• Title/Summary/Keyword: VO2

Search Result 906, Processing Time 0.025 seconds

Modeling and Investigation of Multilayer Piezoelectric Transformer with a Central Hole for Heat Dissipation

  • Thang, Vo Viet;Kim, In-Sung;Jeong, Soon-Jong;Kim, Min-Soo;Song, Jae-Sung
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.5
    • /
    • pp.671-676
    • /
    • 2011
  • A multilayer square-type piezoelectric transformer with a hole at the center was investigated in this paper. Temperature distribution at the center was improved by using this construction, therefore increasing input voltage and output power. This model was simulated and investigated successfully by applying a finite element method (FEM) in ATILA software. An optimized structure was then fabricated, examined, and compared to the simulation results. Electrical characteristics, including output voltage and output power, were measured at different load resistances. The temperature distribution was also monitored using an infrared camera. The piezoelectric transformer operated at first radial vibration mode and a frequency area of 70 kHz. The 16 W output power was achieved in a three-layer transformer with 96% efficiency and $20^{\circ}C$ temperature rise from room temperature under 115 V driving voltage, 100 ${\Omega}$ matching load, $28{\times}28{\times}1.8mm$ size, and 2 mm hole diameter. With these square-type multilayer piezoelectric transformers, the temperature was concentrated around the hole and lower than in piezoelectric transformers without a hole.

Effects of Vacuum Annealing on the Electrical Properties of Sputtered Vanadium Oxide Thin Films (스퍼터된 바나듐 산화막의 전기적 특성에 미치는 진공 어닐링의 효과)

  • Hwang, In-Soo;Lee, Seung-Chul;Choi, Bok-Gil;Choi, Chang-Kyu;Kim, Nam-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.435-438
    • /
    • 2003
  • The effects of oxygen partial pressure and vacuum annealing on the electrical properties of sputtered vanadium oxide($VO_x$) thin films were investigated. The thin films were prepared by r.f. magnetron sputtering from $V_2O_5$ target in a gas mixture of argon and oxygen. The oxygen/(oxygen+argon) partial pressure ratio of 0% and 8% is adopted. Electrical properties of films sputter-deposited under different oxygen gas pressures and in situ annealed in vacuum at $400^{\circ}C$ for 1h and 4h are characterized through electrical conductivity measurements. I-V characteristics were distinguished between linear and nonlinear region. In the low field region the conduction is due to Schottky emission, while at high fields it changes to Fowler-Nordheim tunneling type conduction. The conductivity measurements have shown an Arrhenius dependence of the conductivity on the temperature.

  • PDF

Analysis on the differences of mechanical efficiency from design characteristics of wheelchair (휠체어 디자인 특성에 따른 효율의 차이 규명)

  • Lim, Bee-Oh;Moon, Yeong-Jin;Eun, Seon-Deok
    • Korean Journal of Applied Biomechanics
    • /
    • v.13 no.1
    • /
    • pp.109-119
    • /
    • 2003
  • The purpose of this study was to investigate differences of the mechanical efficiency on the characteristics of the basketball wheelchairs(cambers & size of the handrims). Nine healthy and normal wheelchair basketball players who had no impairments to their upper extremities were volunteered to participate in this study. $VO_2$ was collected using automatic gas analyzer(vmax29). Gross efficiency, net efficiency and work efficiency were analyzed from the calculated external power output and energy expenditure. The results were followed. First, gross efficiency in the basketball wheelchairs was observed across the range from 4 to 10%. Gross efficiency in this study showed less values than that from the literature reviewed in the arm cranking(15%), racing wheelchair(above 30%), gait(27%) and cycling(18-23%). Second, the small size of handrim(61cm) at the 16 degrees of camber produced higher efficiency values than the large size of handrim(66cm) whereas the different sizes of handrim at the 20 degrees of camber did not show any pattern. Third, both faster speed($1.11^m/s{\rightarrow}1.39^m/s$) and increases in treadmill inclination produced increases in energy expenditure. The results of this study may provide not only better understanding of the mechanical efficiency with adequate camber degree and proper size of handrim but also fundamental information for manufacturing the wheelchair.

Evaluation of Drought Tolerance of Pleurospermum camtschaticum, Cirsium setidens and Parasenecio firmus Obtained from Pressure-Volume Curves (P-V 곡선을 통한 누룩치, 고려엉경퀴, 병풍쌈의 내건성 평가)

  • Lee, Kyeong-Cheol;Han, Sang-Sup
    • Korean Journal of Medicinal Crop Science
    • /
    • v.20 no.1
    • /
    • pp.36-41
    • /
    • 2012
  • This study was carried out to establish a proper cultivation site and diagnose the drought tolerance of Pleurospermum camtschaticum, Cirsium setidens and Parasenecio firmus leaves by using pressure-volume curves. The result of ${\Psi}_o^{sat}$ and ${\Psi}_o^{tlp}$ were lower in Pleurospermum camtschaticum leaves. On the other hand, it appeared that $E_{max}$ of Pleurospermum camtschaticum was approximately six times higher than that of Parasenecio firmus. The values of $RWC^{tlp}$ is all above 88% showing that the function of osmoregulation is somewhat better, and Vo/DW, Vt/DW, Ns/DW of Pleurospermum camtschaticum leaves were approximately 2~4 times Lower than other ones. Thus, responses to water relations of Pleurospermum camtschaticum, Cirsium setidens and Parasenecio firmus such as ${\Psi}_o^{sat}$, ${\Psi}_o^{tlp}$, $E_{max}$, ${\Psi}_{P,max}$, $RWC^{tlp}$ were shown that the Pleurospermum camtschaticum leave was higher drought tolerance than Cirsium setidens and Parasenecio firmus leaves.

Effect of Weight of Fire-protective Equipment for Physical Activity Ability (소방용 보호장구의 무게가 신체활동능력에 미치는 영향)

  • Huh, Man-Dong;Bang, Chang-Hoon
    • Fire Science and Engineering
    • /
    • v.24 no.1
    • /
    • pp.128-133
    • /
    • 2010
  • The aim of study intends to investigate effect of weight of fire fighting protective equipment for physical activity ability and to provide the base data for the safety of firefighter. The results of the study are as follows. The maximum all-out time is short about 18.8% in weight-jacket case which weight is same with fire-protective equipment than case of gym suit. The maximum oxygen consumption increased 17.6% in gym suit case than case of weight-jacket. The maximum heart rate is high 5.4% in gym suit case than case of weight-jacket.

A Case Study of Paraffin Double-walled Microencapsulation Preparation Using Acrylic Polymer and Melamine Polymer for Thermal Energy Storage

  • Nguyen, Hang Vo-Minh;Kim, Chae-Hyun;Kim, Jong-Kuk
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.5
    • /
    • pp.65-78
    • /
    • 2019
  • In this study, we investigated the paraffin encapsulation using double-walled encapsulation technique. The first encapsulation used methyl methacrylic acid as the main component in acrylic polymer and the second encapsulation used melamine polymer. Particles size and distribution of the capsules were analyzed using scanning electron microscopy. In the first encapsulation, the stable capsules were obtained at 67% of phase change material ratio to methyl methacrylic acid monomer and the size of the capsule was from 0.2 to $0.3{\mu}m$. In the second encapsulation, the size of the capsules was almost the same with those capsules prepared in the first encapsulation. The particle size of single wall and double wall was about $0.3{\mu}m$. As a result of the encapsulation of paraffin using double-walled encapsulation technique, it was confirmed that the particle size was determined in the process of encapsulating using the acrylic polymer at the first wall material, and the physical and thermal stability of the capsules were imparted using melamine at the secondary wall material.

Examination of the characteristics of the field test to evaluate the cardiovascular endurance of soccer players (축구선수의 현장 심폐지구력 테스트로서의 Shuttle run과 Yo-Yo intermittent recovery test의 특성 비교)

  • Shin, Sohee
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.4
    • /
    • pp.195-201
    • /
    • 2019
  • The purpose of this study was to propose an effective field test for assessing the cardiovascular endurance of soccer players by comparing the shuttle run test and the Yo-Yo intermittent recovery test (Yo-Yo test), which are representative of the aerobic exercise performance test, with the VO2max and other sprint tests. The shuttle run test requires the subject to run continuously without a break interval, while the Yo-Yo test has a break interval, so that they run with the recovery period. Therefore, the Yo-Yo test can be used as an effective field test for evaluating the cardiopulmonary function considering the characteristics of the soccer players of intermittent training.

The Effect of Dynamic Neuromuscular Stabilization (DNS) on the Respiratory Function of Subjects with Forward Head Posture (FHP)

  • Bae, Won-Sik
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.16 no.3
    • /
    • pp.55-64
    • /
    • 2021
  • PURPOSE: The purpose of this study was to apply dynamic neuromuscular stabilization (DNS) to subjects with forward head posture (FHP) and to compare its effects on respiratory function as against the conventional neck stabilization exercise and neck stretching and extensor strengthening exercises. METHODS: The whole-body posture measurement system was used to measure the degree of FHP, and a spirometer and a respiratory gas analyzer were used to measure the respiratory function. After the intervention was completed, the changes over time were analyzed in the DNS group, the neck stabilization exercise group, and the neck stretching and extensor strengthening exercise group. The inter-group difference in the changes was also analyzed. A repeated ANOVA was performed to compare the respiratory function according to the period between the three groups, and the least significant difference (LSD) method was used for the post hoc test. RESULTS: After the 6-week exercise period, respiratory functions, such as forced vital capacity (FVC), forced expiratory volume for 1 second (FEV1), forced expiratory volume for 1 sec/forced vital capacity (FEV1/FVC), maximum oxygen intake (VO2max), and the volume of expired gas (VE), significantly improved according to the period (p < .05), but no inter-group differences were found. CONCLUSION: DNS is an effective training method, and can be applied along with neck stabilization exercise and neck stretching and extensor strengthening exercises, which are widely used in clinical practice, to people with FHP who cannot directly perform neck exercises to improve their respiratory function.

Synthetic Homoisoflavane Derivatives of Cremastranone Suppress Growth of Colorectal Cancer Cells through Cell Cycle Arrest and Induction of Apoptosis

  • Shin, Ha-Eun;Lee, Seul;Choi, Yeram;Park, Sangkyu;Kwon, Sangil;Choi, Jun-Kyu;Seo, Seung-Yong;Lee, Younghee
    • Biomolecules & Therapeutics
    • /
    • v.30 no.6
    • /
    • pp.576-584
    • /
    • 2022
  • Colorectal cancer is diagnosed as the third most prevalent cancer; thus, effective therapeutic agents are urgently required. In this study, we synthesized six homoisoflavane derivatives of cremastranone and investigated their cytotoxic effects on the human colorectal cancer cell lines HCT116 and LoVo. We further examined the related mechanisms of action using two of the potent compounds, SH-19027 and SHA-035. They substantially reduced the cell viability and proliferation in a dose-dependent manner. Treatment with SH-19027 and SHA-035 induced cell cycle arrest at the G2/M phase and increased expression of p21 both of which are implicated in cell cycle control. In addition, the apoptotic cell population and apoptosis-associated marker expression were accordingly increased. These results suggest that the synthesized cremastranone derivatives have anticancer effects through the suppression of cell proliferation and induction of apoptosis. Therefore, the synthesized cremastranone derivatives could be applied as novel therapeutic agents against colorectal cancer.

Experimental behaviour of circular concrete filled steel tube columns under lateral cyclic loading

  • Cao, Vui Van;Vo, Cuong Trung;Nguyen, Phuoc Trong;Ashraf, Mahmud
    • Earthquakes and Structures
    • /
    • v.21 no.5
    • /
    • pp.445-460
    • /
    • 2021
  • This study experimentally explored the behaviour of 12 concrete filled steel tube (CFST) and steel tube columns subjected to lateral cyclic loading. The L/D ratio was 12.3 while D/t ratios were 45.4, 37.8 and 32.4, classifying these 12 specimens into 3 groups. Each group included 3 CFST and 1 steel tube columns and were tested to failure. The experimental results indicated that CFST specimens reached the state of 'collapse prevention' (drift 4%) prior to the occurrence of local buckling. Strength degradation of CFST specimens did not occur up to the failure by buckling. This showed the favourable characteristic of CFST columns in preventing collapse of structures subjected to earthquakes. The high energy absorption capability in the post collapse limit state was appropriate for dissipating energy in structures. Compared to steel tube columns, CFST columns delayed local buckling and prevented inward buckling. Consequently, CFST columns exhibited their outstanding seismic performance in terms of the increased ultimate resistance, capacity to sustain 2-3 additional load cycles and significantly higher drift. A simple and reasonably accurate model was proposed to predict the ultimate strength of CFST columns under lateral cyclic loading.