• Title/Summary/Keyword: VOCs(Volatile Organic Compounds)

Search Result 684, Processing Time 0.024 seconds

Removal Rates of VOCs(Volatile Organic Compounds) for Treatment Condition using DAF(Dissolved Air Flotation) in Water Treatment (DAF(Dissolved Air Flotation)를 이용한 정수처리에서 처리조건에 따른 VOCs(Volatile Organic Compounds)의 처리효율에 대한 연구)

  • Kim, Mi-Jeong;Jun, Se-Jin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.3
    • /
    • pp.91-100
    • /
    • 1999
  • Treatment conditions of DAF(Dissolved Air Flotation) and removal rates of VOCs(Volatile Organic Compounds) in mixed water of H raw water and VOCs were investigated. The used VOCs were benzene, toluene, ethylbenzene, and xylene in aromatic compounds and iso propyl mereaptan, n-butyl mereaptan, dimethyl disulfide, and iso butyl mercaptan in odors. The related parameters include water type, treatment method, clay concentration, pH condition, flocculation time, flotation time, per-cent recycle, water temperature, pressure. The removal rates of VOCs were different on treatment process and water condition. Treatment time was longer, removal rates of VOCs was higher. Water temperature was more important than pressure in DAF parameters. Molecular weight was related with removal rate in several kinds of VOCs were decraesed by competition of each component in II raw water. When algac blooming D water was treated by DAF, TCOD(Total chemical Oxygen Demand) and chorophyll a was removed over 96%.

  • PDF

A Study on Purge Efficiency in Purge and Trap Analysis of VOCs in Water

  • Lee, Gang Jin;Pyo, Hui Su;Park, Song Ja;Yu, Eun A;Lee, Dae Un
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.2
    • /
    • pp.171-178
    • /
    • 2001
  • A Purge and Trap Concentrator has been used to analyze various volatile organic compounds in water, operating several parameters affecting the extraction efficiencies of these compounds. The object of the present study was to observe the purge efficiencies of 40 volatile organic compounds (VOCs) in water, according to the change of parameters (purge time, dry purge time, sample temperature), and to determine the optimum condition of analysis of VOCs. The Purge and Trap Concentrator was interfaced with a narrow capillary connected to a gas chromatography mass spectrometer. At this condition, the detection limits of VOCs were in the range of 0.1-0.5 ㎍/L.

Characterization of Volatile Organic Compounds associated with Environmental Tobacco Smoke

  • Baek, Sung-Ok;Roger A. Jenkins
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.E
    • /
    • pp.41-58
    • /
    • 1998
  • In this study, a wide range of volatile organic constituents of environmental tobacco smoke (ETS) were determined using an environmental chamber, where ETS is the sole source of target compounds. ETS was generated in an environmental chamber by a number of different cigarettes, including the Kentucky reference cigarette and eight different commercial brands. More than 30 compounds were measured simultaneously for a total of twelve experimental runs. The target compounds are classified into three major classes, i.e. vapor phase ETS markers including 3-ethnylpyridine (3-EP) and nicotine, carbonyl compounds including formaldehyde, and volatile organic compounds (VOCs). The results from the chamber study were used to generate characterized ratios of selected VOCs to 3-EP, a vapor phase ETS marker. Emission factors for VOCs associated with ETS were also estimated. The characteristic ratios appeared to be generally in good agreement with published data obtained by environmental chamber studies similar to this study. This implies that the ratios may be useful for identifying and quantifying the impact of ETS as a source of target compounds in 'real world' indoor environments, which is affected by a complex mixture of multi-sources. The environmental chamber method described here provides a direct and reliable method to compare the ETS generated by different cigarettes. The method can also be applied to the simultaneous determination of many different ETS components.

  • PDF

Evaluation of VOCs in Kumi industrial Complex (공단지역에서의 휘발성유기화합물의 농도 평가)

  • 배상호;최우건;박덕신;정우성;김태오
    • Proceedings of the KSR Conference
    • /
    • 2002.10b
    • /
    • pp.943-947
    • /
    • 2002
  • Volatile Organic Compounds(VOCs) contribute to the formation of ozone and PAN which are injurious to health through complex photochemical reactions. Growing consumption of fossil fuels results in significant emission of VOCs and other air pollutants into the atmosphere. This study was carried out to evaluate of Volatile Organic Compounds(VOCs) concentrations in Kumi industrial complex. Ambient air sampling was determined at five sites from August to September in 2002. The Volatile Organic Compounds samples were collected using the silicocan canisters, and were determined by GC/MS which connected preconcentrator system. The Kumi industrial complex of VOCs concentrations were generally similar with Yeochun's but some of VOCs concentrations of Kumi were higher than Yeochun industrial complex's. Also the industrial area was higher than downtown and residential district.

  • PDF

Emission Characteristics of Volatile Organic Compounds (VOCs) from a Carpet (카페트에서 방출되는 VOCs의 방출특성)

  • 신동민;김창녕;김동술
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.1
    • /
    • pp.40-49
    • /
    • 2003
  • This study has been conducted to identify and quantify the emissions of Volatile Organic Compounds (VOCs) from a new carpet. The carpet sample consists of polypropylene cushion and latex backing. The VOCs have been sampled on sorbent tubes and analyzed by thermal desorption unit and GC/MSD. For over 240 hours, concentration of VOCs has been measured in a small chamber made of stainless steel. With the measured data, emission factor and mass balance have been considered. The experiments have been conducted in accordance with ASTM D5116-97. The carpet has emitted a variety of VOCs, but in this study, 7 VOCs compounds have been considered: chlorobenzene, ethylbenzene, styrene, isopropylbenzene, bromobenzene, 2-chlorotoluene, and 1,2,3-trimethylbenzene. The results show that the concentrations of VOCs and the emission factors have exponentially decayed from relatively high level to low level with time. The gradients of the concentration of VOCs and emission factors are different for various components. It is found that styrene, 2-chlorotoluene are emitted more than others with higher concentrations.

Emissions of Volatile Organic Compounds from a Swine Shed

  • Osaka, Nao;Miyazaki, Akane;Tanaka, Nobuyuki
    • Asian Journal of Atmospheric Environment
    • /
    • v.12 no.2
    • /
    • pp.178-191
    • /
    • 2018
  • The concentrations and chemical compositions of volatile organic compounds (VOCs), including volatile fatty acids, phenols, indoles, aldehydes, and ketones, which are the main organic compounds generated by swine, were investigated in July and October 2016 and January 2017. In addition, the emission rates and annual emissions of these components from the swine shed were estimated. The concentrations of VOCs in the swine shed averaged $511.3{\mu}g\;m^{-3}$ in summer, $315.5{\mu}g\;m^{-3}$ in fall and $218.6{\mu}g\;m^{-3}$ in winter. Acetone, acetic acid, propionic acid, and butyric acid were the predominant components of the VOCs, accounting for 80-88% of the total VOCs. The hourly variations of VOC concentrations in the swine shed in fall and winter suggest that the VOC concentrations were related to the ventilation rate of the swine shed, the activity of the swine, and the temperature in the swine shed. Accordingly, the emission rates of VOCs from the swine shed were $1-2{\times}10^3{\mu}g(h\;kg-swine)^{-1}$.

A study on measurement of VOCs in newly house (신축 공동주택의 VOCs 실태조사)

  • 유복희;윤정숙
    • Journal of the Korean housing association
    • /
    • v.13 no.5
    • /
    • pp.71-76
    • /
    • 2002
  • Recently, much attention has been paid to the problem such as sick building syndrome, which caused by the air pollutant indoor. In addition, Volatile Organic Compounds(VOCs) has been paid attention to as one of the main reason that causes air pollutant indoor, and the exposure of VOCs indoor is recognizes as an important factor which have an effect on the health of resident. In this study, measuring of VOCs in newly houses, and the results are as follows; 1)TVOC(Total Volatile Organic Compounds) indoor is detected high concentration(11314$\mu\textrm{g}$/㎤). 2)There are detected acetaldehyde, methylenechloride, benzene, trichloroethylene and styrene that have to take precaution against human carcinogenicity

Variations of Concentration Levels of Volatile Organic Compounds in the Indoor Air due to Floor Waxing (왁스 청소에 기인한 실내 공기 중 휘발성 유기화합물의 농도변화)

  • 김만구;박춘옥;권영진;이용근;이대운
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.13 no.3
    • /
    • pp.221-229
    • /
    • 1997
  • Wax is a protectant for floors that is used widely in Korea and is considered an emission source of volatile organic compounds (VOCs) in the indoor environment. This study examined the concentration change of indoor VOCs due to waxing and also due to wiping the floor with an oiled dustcloth. VOCs were identified using a cryogenic concentration/thermal desorption system with capillary GC that utilized a liquid nitrogen cryostat and induction heating. The major components emitted from the waxing were nonane, decane, undecane, $C_2$-benzene, and $C_3$-benzene. The concentrations of nonane were 1,276 $\mu\textrm{g}$/㎥ an hour after wax applications, 832 $\mu\textrm{g}$/㎥ after 3 days, and less than 10$\mu\textrm{g}$/㎥) after 15 days. Another emission source of VOCs in indoor was the oiled dustcloth used for cleaning the floor. The oiled dustcloth gave VOCs concentrations three times higher than the normal undusted floor.

  • PDF

The Characteristic of Volatile Organic Compounds(VOCs) Emission from the Type of Indoor Building Materials as the Temperature and Humidity (온.습도에 따른 건축 내장재별 휘발성유기화합물의 방출특성)

  • Seo, Byeong-Ryang;Kim, Shin-Do;Park, Seong-Kyu
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.4 s.91
    • /
    • pp.292-303
    • /
    • 2006
  • The Volatile Organic Compounds(VOCs) are emitted from various sources and have lots of different form. Recently human are spending the many times at indoor area and indoor air pollution is issued the important social problem. The emission sources of indoor air pollutants are very various, also indoor building materials are composed of very complex chemical compounds, these indoor building materials discharge very much VOCs and other hazardous compounds. In this study, we performed the small chamber test to investigate the VOCs emission concentration and characteristics involving five kinds of the indoor building materials(furniture material, wooden floor, wall paper, paint and tile) under different conditions of four temperature and relative humidity as account of the air flow rate(AFR), air exchange rate(AER), loading factor and air velocity respectively. As the result, It was showed that building materials are emitted the highest VOCs concentration at the beginning of experiment and furniture material is emitted the highest VOCs concentration. Most of the materials were affected by temperature, but paint and tile material were affected by humidity.

Oxidation characterization of VOCs(volatile organic compounds) over pt and ir supported catalysts (Pt와 Ir을 담지한 촉매에 의한 휘발성유기화합물들의 산화특성)

  • Kim, Moon-Chan;Yoo, Myong-Suk
    • Analytical Science and Technology
    • /
    • v.18 no.2
    • /
    • pp.130-138
    • /
    • 2005
  • Volatile organic compounds (VOCs) have been recognized as major contributor to air pollution. Catalytic oxidation in VOCs can give high efficiency at low temperature. In this study, monometallic Pt, Ir and bimetallic Pt-Ir were supported to $TiO_2$. Xylene, toluene and methyl ethyl ketone (MEK) were used as reactants. The monometallic or bimetallic catalysts were prepared by the excess wetness impregnation method and characterized by XRD, XPS and TEM analysis. Result reveal that Pt catalyst has higher conversion than Ir catalyst and Pt-Ir bimetallic catalysts. The existence of multipoint actives in, Pt-Ir bimetallic catalysts gives improved performance for the Pt metalstate. Bimetallic catalysts have higher conversion for VOCs than monometallic ones. The addition, VOCs oxidation follows first order kinetics. The addition of small amount of Ir to Pt promotes oxidation conversion of VOCs.