding Analysis (몬테카를로 시뮬레이션을 통한 바륨화합물의 의료방사선 차폐능 비교 분석)

  • Kim, Seonchil;Kim, Kyotae;Park, Jikoon
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.6
    • /
    • pp.403-408
    • /
    • 2013
  • This study made a tentative estimation of the shielding rate of barium compound by thickness through monte carlo simulation to apply medical radiation shielding products that can replace existing lead. Barium sulfate($BaSO_4$) was used for the shielding material, and thickness of the shielding material specimen was simulated from 0.1 mm to 5 mm by applying $15{\times}15cm^2$ of specimen area, $4.5g/cm^3$ of density of barium sulfate, and $11.34g/cm^3$ density of lead. Entered source was simulated with 10kVp Step in consecutive X-ray energy spectrum(40 kVp ~ 120 kVp). Absorption probability in 40 kVp ~ 60 kVp showed same shielding rate with lead in 3 mm ~ 5 mm of thickness, but it was identified that under 2 mm, the shielding rate was a bit lower than the existing lead shielding material. Also, the shielding rate in 70 kVp ~ 120 kVp energy band showed similar performance as the existing lead shielding material, but it was tentatively estimated as fairly low shielding rate below 0.5 mm. This study estimated the shielding rate of barium compound as the thickness function of x-ray energy band for medical radiation through monte carlo simulation, and made comparative analysis with existing lead. Also, this study intended to verify application validity of the x-ray shielding material for medical radiation of pure barium sulfate. As a result, it was estimated that the shielding effect was 95% higher than the existing lead 1.5 mm in at least 2 mm thickness of barium compound in medical radiation energy band 70 kVp ~ 120 kVp, and this result is considered valid to be provided as a base data in weight lightening production of radiation shielding product for medical radiation.