• Title/Summary/Keyword: VOCs analysis

Search Result 326, Processing Time 0.028 seconds

A Study on the VOCs Emission Characteristics in Leather Industries (피혁산업장의 휘발성유기화합물(VOCs) 배출 특성에 관한 연구)

  • Kim, Sun-Tae;Choi, Il-Hwan;Lee, Kyu-Sung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.3
    • /
    • pp.332-343
    • /
    • 2007
  • The concentrations of major volatile organic compounds (VOCs) were measured using a passive sampler in the leather industries, Shihwa and Banwol industrial complex. The leather industries were classified into four groups in raw materials and main product. The concentrations of total VOCs measured in process for ${\ulcorner}$ manufacture of reconstituted leather and special treated leather${\lrcorner}$was highest. The main VOCs measured in the leather industries was found to be toluene with a average concentration of 1,200 ppb. The major group selected in the leather industries was divided into three groups by the fingerprint analysis and the principal component analysis. The major VOCs in the groups classified by fingerprint analysis were found to be dependent on the characteristics of raw materials and main products.

Analysis of VOCs emitted from the Annals of the Joseon Dynasty by Dynamic Chamber System (Chamber System을 이용한 조선왕조실록의 미세유출가스 분석)

  • Kang, Yeong-Seok;Seo, Jin-Ho
    • 보존과학연구
    • /
    • s.31
    • /
    • pp.9-16
    • /
    • 2010
  • The Annals of the Joseon Dynasty is one of the World Heritage which should be conserved well. However, some of wax treated volume of the Annals of the Joseon Dynasty have damaged seriously. Currently a variety of efforts to conserve and restore the injured volumes are continued and many studies about the aging mechanism of the wax treated volume have being progressed. The analysis of VOCs (Volatile Organic Compounds) emitted from paper cultural heritage is one of the methods to understand the degradation pathway of paper cultural heritage. The analysis of VOCs emitted from paper cultural heritage has been mainly conducted by SPME (Solid Phase Microextraction) method. SPME is potable and simple method but it is difficult to collect all VOCs emitted from a book such as the Annals of Joseon Dynasty. The dynamic chamber system has generally used to do analysis of VOCs emitted from the building materials, furniture and electric appliances. The chamber system is possible to do quantitative and qualitative analysis by a continuous $N_2$ gas flow and the proper chamber which is able to gather all VOCs emitted from the Annals of the Joseon Dynasty. In this study, the most material among detected VOCs was Naphthalene. Naphthalene has used to prevent organic cultural heritage from being damaged by various microbes for a long time. Apart from Naphthalene, main VOCs were Acetic acid, 2-Chloroethanol, 2-Bromoethanol, Furfural, 1-Methylnaphthalene, Azulene, and 2,4-Dioctylphenol. Of these VOCs, Furfural especially was known for a marker which represents a different emission rate according to the aging level.

  • PDF

A Study on the Volatile Organic Compounds Analysis Method for Visible Light-Responsive Photocatalyst Treated Vehicle Interior Materials (가시광촉매가 처리된 자동차 내장재의 VOC 분석방법에 대한 연구)

  • Choi, Sei Young
    • Elastomers and Composites
    • /
    • v.48 no.3
    • /
    • pp.221-224
    • /
    • 2013
  • In this study, VOC analysis method of vehicle interior materials and parts treated to visible-light responsive photocatalyst was tested by sample bag filled with air instead of nitrogen. As a result, when analyzed VOC of vehicle interior materials and parts, sample bag filled with the nitrogen was not confirmed of effect reducing VOCs and formaldehyde. However, VOCs and formaldehyde of sample bag that was filled with air instead of nitrogen, decreased significantly. Reaction effect for visible light-responsive photocatalyst was confirmed that sample bag of vehicle interior materials and parts should be filled with air instead of nitrogen.

The Development of VOC Measurement System Uging PCA & ANN (PCA와 ANN을 이용한 VOC 측정기기 개발)

  • Lee Jang-Hoon;Kwon Hyuk-Ku;Park Seung Ho;Kim Dong-Jin;Hong Chol-Ho
    • Environmental Analysis Health and Toxicology
    • /
    • v.19 no.2
    • /
    • pp.161-167
    • /
    • 2004
  • Air quality monitoring is a primary activity for industrial and social environment. The government identifies the pollutants that each industry must monitor. Especially, the VOCs (Volatile Organic Compounds), which are very harmful to human body and environment atmosphere, should be controlled under the government policy. However, the VOCs, which have not been confirmed in emission sources are very difficult to monitor. It is needed to develop the monitoring system that allow the continuous and in situ measurement of VOCs mixture in different environmental matrices. Gas chromatography and mass spectrometry are the most prevalent current techniques among those available for the analysis of VOCs. But, they need a large size analytical instrument, which costs a great deal for purchase and operation. In addition, it has some limitations for realtime environmental monitoring such as location problems and slow processing time. Recently, several companies have commercialized a portable VOCs measurement systems, which cannot classify various kinds of VOCs but total quantities. We have developed a VOCs measurement system, which recognizes various kinds and quantities of VOCs, such as benzene, toluene, and xylene (BTX). Also, it can be used as a stand- alone type and/or fixed type in the vehicle with rack for real -time environmental monitoring.

Comparison of VOCs Concentration Characteristic According to Measurement Methods in Exhibition Hall (휘발성유기화합물(VOCs)의 측정방법에 따른 유물 전시관 내 농도 분포 특성 비교)

  • Lim, BoA;Lee, Sun Myung
    • 보존과학연구
    • /
    • s.35
    • /
    • pp.25-44
    • /
    • 2014
  • In this study, measured annual year and seasonal concentrations of VOCs by Active type and Passive type using the measurement and analysis method in the exhibition hall and outdoor. It was compared with the correlation between the methods according the comparison of methods to measured concentrations. As a results, the annual average concentrations of TVOC in exhibition room($906.5{\mu}g/m^3$) was greater than for most of the study period, more than 1.8 times the standard in the Ministry of Environment. ${\Sigma}VOCs$ concentration of exhibition room by Active type was higher than Passive type. Some VOCs was decreased with the lapse of time a temporary increase tendencies was. The annual average I/O ratio of TVOC was 9.0, ${\Sigma}VOCs$ was confirmed to occur in a large amount inside the exhibition hall ${\Sigma}VOCs$ was studied to 34.0. Correlation coefficient of ${\Sigma}VOCs$ was 0.367. Toluene was 0.567 that the survey was the largest analysis to the relationship between the two methods.

  • PDF

Study on Analysis of Volatile Organic Compounds(VOCs) in Water(II) (수중 휘발성 유기물질의 분석에 관한 연구 (I) - Purge & Trap을 이용한 휘발성 유기물질 분석기법의 고찰 -)

  • 전옥경;서병태;이정자
    • Journal of Environmental Health Sciences
    • /
    • v.20 no.4
    • /
    • pp.53-59
    • /
    • 1994
  • Since trihalomethanes (THMs) and other volatile organic compounds (VOCs) were detected and measured in drinking water supplies in 1974, because of the frequent occurrence of these compounds and the potential health hazard they pose, several methods for detecting VOCs have been developed. The most widely accepted method for the analysis of THMs and other VOCs is a purgeand-trap method. In the analysis of VOCs by purge-and-trap,there are several factors which may give rise to errors. Some of the factors to be considered are purge time, carryover effect, cryofocusing temperature, and trap desorption temperature. In this study,many aspects of purge-and-trap were investigated. Understanding the sources of error makes it possible to adapt the analysis parameters to compensate for such effects.

  • PDF

The Analysis of VOCs by GC/MS with Whole Column Coldtrapping on a Fused Silica Capillary Column in Indoor Environment

  • Dai, Shugui;Zhang, Lin;Bai, Zhipeng
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.829-834
    • /
    • 1995
  • Whole column coldtrapping(WCC) on a fused silica capillary (FSCC)combined with GC/MS analysis was evaluated for use in the investigation of volatile organic compounds(VOCs) in indoor air. Research had indicated that a temperature of $-80^{\circ}C$ is optimal for WCC. Samples were analyzed on a $50m{\times}0.2mm$ cross-linked 5% phenylmethylsilicone fused silica column. Liquid nitrogen was used as the coolant for the peak resolution significantly. The analysis can be performed quickly and conveniently. More than 112 of VOCs were determined in the samples from three typical indoor environment including: (1) a room which had just been decorated involving building materials and paints; (2)a kitchen used for Chinese cooking, and (3) a room had tobacco smoke. The method is could be readily applied to rapid sample screening for VOCs contamination surveys or initial investigations with its valid and simple sampling and analytical technique.

  • PDF

Estimation and Analysis of VOCs Emissions from Painting and Printing Facilities in Industrial Complexes of Gwangju (광주지역 산업단지 도장·인쇄시설의 휘발성유기화합물 배출 특성 평가)

  • Kim, Seung-Ho;Seo, Dong-Ju;Kim, Ha-Ram;Park, Jin-Hwan;Lee, Ki-Won;Bae, Seok-Jin;Song, Hyeong-Myeong
    • Journal of Environmental Science International
    • /
    • v.29 no.5
    • /
    • pp.479-494
    • /
    • 2020
  • This study analyses the characteristics of volatile organic compounds (VOCs) emissions from the painting and printing facilities, as well as ambient VOCs at industrial complexes in Gwangju. The major components of VOCs emissions from painting facilities were toluene, acetone, 2-butanone, ethyl acetate, ethyl benzene, o-xylene and m,p-xylene. The printing facilities mostly emitted ethyl acetate, 2-butanone, acetone and toluene. Aromatics (49.9%) and oxygenated VOCs (43.6%) were dominant in painting facilities, while oxygenated VOCs (92.7%) were the largest group in printing facilities. The total hydrocarbon concentration (THC) in printing facilities was approximately six times higher than in the painting facilities. The painting and printing facilities use many solvents. Their THC concentrations differed considerably depending on the type of prevention facilities. To reduce THC, it is necessary to improve the prevention facilities and operating conditions. The dominant species of ambient VOCs in industrial complexes were investigated with toluene, ethyl acetate, 2-butanone, ethyl benzene, m,p-xylene, butyl acetate, o-xylene, hexane and acetone. Factor analysis of ambient VOCs showed that the main sources of the VOCs were organic solvents used in painting, coating, and printing, as well as automobile emissions.

Quality Control(QC) Analysis of Ambient VOCs in Canisters Using GC/MSD Method (Canister와 GC/MSD를 이용한 대기 중 VOCs 분석시스템의 정도관리(QC))

  • Jeon, Jun-Min;Hur, Dang;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.6
    • /
    • pp.527-538
    • /
    • 2002
  • In this study, the performance of sampling and of analytical methodology was examined against a number of selected volatile organic compounds (VOCs) in the ambient air. The canister-based sampling method for VOCs has been a viable and widely used approach that is based on research and evaluation performed over the past several years. VOCs were determined using canisters by GCMSD analysis. A total of target analyses in this study included approximately 30 VOCs designated in TO-l4A categories including BTEX. The methodology for QC(quality control) was intensively investigated with a wide range of performance criteria such as; (1) cleanliness of canisters, (2) reproducibility of diluter, (3) instrumental detection limits of preconcentrator and GCMSD, and (4) precision and accuracy of GCMSD. For most of the compounds tested, precision was less than $\pm$5%, IDL was 0.2 ppbv, accuracy was $\pm$5%, respectively. This study demonstrated that the combination of canister sampling and GC/MSD analysis could be reliably applied to the measurements of BTEX in ppbv levels that are typically observed in/outdoor air environment.

Influence of Organic Matter and Temperature on the Sorption of Volatile Organic Compounds on Soil (토양 흡착에 대한 유기탄소와 온도의 영향)

  • 김희경
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1998.11a
    • /
    • pp.57-59
    • /
    • 1998
  • The headspace method has been acknowledged as a cost-effective and convenient method to analyze volatile organic compounds(VOCs) in soil. The headspace analysis is based on equilibrium partitioning of VOCs among water, air and soil in a closed system. However, the headspace method cannot be applied to soils where most of the VOCs remain sorbed even at high temperature. In this study, it was investigated how the sorption characteristics of VOCs varied with soil with different organic carbon contents and temperature. This study showed that all the VOCs were volatilized, not sorved, only in the soil with 5% organic carbon at 45$^{\circ}C$ or higher. Some fraction of VOCs remained in soil with 8% organic carbon at $65^{\circ}C$ of higher. Most of the VOCs remained sorbed in soil with 12% organic content even at 95$^{\circ}C$. This result suggested that the headspace method can be applied only to soils with little organic carbon content (less than 5%). In this case, 45$^{\circ}C$ seems to be high enough to volatilize all the VOCs from soil. Large particles still showed a significant sorption capacity for VOCs from soil. Large Particles still showed a significant sorption capacity for VOCs despite of their low level of organic carbon content. It was also shown that the organic carbon sorption coefficients (Koc) of VOCs varied with soils with different organic carbon content. This suggests that not only the organic matter content of soil but also the property of the organic matter in soil influence the sorption of VOCs to soil.

  • PDF