An Study on Estimating Cargo Handling Equipment Emission in the Port of Incheon (인천항 하역장비 대기오염물질 배출량 산정 연구)

  • Zhao, Ting-Ting;Pham, Thai-Hoang;Lee, Hyang-Sook
    • Journal of Korea Port Economic Association
    • /
    • v.36 no.3
    • /
    • pp.21-38
    • /
    • 2020
  • Currently, in-port emissions are a serious problem in port cities. However, emissions, especially non-greenhouse gases, from the operation of cargo handling equipment (CHE) have received significant attention from scientific circles. This study estimates the amount of emissions from on-land port diesel-powered CHE in the Port of Incheon. With real-time activity data provided by handling equipment operating companies, this research applies an activity-based approach to capture an up-to-date and reliable diesel-powered CHE emissions inventory during 2017. As a result, 105.6 tons of carbon monoxide (CO), 243.2 tons of nitrogen oxide (NOx), 0.005 tons of sulfur oxide (Sox), 22.8 tons of particulate matter (PM), 26.0 tons of volatile organic compounds (VOCs), and 0.2 tons of ammonia (NH3) were released from the landside CHE operation. CO and NOx emissions are the two primary air pollutants from the CHE operation in the Port of Incheon, contributing 87.71% of the total amount of emissions. Cranes, forklifts, tractors, and loaders are the four major sources of pollution in the Port of Incheon, contributing 84.79% of the total in-port CHE emissions. Backward diesel-powered machines equipped in these CHE are identified as a key cause of pollution. Therefore, this estimation emphasizes the significant contribution of diesel CHE to port air pollution and suggests the following green policies should be applied: (1) replacement of old diesel powered CHE by new liquefied natural gas and electric equipment; (2) the use of NOx reduction after-treatment technologies, such as selective catalytic reduction in local ports. In addition, a systematic official national emission inventory preparation method and consecutive annual in-port CHE emission inventories are recommended to compare and evaluate the effectiveness of green policies conducted in the future.

Characterization of Volatile Organic Compounds Emission from Interior Materials of Railway Passenger Cabin (철도차량용 내장재의 휘발성유기화합물 방출특성 분석)

  • Cho, Young-Min;Park, Duck-Shin;Kwon, Soon-Bark;Park, Eun-Young
    • Journal of the Korean Society for Railway
    • /
    • v.11 no.2
    • /
    • pp.182-187
    • /
    • 2008
  • The environmental significance of indoor air quality is gaining more attention. Especially, the contamination of indoor air by volatile organic chemicals (VOCs) has become a serious environmental concern. We investigated the VOCs emissions from some interior materials used in the conventional railway passenger cabin. The seat cover and the flooring of cabins were used as testing materials, and they were put in a clean environmental chamber. The temperature and relative humidity was kept at $25{\pm}1^{\circ}C$ and $50{\pm}5%$, respectively. It was found that these interior materials emitted significant amount of VOCs under constantly ventilated condition. The flooring emitted more halogenated VOCs than the seat cover, because it is made of PVC, which contains many chlorine atoms. However, the emission gradually decreased over time. Because the VOCs emission from interior materials may threaten the health of passengers in the cabin, interior materials emitting less VOCs should be used.

Characteristics of Volatile Organic Compounds Emitted from Wood-based Panels (목질제품에서 방출되는 휘발성 유기화합물 특성 연구)

  • Park, Hyun-Ju;Son, Youn-Suk;Lim, Bo-A;Kim, Jo-Chun;Park, Sang-Bum
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.6
    • /
    • pp.616-623
    • /
    • 2010
  • Recently, interests in indoor air quality (IAQ) have been increased; however, a number of researchers have mainly focused on anthropogenic volatile organic compounds (AVOC) emitted from building materials. Therefore, the properties of natural VOC (NVOC) and anthropogenic VOC (AVOC) emitted from wood-based panels was investigated in this work. VOCs emitted from these panels were sampled through Tenax TA/Cabotrap and analyzed by GC-MS and GC-FID. Comparisons were made concerning TVOC, NVOC, and composition ratios of NVOC. It was revealed that TVOC emission rates of midium density fiber (MDF) were the highest. Besides, it was found that emissions of NVOC from wood-based panels were much higher than those of anthropogenic AVOC except for plywood of Oceania timber. It was also observed that the composition ratio of NVOC emitted from plywood of Pinus radiata was the highest as 65% of TVOC. Major NVOC components were monoterpene compounds such as $\alpha$-pinene, $\beta$-pinene, d-limonene, camphene and $\alpha$-terpinene. It was concluded that the composition rates of VOCs emitted from building materials were clearly different according to the raw materials and manufacturing methods.

An Analysis of Changes in Air Pollutant Emissions Due to the Introduction of the Special Act on the Improvement of Air Quality in Port Areas -Focusing on Incheon Port (항만지역등 대기질 개선에 관한 특별법 도입에 따른 대기오염물질 배출량 변화 분석 -인천항을 중심으로 )

  • Lee, Min-Woo;Lee, Hyang-Sook;Lee, Jung-Wook
    • Journal of Korea Port Economic Association
    • /
    • v.39 no.3
    • /
    • pp.107-122
    • /
    • 2023
  • This study aims to analyze the effect of reducing air pollutant emissions of the ship fuel oil sulfur content regulation policy, which has been gradually introduced for three years. In addition, the emission reduction effect of VSR and AMP was also analyzed. The analysis was conducted on NOx, CO, VOC, SOx, TSP, PM10, and PM2.5, which are provided by EEA, and the spatial scope of the analysis was conducted on Incheon Port, which is located in the metropolitan area of Korea and has a large ripple effect on air pollution. Three scenarios were constructed for analysis. Scenario 1: If there is no policy, Scenario 2: If only fuel oil sulfur content regulation was implemented, Scenario 3: The analysis was conducted by reflecting fuel oil sulfur content regulation, VSR, and AMP. As a result of the analysis, in the case of scenario 1, 4,801 tons, 4,932 tons, and 5,144 tons of air pollutants were emitted during the three-year period. In Scenario 2, 4,219 tons, 4,152 tons, and 3,989 tons were discharged, and in Scenario 3, 4,198 tons, 4,138 tons, and 3,973 tons were discharged. The findings of this study are anticipated to be applied as fundamental research in port air environment management and Incheon Metropolitan City air management.

A Study on Estimation of Air Pollutants Emission from Traditional Fireplace in Korea (아궁이 사용에 의한 대기오염물질 배출량 산정에 관한 연구)

  • Kim, Dong Young;Choi, Min-Ae;Han, Yong-Hee;Park, Sung-Kyu
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.6
    • /
    • pp.538-544
    • /
    • 2014
  • A traditional fireplace has been used, but not much, for heating and cooking in rural area, Korea. Traditional fireplace as one type of biomass burnings is also emitting various air pollutants. Air pollutants emission from traditional fireplace was estimated in this study. There are two types of traditional fireplace, one for combined heating and cooking, the other one for cooking only. Types of fuels mostly used in traditional fireplace were wood, agricultural residue, solid waste. Activity levels such as fuel types, amount of fuel loading, and temporal variation were investigated by field survey over Korea. Estimated annual emissions from traditional fireplace were CO 6,335.0, NOx 555.0, SOx 9.6, VOC 1,771.7, TSP 181.4, $PM_{10}$ 119.9, $PM_{2.5}$ 96.2, $NH_3$ 1.4 ton/yr respectively. When emissions compared with the national emission inventory (CAPSS: Clean Air Policy Support System) of 2010 year, CO and $PM_{10}$ occupy 0.8% and 0.1% of total national emission, respectively.

A Study on the Characteristics of Monoterpene Emissions from Different Wood Species (건조목재의 모노테르펜 배출특성에 관한 연구)

  • Park Hyun Ju;Kim Jo Chun;Park Byung Dae;Park Kang Nam
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.1
    • /
    • pp.145-151
    • /
    • 2006
  • As the concerns about indoor air quality (IAQ) increase in recent years, lots of research works are under way to investigate the influence of volatile organic compounds (VOCs) emitted from building products on the IAQ. One of the regulations for the IAQ is the level of total VOCs (TVOCs) from building products, assuming that the TVOCs are suspected to cause many health problems such as skin irritation, asthma, and allergy. However, the presence of biogenic VOCs, or natural VOCs (NVOCs) is believed to be beneficial to human health. Therefore, this study attempted to investigate chemical species and the NVOCs compositions of solid lumbers from different wood species. It was found that major VOC components were monoterpenes such as $\alpha$-pinene, $\beta$-pinene, d-limonene, camphene, $\alpha$-terpinene, $\gamma$-terpinene etc.

Characteristics of Flue Gas Using Direct Combustion of VOC and Ammonia (휘발성 유기 화합물 및 암모니아 직접 연소를 통한 배기가스 특성)

  • Kim, JongSu;Choi, SeukCheun;Jeong, SooHwa;Mock, ChinSung;Kim, DooBoem
    • Clean Technology
    • /
    • v.28 no.2
    • /
    • pp.131-137
    • /
    • 2022
  • The semiconductor process currently emits various by-products and unused gases. Emissions containing pollutants are generally classified into categories such as organic, acid, alkali, thermal, and cabinet exhaust. They are discharged after treatment in an atmospheric prevention facility suitable for each exhaust type. The main components of organic exhaust are volatile organic compounds (VOC), which is a generic term for oxygen-containing hydrocarbons, sulfur-containing hydrocarbons, and volatile hydrocarbons, while the main components of alkali exhaust include ammonia and tetramethylammonium hydroxide. The purpose of this study was to determine the combustion characteristics and analyze the NOX reduction rate by maintaining a direct combustion and temperature to process organic and alkaline exhaust gases simultaneously. Acetone, isopropyl alcohol (IPA), and propylene glycol methyl ether acetate (PGMEA) were used as VOCs and ammonia was used as an alkali exhaust material. Independent and VOC-ammonia mixture combustion tests were conducted for each material. The combustion tests for the VOCs confirmed that complete combustion occurred at an equivalence ratio of 1.4. In the ammonia combustion test, the NOX concentration decreased at a lower equivalence ratio. In the co-combustion of VOC and ammonia, NO was dominant in the NOX emission while NO2 was detected at approximately 10 ppm. Overall, the concentration of nitrogen oxide decreased due to the activation of the oxidation reaction as the reaction temperature increased. On the other hand, the concentration of carbon dioxide increased. Flameless combustion with an electric heat source achieved successful combustion of VOC and ammonia. This technology is expected to have advantages in cost and compactness compared to existing organic and alkaline treatment systems applied separately.

A Pilot Study on Emissions of Air Pollutants Produced from Incineration of Some Municipal Solid Wastes

  • Kim, Haen-Gah;Lee, Byeong-Kyu;Cho, Jung-Bum
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.E2
    • /
    • pp.49-56
    • /
    • 2006
  • This pilot study focuses on emissions characterization of air pollutants produced from incineration of some municipal solid wastes (MSWs). The MSWs incinerated by an electric furnace maintained up to $600^{\circ}C$ included food, paper, and plastic wastes. The pollutants analyzed in this study included concentrations of volatile organic compounds (VOCs), bottom ash contents, and heavy metals extracted from the bottom ash of each waste. The VOCs identified were classified based on their chemical structure. The total emissions of VOCs produced from incineration of the papers were identified as the highest followed by those from the plastics and the food wastes. Aliphatic alkenes were major VOC compounds produced from incineration of plastic or food wastes, while furans were major VOCs produced from incineration of papers. The second major VOCs produced from incineration of food, plastics, and papers were aromatics. In particular, hazardous air pollutants such as benzene were produced with considerable amount of emission concentration. The bottom ash contents of papers were usually much higher than those of food or plastic wastes. The bottom ash contents produced from incineration of food and plastics were much lower than those of other MSWs. In analysis of heavy metals extracted by an ultrasonic method from the bottom ashes of the papers, high concentrations of heavy metals were identified from incineration of newspapers and box (cardboard). In addition, it was identified that the general public might be exposed to considerable amounts of lead concentrations during incineration processes and uses of paper cup and from ashes.

A Study on Estimation of Air Pollutants Emission from Wood Stove and Boiler, Wood-pellet Stove and Boiler (화목난로∙보일러와 펠릿난로∙보일러 사용에 의한 대기오염물질 배출량 산정에 관한 연구)

  • Kim, Dong-Young;Han, Yong-Hee;Choi, Min-Ae;Park, Sung-Kyu;Jang, Young-Kee
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.3
    • /
    • pp.251-260
    • /
    • 2014
  • Biomass burning is one of the significant emission source of PM and CO, but a few studies are reported in Korea. Air pollutants emission from biomass burning such as wood stove and boiler, and wood-pellet stove and boiler were estimated in this study. Activity levels related to biomass burning such as fuel types, amount of fuel loading, and location and temporal variation were investigated by field survey over Korea. Fuel loadings were 14.9 kg/day for wood stove, 31.3 kg/day for wood boiler, 12.8 kg/day for wood-pellet stove, 32.5 kg/day for wood-pellet boiler during the season of active use. These were mostly burned in winter season from october to april of next year. Estimated annual emissions from wood stove & boiler were CO 76,677, $NO_x$ 710, $SO_x$ 70, VOC 20,941, TSP 6,605, PM10 2,921, PM2.5 1,851, and NH3 7 ton/yr, respectively. Emissions from wood-pellet stove and boiler were CO 32,798, $NO_x$ 1,830, $SO_x$ 25, VOCs 5,673, TSP 629, PM10 457, PM2.5 344, and $NH_3$ 2 ton/yr, respectively. When the emission estimates are compared with total emissions of the national emission inventory (CAPSS: Clean Air Policy Support System), Those occupy 12.5%, 2.8% of total national emission for CO and PM10, respectively. These results show wood and wood-pellet burning appliances were one of the major source of air pollution in Korea. In future, these types of heaters need to be regulated to reduce air pollution, especially in suburb area.

PM2.5 Source Apportionment Analysis to Investigate Contributions of the Major Source Areas in the Southeastern Region of South Korea (동남지역 주요 배출지역의 PM2.5 기여도 분석)

  • Ju, Hyeji;Bae, Changhan;Kim, Byeong-Uk;Kim, Hyun Cheol;Yoo, Chul;Kim, Soontae
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.4
    • /
    • pp.517-533
    • /
    • 2018
  • We utilize the CAMx (Comprehensive Air Quality Model with eXtensions) system and the PSAT (Particulate Source Apportionment Technology) diagnostic tool to determine the $PM_{2.5}$ concentration and to perform its source apportionment in the southeastern region of South Korea. For a year-long simulation, eight local authorities in the region such as Pohang, Daegu, Gyeongju, Ulsan, Busan-Gimhae, Gosung-Changwon, Hadong, and all remaining areas in Gyeongsangnam-do, are selected as source areas based on the emission rates of $NO_x$, $SO_x$, VOC, and primary PM in CAPSS (Clean Air Policy Support System) 2013 emissions inventory. The CAMx-PSAT simulation shows that Pohang has the highest $PM_{2.5}$ self-contribution rate (25%), followed by Hadong (15%) and Busan-Gimhae (14%). With the exception of Pohang, which has intense fugitive dust emissions, other authorities are strongly affected by emissions from their neighboring areas. This may be measured as much as 1 to 2 times higher than that of the self-contribution rate. Based on these estimations, we conclude that the efficiency of emission reduction measures to mitigate $PM_{2.5}$ concentrations in the southeastern region of South Korea can be maximized when the efforts of local or regional emission controls are combined with those from neighboring regions. A comprehensive control policy planning based on the collaboration between neighboring jurisdictional boundaries is required.